FIFTH CLASS POWER ENGINEER S

Similar documents
CLASS POWER ENGINEER S CERTIFICATE

REFERENCE SYLLABUS. For FOURTH CLASS POWER ENGINEER S. CERTIFICATE of COMPETENCY EXAMINATION. AB-54 Edition 1, Revision 1,

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

4 th Class Power (Operating) Engineer Certification and Examination Guide

GENERAL INFORMATION. The candidate is allowed to bring the following items into the examination room:

Page 1 of Relevant Provincial Jurisdictional legislation.

2007 ASME Boiler & Pressure Vessel Code 2007 Edition July 1, 2007

RECOMMENDED READING GUIDE FOR REFRIGERATION PLANT EXAMINATION CANDIDATES

Miniature Hobby Boiler Inspection and Certification Requirements

Power Boiler Design, Inspection, and Repair

HVAC Workshop â Air Conditioning & Boilers

2009 IPC ,IMC Q &A ANDIFGC

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

CONTENTS. B. System Design and Performance Requirements

Government Gazette Staatskoerant

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

DIRECTIVE NO: D-B

TABLE OF CONTENTS. Part I Administrative

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

2009 IRC. and Fuel gas Provisions

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

SECTION PLUMBING EQUIPMENT

Development of Boiler Design

First Revision No. 20-NFPA [ Section No ]

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

User s Information Manual

UK Direction BS7671 BS 8492 BS /01/2018

CHAPTER 10 STEAM AND HOT WATER BOILERS

Boiler. Fire tube Boiler:

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.

Air Conditioning Technology

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

AFUE 95% Heating Input 50,000 to 200,000 Btuh

DIVISION FINNED WATER-TUBE WATER HEATERS

GASEOUS HYDROGEN SYSTEMS

TABLE OF CONTENTS. Part I Administrative... 1

CSD-1 COMMERCIAL BOILER CONTROLS

JEFFERSON COLLEGE COURSE SYLLABUS HRA290 NORTH AMERICAN TECHNICIAN EXCELLENCE CERTIFICATION. 1 Credit Hour. Prepared by William Kaune

Test Code: 8117 / Version 1

SAMPLE SPECIFICATIONS

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. SOET 348 Engineering Safety

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Special Boiler License Study Material

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Revitalize Building Mechanical Systems (4619)

Completed Projects / Projets terminés

Rental Boiler Specifications (Nebraska Boiler)

SECTION PLUMBING EQUIPMENT

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Historical Perspectives for Hydrogen Safety, Regulations, Codes and Standards (California and U.S.A.)

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Drum Level Instrumentation and. The ASME Boiler Code Requirements. Presented by: Jim Kolbus. Topics

West Norriton Township

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

COURSE OUTLINE Fire Protection Systems

Standards Update Notice (SUN) Issued: January 9, 2017

PACKAGED COMMERCIAL WATERTUBE BOILERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Steamfitter-Pipefitter A Guide to Course Content

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

Committee on NFPA 85

HVA 140 RESIDENTIAL HEATING

NFPA Fire Inspector I Study Guide

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

SAFETY CONTROL REQUIREMENTS FOR OVENS AND FURNACES

SUBSIDIARY LEGISLATION STEAM AND HOT WATER BOILERS REGULATIONS

SECTION HEATING BOILERS

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20

Boiler Basics. Design and operation

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

UNIFORM MECHANICAL CODE

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

PESIT-Bangalore South Campus

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

TABLE OF CONTENTS. Part I Administrative... 1

Analysis of Changes for the 6 th Edition (2017) Florida Codes

SYLLABUS. Departmental Syllabus. Fire Protection Equipment Alarm Systems. Departmental Syllabus. Departmental Syllabus. Departmental Syllabus

Explosion Protection Engineering Principles

Level I Chapter 1 Worksheet

ATPF-2130: OIL AND HYDRONICS

Gasfitter A Level 3 Rev. June 2011

Lassen Community College Course Outline

Transcription:

AB-55 Edition 1, Revision 1, 2017-09

GENERAL INFORMATION Introduction: The Standardization of Power Engineers Examination Committee (SOPEEC) has developed a Fifth Class Power Engineer s Syllabus (SOPEEC Syllabus) which has been approved by the Association of Chief Inspectors (ACI) to be used across Canada. As provided for under the Power Engineers Regulation, the Administrator in the pressure equipment discipline has established this Syllabus to identify the examination subjects for Fifth Class Power Engineer s Certificate of Competency examinations. The subjects described in this Syllabus are identical to the subjects in the SOPEEC Syllabus. This Syllabus is intended to assist candidates studying for the Fifth Class Power Engineer s Certificate of Competency Examination. The requirements to qualify for a Fifth Class Power Engineer s Certificate of Competency examination are outlined in the Power Engineers Regulation. Recommended Study Program: It is mandatory, that before undertaking a Fifth Class Engineer s examination, the candidate must complete a Fifth Class Power Engineering course offered through a technical institute. In addition to the foregoing course, it is recommended that the candidate becomes familiar with the publications listed in the Reference Material for Power Engineering Students and Examination Candidates which is obtainable from the various technical institutes or from the SOPEEC website. (www.sopeec.org) Application to Undertake Examination: A candidate must submit an application and the prescribed fee at least twenty-one (21) days before the date of examination. 2017-09 AB-55, Edition 1, Revision 1 Page 1 of 7

