Processing Instructions. Cleaning so easy.

Similar documents
Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

I.F.U Re/Processing Reusable Medical Devices

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

O-PEP Hygiene-Beileger

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Cleaning and Sterilization for Instruments & Posts

Cleaning and Sterilisation for Burs, accessories and filling material

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

CLEANING INSTRUCTIONS

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

RECOMMENDATIONS FOR CLEANING DEVICES

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Instructions for Cleaning, Sterilization, Inspection and Maintenance. of Trauma & Extremities Medical Devices

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Aesculap Implant Systems

Aesculap Implant Systems

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Recommendations for cleaning, decontamination and sterilisation. devices

RAP-hip Hip stem extraction set

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

Instructions for Use Spinal Punches IFU

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

SteelcoSure Independent performance verification of your equipment and processes

Cleaning & Sterilization

Classification of Instruments -

For the ultimate in flexibility and cleanliness. Container and trolley washers for hospitals and CSSD units

Operating instructions MACH M3

ENDOILLUMINATION. in accordance with EN ISO 17664

Reusable Laryngoscope Blades and Handles

Operating / User Manual

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care

When you sterilize an instrument set, you know what the standards are.

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

STERITITE INSTRUCTIONS FOR USE

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Processing instructions for the Ligamys suture forceps

X99 Series. Dental Handpiece. Instruction For Use

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

Instructions for Use (GA16)

FLASH PAK STERILIZATION CONTAINER SYSTEM

Your Health, our Technology AWD655. Instrument Washer Disinfector

THE BASICS OF DECONTAMINATION

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Reprocessing Instructions for Reusable Surgical Instruments English

Ultrasonic From delicate microsurgery instruments to heavy duty sets

PERFORM Operating Document

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

Instruction of use. Flexible Naso-Pharyngo- Laryngofiberscope,

Disinfecting And Sanitizing Animal Facilities

Lower Your Costs. Expand Your Flexibility.

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Important information

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Lower Your Costs. Expand Your Flexibility.

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Directions for use MACH LED 300DF

LABOKLAV. Autoclaves Made in Germany

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

STERIS Instrument Cleaning Chemistries

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

ENDOSCOPE DECONTAMINATION : Where are we now!

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

36.0 Sterile Supply Unit (SSU)

Fiona Collins Liliana Donatelli Andrew Smith

Operating instructions Washer-disinfector G 7825/G 7826

STERIDENT, STERIMAT, STERIMAT PLUS

Flexible endoscope automated reprocessing system

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

ComPact Air Drive II USER S MANUAL

Transcription:

EN Processing Instructions. Cleaning so easy.

2

A good decision. Congratulations on your new tiologic easyclean Wash-Tray. Machine treatment of the entire instrument set is an essential component of quality assurance. For this reason, Dentaurum Implants has developed the tiologic easyclean Wash-Tray in collaboration with Miele Professional. This comprehensive system solution meets a new quality requirement in implantology: the automatic washing and disinfection of a completely packed surgical tray. In the tiologic easyclean, minimal contact surface, an innovative lattice structure and a fine mesh tray ensure the optimal washing of each component. This innovative cleaning concept considerably simplifies the daily workflow and helps increasing safety, not only during implantation but also during processing. In addition, tiologic easyclean significantly helps saving working time and ensures reproducible machinetreatment results. Another benefit of tiologic easyclean: during implantation, the instruments can be put back in the corresponding slots after use. Hence, each instrument is always located in the intended place. Mostly, there is no need for manual treatment of individual components, for the fully loaded tiologic easyclean is directly placed in the corresponding basket of the Dental Washer Disinfector. It is thus an optimal system solution for doctors surgeries and central treatment centres. p.p. Tobias Grosse Division Manager Dentaurum Implants 3

Content. tiologic easyclean Wash-Tray General instructions Cleaning so easy 6 Application Cleaning and desinfection Preconditioning Care, checking, maintenance Sterilization procedures Correct storage Material resistance 8 9 9 11 12 13 13 Reusability of surgical instruments Torque ratchet Insertion key 14 15 4

5

Cleaning so easy. tiologic easyclean the tray for machine processing. 1 Developed in collaboration with: The tested tiologic easyclean can be excellently cleaned without mechanical pre-cleaning. 1 1 Cleaning investigation tiologic easyclean, AFIP, 2012. 6

Innovative lattice structure. Stable fixation spring. Clear guidance system. Reproducible machine-treatment results. The tiologic easyclean is a Wash-Tray that contains all the rotary instruments and accessory components needed for implantation. They are arranged according to the operation sequence. For optimal orientation there is a colour-coded and laser-labelled plastic clip beside each instrument. The used instruments and accessory components are put back in the corresponding slots directly after each use. This increases safety during implantation as all instruments are always located in the intended place. After implantation, the completely packed tiologic easyclean is transferred to the machine treatment cycle. Small parts and accessory components to be disassembled are placed in the mesh tray. Advantages: Machine treatment of the completely packed surgical tray. Guaranteed by: optimal washing of the components minimal contact surface innovative lattice structure fine mesh tray Added value for the practice: no manual treatment necessary reproducible machine treatment results saves working time no sorting of components necessary Suitable for doctors surgeries and central treatment centres. 7

