High-Intensity cd Aviation Light

Similar documents
Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant

ICARO Aircraft Warning Lights

Vigilant LED Based Obstruction Lights

Vigilant LED Based Obstruction Lights

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

LM40 Medium Intensity Aviation Obstruction Light

ICARO. Aircraft Warning Lights GENERAL CATALOGUE.

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Vigilant LED Based Obstruction Lights

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

Obstruction Lighting

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

DR. E. HORN GmbH / Schoenaich, Germany

AWL AIRCRAFT WARNING LIGHT MIOL-AC & MIOL-C TYPE OPERATION AND MAINTENANCE MANUAL

RS Pro Infrared Temperature Sensor

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

Dialight Obstruction LED Solutions

SPACE DETECTOR SP Presentation

Products description and application

Reflective Optical Beam Smoke Detector User Guide

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

5 Inch Speed Dome Installation Manual V2.0.0

DUAL OPTIC. Installation manual

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Navigation Lights Signalling Lights Searchlights Whistles TECHNICAL DOCUMENT. DHR 230RCN 230 Remote Controlled Searchlight. Den Haan Rotterdam

RE-PR3-E-27 3-Phase Panel Mount 27kW

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

FAA Obstruction Lighting Buyer s Guide

PRODUCT CATALOG HUGHEYANDPHILLIPS.COM

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

AV-OL-IMAB ICAO Medium Intensity Dual Type A & B Obstruction Light Universal DC & Universal AC Models Installation & Service Manual

M2500 Engine Controller Installation Manual

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

ICAO Medium Intensity Type B or C Obstruction Light Universal DC & Universal AC Models Installation & Service Manual

Laser Distance Sensor Type M Analog-Output

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

WARNING FIRE DOOR CLOSING

Class 1 laser beam sensor safe for your eyes

Turbimax CUE21 / CUE22

Conductive Leakage detectors of the Leckstar range

Operating instructions

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

XLFE-4/1. Borosilicate glass globe

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Danfoss gas detection units

Remote alarm indicator and test combination MK2430

ME 3011C / Alarm Indication / Quick Reference Guide

Model 3300 Technical Support and Installation Manual

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Sensepoint XCL Fixed Gas Detector

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

Temperature Sensor TRG Original Installation Instructions English

Turbimax CUE21 / CUE22

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

INSTRUCTION MANUAL A131 High Level Audible Warning System

7000 RANGE 7300S SMART CONTROLLER THREE-PHASE SOLID STATE CONTACTOR. User Manual

6 Inch Speed Dome Installation Manual V2.0.0

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

KFP-AF Series Fire Alarm Control Panel Installation Manual

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Retroreflective sensor with polarization filter

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

SINGLE MONITORED INPUT UNIT BN-303

Vanguard Red FTS 371 SMART. Medium Intensity RED LED Obstruction Lighting System Reference Manual. Part Number F SERIAL NUMBER

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

COMPUTHERM Q3 digital room thermostat

FAA RECOMMENDATIONS Marking & Visual Identification of Obstacles

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Retroreflective sensor with polarization filter

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

SUPERINTEND VRE-08/16/32/64

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Vanguard Red FTS 371 SMART Medium Intensity RED LED Obstruction Lighting System Reference Manual SERIAL NUMBER. Part Number F

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

MANUFACTURED IN THE UK

AQUARIUS 45 MARINE SERVICE MANUAL

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

OPTISENS TUR 2000 Technical Datasheet

English. Series. Installation and Use Manual

F Technical Bulletin SC 370 SMART Modbus Interface

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Training Guide For FG3000 Dual Medium Intensity Lighting System

Transcription:

High-Intensity 100 000cd Page 1 5 November 30, 2016 Optical Characteristics 100 000cd Flashing @ Day 20 000cd Flashing @ Twilight 2 000cd Flashing @ Night Infrared 850nm Colour aviation WHITE Horizontal radiation pattern 360 Vertical beam 3 High-Intensity 100 000cd Aviation Obstruction Light LED Aviation Obstruction Lights Obelux high-intensity light is designed for marking tall structures such as wind turbines, chimneys, masts, and towers. The product offers unique features such as fault monitoring, photocell and switcher incorporated in the light. Obelux uses a unique environmental friendly optical solution which minimizes light pollution to the neighbourhood. Specifications met ICAO International Standards and Recommended Practices: Aerodromes Annex 14 Volume 1, 6th Edition, July 2013, Chapter 6: High-intensity Type B. Fulfils the Recommendations Section in Table 6-3. Transport Styrelsen TSFS 2016:95 Luftfartstilsynet FOR-2014-07-15-980 Key Features Based on LED technology 100 000cd WHITE flashing light Photocell and fault monitoring GPS synchronization available NVG compliant infrared 850nm light Both stand-alone and ModBUS operations available More than 20 years of design lifetime Dimmable for 100% / 30% / 10% Hot start for radar controlled systems 5-year warranty

