ROLLING STEEL FIRE DOORS. Wayne-Dalton FireStar Rolling Steel Fire Doors provide a practical and innovative solution to safety and fire protection.

Similar documents
FIRESTAR 700C SERIES 700C ROLLING STEEL FIRE DOORS INSULATED STEEL FIRE DOORS CUT YOUR TOTAL COST

FIRESTAR FIRESTAR. Architect Resource Center. FireStar Slat Profiles

SECTION OVERHEAD COILING FIRE DOORS

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

SECTION Overhead Coiling Doors

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

MD Series MEDIUM DUTY SERVICE DOORS. superior product + recognized value

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

R OL L ING F IR E DOOR T E S T ING P R OGR AM

FireCurtain STANDARD, gray, with steel slats UL & C-UL LISTED. Phone: RAYNOR Fax:

ROLLING SERVICE FIRE. Product Line COUNTER FIRE INTEGRAL FRAME & SILL FIRE INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

FIRE DOOR CLOSING SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION AIR DUCT ACCESSORIES

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Hand Chain (Model FCF) &

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION AIR DOORS

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

National Reach. Local Service.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION AIR COILS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION (15833) - HVAC POWER VENTILATORS

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

NFPA 80 Overview January 21, 2016

ARCHITECTURAL SPECIFICATIONS

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

Equipment Specifications

Design & Construction Standards, Revised January

B L I N D S 2 ALUMINUM HORIZONTALS. Motorization - Cut Sheets - Specifications

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

MacroAir AirElite HVLS Fans

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION AUTOMATIC TRANSFER SWITCHES

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

FIRE SUPPRESSION SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

D. Reference Standards (Utilize latest editions available):

C. Samples for Initial Selection: For units with factory-applied color finishes.

Architectural 3-Part Specifications

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

SECTION (15820) - AIR DUCT ACCESSORIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

15900 HVAC INSTRUMENTATION AND CONTROLS

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Across-the-Line SERIES MP300 Combined Manual and Automatic

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Submittal Data Performance Data Electrical Data

STR-Series Indirect-Fired Air Turnover Units

DIVISION 10 SPECIALTIES

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

SECTION STEAM CONDENSATE PUMPS

Lubrication Tools and Equipment Portable Oil Drains

SECTION AIR HANDLING UNIT

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

Rolling Door Parts Program Information Package

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

Soft Start Series MP700 Solid State, Reduced Voltage

Standards in Security Shutters & Fire Shutters (UK & USA)

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

SECTION FIRE-SUPPRESSION STANDPIPES

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

ADDENDUM NO. 3 March 19, 2018

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

A. Provide products and workmanship in accordance to: (Where applicable)

SECTION HVAC Fans

Transcription:

F I R E S T A R 700 FIRESTAR 700 SERIES ROLLING STEEL FIRE OORS W A N E - A L T O N C O M M E R C I A L O O R S S T E M S THE INUSTR S MOST INNOVATIVE FIRE OOR Wayne-alton FireStar Rolling Steel Fire oors provide a practical and innovative solution to safety and fire protection. FireStar doors can be drop-tested and reset at any time by anyone, such as a facility manager or maintenance supervisor, thanks to a standard auto-reset feature. The FireStar door features a forward-thinking design that outperforms industry standard fire doors in all areas, including auto-reset testing capability; smooth, quiet operation; and reliable, long-lasting performance. S UP TO 24 WIE AN 24 HIGH EAS TO TEST WITH STANAR AUTO-RESET QUIET OPERATION UL / FM RATE CONFORMS TO NFPA STANAR 80 (NATIONAL FIRE PROTECTION ASSOCIATION)