General instructions.! Special measures are required with certain instruments. Please refer to section Reusability of surgical instruments p. 14! Application. For reuse, all instruments should be cleaned, disinfected and sterilized before each use. This applies in particular to initial use, as all instruments are supplied non-sterile (clean and disinfect after removing the transport packaging). Thorough cleaning and disinfection is essential for effective sterilization. The operator is responsible for the sterility of the instruments and should always ensure that only properly validated procedures relating to the unit and the product are used for cleaning, disinfection and sterilization, that the units used (disinfector, sterilizer) are regularly serviced and checked and that the validated parameters are maintained during each cycle. tiologic easyclean instruments can be put back in the tray when they are dirty. Prior to cleaning in the Dental Washer Disinfector, all instruments to be dismantled (torque ratchet, placement aids, etc.) should be disassembled and put in the closable screen basket. After removing loose dirt, tiologic easyclean is placed in the upper basket of the Dental Washer Disinfector for cleaning and disinfecting. The fully loaded tray should then be sterilized in the Aesculap sterilisation container. The current legal regulations in the relevant country as well as the hygiene regulations of the dental practice or hospital should be adhered to. This applies in particular to the different instructions regarding effective inactivation of prions. 8

Cleaning and disinfection Basic instructions. For washing and disinfecting tiologic easyclean, a mechanical procedure should be used (Dental Washer Disinfector). For instruments and accessory components with hollow sections, special processing steps should be observed (see preconditioning). Preconditioning. Loose dirt should be removed from the instruments immediately after use (within maximum 2 hours). Loose dirt should be removed under running water or using a disinfectant solution; the disinfectant should not contain aldehyde (may cause fixation of blood debris) and should have certified efficacy (e.g. DGHM or FDA approved and CE marking); it should also be suitable for disinfection of the instruments and compatible with the instruments (p. 13 section Material resistance). Only a soft brush or a clean, soft cloth should be used for removing dirt manually; metal brushes or steel wool should never be used. If applicable: rinse all hollow sections of the instruments 5 times using a disposable syringe (minimum volume 5.0 ml). Note that the disinfectant used for preconditioning is only for personal protection and cannot be regarded as a substitute for subsequent disinfection after cleaning. Mechanical cleaning / disinfection (disinfector or cleaner / disinfector). When choosing a disinfector, ensure that the efficacy of the disinfector has been certified (e.g. DGHM or FDA approved and CE marking according to DIN EN ISO 15883), a certified programme for thermal disinfection (minimum 5 min. at 90 C / 194 F or an A0 > 3000) is used (with chemical disinfection there is the risk of disinfectant residue on the instruments), the programme used is suitable for the instruments and has an adequate number of rinse cycles, it uses only water that is sterile or has a low bacteria count (max. 10 bacteria / ml) and is low in endotoxins (max. 0.25 endotoxin units / ml) (e.g. purified water / highly purified water) for rinsing, the air used for drying is filtered, the disinfector is regularly serviced and checked. 9

General instructions.! Special measures are required with certain instruments. Please refer to section Reusability of surgical instruments p. 14! Cleaning supplies. When choosing a cleaning agent system, ensure that it is suitable for cleaning metal and plastic instruments, provided that thermal sterilization is not used an additional disinfectant with certified efficacy (e.g. DGHM or FDA approved and CE marking) is used and that it is compatible with the cleaning agent used, the chemicals used are compatible with the instruments (p. 13 section Material resistance), the concentrations given by the cleaning agent and disinfectant manufacturer must be strictly adhered to. Sequence Cleaning. 1. Removing loose dirt from instruments and tray. 2. Dismantling instruments (p. 14 Reusability of surgical instruments). 3. Placing the dismantled instruments in the basket and sealing it. 4. Inserting remaining instruments in the intended places. 6. Starting the cleaning programme of the Dental Washer Disinfector according to manufacturer s instructions. 7. Removing tiologic easyclean from the Dental Washer Disinfector at the end of the programme and, if necessary, additionally dry it in a clean place. 8. Controlling instruments (p. 11 Care, checking, maintenance). 9. Mounting dismantled instruments and reinserting them in the intended places of tiologic easyclean. 10. Inserting tiologic easyclean in the corresponding sterilization container and sterilizing it. Proof of basic suitability for effective automatic cleaning and disinfecting was provided by an independent, accredited test laboratory using a G 7836 GD disinfector (thermal disinfection, Miele & Cie. GmbH & Co., Gütersloh, Germany) and neodisher Medizym cleaning agent (Dr. Weigert GmbH & Co. KG, Hamburg, Germany). The procedure described above was taken into account during the tests. 5. Putting the equipped tiologic easyclean in the upper basket of the Dental Washer Disinfector. 10

