SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Similar documents
Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Installation Instructions

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Installation Instructions

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Installation Instructions

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

User s Information and Installation Instructions

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

The Saturation process

Installation Instructions

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

Refrigeration/Troubleshooting Manual

How to Diagnose a TXV Failurek

Warm Case Troubleshooting Guide 9/18/2014

Superheat charging curves for technicians

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

INSTALLATION INSTRUCTIONS

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

REFRIGERANT RECOVERY Log Book

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

Checking the Charge on a Heat Pump in the Winter

REFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE

Condensing Unit Installation and Operating Instructions

Air Conditioning Operation and Troubleshooting Matt Dunham

Otherwise, you can continue reading the file on the following pages.

MODEL URS-1: FACTORY RETROFIT PROGRAM

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

A/C-HEATER SYSTEM - MANUAL

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Pressure Enthalpy Charts

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KML F SERIES KML H SERIES

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

User s Information and Installation Instructions

Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM-500MRH SERVICE MANUAL

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Refrigeration System with a Capillary Tube and a Thermostat

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

SERVICE ASSISTANT OVERVIEW FDSI Online Training

KM-61BAH KM-101BAH KM-151BAH

Everything You. NEED to KNOW. TXV does this by keeping the coil supplied

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL

INSTALLATION INSTRUCTIONS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

The Essentials Of Working With R-410A

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Split Floor-Mounted Cooling System Operation Care Installation Manual

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

R100 Oil-Less Refrigerant Recovery Unit

SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI 89/336 73/23 SELF-CONTAINED CRESCENT CUBER KM-150BAF-E KM-150BWF-E

347002K/177002K/34900

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

T-Series Air Conditioner T15 Model

Hoshizaki America, Inc.

Service Step by Step Trouble-Shooting Check-List

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

HVAC Service Technicians Training Center

T-Series Air Conditioner T20 Model

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

R.A.S.E.R.S System. Installation Guide

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

KM-630MAH KM-630MWH KM-630MRH

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

Transcription:

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

UNIT OBJECTIVES After studying this unit, the reader should be able to Select the correct instruments for checking an air conditioning unit with a mechanical problem. Calculate the correct operating suction pressures for both standard- and high-efficiency airconditioning equipment under various conditions. Calculate the standard operating discharge pressures at various ambient conditions. Select the correct instruments to troubleshoot electrical problems in an air-conditioning system. Check the line- and low-voltage power supplies. Troubleshoot basic electrical problems in an air conditioning system. Use an ohmmeter to check the various components of the electrical system.

INTRODUCTION Troubleshooting air-conditioning equipment involves both the mechanical and electrical systems Symptoms may overlap Mechanical problems may appear to be electrical and vice versa Technicians must diagnose problems correctly

MECHANICAL TROUBLESHOOTING Gages and temperature-testing equipment are used when performing mechanical troubleshooting Always be aware of the system refrigerant R-410a pressures are much higher than R-22 R-22 gages on R-410a systems will be over pressurized and can become damaged Not all refrigerant oils are compatible, so gages should be used on only one type of refrigerant

LOW PRESSURE GAGE Pressure scale Gage needle Temperature scales for various refrigerants Vacuum range Gages provide temperatures and pressures for saturated refrigerants

GAGE MANIFOLD USAGE Displays the low- and high-side pressures while the unit is operating These pressures can be converted to the saturation temperatures Gage manifolds are used whenever the pressures need to be known for the system Gages are connected to service ports Used to calculate superheat and subcooling

LOW PRESSURE GAGE 68.5 psig 40 F This low side gage indicates a suction pressure of 68.5 psig, which means that the refrigerant is boiling at 40 F in the evaporator

Schrader valves to access refrigeration circuit When pin in the valve is pushed in, the valve is open and the refrigerant circuit can be accessed When pressure on the pin is removed, the valve seals itself closed and the refrigerant circuit is once again sealed closed

SERVICE VALVES Line port Service port Valve stem Device port Packing gland

SERVICE VALVES Backseated Position Service port is sealed, line port is open to the device port Normal operating position

SERVICE VALVES Cracked off the Backseat Position Service port is open to the line port and device port Position used for taking system pressure readings Position used for adding or removing system refrigerant

SERVICE VALVES Midseated Position Service port is open to the line port and device port Position used for system evacuation and leak checking

SERVICE VALVES Frontseated Position Service port is open to the device port Line port is sealed off Position used for pumping the system down

WHEN TO CONNECT THE GAGES Gage manifolds should not be connected every time a system is serviced Small amounts of refrigerant escape each time the gages are connected and removed from a sealed system Short gage hoses will limit the amount of refrigerant lost Low-loss fittings should be used

LOW-SIDE GAGE READINGS Used to compare the actual evaporating pressure to the normal evaporating pressure Standard-efficiency systems usually have a refrigerant boiling temperature of about 35 F cooler than the entering air temperature Under increased loads, the evaporator is absorbing extra sensible and latent heat from the air Gage readings when the system is operating in or close to design range will verify system s true performance

HIGH-SIDE GAGE READINGS Used to check the relationship of the condensing refrigerant to the ambient air temperature Standard efficiency air-cooled condensers condense the refrigerant at no more than 30 F higher than the ambient temperature High-efficiency condensers normally condense the refrigerant at a temperature as low as 20 F higher than the ambient temperature

TEMPERATURE READINGS For determination of the system s superheat and subcooling temperatures Common temperatures used for evaluation are: Indoor air wet-bulb and dry-bulb temperatures Outdoor air dry-bulb temperature Suction-line temperature Condenser outlet temperature Compressor discharge line temperature

CHARGING SYSTEMS IN THE FIELD When the system is operating correctly under design conditions, there should be a prescribed amount of refrigerant in the condenser, the evaporator, and the liquid line The amount of refrigerant in the evaporator can be measured by superheat The amount of refrigerant in the condenser can be measured by subcooling

FIELD CHARGING THE TXV SYSTEM Reduce the airflow across the condenser to simulate a 95 F outside air temperature The superheat check will not work for the TXV because it is designed to maintain a constant superheat of 8 to 12 under any load condition A subcooling check of the condenser can be used to check the system charge Typical subcooling circuit will subcool the liquid refrigerant from 10 to 20 cooler than the condensing temperature Excessive subcooling indicates an overcharge

ELECTRICAL TROUBLESHOOTING You need to know what the readings should be to know whether the actual readings are correct or not Begin any electrical troubleshooting by verifying that the power supply is energized and that the voltage is correct If the power supply voltage is correct, move on to the various components

L1 L2 RELAY OR CONTACTOR CONTROL CIRCUIT MOTOR RUN START START RELAY

L1 L2 Fuses Contactor contacts Contactor coil 3A 25A

L1 L2 Contactor coil CC1 Disconnect CC2 CC 24V from inside house S R C Compressor Low pressure control Condenser fan motor Wiring diagram of basic components in a control and compressor circuit

COMPRESSOR ELECTRICAL CHECKUP Technicians need to be careful when condemning a compressor Many condemned compressors are not bad Unnecessary labor and material costs Compressor problems can be mechanical or electrical

ELECTRICALLY CHECK A SINGLE-PHASE COMPRESSOR Make certain wires are disconnected from the compressor Make certain all compressor terminals are clean Check resistance from windings to ground (ohmmeter or megohmmeter) Check resistance of the start and run windings

ELECTRICALLY CHECK A SINGLE- PHASE COMPRESSOR (cont d.) Check continuity between run and start terminals Check voltage between common and run terminals and between common and start terminals Voltage readings should be within 10% of the rated voltage

ELECTRICALLY CHECK A THREE-PHASE COMPRESSOR Check resistance from windings to ground Make certain wires are disconnected from the compressor Make certain all compressor terminals are clean Check each winding from terminal to terminal The resistance readings should be the same in all windings

MECHANICALLY CHECKING A COMPRESSOR If the supply voltage is correct, the compressor should start If the compressor does not start, the compressor may be stuck Reversing the direction of the motor may free the motor

COMPRESSOR CAPACITY One or more cylinders may not be functioning properly Simulate design conditions as closely as possible If voltage is correct and amperage is very low, the compressor is not pumping to capacity Indicated by a high suction pressure and a low head pressure

TROUBLESHOOTING THE CIRCUIT ELECTRICAL PROTECTORS FUSES AND BREAKERS Open circuit breakers or blown fuses should be treated with caution Do not reset or replace a tripped breaker or fuse without trying to determine what caused the fuse to blow or the breaker to trip

SUMMARY - 1 Troubleshooting air-conditioning equipment involves both the mechanical and electrical systems Mechanical problems may appear to be electrical and vice versa Gages and temperature-testing equipment are used when performing mechanical troubleshooting Gage manifolds are used whenever the pressures need to be known for the system Gages are used to calculate superheat and subcooling

SUMMARY - 2 Gage manifolds should not be connected every time a system is serviced Short gage hoses will limit refrigerant loss Standard-efficiency systems usually have a refrigerant boiling temperature of about 35 F cooler than the entering air temperature Standard efficiency air-cooled condensers condense the refrigerant at no more than 30 F higher than the ambient temperature

SUMMARY - 3 Temperature readings are needed to calculate evaporator superheat and condenser subcooling The amount of refrigerant in the evaporator can be measured by superheat The amount of refrigerant in the condenser can be measured by subcooling Typical subcooling circuit will subcool the liquid refrigerant from 10 to 20 cooler than the condensing temperature

SUMMARY - 4 Begin any electrical troubleshooting by verifying that the power supply is energized and that the voltage is correct Use an ohmmeter to check compressor windings for grounds, shorts and open circuits Compressor voltage readings should be within 10% of the rated voltage If the supply voltage to the compressor is correct, the compressor should start