700 SERIES FireStar rolling steel fire doors are a simple and innovative solution for your safety and fire protection needs. Critical elements necessary in the reliable function of fire doors are incorporated as standard features with FireStar s revolutionary design. Safety The FireStar door can be drop tested easily and reset in a matter of seconds at any time; no tools or service technicians are required. Please note that this can be done in addition to the door s required annual inspection by a trained door systems technician. By self-testing throughout the year, facility personnel can be even more confident that their door will function safely in the event of fire. The drop-out mechanism is designed to eliminate down time during drop testing while the viscous governor technology results in smoother, quieter door operation. Reliability FireStar s revolutionary design uses a patent-pending planetary gear on the drop-out mechanism ensuring years of reliable service and drop-out performance. Factory tested and approved for a minimum of 20,000 cycles, the FireStar door can be used and tested on a regular basis without concerns of premature failure. Test evice FireStar doors feature an easy-to-use release handle. FireStar oor Control evice FireStar fire doors have been tested and approved to meet the requirements of well known agencies, such as Underwriters Laboratories and Factory Mutual, and conform to NFPA Standard 80. Simplicity Wayne-alton incorporates one standardized component design for all FireStar doors regardless of size, and utilizes fewer parts than other models.this helps to ensure more accurate installations and reduces the possibility of potential service calls in the future. And as an added benefit, eliminating one of the fusible link cables helps the door and surrounding area look cleaner and less cluttered. It also reduces the risk of cable interference with other nearby fixtures. Patent pending. Patent pending. Patent pending. Revolutionary Fire oor control device utilizing a planetary gear arrangement to disconnect the operator and drop the door in the event of a fire. Easily drop test and reset a fire door without resetting spring tension and rerouting cables. Utilizes a viscous governor to drop the door with minimal noise and vibration. Features Easy testing and auto-reset Innovative planetary gear design approved and tested for a minimum of 20,000 cycles Preassembled drop-out mechanism Viscous governor technology Single fusible link cable routing Standardized component design for all door sizes Chain hoist or motor operated Available with left-hand or right-hand operation UL / FM approved www.wayne-dalton.com/commercial

700 SERIES CHAIN HOIST OPERATION LEFT OPENINGWITH A RIGHT 2" AJUSTING WHEEL HOO LINTEL 13" 2 13" HAN CHAIN B ELEVATION SECTION (UNER LINTEL) SECTION BRACKET MOUNTE POWER UNIT 6" BRACKET OPENINGWITH A 10" BRACKET 17" POWER UNIT 2" AJUSTING WHEEL HOO 30" POWER UNIT 30" 2" POWER UNIT LEFT GUIE LINTEL EMERGENC HOIST RIGHT GUIE B 17" OPENING HEIGHT "F" B ELEVATION SECTION (UNER LINTEL) SECTION ANGLE GUIES - FACE MOUNTE TO MASONR ANGLE GUIES - MOUNTE BETWEEN JAMBS OPENING WITH "A" 700 Series oor JAMB JAMB 1/4"+G OPENING WITH "A" ANGLE GUIES - FACE MOUNTE TO STEEL 1/4"+G G 2 7 8" 2 13 16" 3 1 4" WITH TO 13'6" WITH TO 20'0" WITH TO 24'0" WITH L G CLEAR OPENING NOTE: imensions are for general reference only and not for construction purposes. G R 1/4"+G OPENING WITH "A" 1/4"+G COMMON GUIE MOUNTING OPTIONS

ACCESSO RIES WayneGuard Release Systems Horns and Strobes Smoke etectors SLAT PROFILES No. 4 Curved-faced single crown slat available in up to 18-gauge steel or stainless steel. epth of crown: 7 8", 2 5 8" on centers. No. 14 Flat-faced slat available in up to 18-gauge steel or up to 18-gauge stainless steel. epth of crown: 3 4", 2 7 16" on centers. No. 2 Curved-faced single crown slat available in up to 20-gauge steel or stainless steel. epth of crown: 1 2", 1 7 8" on centers. No. 17 Flat-faced slat in up to 20-gauge steel or stainless steel. epth of crown: 1 2", 1 7 8" on centers.

700 SERIES 700 Series (Face Mounted) HEIGHT B (OPENING HEIGHT) Width A BRACKET 9'0" TO 14'0" TO 18'0" TO 24'0" SIE ROOM R L R L R L R L The oor & Access Systems Manufacturers Association (ASMA) supports periodic inspection of Fire oor assemblies as stated in the National Fire Protection Association Standard 80. 2" SLAT TO 20'0" 16 1 2" 15" 10" 6" 18 1 2" 17" 10" 6" 20" 19" 10" 6" 22" 21" 10" 6" 3" SLAT TO 24'0" 16 1 2" 15" 10" 6" 20" 19" 10" 6" 22" 21" 10" 6" 24" 23" 10" 6" 700 Series (Between Jambs Mounted, Under Lintel) HEIGHT B (OPENING HEIGHT) CLASSI FIE U C L US FIRE RATING: ROLLING FIRE OOR NO. HRS SERIAL NUMBER: ROLLING OOR IVISION 14512 LINCOLN WA E. ALTON, OH 44618 028-0110-04 CLASSI FIE U C L US FIRE RATING: OVER ROLLING FIRE OOR NO. HRS ECEPT FOR AN TEMPERATURE RISE, THIS OOR HAS BEEN MANUFACTURE IN COMPLIANCE WITH UL LISTING FILE R107 AN TO THE REQUIREMENT FOR OORS OF THIS CLASS AN TPE. SERIAL NUMBER: ROLLING OOR IVISION 1451 2 LINCOLN WA E. ALTON, OH 44618 028-0109-04 UNERWRITERS' LABORA TORIES OF CANA LISTE HOMOLOGUE FIRE OOR RATING PORTE COUPE-FEU UL C UREE: 3 HR. NO. INUSTRIES CORPORATION LIMITE CAMBRIGE ONTARIO 9'0" TO 14'0" TO 18'0" TO 24'0" Width A BRACKET SIE ROOM R L R L R L R L 2" SLAT TO 20'0" 16 1 2" 15" 7-1 16" 9-1 16" 18 1 2" 17" 7-1 16" 9-1 16" 20" 19" 7-1 16" 9-1 16" 20" 19" 7-1 16" 9-1 16" 3" SLAT TO 24'0" 16 1 2" 15" 7-1 16" 9-1 16" 18 1 2" 17" 7-1 16" 9-1 16" 22" 21" 7-1 16" 9-1 16" 24" 23" 7-1 16" 9-1 16" 20'0" TO 24'0" 16 1 2" 15" 7-1 2" 10-1 4" 18 1 2" 17" 7-1 2" 10-1 4" 22" 21" 7-1 2" 10-1 4" 25" 25" 7-1 2" 10-1 4" NOTE: imensions are for general reference only and not for construction purposes.

FIRESTAR 700 SERIES Note to specifiers: Words in brackets indicate frequently specified and highly recommended options. PART I GENERAL 1.01 Work Included A. The opening will be equipped withwayne-alton 700 Series rolling doors. 1.02 Related Work A. Opening preparation,miscellaneous or structural metal work,access panels,finish or field painting, field electrical wiring,wire,conduit,fuses,and disconnect switches are in the Scope ofwork of other divisions or trades. 1.03 Reference Standards A. ANSI/ASMA 204 American National Standards Institute Specifications for rated fire rolling doors published by oor & Access Systems ManufacturersAssociation International. B. ASTM A123 Zinc [hot-dipped galvanized] coatings on iron and steel products. C. ASTM A229 Steel wire,oil-tempered for mechanical springs.. ASTM A-653-94 Steel sheet,zinc-coated [galvanized] by the hot-dipped process, commercial quality. E. UL10B Underwriters Laboratories (UL) FireTests of oorassemblies F. NFPA 80 National Fire ProtectionAgency Fire oors and Other Opening Protectives 1.04 Quality Assurance A. Rolling doors and all accessories and components required for complete and secure installations shall be manufactured as a system from one manufacturer. 1.05 Systems escription A. Rolling oor:type: Model 700 B. Mounting:[steel][masonry][drywall over minimum 16-gauge steel studs or wood studs] jambs C. Operation:[chain hoist] [motor] [motor with chain hoist]. Material:Galvanized steel with polyester finish paint 1.06 Submittals A. Shop rawings:clearly indicate the following: 1. All details required for complete operation and installation. 2. Hardware locations. 3. Type of metal and finish for door sections. 4. Finish for miscellaneous components and accessories. B. Product ata:indicating manufacturer s product data,and installation instructions. B. Bottom Bar will consist of two equal steel [stainless steel] angles,.121" minimum thickness,to stiffen curtain,with optional astragal. When required for additional security, provide [slide bolts] [cylinder locks] on the bottom bar operable from [coil side] [both sides]. 2.02 Guides A. Guides will be roll-formed steel structural grade,three angle assembly of steel [stainless steel] to form a slot of sufficient depth to retain curtains in guides and to allow expansion at all bolt connections. (Perimeter brush seals may be installed to reduce smoke/air infiltration around door opening) 2.03 Brackets A. Brackets will be of 3/16 [1/4"] minimum thick steel plates,with permanently sealed ball bearings.esigned to enclose ends of coil and provide support for counterbalance pipe at each end. 2.04 Counterbalance A. Curtain to be coiled on a pipe of sufficient size to carry door load with deflection not to exceed.033" per foot of door span and to be correctly balanced by helical springs,oil tempered torsion type.cast iron barrel plugs will be used to anchor springs to tension shaft and pipe. 2.05 Hood A. Hood will be minimum 24-gauge [galvanized] [stainless steel] sheet metal,flanged at top for attachment to header and flanged at bottom to provide longitudinal stiffness.hood will enclose curtain coil and counterbalance mechanism. All FM hoods will be furnished with a steel hood baffle. 2.06 Finish A. Shop coat of rust inhibitive primer on non-galvanized surfaces and operating mechanisms.guides and bracket plates will be coated with a flat black prime paint.stainless steel finish available.curtain color will be [white] [blue] [gray] [beige] [brown](white,blue, beige,brown only available as 22 gauge).powder coating is available in 180 colors. 2.07 Operation A. oor will be operated by means of [chain hoist with gear drive reduction] [motor operation]. Optional [electrical] [pneumatic] sensing edge to be attached to bottom bar to [stop] [stop and reverse] the door when it contacts an object during the closing cycle. 2.09 Governor A. If required by the size of the door,a viscous governor will be furnished to regulate the rate of descent of the door in a quiet manner. It will be the engagement type which is not engaged during normal door operation,but which after cable release,will retard the speed during automatic door closure to under 2 per second and not less than 6 per second. 2.10 Labels A. Rolling fire doors will bear the ¾ (three-quarter) hour,1 1 2 (one and one-half) hour,3 (three) hour or 4 (four) hour label provided they are <= 12 high, <= 13 6 wide. They will bear an oversize tag if they are over 12 high or 13 6 wide.rolling fire doors will be manufactured in strict accordance with the requirements of Underwriters Laboratories-listed procedures or Factory Mutual-approved procedures, and will bear the UL or FM label (tag). FM label is available for the 3-hour fire door only. 2.11 Locking A. [Chain-hoist door will have chain keepers suitable for padlocks by others.] [Electric-motor operation doors will lock through the operator gearing.] [Cylinder locks can be provided with the doors.] Note: When specifying locks on electric-motor operated doors,electric interlocks should also be specified to prevent operation when lock bolts are engaged in the guides,thus preventing damage to the curtain and/or operator. PART III EECUTION 3.01 Installation A. General: 1. Install the rolling fire doors in accordance with Wayne-alton Corp.instructions and standards and in accordance with the standards of the National Fire ProtectionAssociation Standard 80 (NFPA 80).Installation and annual maintenance will only be by a trained door systems technician. 2. Verify that existing conditions are ready to receive rolling door work. 3. Beginning of rolling door work means acceptance of existing conditions. B. Fit,align,and adjust rolling door assemblies level and plumb for smooth operation. C. Upon completion of final installation,lubricate,test and adjust doors to operate easily,free from warp,twist or distortion and fitting for entire perimeter. Note: Architect may consider providing a schedule when more than one rolling door or opening type is required. 1.07 elivery, Handling, Storage A. eliver products in manufacturer s original containers,dry,undamaged,seals and labels intact. B. Store and protect products in accordance with manufacturer s recommendations. 1.08 Warranty A. Standard manufacturer s one year warranty against defects in material and workmanship. PART I I PROUCTS 2.01 Curtain A. Curtain will be composed of interlocking curved [flat] slats [22,20,18 gauge galvanized steel] [22,20 stainless steel] slats,roll-formed perastm standards.ends of alternate slats will be fitted with metal endlocks. 2.08 Release Mechanism A. oors will be equipped with FireStar release mechanism,requiring only one cable to be routed to the operated side (cable not required to be routed to adjusting wheel side.) oors will close by a thermally actuated link rated at 165 degrees F,or by an optional listed releasing device,or by manually operating the release handle. All spring tension shall be maintained when the release mechanism is activated. After closing by manual operation of release handle,the door shall be able to be reset by one person from one side of the door (re-engaging the release handle). 3.02 Testing A. Rolling steel fire doors will be drop-tested in accordance with NFPA 80 and witnessed,attesting to their successful operation at the time of installation. 3.03 Maintenance A. Per NFPA 80,paragraph 15-2 4.3: All horizontal or vertical sliding and rolling fire doors shall be inspected and tested annually to check for proper operation and full closure.resetting of the release mechanism shall be done in accordance with the manufacturer s instructions. A written record shall be maintained by the building owner and made available to the authority having jurisdiction. Because of continuing product improvements, we reserve the right to change the product specifications and designs without prior notice. istributed By: For technical information, visit: www.wayne-dalton.com/commercial 2008 Wayne-alton Corp. One oor rive Mt. Hope, Ohio 44660 800-255-3046 Mt. Hope, OH alton, OH Trail, OH Pensacola, FL Portland, OR Printed in U.S.A. Item #333069 Revised 4/2008