GENERAL INFORMATION Examination Instructions: The examination consists of one (1) examination paper with 150 multiple-choice questions, 3 ½ hours duration. To pass a 5 th Class Power Engineer s certificate of Competency examination, a candidate must obtain at least 65% of the total marks allotted. A candidate is allowed to use the following items in the examination room: The Safety Codes Act and Regulations under the Safety Codes Act; CSA B51, Boiler, Pressure Vessel and Pressure Piping Code; CSA B52, Mechanical Refrigeration Code; Extract for CSA B51 and CSA B52 Codes; ASME Boiler & Pressure Vessel Codes except for Sections VI and VII; The 2007 ASME Boiler & Pressure Vessel Code Academic Extract and Supplement produced by PanGlobal Training Systems; ASME/ANSI B31.1 Pressure Piping Code and B31.3 Process Piping Code; Handbook of mulae and Physical Constants, Steam Tables and Refrigeration Tables are normally provided; A non-technical English language dictionary; Pens and pencils; Non-programmable calculator and Drawing instruments and drawing templates. Note: The candidate must provide picture ID to the Examiner prior to the examination. No cell phone or any electronic communication devices are allowed to be brought into the examination room. The items referenced above must be shown to the Examiner for approval. No other reference material is allowed. The information in the 1983 Edition of the ASME Boiler and Pressure Vessel Code Academic Extract is outdated. Using this 1983 Edition of the ASME Extract for any power engineering examination is not recommended. Besides using the 2007 Edition of the ASME Academic Extract and Supplement, candidates may use the current edition of the ASME Code. 2017-09 AB-55, Edition 1, Revision 1 Page 2 of 7

A. Administration and Mechanical Drawing i. Log Books, technical communication and plant diagrams B. Act and Codes i. An understanding of the Safety Codes Act and applicable regulations Introduction to CSA and ASME Codes for Power and Heating Boilers C. Applied Science i. Areas and volumes of solids i Simple machines Introduction to mechanics Introduction to thermodynamics v. Thermodynamics and properties of steam Thermodynamics and properties of refrigeration D. Safety i. Fire safety: classes of fires, types and operation of extinguishers i Building and occupant safety Confined space entry Safe storage of flammables v. WHMIS classification of controlled products a. Labeling of Controlled Products b. Material Safety Data Sheets v vi ix. Personal safety equipment Occupational health and safety legislation Housekeeping Artificial respiration/acceptable methods; CPR; treatment for electric shock x. Safe work systems 2017-09 AB-55, Edition 1, Revision 1 Page 3 of 7

E. Welding and Plumbing i. Welding terms and inspection i Hot water heaters: operation and maintenance Building water supply systems: operation, maintenance, safety Sanitary drainage systems: repair, safety F. Pumps, Piping and Valves i. Types of Pumps i Pump components Pump operation and maintenance Piping materials and connections v. Piping: expansion, support, insulation and drains v Types and operation of steam traps Introduction to valves: types and applications G. Boiler Details i. Materials used in construction i Basic boiler terminology Watertube, tubular, firetube, cast-iron sectional and modular heating boilers Electric boilers v. High pressure boilers: components, operation, maintenance, repair, inspections, knowledge of power plant auxiliary equipment 2017-09 AB-55, Edition 1, Revision 1 Page 4 of 7

H. Boiler Fittings i. Basic fittings for steam heating boilers i Operation and testing of boiler safety valve, boiler gauge glass and water column Basic fittings for hot water boilers I. Fuels and Combustion i. Types of fuels, combustion principles, draft and flue gas analysis i Gas burners for boilers Oil burners for boilers Draft: natural, induced and forced v. Boiler and furnace explosions J. Boiler Controls i. Low water fuel cutoffs; operation and testing i Heating boiler feedwater controls Heating boiler operating controls Heating boiler combustion controls v. Boiler programmable controls and safety interlocks K. Boiler operation, maintenance and water treatment i. Hot water heating boilers: start-up, operation and shut-down i Steam heating and power boilers: start-up, operation, shut-down Testing safety devices Cause and prevention of boiler explosions v. Boiler maintenance and preparation for inspection Replacement of tubes and stays 2017-09 AB-55, Edition 1, Revision 1 Page 5 of 7

v vi ix. Boiler cleaning Boiler lay up Boiler water treatment basic chemistry, monitoring and testing x. Boiler hydrostatic testing and safety precautions L. Heating Systems and Human Comfort i. Heat gains and losses i Steam heating equipment Steam heating systems and operation Hot water heating systems equipment and operation v. Steam to hot water convertor v vi ix. Ventilation fans and air filters Infrared and electric heating Humidification Electric controls for heating systems M. Refrigeration and Air conditioning; Systems and Auxiliaries i. Refrigerants; CSA B-52, safety i Compression Refrigeration Systems Refrigeration compressors Heat exchangers for refrigeration systems v. Cooling towers v Refrigeration system auxiliaries Elementary air conditioning systems and auxiliaries 2017-09 AB-55, Edition 1, Revision 1 Page 6 of 7

N. Refrigeration and Air conditioning Controls i. Refrigeration cycle controls i Compression refrigeration system pre start-up checks Compression refrigeration system operation and shut-down Refrigeration system metering devices and capacity controls O. Air Compression i. Types of air compressors i Components of air compressors Auxiliaries used with air compressors Operation and maintenance of air compression systems v. Thermoil Systems Micro-turbine Co-generation P. Electricity i. Emergency generators: start-up, operation, shut-down, safety i Introduction to electricity Lighting systems: incandescent, fluorescent Electrical safety, simple circuits, switches and fuses 2017-09 AB-55, Edition 1, Revision 1 Page 7 of 7