Care, checking. Instruments should be checked after cleaning or cleaning / disinfection for corrosion, damaged surfaces, chipped edges and contamination. Damaged instruments should be discarded (p. 14 section Reusability of surgical instruments). Instruments that are still contaminated should be cleaned and disinfected again. Maintenance. Reassembly of instruments (p. 14 section Reusability of surgical instruments). If possible, instrument oils should not be used. If oil is to be used, ensure that only instrument oils (white oil) are used, which depending on the maximum sterilization temperature used are approved for steam sterilization and certified biocompatible. 11

General instructions.! Special measures are required with certain instruments. Please refer to section Reusability of surgical instruments p. 14! Sterilization procedures. Sterilization should only be completed using the sterilization procedures listed below; other sterilization procedures are not approved. Steam sterilization. steam sterilizer in accordance with DIN EN 13060 or DIN EN 285 validated in accordance with DIN EN ISO / ANSI AAMI ISO 17665 (formerly: DIN EN 554 / ANSI AAMI ISO 11134) (valid commissioning and product-specific performance evaluation) maximum sterilization temperature 134 C / 273 F; including tolerance in accordance with DIN EN ISO / ANSI AAMI ISO 17665 (formerly: DIN EN 554 / ANSI AAMI ISO 11134) sterilization time (exposure time at the sterilization temperature) minimum 5 min at 134 C / 273 F Proof of basic suitability for effective steam sterilization was provided by an independent, accredited test laboratory using a EuroSelectomat steam sterilizer (MMM Münchener Medizin Mechanik GmbH, Planegg, Germany) and the fractional vacuum process as well as a Systec V-150 steam sterilizer (Systec GmbH Labor- Systemtechnik, Wettenberg, Germany). The procedure described above was taken into account during the tests. Flash sterilization or gravitational method should never be used. Do not use hot-air sterilization, X-ray sterilization, formaldehyde or ethylene oxide sterilization or plasma sterilization. 12

Correct storage. After sterilization the tiologic easyclean has to be stored dry and dust free in the sterilization container. Material resistance. When choosing the cleaning agent and disinfectant, ensure that they do not contain the following components: organic, mineral or oxidizing acids (maximum permitted ph 9.5, a neutral / enzymatic cleaner is recommended) strong alkali organic solvents (e.g. alcohol, ether, ketones, benzene) oxidation agents (e.g. hydrogen peroxide) halogens (chlorine, iodine, bromine) aromatic/ halogenated hydrocarbons heavy metal salts Never clean instruments and sterilization trays with metal brushes or steel wool. 13

Reusability of surgical instruments. Rotary instruments can be reused up to 30 to 40 times with proper care and provided that they are not damaged or contaminated; the operator is deemed responsible for any further reuse or the use of damaged and/ or contaminated instruments. We do not accept any liability if these instructions are disregarded. Torque ratchet. Disassembly. Fully unscrew the adjusting screw from the torque ratchet handle and remove the springs. Leave the stopper on the spring. Loosen the screw on the ratchet head with the hex key in the adjusting screw using light pressure. Remove the cover from the ratchet head. Remove the two components, the ratchet core and ratchet wheel, from the ratchet head. The ratchet head and handle are in one piece; the screw is secured in the ratchet head and can be removed if required. Removing the adjusting screw. Opening the ratchet head. Cover removed. Ratchet wheel. Ratchet wheel and ratchet core. 14

Assembly. To ensure that the torque ratchet functions perfectly, adhere strictly to the following sequence when assembling the ratchet. First insert the ratchet wheel into the open ratchet head. This should fit flush in the round recess; turn it 180 if necessary. Then insert the ratchet core. This can also only be placed in a defined position so that the pawl sits between the teeth of the ratchet wheel. The contact zones between the teeth of the ratchet wheel and the ratchet core are easily lubricated. Always use the Instrument Lubricant (USDA H1 approved) supplied with the ratchet for lubrication. Remove any excess lubricant on the outer surface of the torque ratchet. After the components have been inserted, replace the cover on the ratchet head and hold it in position. Turn the torque ratchet over and tighten the screw with the hex key until the cover is securely retained. Insert the spring with the stopper towards the front into the ratchet handle and tighten the adjusting screw slightly. Check the function after assembly. Sterilization. The torque ratchet should be fully assembled for sterilization. If there are signs of corrosion, the components should be conditioned in a 0.1 % sodium nitrite solution prior to sterilization. Dry-heat sterilization (hot-air sterilizer) is not approved, as this can accelerate wear and tear on the spring, which affects the torque. Insertion key. Prior to cleaning, counter screws must be removed from the insertion keys and placed in the wire basket. 15

Dentaurum Group Germany I Benelux I España I France I Italia I Switzerland I Australia I Canada I USA and in more than 130 countries of the world. www.dentaurum.de For more information on our products and services, please visit www.dentaurum.de Date of information: 03/13 Subject to modifications 989-998-20 Printed by Dentaurum Germany 03/13 Turnstraße 31 I 75228 Ispringen I Germany I Phone + 49 72 31 / 803-0 I Fax + 49 72 31 / 803-295 www.dentaurum-implants.de I info@dentaurum-implants.de