High-Intensity 100 000cd Page 2 5 November 30, 2016 Electrical Characteristics Operating voltages 230VAC Constant power input by active PFC Flash rates: 40 fpm Meets standards EMC (Emissions): EN 61000-6-4 EMC (Immunity): EN 61000-6-2 Power consumption (40 fpm) o 200W @ Day o 50W @ Twilight o 20W @ Night Recommended cables: o Power: 3x2,5mm² (Outdoor) L-N-PE o Data: CAT 7 (Outdoor) o Alarm: CAT 7 (Outdoor) Mechanical Characteristics Anodised marine grade aluminium body Glass cover Degree of protection IP65 Operating temperature range -40...+55 C Mounting 240x240mm, ϕ17 Height 428 mm, diameter 364 mm Weight 27 kg Order code Output ICAO GPS sync Op. volt. Infrared Heating (CCV) Photocell and Fault monitoring Packing dimensions H100IR230I 100 000cd Type B No 230VAC Yes No Yes 600x400x400, 32kg H100IR230GI 100 000cd Type B Yes 230VAC Yes No Yes 600x400x400, 32kg H100IRCCV230I 100 000cd Type B No 230VAC Yes Yes Yes 600x400x400, 32kg H100IRCCV230GI 100 000cd Type B Yes 230VAC Yes Yes Yes 600x400x400, 32kg H100IRCCV230GA 100 000cd Type B Yes 230VAC Yes Yes Yes 600x400x400, 32kg I= ModBUS operation with Obelux Control Panel, Local controller, or similar A= Stand-alone operation (see User Manual for configuration)

High-Intensity 100 000cd Page 3 5 November 30, 2016 Installation specifications EMC cable glands M16 and M25 Power input wire diameter 0,5 4mm 2 RS485 data / ALARM input wire diameter 0,2 1,5mm 2 Installation instructions Mount the device to the selected mounting point using quality made fasteners. Level the light using spirit level (bubble level) if the mounting point is not already levelled. Tighten bolts & nuts. Obelux recommends 100 Nm tightening torque for M12 hot-dipped 8.8 bolts with suitable washer between bolt and mounting plate. When the cover door is open, check that there is no inflow of water (incl. hail and snow) into the cabinet. Route power and data cables using cable gland(s). Connect the cable wires securely to appropriate terminal block connectors. Place the hatch plate (door) properly in its place and securely tighten all screws. Make sure that all unused glands or gland holes are sealed. Follow the illustration below to achieve desired EMC protection. 1. Lug (for lifting the light) 2. GPS antenna 3. Location of photocell 4. Service access hatch 5. Cable glands Please follow these instructions when routing cable via a cable gland: 1. Partially expose the braided screen by removing the outer sheath of the cable at a length of approx. 10 mm. 2. Insert the cable through the dome nut and the gland body until the contact spring is pressed against the braided screen.

High-Intensity 100 000cd Page 4 5 November 30, 2016 1 Power input L Live terminal Connect the mains power supply in into these screw connectors. N Neutral terminal Colours are typically brown (for Live) and blue (for Neutral) PE Protective earth Connect protective earth into this screw connector. PE line is typically indicated with yellow/green shield on the wire. Tighten the connector screws using flat-head (straight) screwdriver. 2 RS485 input D+ Data + RS485 non-inverting pin D- Data - RS485 inverting pin SH Shield Shield The RS-485 network (bus) input. 3 Alarm Relay Output NO Normally Open In alarm, connected with COM COM Common Common relay contact NC Normally Connected During normal operations, connected with COM Unused alarm relay connectors can be left floating i.e. no wiring there is required.

High-Intensity 100 000cd Page 5 5 November 30, 2016 4 Configuration DIP switches Configuration DIP switches are used to configure settings (A=Stand-alone operation) and bus addresses (I=ModBUS operation). For Stand-alone (A) operation please check separate User Manual for setting configuration. Configuring Obelux HI Series for ModBUS operation DIP switches are numbered 1-10, the lowest number (1) being on the leftmost edge of the red/white DIP switch block looked from service access door. Turn on DIP 8 to configure the light in to Modbus operation. DIP 10 turns on the termination resistor (120Ω) of the light. Termination should be turned on only at the last light head on the bus. Configuration DIP switches 1-4 are used to give the light RS485 bus address. Duplicate addresses on the same bus are not allowed. DIP DIP DIP DIP 1 2 3 4 Modbus Address on off off off Address 01 off on off off Address 02 on on off off Address 03 off off on off Address 04 on off on off Address 05 off on on off Address 06 on on on off Address 07 off off off on Address 08 on off off on Address 09 off on off on Address 10 on on off on Address 11 off off on on Address 12 on off on on Address 13 off on on on Address 14 on on on on Address 15 off off off off Address 01