COMBINED CONTRACT Nov. 10, NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL

Similar documents
Lake County / Multi-Department Storage Facility / Project / December 05, 2016 SECTION DOOR HARDWARE

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

SECTION FINISH HARDWARE

Architect s Specification Guideline:

ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA

THE LEDGE AT CABOT DRIVE. NASHVILLE, TN

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE

C. Thresholds, weatherstripping, seals and door gaskets. A. ANSI/ICC A117.1 Standard for Accessibility and Usable Buildings and Facilities; 1998

New Bedford, Massachusetts Tel: (617) CBI Job No.: Fax: (617)

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

SECTION INTEGRATED DOOR ASSEMBLIES

Security & Life-Safety For Schools

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

Security & Life-Safety For Schools

Doorway Solutions for Multi-Resident Facilities. Apartments, Condominiums, Mixed Use & Assisted/Senior Living

v.3.1: December 19, 2014

SEQUOYAH SCHOOLS FI&R 06 G01 Cherokee Nation Tahlequah, Oklahoma

BuildingName The Description of the Project P DOCUMENTS

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

This Addendum consists of [2] pages, Pre-bid attendance, [1] Revised Bid Form, [1] revised Hardware Groups and [1] 30 x 42 drawings.

April 2, 2019 ADDENDUM NO. 3 DEPARTMENT OF PUBLIC WORKS OPERATIONS BUILDING

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

HALIFAX HUMANE SOCIETY ADDITIONS AND ALTERATIONS. B. See Division 08 door sections for astragals and door silencers.

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

SECTION &.40 DOOR HARDWARE

University of Rochester October 17, 2008 Brooks Landing Business Center

Alarmed Exit Hardware

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

ALARMED EXIT HARDWARE

SECTION HARDWARE

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

SECTION DOOR HARDWARE

Become a Door Security. Solutions Expert

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

EHT/EHTD. Electromechanical Closer-Holder Release Devices

Behavioral Health Series

ABLOY EFEND. New name for security

Behavioral Health Series

SECTION DOOR HARDWARE

Integrated Door Systems

The Fairmont Hotel Pittsburgh, PA

FLASHship. July 2018 Vol. 1

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DESIGN GUIDELINES AND STANDARDS

2. Interior doors shall be not less than 18 gauge steel.

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE

Enhancing Your Guests Experience. Doorways With Allure

DOOR HARDWARE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

About the Instructor & Presenter:

FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) DOOR HARDWARE PREPARATIONS

Card Access Control Specifications

Solutions for Hospital & Healthcare Facilities

BIDDER MUST ENTER THE NUMBER OF THIS ADDENDUM ON HIS PROPOSAL SHEET

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

Addendum No. 2: JEFFERSON HIGH SCHOOL ADDITIONS AND RENOVATIONS

FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS. A. Provide finish hardware including necessary accessories.

ABLOY FIRE DOOR CLOSING SYSTEMS

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project and Confirm with University Lock Shop]

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Panic & emergency exit devices

System Design and Overview Document

Delta Mills ECC Remodeling Project Interior and Exterior Renovation BID PACKAGE RELEASE NUMBER: 1 CLARK PROJECT NO:

Demountable Office Fronts. A Sustainable Interior Design Solution

Panic & emergency exit devices. CFPA-E Guideline No 2:2013 F

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

APPENDIX F: LOCKSETS AND ACCESS CONTROL

8/9 Line. Bored Knob Locks

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

Behavioral Healthcare Door Opening Solutions

ADDENDUM #3. Chauncey Wilmore Senior Procurement Officer March 22, 2016 ALL PROSPECTIVE FIRMS

2409/2900. Fire Guard

Glass Solutions Sweets Brochure

Feb H: FINISH HARDWARE

ONYX FirstVision Specification Interactive Firefighters Display

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

2408/2900. Fire Guard

SMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Door Closers. DURO/ Dark Bronze. Alum

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

Finnish American architect, Eero Saarinen, may be best known for his big, bold, bending forms the Gateway Arch, the Dulles and TWA terminals.

1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated.

