A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

Similar documents
A Newsletter published by. for Industrial Steam and Power Users

Rental Boiler Specifications (Nebraska Boiler)

Boiler Basics. Design and operation

INDUSTRIAL WATERTUBE BOILERS

Guidelines for Preparing for a Temporary Steam Plant

Solution builder. in energy management.

Biomass Energy Systems

Deaerator. Specifications

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

PACKAGED COMMERCIAL WATERTUBE BOILERS

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Heating Efficiency Program COLORADO

Flameless Technology Demonstration Heater

Originators of the Flexible Water Tube design

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

Boiler MACT Webinar Q/A

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

Thermal Fluid Heaters

The world s standard in efficiency. CBEX FIRETUBE

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

Amec Foster Wheeler- Fired Heater Division

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

Green Energy Engineering, Inc.

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Committee on NFPA 85

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

Considerations for INDUSTRIAL COMBUSTION

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Efficient Steam System Design

MECHANICAL SCIENCE Module 2 Heat Exchangers

Best Practices for Condensing Boilers

You can view our archived webinars by going to

Presentation On Industrial Boiler Operation And Maintenance

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

HCLEARFIRE. High-efficiency, modular steam boiler HP


Summary of 60-Day Notice: Heating Efficiency

CONTROLLING BOILER SWELL AND SHRINK

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices

Improving Fired Heaters Reliability using Inclined Firing Technology

By, Mohammad Sarfaraz Khan DGM (Technical) Faran Sugar Mills Limited Shaikh Bhirkio, District Tando Mohammad Khan, Sindh.

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

IE059: Boiler Control and Instrumentation for Engineers & Technicians

Fuel-Fired Vertical Tubeless Boilers

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

BENSON Boiler Technology

MODULATING CONTROL OF LOW NO X BURNERS

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

tççç= ÜÉ~íáåÖ çéíáçåë

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

ADDENDUM # 2 TO RFP #

INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES

CLASS POWER ENGINEER S CERTIFICATE

CONTENTS. B. System Design and Performance Requirements

SECTION HEATING BOILERS

Information on selection of an economizer, and resulting payback due to changes in inlet water temperature.

Boiler Division HPS. Triveni Boiler

CHAPTER 3 BASIC STEAM CYCLE

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

Natural Gas Savings in Industry

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Super Boiler. > Gas Technology Institute Cleaver-Brooks Inc. May WHO WE ARE Gas Technology Institute

Contact Information. Steven Potratz, P.E. WSU Facilities Services, Engineering Services Manager Phone

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

State-of-the-art Developments to Save Energy in Coating Drying

Improving the Performance and Reliability of Fired Heaters and Boilers

ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

Bosch Commercial and Industrial Heating High efficiency steam boilers (175kg/h to 55,000kg/h)

What to Expect from Your EtaPRO Investment

REFERENCE SYLLABUS. For FOURTH CLASS POWER ENGINEER S. CERTIFICATE of COMPETENCY EXAMINATION. AB-54 Edition 1, Revision 1,

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Tune-Rite Software Operation Manual

IN THE MARINE INDUSTRY

Kieffer s Buying Guide: Wall Ovens

FUEL-FIRED VERTICAL TUBELESS BOILERS

Trends for Radiant Tube Heated Strip Lines

Zeeco recently had the opportunity

Williams & Davis Boilers

Transcription:

ENERGY SOURCE A Newsletter published by ESI The Steam and Power SPECIAL FORCES Spring 2003

THE BUYER S GUIDE TO PACKAGE BOILER DESIGN By: William L. Reeves, P.E., President, ESI Editor s Note: This article is the first in a series on package boiler design. Over ESI s 25 year history, we have purchased and installed numerous package boilers of various steam capacities, design types, and steam pressures and temperatures. The package boiler is the predominant type of industrial steam generator that is purchased and installed when new or replacement steam capacity is required. However, most companies make a boiler purchase so infrequently that they do not have a good working knowledge of potential package boiler manufacturers, types and models offered, critical design features, and what differentiates vendor equipment. This lack of knowledge regarding the design and construction of package boilers places the buyer in a position of relying on the manufacturers for information. This is not a desirable position, because most manufacturer sales representatives are naturally going to try to advance their particular product offering. In this series of articles, ESI will share our knowledge to help make you an informed buyer. The remainder of this article will focus on the types of water tube package boiler designs and how shipping restraints can affect certain design parameters. Package boilers fall into two major classes, water tube and fire tube units. As you would expect, in water tube units, the water is in the tubes and the products of combustion are on the outside of the tubes. In fire tube units, the opposite is true. Because the entire boiler shell is the pressure vessel in fire tube designs, fire tube boilers are limited in their size and design pressure. The maximum size is approximately 50,000 pph of steam capacity with a design steam pressure and temperature generally less than 250 psig saturated. Package boilers are by definition, a complete package that is shop assembled and shipped to the project site. All of the code work is complete and the unit can be installed without any required ASME Section 1 code work performed in the field. Therefore, the fundamental question and requirement of any package boiler designed and built is how and where it must be shipped. While shipping size generally does not cause any technical design issues on smaller lower pressure saturated units, this basic requirement can result in very ENERGY SOURCE The ENERGY SOURCE is published quarterly for customers, employees, and friends of ESI Inc. of Tennessee. ESI is the Steam and Power SPECIAL FORCES providing clients with innovative, cost-effective, and environmentally-friendly solutions. If you have any suggestions or comments about the newsletter feel free to call us at 770-427-6200 or e-mail us at energysource@esitenn.com. Deanna White Managing Editor interesting compromises in the design of larger steam capacity units operating at higher temperatures and pressures. With respect to these units, it is important to realize that good engineering design parameters are being pushed to their upper limits or even compromised by the requirement to be able to ship the unit. Types of Package Boilers Water tube package boilers come in three basic configurations, A, D, and O types. There is a method to this designation madness. Please refer to Figures 1 through 3 for a schematic of each type. Continued on Page 2 ENERGY SOURCE 1

THE BUYER S GUIDE... Continued from Page 1 The predominant type of package boiler that is purchased today is type D. This boiler configuration generally allows a more desirable furnace geometry that is critical to achieving today s lower emission standards. The D type also positions the steam drum off to one side instead of being situated directly over the furnace. This arrangement makes it easier to protect the steam drum with refractory at the tube interfaces and makes it less susceptible to damage from radiant furnace heat in the event of a refractory failure. The D type configuration also makes it easier to accommodate membrane totally water-cooled front and rear wall tube arrangements. This type wall construction requires less maintenance than total or partial refractory walls. The water-cooled front and rear walls also reduce furnace temperatures resulting in lower NOx emissions capabilities. Another advantage of a D type boiler is that it only requires one furnace to boiler bank division wall while the other types require two. The primary disadvantage of D type boilers really disappeared with modern water treatment technology. The D shaped furnace tube design results in a long tube run at the furnace bottom with little slope which exacerbates problems with poor water treatment. The other disadvantages of D type boilers have more to do with general arrangement than operation. These boilers have a side gas outlet that requires more plan area width for installation. Also, the shipping costs of very large D type boilers can be higher as special trailers are required to deal with the eccentric weight distribution. Figure 1. Type A Package Boiler. Figure 2. Type D Package Boiler. The other type of water tube boiler generally used in permanent industrial installations is type A. In type A boilers the two mud drums are Figure 3. Type O Package Boiler. generally much smaller than the single mud drum of a D type boiler, which makes the drum inspections more difficult. The biggest concerns with A type boilers are the floor tubes and end walls. The floor tubes are horizontal which is not ideal in natural circulation boilers. The front and rear walls are generally refractory which create maintenance problems and forced outages. This is especially true with the rear target wall. On a positive note, type A boilers do allow the economizer to be situated directly above the boiler centerline top outlet flue gas connection for a nice clean vertical arrangement with less plan area width requirement. One of the biggest applications of A type boilers is to situate them on top of a refractory furnace for firing solid fuels. In this case, there are no floor tubes between the bottom mud drums and the open furnace bottom between the bottom drums allows the normal boiler furnace to become the upper portion of the total boiler furnace. Continued on Page 4 ENERGY SOURCE 2

ESI Bulletin Board RENTAL EQUIPMENT Available For Rent! Boilers Deaerator Systems Boiler Feedwater Pumps Water Softener Systems Contact Deanna White Today! Check out our rental equipment on the web at www.rentalboilers.com. OPERATOR TRAINING Are Your Operators Properly Trained? ESI offers a comprehensive Operator Training Program which could save your company a great deal of time, money, and could potentially mitigate losses from improper operation of the facility s powerhouse. Our training program consists of three levels of training: Basic Training - Training on powerhouse components including boilers, water treatment systems, steam and combustion turbines, burners, etc. Advanced Training - Training customized for your particular powerhouse facility. ESI will visit your site, then develop a comprehensive training program for your facility. Recurrent Training - Recurrent annual training for your operators, plus ESI will be on-call 24/7 to your operations staff to answer questions and troubleshoot problems. All training programs occur on-site and include a training manual. ENVIRONMENTAL UPDATE The 1970 Clean Air Act has been revised to make it easier for industrial and utility plants to modernize and upgrade equipment. No longer is it required to apply for permits by the New Source Review (NSR) program. The new final EPA regulations clarify that NSR is only triggered when actual emissions increase. If you are confused by constantly changing environmental regulations contact ESI. Our familiarity with all EPA regulations including NSPS, BACT, PSD, and MACT allows us to recommend the most technically and economically feasible air pollution control technology. Contact ESI s STEAM & POWER SPECIAL FORCES Today at 770-427-6200 or info@esitenn.com. DILBERT reprinted by permission of the United Feature Syndicate, Inc. ENERGY SOURCE 3

THE BUYER S GUIDE... Continued from Page 2 Type O water tube package boilers are predominantly used in the rental boiler market. The position of both drums in the boiler center resulting in side to side equal weight distribution makes these boilers ideal for permanent attachment to tractor trailers for use in the rental fleets. This centerline equal weight distribution also holds true for A type boilers. Regardless of which type of boiler is purchased, it is critical that the furnace division walls be of welded membrane tube construction (little or no refractory). This design prevents flue gas bypassing from furnace to boiler outlet which results in higher CO emissions, a problem with other types of furnace division wall construction. Another critical construction feature is to make the boiler side walls, end walls, and roof welded membrane type construction to the maximum extent possible. Membrane tube wall enclosures eliminate casing bulges, hot spots, and other problems created by moderate furnace pressure excursions. This design also mitigates the use of refractory, which is the primary maintenance item in package boilers. Shipping Restraints Since the most expensive part of any boiler is the steam and mud drum costs, it makes sense that the design of any boiler will seek to reduce the length of these drums. Accordingly, the length of any package boiler is designed to be as short as possible after consideration of the furnace length to achieve optimum burner performance and complete combustion. Therefore, in package boiler design, the height and width is less dependent upon steam capacity while the length is the primary variable affected by steam capacity. An 80,000 pph shop assembled package boiler can easily be designed and shipped to essentially anywhere with a conservative furnace heat release of below 70,000 btu/cuft hr. The unit can also be designed to have a very desirable gas side pressure drop resulting in relatively low FD fan operating horsepower. Conversely, a 200,000 pph boiler operating at 650 psig/750ºf will have a considerably higher furnace heat release rate and pressure drop as the unit gets longer. The gas weight and volume of the larger unit is roughly 2.5 times that of the smaller unit. Accordingly, since both boilers will have close to the same height and width and since pressure drop is a square function of flow, assuming the boiler tube spacing is the same, the larger unit will have a pressure drop equal to 5-6 times that of the smaller unit. Since both boilers will have a burner on one end, the larger unit will have a much higher heat gradient through the furnace tube walls in the burner zone of the furnace due to the much higher burner heat input. Good design requires that the burner produce a flame shape that it is long and narrow; therefore, avoiding flame impingement on furnace tubes. This technology has its limits, as the boiler grows very long in larger sizes and capacities. However, the heat input of the larger unit is still roughly 2.5 times the heat input of the smaller unit and shipping restraints make it virtually impossible to achieve 2.5 times the furnace tube wall heating surface. The net result of this larger boiler is a boiler with a very high furnace tube wall heat gradient, a much higher furnace heat release rate, and a high pressure drop resulting in high fan horsepower and operating costs. Shipping and handling a very large and heavy shop assembled package boiler can be very expensive. Sometimes, it is virtually impossible to ship such a boiler to certain parts of the country. When the shipping and handling costs are properly evaluated against the cost of field erecting a package boiler, it is often a better technical and economic decision to purchase the boiler for complete or partial field erection. ESI performed a project that included a package boiler of 250,000 pph steam capacity operating at 350 psig/550ºf. The shipping and handling costs were extreme and the Continued on Page 5 ENERGY SOURCE 4

THE BUYER S GUIDE... Continued from Page 4 gas side pressure drop was very high on the shop assembled unit being considered. Once ESI properly evaluated all the shipping, handling, and higher operating costs against the field erection cost, the decision was made to field erect the unit. Not bound by shipping restraints, the design of the unit resulted in wider boiler tube spacing in the convection section thus reducing the gas side pressure drop by 65%. The furnace was designed for a heat release rate below 72,000 btu/cu-ft-hr as opposed to a rate over 100,000 btu/cu-ft-hr for the shop assembled unit. The field erected boiler was much more conservative than the shop assembled unit due to the increased width and height of the boiler. For essentially the same total capital cost, the end user received a boiler with much lower operating and maintenance expenses. Large boilers operating at a steam pressure in excess of 800 psig are good candidates for total or modular field erection for another reason. As the operating pressure exceeds 800 psig, the specific volumes of the steam and water start to converge dramatically. For example, the ratio of the specific volumes of steam to water for a boiler operating at 150 psig is 152. This same ratio for a boiler operating at 900 psig is only 23. Circulation design of natural circulation boilers is dependent upon this ratio. Circulation can be improved by increasing the height distance between the steam and lower drum and headers. This can be achieved through complete or modular field erection. The bottom line regarding shipping restraints is that any shop assembled package boiler that is purchased to operate above 175,000 pph and at higher steam temperatures and pressures should be thoroughly evaluated considering all the design and operating cost parameters. The benefits of field erection in the boiler design should be explored. The fact that the manufacturer can shop assemble and deliver the unit does not necessarily mean that it is the best long term design or the best value. We hope you enjoyed the first article in this series. Stay tuned for the Summer 2003 issue of the ENERGY SOURCE where we will continue The Buyer s Guide To Package Boiler Design. Please remember, if your steam or power facility needs additional capacity, contact the Steam & Power SPECIAL FORCES today at 770-427-6200 or info@esitenn.com. Since ESI has no particular allegiance or vested interest in any specific manufacturer, we can select the best technology for your particular application. THE BUYER S GUIDE TO PACKAGE BOILER DESIGN Yet to come... This series of articles will answer the following package boiler design questions: What critical boiler design parameters should be considered when purchasing a new package boiler? What is the current state of burner technology and typical emissions firing natural gas and fuel oil? What factors really determine boiler efficiency and is there any real difference between manufacturers? What are the critical considerations in the design of an economizer, fan, burner management system, boiler trim, and other boiler auxiliary equipment? ENERGY SOURCE 5