Dräger X-pid 9000 / 9500 Multi-Gas Detection

Similar documents
Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 5500 Single-Gas Detection Device

Dräger Bump Test Station Calibration and Bump Testing

Dräger Polytron 5720 IR Toxic Gas Detection

Training Gas Detection Level 3 Maintenance and Repair

On-site & Shutdown Safety Service CSE Monitoring

Dräger PIR 3000 Detection of flammable gases and vapours

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Catalytic Ex-Sensors DrägerSensors

Training Authorised Gas Tester Level 1. Basic Information

Dräger X-zone 5500 Area Monitoring

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger X-am 2500 Multi-Gas Detection

Dräger Configuration and Evaluation Software

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-am 5000 Multi-Gas Detection

Dräger Pac 6000 Single-Gas Detection Device

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger REGARD -1 Control System

Dräger Bodyguard 1000 Warning Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 8500 Single-Gas Detection Device

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Pac 3500 Single-Gas Detection Device

Powder Extinguisher ABC - composite Portable powder extinguishers

Dräger Pac 7000 Single-Gas Detection Device

Portable wet chemical extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger REGARD 3900 Series Control System

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Flame 5000 Flame Detection

Dräger X-am 5000 Multi-Gas Detector

Dräger VVP 1000 System Components

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

The SharpEye 40/40I (IR3) Flame Detection

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger X-am 7000 Multi-Gas Detection

Dräger QuadGard Control System

Dräger X-am 5000 Multi-Gas Detection

GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

VarioVac vacuum regulators Consumables and Accessories

Dräger PEX 3000 Flammable Gas Detection

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Flame 5000 Flame Detection

Dräger OR Lights Simply good light

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8200 Stationary gas detector (CatEx)

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Tropic 2.0 ultrasonic nebuliser

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger PIR 7000 Flammable Gas Detection

Oxylog VE300 Emergency & Transport Ventilation

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Oxylog VE300 Emergency & Transport Ventilation

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Polytron 8000 Stationary gas detector (EC)

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger Flame 2100 (UV) Flame Detection

Dräger Pac 6000 Single-Gas Detector

The SharpEye 40/40R (IR) Flame Detection

Dräger Pac 8500 Single-Gas Detector

D Moving beyond telemetry INFINITY M300

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger REGARD -1 Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger P4000 Pressure and Leak Testing

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger Pac 3500 Single-Gas Detection Device

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Flame 2500 Flame Detection

Dräger REGARD -1 Control System

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Flame 2100 Flame Detection

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Transcription:

Dräger X-pid 9000 / 9500 Multi-Gas Detection The selective PID gas measurement device is ideal for users who frequently test for hazardous toxic substances Benzene, butadiene and other volatile organic compounds (VOCs) are carcinogenic even in the smallest concentrations Selective measurement is necessary because other gases and vapours are often also present Our X-pid gas measurement device allows for short test times and laboratory-quality results Sensor unit compiles measurement values and sends raw data via Bluetooth to the Ex smartphone Integrated photoionisation detector (PID) for measuing in the low ppb range Ex smartphone with large touch screen and connectivity via WLAN and GSM D-18382-2017 Integrated gas chromatography (GC) to seperate and analyse speciic substances in gas-vapour-mixtures Connection to internal pump for attaching a hose of up to 10 m length Mobile app allows intuitive handling and eicient measurement data analysis