PIVOT Architecture 44 West Broadway Suite 300 Eugene, OR t f pivotarchitecture.com

SECTION LOW VOLTAGE LIGHTING CONTROLS

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

EPlex 5000 Series MONACO LOCK COMPANY, INC. TEL (800) FAX (800)

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

Q1000 Series exit Devices

CFAA Technical Seminar Ontario Building Code Updates to 2015

Transcription:

ADDENDUM NO. CC-1 STATE OF NEBRASKA 501 BUILDING RENOVATION DATA CENTER RENOVATION & BRASKA DLR GROUP PROJECT NO. 10-16206-00 Architecture Engineering Planning Interiors 6457 Frances Street, Suite 200 Omaha, NE 68106 tel 402/393-4100 fax 402/393-8747 omaha@dlrgroup.com www.dlrgroup.com COMBINED CONTRACT Nov. 10, 2017 NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL ITEM NO. 1 SECTION 087100 DOOR HARDWARE A. Delete Hardware Sets 1 7 and substitute new Hardware Sets 1-6 as found on Attachment 087100-1, dated Nov. 10, 2017. DRAWINGS ITEM NO. 1 DRAWING E7.1 ELECTRICAL SCHEDULES A. Change Light Fixture Schedule as shown on Attachment E7.1-1, dated Nov. 10, 2017. END OF ADDENDUM ADDENDUM NO. CC-1 CC-1-1

1. MK - McKinney 2. RO - Rockwood 3. SA - Sargent 4. SU - Securitron 5. HS - HES 6. RF - Rixson 7. PE - Pemko Attachment 087100-1 to Addendum No. CC-1 dated November 10, 2017 Hardware Sets Set: 1.0 Doors: 105, 106, 110A, 110B 1 Door & Hardware By Owner (NIC) Set: 2.0 Doors: 101 3 Hinge TA2714 x NRP 4-1/2" x 4-1/2" US26D MK 1 Magnetic Lock (push side) By Owner's Security System Provider SU 1 Passage Set 28 10U15 LL US26D SA 1 Door Closer 281 P10 EN SA 1 Wall Stop 409 US32D RO loss of power door will become or remain secured to prevent access by battery backup. In the event of a fire alarm activation door will become unsecured for emergency egress. Key override by key switch is available for emergency access. Free egress is always available from inside.

Set: 3.0 Doors: 103, 218 3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Magnetic Lock (pull side w/ z bracket) By Owner's Security System Provider SU 1 Passage Set 28 10U15 LL US26D SA 1 Door Closer 281 PS EN SA loss of power or fire alarm activation door will become or remain secured to prevent access by battery backup. Key override by key switch is available for emergency access. Free egress is always available from inside. Set: 4.0 Doors: 110 3 Concealed Hinge 218 3 Metal Door Hinge Reinforcement 218SDB 2 Concealed Shear Magnetic Lock By Owner's Security System Provider SU 1 Push Plate 70F US32D RO 1 Flush Pull 95B US26D RO 1 Door Closer 281 PS EN SA

loss of power door will become or remain secured to prevent access by battery backup. In the event of a fire alarm activation door will become unsecured for emergency egress. Key override by key switch is available for emergency access. Free egress is always available from inside. Set: 5.0 Doors: 101A, 101B, 202, 203, 302, 303, 402, 403 3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Plate 70F US32D RO 1 Pull Plate BF 110x70C US32D RO 1 Door Closer 281 O EN SA 1 Wall Stop 409 US26D RO 3 Silencer 608 RO

Set: 6.0 Doors: 107A 6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Flush Bolt (set, self-latching) 2845 US32D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom Lock 28 72 737P 10G04 LL US26D SA 1 Coordinator & Accessories 2672 Black RO 2 Door Closer 281 PSH EN SA 2 Armor Plate K1050 36" x 1" LDW US32D RO 1 Astragal S772D PE Mark Hardware 101 2.0 101A 5.0 101B 5.0 103 3.0 105 1.0 106 1.0 107A 6.0 110 4.0 110A 1.0 110B 1.0 202 5.0 203 5.0 218 3.0 302 5.0 303 5.0 402 5.0 403 5.0 END OF SECTION 087100