TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

Similar documents
FAST RESPONSE TEMPERATURE SENSORS 42.11a

TEMPERATURE SENSORS WITH CONNECTION HEAD FOR EXPLOSION ENDANGERED ROOMS 13.3a

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Gas cylinder scale Model GCS-1

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

for relative humidity and temperature with calibration certificates

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Beck. The differential pressure transmitter for air

Model 144H. Product Data Sheet , Rev DB February Content

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Hygro/hygrothermal transducers (hygrometric)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

RE-PR3-E-27 3-Phase Panel Mount 27kW

Model 144H. Product Data Sheet , Rev DB February Content

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Hygro/hygrothermal transducers (hygrometric)

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Operating Manual MS220KA and MSR220KA

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

DESIGN GUIDELINES. THERMAL building SOLUTIONS

VERSAFLOW VORTEX Supplementary instructions

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Temperature Sensor TRG Original Installation Instructions English

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

WIO200 Water In Oil measuring instrument

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Differential pressure gauge with electrical contact type Model: P650 series

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

MIX Boiler & Font Range Service Manual

Operating Instructions

Analog Room Pressure Monitor RPC Series

FAHM Co. Temperature Transmitter PTT74 Series

02/11/2015

02/11/2015

Inductive slot sensor

for relative humidity and temperature

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

CMT MANUAL 6. NMC SENSORS

USER S MANUAL INTERSYSTEM PRESSURE TRANDUCER TYPE PM-22

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

1. Basic safety information 3 2. Proper use 3

OPTISENS TUR 2000 Technical Datasheet

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

1592P01. for liquids in piping DN

Operating Manual MS220DA

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Advantages / Characteristics

Installation Guide. DEVIreg 610. Electronic Thermostat.

Operating Instructions Edition 02/2007

OPTIBAR P 1010/2010 C Supplementary instructions

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

M7100 Pressure Transducer

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

MP 601A Humidity Probe INSTRUCTION MANUAL

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Installation and Operating Manual

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

SCHMIDT LED Measured Value Display MD Instructions for Use

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

0-10 V Wall & Duct Humidistat Installation Instructions

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Technical Data. General specifications. Rated operating distance s n 5 mm

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Ceiling Mount Temperature Sensor

Transcription:

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurement of gaseous substances. The sensor consists of a metal measuring stem and a plastic connection head. The sensor stem is made of the stainless steel EN X5CrNi18-10 (DIN 1.4301), the stem length is 25 mm. The plastic connection head is provided with a cable outlet bushing (terminal board is located in the head) or a connector. All these sensor types meet the IP 65 ingress protection requirements according to the EN 60 529 standard. The connector ELKA 4012 or connecting cables with the straight-type RKT connector or the rectangular-type RKWT connector can be delivered for the version with connector as accessories. The sensor types can be utilised for outdoors temperature measurement or in industrial areas. The sensors can be utilised for any control system that is compatible with sensing element output signals or active output signals quoted in the table of specifi cations. version A The standard temperature range in which the sensors are allowed to be utilised is -30 to +100 C. The sensors are designed to be operated in a chemically non-aggressive environment. Caution: The temperature sensors with the output 4 20 ma can be delivered with the new connection head only in the version A. version B SPECIFICATIONS BASIC DATA Sensor type (K with connector) NS 110x NS 110xK NS 111x NS 111xK NS 112x NS 112xK NS 310x NS 310xK NS 311x NS 311xK Type of sensing element Ni 1000/5000 Ni 1000/6180 Ni 891 Ni 10000/5000 Ni 10000/6180 Maximum measuring DC current 1 ma 1 ma 1 ma 0,3 ma 0,3 ma Sensor type (K with connector) NS 113x NS 113xK PTS 110x PTS 110xK PTS 210x PTS 210xK PTS 310x PTS 310xK HS 110x HS 110xK Type of sensing element Ni 2226 PT 100/3850 PT 500/3850 PT 1000/3850 thermistor NTC 20 kω Maximum measuring DC current 0,7 ma 3 ma 1,5 ma 1 ma 1 mw *) *) maximum power consumption Sensor type NS 510A NS 710x (K with connector) NS 510AK NS 710xK Note Type of sensing element Pt 1000/3850 Pt 1000/3850 Output 4 to 20 ma 0 to 10 V -30 to 60 C -30 to 60 C Measuring ranges 0 to 35 C 0 to 35 C 0 to 100 C 0 to 100 C Connection head ambient temperature -30 to 80 C 0 to 150 C 0 to 150 C Voltage supply (U NAP) 11 to 30 V DC 15 to 30 V DC Recommended value 24 V DC Maximum ripple U NAP 0,5 % 0,5 % Load resistance Rz 50(U NAP-10) Ω > 50 kω Output signal - sensing element break > 24 ma > 10,5 V Output signal - sensing element short < 3,5 ma ~ 0 V Note: x = version A or version B 10

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a OTHER PARAMETERS: Ni sensing elements: B class, t = ± (0,4 + 0,007t), for t 0; t = ± (0,4 + 0,028 t ), for t 0 in C; Accuracy class Pt sensing elements: B class according to IEC 751, t = ± (0,3 + 0,005 t ) in C NTC 20 kω: ± 1 C for the range 0 to 70 C Measuring error < 0,6 % of the measuring range, minimum 0,5 C Sensor connection according to the wiring diagram Standard length of the stem 25 mm Time response τ0,5 < 9 s (in streaming air at 1m s -1 ) version A τ0,5 30 s (in streaming air at 1m s -1 ) version B Recommended wire cross section sensors with grommet 0,35 to 1,5 mm 2 Type of connector in the head sensors with connector RSFM4 - Lumberg Insulation resistance > 200 MΩ at 500 V DC, 25 ± 3 C; humidity < 85 % Ingress protection IP 65 according to EN 60 529 Material of the sensor stem stainless steel EN X5CrNi18-10 (DIN 1.4301) version Material of the connection head POLYAMID ambient temperature: -30 to 100 C; -30 to 80 C with a converter Operating conditions relative humidity: max. 85 % ((at the ambient temperature 25 C) atmospheric pressure: 87 to 107 kpa Mass approximately 0,15 kg WIRING DIAGRAM TEMPERATURE SENSOR WITH BUSHING: With a resistance output With a converter TEMPERATURE SENSOR WITH CONNECTOR: With a resistance output With a converter connector NS 510A NS 710x NS 510AK NS 710xK DIMENSIONAL DRAFT Temperature sensors with connector Temperature sensors with bushing: connector Version BK Version B Version A 11

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a SENSOR INSTALLATION AND SERVICING SENSORS WITH GROMMET: Before connecting the supply lead-in cable, lift off the lid of the plastic connection head by means of a flat screwdriver. The lead-in cable is connected to the terminals according to the wiring diagram through the loosened grommet. The recommended wire cross section is 0.35 to 1.5 mm 2, the outer diameter of the circular cross-section cable can range between 4 and 8 mm. To insure the ingress protection value of IP 65, the grommet has to be tightened and the lid has to be put on after connecting the lead-in cable. SENSORS WITH CONNECTOR: The lead-in cable with connector is connected to the connector RSFM4, which is the part of the sensor head. Optionally the stand-alone connector ELKA4012, or a lead-in cable of the length of 5 m equipped with a straight-type RKT connector, or with a rectangular-type RKWT connector may be delivered. To insure the ingress protection value of IP 65 the connectors and the lid of sensor have to be tightened and checked. In case the lead-in cable is laid in the vicinity of high voltage conductors or those supplying equipment creating disturbing electromagnetic field (e.g. inductive load equipment), a shielded cable should be used. The openings for the plastic clip installation have to be drilled according to the dimensioned sketch on which the opening diameters and the distances of their centres are illustrated. After installing and connecting the sensor to the sequential evaluating electrical equipment the sensor is ready to use. The sensor does not require any special servicing or maintenance. The device can be operated in any working position, but the grommet must not be directed upwards. Sensors are mounted by means of two methods: a)directly on flat surface by means of two screws Ø 4,5 mm in the openings placed in head corners. The dimmension 13 mm (distance to the barrier in the connection head) must be added to thenecessary length for fastening to a basis; b) by means of the side holder which should be fastened for example on a wall by means of two screws Ø 4,5 mm. To insure the tightness it is necessary to tighten the grommet carefully. During closing of the head by means of the lid the clips should be snapped in origin position. CUSTOMER SPECIFIC MODIFICATIONS REGARDING TO SENSORS MANUFACTURED IN A STANDARD VERSION THE FOLLOWING PARAMETERS CAN BE MODIFIED: possibility to encapsulate two sensing elements possibility to use a 3-wire or a 4-wire connection A class of accuracy (except for the sensing elements possibility to encapsulate other resistance-type elements for Ni 10000/5000, Ni 10000/6180, Ni 2226, thermistor NTC 20 kω) temperature measurements: KTY, SMT 160-30 etc. HOW TO ORDER Temperature sensors for outdoor usage 1 A 1 C C D D 0 0 0 0 0 0 E plastic connection head 0 plastic connection head with connector 3 output 4 20 ma 0 A output 0 10 V 0 V Ni 1000/5000 (N1), class B 0 1 Ni 1000/5000 (N1), class A 0 2 Ni 1000/6180 (N1A), class B 0 3 Ni 1000/6180 (N1A), class A 0 4 Pt 100/3850, class B 0 6 Pt 100/3850, class A 0 7 Pt 500/3850, class B 0 9 Pt 500/3850, class A 1 0 Pt 1000/3850, class B 1 1 Pt 1000/3850, class A 1 2 Ni 891 1 4 NTC 20 kω 1 5 Ni 2226 1 6 Ni 10000/5000 (N10), class B 1 7 Ni 10000/6180 (N10A), class B 1 8 with resistive output 0 0-30 to 60 C 0 1 0 to 35 C 0 2 0 to 100 C 0 3 0 to 150 C 0 4 version A version B WHEN ORDERING GOODS, THE FOLLOWING DATA ARE REQUIRED: Required data Example Required data Example Product type NS 111A Product type NS 510AK Resistance type/4 to 20 ma/0 to 10 V Resistance-type out. (Ni 1000/6180) Temperature range -30 to 60 C Temperature range Lead-in connector NO The accuracy class is the B class if not stated otherwise. A B DELIVERY The sensors are packed in the box by 1 piece. Each delivery contains, if not agreed with the customer otherwise: a plastic side holder. In addition, the following may be provided together with the product: the link connector ELKA4012, the lead-in cable provided by the 12 08.12a 05/10 replaced 08.11a straight-type RKT connector, the lead-in cable provided by the rectangular-type RKWT connector, a calibration sheet, the EU Declaration of Conformity (for the NS 510A, NS 510AK, NS 710x and NS 710xK).

TEMPERATURE SENSORS FOR OUTDOORS PROVIDED BY A METAL CONNECTION HEAD 99.4a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurement of gaseous substances. They consist of a metal measuring stem and a metal connection head, inside which a terminal board is encased. The measuring stem is made of the stainless steel EN X5CrNi18-10 (DIN 1.4301), the connection head of aluminum alloy. The metal connection head is provided with a cable outlet ending. The sensors meet the IP 54 ingress protection requirements according to the EN 60 529 standard. They are suitable for temperature measurement in industrial areas or outdoors. The K 110 metal side holder can be delivered together with the device as accessory. The sensors can be utilised in any control system compatible with sensing elements or active outputs listed in the table of specifi cations. The standard operating temperature range is -30 to 100 C. The sensors are meant to be utilised in chemically non-aggressive environment. SPECIFICATIONS BASIC DATA Sensor type NK 110 NK 111 NK 112 NK 310 NK 311 Type of sensing element Ni 1000/5000 Ni 1000/6180 Ni 891 Ni 10000/5000 Ni 10000/6180 Maximum measuring DC current 1 ma 1 ma 1 ma 0,3 ma 0,3 ma Sensor type NK 113 PTK 110 PTK 210 PTK 310 HK 110 Type of sensing element Ni 2226 PT 100/3850 PT 500/3850 PT 1000/3850 thermistor NTC 20 kω Maximum measuring DC current 0,7 ma 3 ma 1,5 ma 1 ma 1 mw *) *) maximum power consumption Sensor type NK 510 Note Type of sensing element Pt 1000/3850 Output signal 4 to 20 ma -30 to 60 C Measuring ranges 0 to 35 C 0 to 100 C 0 to 150 C Connection head ambient temperature -30 to 80 C Measuring error < 0,6 % of the range 0,5 C at least Power supply (U NAP) 10 to 30 V DC Recommended value 24 V DC Maximum voltage ripple U NAP 0,5 % Load resistance 50(U NAP-9) Ω Output signal - sensing element break > 24 ma Output signal - sensing element short < 3,5 ma 13

TEMPERATURE SENSORS FOR OUTDOORS PROVIDED BY A METAL CONNECTION HEAD 99.4a OTHER PARAMETERS: Ni sensing elements: B class, t = ± (0,4 + 0,007t), for t 0; t = ± (0,4 + 0,028 t ), for t 0 in C; Accuracy class Pt sensing elements: B class according to IEC 751, t = ± (0,3 + 0,005 t ) in C NTC 20 kω: ± 1 C for the range 0 to 70 C Sensing element connection according to the wiring diagram Standard stem length 25 mm Time response τ0,5 < 9 s (in air streaming at 1m s -1 ) Recommended wire cross section 0,35 to 1,5 mm 2 Insulation resistance > 200 MΩ at 500 V DC, 25 ±3 C; humidity < 85 % Ingress protection IP 54 according to 60 529 Material of the stem stainless steel EN X5CrNi18-10 (DIN 1.4301) Type of connection head LIMATHERM MA Material of the connection head aluminium alloy ambient temperature: -30 to 100 C; -30 to 80 C with a converter Operating conditions relative humidity: max. 85 % (at the ambient temperature 25 C) atmospheric pressure: 87 to 107 kpa Mass approximately 0,2 kg WIRING DIAGRAM With a resistance-type output With a converter 4 to 20 ma DIMENSIONAL DRAFT Holder K 110 14

TEMPERATURE SENSORS FOR OUTDOORS PROVIDED BY A METAL CONNECTION HEAD 99.4a SENSOR INSTALLATION AND SERVICING Prior to connecting the lead-in cable unscrew the lid of the metal connection head. The lead-in cable is then connected to the corresponding terminals through the loosend grommet according to the wiring diagram. Recommended wire cross-section is 0,35 to 1,5 mm 2, the outer diameter of the circular cross-section cable can range between 4 and 8 mm. In case the lead-in cable is laid in the vicinity of high voltage conductors or those supplying equipment creating disturbing electromagnetic field (e.g. inductive load equipment), a shielded cable should be used. To insure the ingress protection value of IP 54 the grommet has to be tightened and the lid has to be screwed on after connecting the lead-in cable. The openings for installation of stainless steel holder are drilled according to the dimensional draft, where hole diameters and distances between hole centers can be found. After installing and connecting the sensor to the appropriate electrical equipment, the sensor is ready to use. The sensor does not require any special servicing or maintenance. The sensors can be placed in any operating position but the grommet must not be directed upwards. CUSTOMER SPECIFIC MODIFICATIONS REGARDING TO SENSORS MANUFACTURED IN A STANDARD VERSION THE FOLLOWING PARAMETERS CAN BE MODIFIED: 3- or 4-wire connection available Accuracy class A (except for Ni 10000/5000, Ni 10000/6180, Ni 2226 and thermistor NTC 20 kω sensing elements) Encasing of other resistance-type units for temperature measurement KTY, SMT 160-30 etc. HOW TO ORDER Temp. sensors featuring a stem and a metal conn. head 1 2 1 C C D D 0 0 0 0 0 0 output 4-20 ma 0 A Ni 1000/5000 (N1), class B 0 1 Ni 1000/5000 (N1), class A 0 2 Ni 1000/6180 (N1A), class B 0 3 Ni 1000/6180 (N1A), class A 0 4 Pt 100/3850, class B 0 6 Pt 100/3850, class A 0 7 Pt 500/3850, class B 0 9 Pt 500/3850, class A 1 0 Pt 1000/3850, class B 1 1 Pt 1000/3850, class A 1 2 Ni 891 1 4 NTC 20 kω 1 5 Ni 2226 1 6 Ni 10000/5000 (N10), class B 1 7 Ni 10000/6180 (N10A), class B 1 8 with resistive output 0 0-30 to 60 C 0 1 0 to 35 C 0 2 0 to 100 C 0 3 0 to 150 C 0 4 WHEN ORDERING GOODS, THE FOLLOWING DATA ARE REQUIRED: Data required Example Product type NK 110 Resistance-type / 4 to 20 ma resistance output (Ni 1000/5000) Temperature range Accessory - side metal holder NO The accuracy class is the B class if not stated otherwise. DELIVERY The sensors are packed in the box by 1 piece. In addition, the following may be provided together with the product: the EU Declaration of Conformity (for the NK 510 sensors) the side metal holder, stainless steel, K 110 a calibration sheet. 99.4a 05/10 replaced 99.3a 15