02 Dräger X-pid 9000 / 9500 Benefits Two modes for an efficient measurement strategy Seeker mode is a broadband measurement for pre-testing and localising measurement points It allows continuous, direct-reading measurement of the total concentration of all VOCs present Seeker mode is similar to using a single-pid gas measurement device Analysis" mode allows selective measurement for monitoring specific hazardous substances Pre-defined target substances can be precisely measured in seconds Analysis mode is similar to gas chromatography analyses conducted in the laboratory Up to 90% time savings The Dräger X-pid 9000 / 9500 requires no preparation and is ready to use after a brief warmup period Selective measurement in analysis mode takes only a few seconds Benzene measurement starts with the push of a button and is finished in 30 seconds After another 60 seconds, the device is ready to measure for benzene again Compared with other detection systems, the Dräger X-pid 9000 / 9500 saves considerable time and enables further monitoring to be undertaken Simultaneous measurement of other substances, like benzene and butadiene, further reduces testing times Cost savings starting at one measurement per work day Because no consumables are used to take measurements, operating costs can be reduced For users with high measurement needs, the Dräger X-pid 9000 / 9500 quickly pays for itself For example, it requires no pretubes, also making it easier to use and preventing user errors On the basis of 200 measurements per year, the Dräger X-pid 9000 / 9500 is generally more cost-effective than comparable measurement systems High selectivity for greater safety Selective measurement relies on technology which separates individual substances present in mixed gases This makes it possible to conduct a substance-specific measurement for benzene, even if other VOCs like toluene and xylene are also present in high concentrations Cross-sensitivities are reduced to a minimum This reduces the number of false-positive measurement results and false alarms Reliable performance under tough conditions The influence on measurement results by environmental factors like variable ambient temperature or high humidity are reduced to a minimum The sensor unit maintains a constant temperature above the ambient air temperature and separates water vapour from the target substances This ensures reliable measurements under tough environmental conditions

Dräger X-pid 9000 / 9500 03 Benefits Low detection limits Concentrations of hazardous substances in the air at work sites must not exceed threshold limit values Mandatory time-weighted averages in the low ppm to ppb range need to be performed for carcinogenic vapours like benzene The Dräger X-pid 9000 / 9500 is optimised for measuring in this concentration range and its detection limit for benzene is as low as 50 ppb Intuitive handling with explosion-proof smartphone The sensor unit is controlled and the measurment data analysis is conducted by a mobile app installed on an explosion-proof smartphone (delivery includes both) The large touch screen and familiar user interface elements are easy to use This makes the sophisticated technology accessible to a broad group of users No prior knowledge or extensive training is required Laboratory-quality measurement results The gas measurement device is based on gas chromatography (GC) and photoionisation detection (PID) technologies These technologies, used widely in laboratories, have a high acceptability due to their excellent analytical performance The Dräger X-pid 9000 / 9500 brings these technologies directly to the hazardous area of any production site Simple bump test and calibration For the Dräger X-pid 9000 / 9500, the daily bump test as well as any necessary calibration (adjustment of the device's sensitivity and ability to identify substances) are performed using either a benzene calibration gas cylinder or an isobutylene and toluene calibration gas cylinder Two product versions for different requirements There are two versions of the product: the 9000 and 9500 The Dräger X-pid 9000 covers the target substances benzene and butadiene The Dräger X-pid 9500 offers the possibility of combining more than 15 target substances into individual measurement programmes and thus expanding its application range This means, you can independently expand the target substance database for the Dräger X-pid 9500 through qualified measurements

04 Dräger X-pid 9000 / 9500 Innovative operating design The sensor unit is controlled by a mobile app installed on an explosion-proof smartphone The sensor unit can be worn around the neck, keeping one hand free Accessories Calibration gas and accessories Calibration of equipment will ensure safe operation and functionality of equipment and will also meet with the applicable regulations and codes of practice Various calibration options are easily available ST-5080-2005

Dräger X-pid 9000 / 9500 05 Accessories Case with inlay for Dräger X-pid 9000 / 9500 For convenient transport of sensor unit, explosion-proof smartphone, calibration gas cylinder, chargers and sampling accessories D-4735-2017 D-34536-2009 Sampling probes and hoses Selection of sampling accessories for various applications Services Product Service Our product service department supports you with a range of service packages in our shops or on site in your plant Care, servicing and maintenance are key factors when it comes to safety Diligent maintenance and care is also absolutely necessary from an economics perspective Preventive checks, service procedures and original replacement parts make your investment last longer D-2331-2016

