O-PEP Hygiene-Beileger

Similar documents
Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

I.F.U Re/Processing Reusable Medical Devices

Processing Instructions. Cleaning so easy.

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Cleaning and Sterilization for Instruments & Posts

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

Cleaning and Sterilisation for Burs, accessories and filling material

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

Fujinon Medical Hygiene. Reprocessing of flexible endoscopes and endoscopic accessories.

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Classification of Instruments -

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

Cleaning/Disinfection/Sterilisation

ENDOILLUMINATION. in accordance with EN ISO 17664

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Wet Loads presentation Tim Galekop Abstract 2006

Innova new M2 and M3 series

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

Your Health, our Technology AWD655. Instrument Washer Disinfector

Reusable Laryngoscope Blades and Handles


STERIDENT, STERIMAT, STERIMAT PLUS

X99 Series. Dental Handpiece. Instruction For Use

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Data of 57 hospitals** Estimated for England and Wales

The Hydrim M2 washer disinfector. Perfectly prepares large volumes of instruments for sterilisation.

Instructions for use Vacuum regulation valve with water trap

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Processing instructions for the Ligamys suture forceps

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Setting The Standards For A Safer Future

Washer-disinfector G 7831

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

For the ultimate in flexibility and cleanliness. Container and trolley washers for hospitals and CSSD units

For the sterilization of pharmaceutical products using the hot water cascade system.

LipoCollector II Operating Instructions

BS En 285:2006+a2:2009 Description: Sterilization.

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

Care instructions. Primus 1058 Life

Glassware Washers: Cleaning Glassware and Implements Used in Compounding, Part 2. Abstract. Kate James, RPh Deborah Ruriani

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

Care instructions ESTETICA E80. Always be on the safe side.

Your Health, our Technology AWD655. Instruments Washer Disinfector

CLEANING STARTS WITH

Developed by. Cleaning and Sanitation

ENDOSCOPE DECONTAMINATION : Where are we now!

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Guidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor

Instructions for use. Always be on the safe side.

Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

H5i disinfection guide

Operating instructions Washer-disinfector PG 8562

Aesculap Implant Systems

STERITITE INSTRUCTIONS FOR USE

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

RAP-hip Hip stem extraction set

The Do's and Don ts in the Instrument Sterilisation Process

Instructions for Use (GA16)

Operating / User Manual

Cleaning & Sterilization

Qualification of Washer/Disinfectors. Dr. Winfried Michels

Veterinary Autoclave

TETHYS H10 PLUS. As a result of constant technological updating, the technical data may be subject to change without prior notice.

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

eware Handling & Cleaning Procedures

Aesculap Implant Systems

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

SteelcoSure Independent performance verification of your equipment and processes

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Quick Start Guide. for dishwashers. en-au, NZ

Powerful and efficient trolley cleaning and sanitizing. WS 125 trolley washer. Group

Woven Crypton Selections

An evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments

G 7823 PG Washer-disinfectors for hospitals and central sterilisation departments

DEKO 190. Washer-disinfector for human waste containers

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Reprocessing of surgical instruments

Instructions for Use. Air Power Line II. Power tools for endoprosthetics and traumatology.

Laboratory Glassware Washer-Disinfectors

Quality makes the Difference. AquaTREND uni. User s Manual Humidifi er for Therapeutic Air Flow

Packing. Euronda Spa t (+39) m euronda.com

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Transcription:

O-PEP Hygiene-Beileger 2013 PARI GmbH Spezialisten für effektive Inhalation, 018D5002-A 02/13

Hygienic re-use in the professional setting - 13 - en Information as of: 2013-02. We reserve the right to make technical changes. General... 14 Material information... 16 Processing limits... 21 Preparation... 22 Cleaning and disinfection... 17 Mechanical cleaning and disinfection... 17 Manual cleaning... 18 Manual disinfection... 19 Sterilisation... 20 Visual inspection... 21 Storage... 28 Contact... 29

1 General - 14 - In a professional setting, do not use the support strap or the storage pouch, because neither of these items can be disinfected or sterilised. Ensure that the system is processed... NOTICE Ensure that the system is processed for re-use only with the application of adequately validated device- and product-specific procedures, and that the validated parameters are maintained during each cycle. The equipment used must be maintained regularly. Follow the schedule defined below for hygienic re-use: Single patient use: Clean the PARI O-PEP after every application. Disinfect it at least once a month. Multiple patient use: Clean, disinfect and sterilise the PARI O-PEP before every change in patient. The PARI O-PEP must be processed for re-use with the application of suitable, validated methods in such manner that the success of these methods can be monitored reliably and the safety and health of patients is not threatened. Ensure that the components are allowed... CAUTION Ensure that the components are allowed to dry sufficiently after each processing step. Condensation or residual wetness can present an increased risk through the growth of bacteria.

- 15 - en The following text describes the methods validated by PARI, with which plastic PARI parts can be processed effectively. Ensure that the desired results are achieved... Ensure that the desired results are achieved consistently by the processing methods employed by your staff with the equipment and chemicals used. Take particular care to ensure that the processing procedure you select is effective if it must differ from our validated procedures (e.g., because the equipment and chemicals described are not available). When selecting the chemicals for use, make sure that they are suitable for cleaning or disinfecting medical products made from the materials indicated. Bear in mind the manufacturer's dosing information and instructions for safe handling of chemicals.

- 16-2 Material information POM (polyoxymethylene) Polyester Stainless steel Lower part with mouthpiece, funnel, upper part Pouch, support strap Ball 3 Processing limits The PARI O-PEP can be sterilised up to 300 times and used for up to one year. Do not expose the PARI O-PEP to temperatures above 137 C. The support strap and storage pouch cannot be hygienically treated. 4 Preparation Dismantle the PARI O-PEP into its individual parts: Unscrew the upper part from the lower part. Take the ball out of the funnel. Place it carefully on one side so that it cannot roll away. Take the funnel out of the lower part.

5 Cleaning and disinfection - 17 - en Clean and disinfect immediately after use. Ideally, a mechanical procedure (instrument dishwasher) is to be used. When selecting the cleaning agent... NOTICE When selecting the cleaning agent and/or disinfectant, ensure that it is compatible with the materials used, otherwise damage to the product components cannot be ruled out. 5.1 Mechanical cleaning and disinfection EQUIPMENT Cleaning and disinfection device in conformance with DIN EN ISO 15883 Cleaning agent Neutralising agent if necessary PROCEDURE Arrange the components so that they can be cleaned most effectively. Select a suitable cleaning programme and agent. VALIDATION The method has been validated using: G7836 CD cleaner-disinfector produced by Miele, programme Vario TD. Standard baskets manufactured by Miele Neodisher Mediclean forte 0.5% and Neodisher Z for neutralisation (from Dr. Weigert)

DRYING 5.2 Manual cleaning - 18 - Even if the cleaner-disinfector is equipped with a drying function, make sure that no residual moisture is left in the components. If necessary, remove any residual moisture by shaking the parts and allow them to dry completely. As an alternative to mechanical cleaning and disinfection, the following manual method can be used: EQUIPMENT Cleaning agent Brush Warm water PROCEDURE Place all the parts in the cleaning solution. Clean the parts thoroughly with a brush. Thoroughly rinse the parts under hygienically tested water and leave them to dry completely on a clean, dry and absorbent surface. VALIDATION The method has been validated using: Bodedex forte 0.5% (Block) Approx. 50 C warm water Duration of cleaning procedure: approx. 5 minutes

5.3 Manual disinfection - 19 - en For manual disinfection, select a suitable instrument disinfectant that has been proven to be effective and compatible with the cleaning agent used. EQUIPMENT Disinfectant Water PARI product components are not... CAUTION PARI product components are not suitable for treatment with instrument disinfectants based on quaternary ammonium compounds. Quaternary ammonium compounds tend to become concentrated in plastic materials, which can cause incompatibility reactions in patients. PROCEDURE Place all the parts in the disinfection solution. Allow the solution to take effect as indicated in the instructions for use of the disinfectant. Thoroughly rinse the parts under hygienically tested water and leave them to dry completely on a clean, dry and absorbent surface. VALIDATION The method has been validated using: Korsolex Basic 4% (Bode) Treatment time: 15 minutes

- 20-6 Sterilisation A validated sterilisation process... NOTICE A validated sterilisation process can only be carried out on products that have been cleaned and disinfected. Sterilisation EQUIPMENT Steam steriliser preferably with fractionated pre-vacuum in accordance with DIN EN 285 or DIN EN 13060 (type B) PROCEDURE Pack all of the disassembled parts in a sterile barrier system in accordance with DIN EN 11607 (e.g., foil-paper packaging). Maximum sterilisation temperature and holding time: 121 C, at least 20 min. or 132 ºC / 134 ºC, at least 3 min. VALIDATION The method has been validated according to DIN EN ISO 17665-1 using: Euro-Selectomat 666 from MMM (fractionated pre-vacuum method) Varioklav 400 E from H+P Labortechnik (gravitation method)

7 Visual inspection - 21 - en Inspect all product components after each cleaning, disinfection and sterilisation. If any components have been damaged, the whole product must be replaced. 8 Storage Store the PARI O-PEP in a dry, dust-free place away from sources of contamination. 9 Contact For all product information and in the event of defects or ques- all product information... tions about usage, please contact our Service Center: Tel.: +49 (0)8151-279 279 (German-speaking) +49 (0)8151-279 220 (international)