06 Dräger X-pid 9000 / 9500 Technical Data The technical specifications refer exclusively to the Dräger X-pid 9000 / 9500 sensor unit Dimensions (W x H x D) Weight Ambient conditions Protection class Warm-up period Operating times Charging times Approvals Seeker mode 132 x 281 x 56 mm 750 770 g Temperature -10 to +35 C Pressure Relative humidity ATEX IECEx CE Marking Sensors Measuring range Detection limit Resolution Selectivity 700 to 1,300 mbar 10% to 95% RH IP54 10 min 4 to 6 h reduced at low ambient temperatures < 5 h II 1G Ex ia IIC T4 Ga Ex ia IIC T4 Ga RED (Directive 2014/53/EU); ATEX (Directive 2014/34/EU); RoHS (Directive 2011/65/EU) 106 ev PID 0 to 125 ppm isobutylene response 001 ppm 001 ppm (display with three figures) Sum concentration of all compounds with ionisation energy < 106 ev regardless of individual response factors Analysis mode Sensors Measuring range Detection limit Resolution Selectivity Measurement time Target substances 106 ev PID with separation by gas chromatography (operating temperature 40 C, non-polar separating column) Substance-specifc, see Technical Handbook 0 50 ppm for benzene and 0 to 80 ppm for 13-butadiene Substance-specifc, see Technical Handbook 005 ppm for benzene and 010 ppm for 13-butadiene 001 ppm (display with three figures) Substance-specifc, see Technical Handbook For benzene and 13-butadiene, no cross sensitivity to toluene, ethyl benzene, xylene, N-hexane and other VOCs with differing volatility Substance-specifc, see Technical Handbook < 30 seconds for benzene and 13-butadiene Benzene and 13-butadiene for Dräger X-pid 9000 Dräger X-pid 9500 can target other substances on request

Dräger X-pid 9000 / 9500 07 Technical Data List of Dräger X-pid 9500 target substances for Analysis mode Target substances that have already been qualified and can be combined into measurement programmes Chemical compound CAS number Detection limit (ppm) Measurement range (ppm) Acrolein 107-02-8 050 0 100 Benzene 71-43-2 005 0 50 Butadiene, 1,3-106-99-0 010 0 80 Dichloroethane, 11-75-35-4 005 0 40 Dichloroethane (CIS) 156-59-2 005 0 40 Dichloroethane (trans) 156-60-5 005 0 40 Ethyl benzene 100-41-4 010 0 90 Ethylene oxide 75-21-8 080 0 800 Hexane, n- 110-54-3 040 0 360 Isobutylene 115-11-7 005 0 100 Styrene 100-42-5 010 0 70 Tetrachlorethene (Per) 127-18-4 010 0 110 Toluene 108-88-3 010 0 60 Trichlorethene 79-01-6 010 0 80 Vinyl chloride 75-01-4 010 0 100 Xylene (all isomers) 1330-20-7 010 0 110 Ordering Information Description Dräger X-pid 9000 with sensor unit, ex-smartphone with pre-installed mobile app plus power supplies and charging cables Dräger X-pid 9500 with sensor unit, ex-smartphone with pre-installed mobile app plus power supplies and charging cables Order number 68 51 847 68 51 848 Upgrade Dräger X-pid mobile app from version 9000 to version 9500 68 51 849 Test and calibration gas 58 l Isobutylene 10 ppm, Toluene 10 ppm Test and calibration gas 58 l Benzene 5 ppm 68 14 046 68 14 050 Control valve basic 05 LPM; fits to 58 l Test gas cylinder 68 10 397 Dräger X-pid 9000 / 9500 test gas adapter 68 51 850 Case for Dräger X-pid 9000 / 9500 68 51 851 Sampling hose Tygon with inlined PTFE hose Length (3 m); OD: 8 mm; ID: 48 mm; WD: 16 mm Sampling hose Tygon with inlined PTFE hose Length (15 m); OD: 8 mm; ID: 48 mm; WD: 16 mm Sampling hose FKM (solvent resistant) OD: 64 mm; ID: 32 mm; WD: 1,6 mm 83 26 980 45 94 679 83 25 837 Dust and water filter with hose adapter 83 19 364 Dust and water filter w/o hose adapter 83 19 359 Telescopic probe ES 150 Length up to 150 cm with FKM sampling hose extension Bar probe 90 Length: 90 cm with FKM sampling hose extension 83 16 533 83 16 532 Float probe without hose 68 02 337

08 Dräger X-pid 9000 / 9500 Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 91 04 798 1710-2 HQ PP Subject to modifications 2017 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom REGION DACH Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact