EL-USB-1-LCD Temperature Data Logger with LCD

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

EL-OEM-3 OEM Packaged Voltage Data Logger

Specifications Minimum Typical Maximum Unit

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD


EL-USB-TC Thermocouple Data Logger with USB Interface

ELMTEC. Kattreppeln Königslutter / /

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EasyLog Data Logger Series

EasyLog Data Logger Series

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Temperature & Humidity Monitoring For Museums & Heritage Product Guide.

EL-OEM-3 OEM Packaged Voltage Data Logger

Data Logging Solutions

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

DataSheet. Thermocouple Logger

DataSheet. Thermocouple Logger

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

USER MANUAL USB Multi-Function Datalogger Model RHT35

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

User Manual. Humidity-Temperature Chart Recorder. Model RH520

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

HOBO U14 Data Logger User Manual

Microtherm Heat Stress WBGT

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

portable gas analyser

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Follett Performance Plus

PROTÉGÉ ZM SINGLE GAS MONITOR

EASYLOG Temperature Label Series

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

Sirius Technologies, Inc.

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Tinytag Ultra Data Logger Manual

portable gas analyser

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

iminiplus PDF User Guide Version 2.0

Monitoring Solutions

User Manual. Dryer Controller M720

Precision Temperature Humidity Meter DTH184DL User s Manual

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

Temperature/Humidity Monitor. User s Manual

D3 Wireless temperature alarm & monitoring system family. tek-troniks

data logger DL200H DL200D DL200L

LogTag TICT - is0 Tag

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Visit us at testo 835 Infrared and contact thermometer

Precision Temperature Humidity Meter DTH184DL User s Manual

ALTAIR 5X Multigas Detector Product Specification

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

USER MANUAL Digital CO Monitor Model CO30

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Sintrol Snifter A2 EX. Manual. Version 1.2.3

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

USER GUIDE Heat Index Psychrometer

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating Instructions and Maintenance Manual

Affordable wireless monitoring without compromise

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Pocket CO2 Monitor & Data Logger SAN-0001

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

IntelliPack : 800 Series

Data-logger and alarm

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

WS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

THX-DL Data Logger USER & INSTALLATION MANUAL V

Water Tank Level Monitor

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

Batt-Safe Battery String Monitoring System

Instructions for use

Operation Manual Professional Remote Weather Station

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

HART XL High Sensitivity Smoke Detection

Gas Controller Module GC-06

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software

User Manual System 11

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Affordable wireless monitoring without compromise

PRODUCT SPECIFICATION

Transcription:

Temperature Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-1-LCD BAT 3V6 1/2AA FEATURES measurement range USB interface for set-up and data download User-programmable alarm thresholds Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium battery and Windows control software This standalone data logger measures and stores up to 16,378 temperature readings over a range. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows 2000, XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year. The data logger is protected against moisture to IP67 standard when the protective cap is fitted. Specifications Minimum Typical Maximum Unit Measurement range -35 (-31) +80 (+176) C ( F) Internal resolution 0.5 (1) C ( F) Accuracy (overall error) ±0.5 (±1) ±1.5 (±3) C ( F) Logging rate every 10s every 12hr - Operating temperature range -35 (-31) +80 (+176) C ( F) 1/2AA 3.6V Lithium Battery life 1* Year * At 25 C and 1 minute logging rate EL-WIN-USB (CONTROL SOFTWARE) Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista & 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full) The latest version of the control software may be downloaded free of charge from Specifications liable to change without prior warning Issue 2 02/2011 S.L Applies to EL-USB-1-LCD Page 1 of 5

DISPLAY AND STATUS FUNCTIONS The EL-USB-1-LCD features a high contrast LCD and two LEDs. The LCD shows logged temperature values and can also show information regarding the logging status. Maximum logged value symbol Negative symbol Minimum logged value symbol Reading Temperature scale The LCD shows three different recorded readings, which can be cycled through using the built-in push button. The most recent logged temperature, maximum logged temperature and minimum logged temperature can be displayed. In addition, logging and alarm status is shown using two high intensity LEDs. LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a specific data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds Stopped If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. Specifications liable to change without prior warning Issue 2 02/2011 S.L Applies to EL-USB-1-LCD Page 2 of 5

LED FLASHING MODES EL-USB-1-LCD features two LEDs that indicate the logging, battery and alarm status: The first LED flashes red (R) to indicate that the EL-USB-1-LCD is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. The second LED flashes green (G) to indicate that the EL-USB-1-LCD is not in an alarm condition. Hold is enabled by default, which forces the logger to continue flashing the red LED after an alarm, even when the temperature has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. Hold can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. Additional LED modes are explained below: Green single flash (10 seconds) The data logger is currently logging. No alarm. Green single flash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before Green single flash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double flash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single flash (10 seconds) The data logger is currently logging. Low alarm. Red single flash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before Green LED Red LED Red double flash (10 seconds) The data logger is currently logging. High alarm. Red double flash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before Red/Green single flash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Specifications liable to change without prior warning Issue 2 02/2011 S.L Applies to EL-USB-1-LCD Page 3 of 5

DIMENSIONS All dimensions in mm (inches) 25.3 (1.04) 119.5 (4.7) 22.1 (0.87) MEASUREMENT ACCURACY ± 2.0 Accuracy ( C) ± 1.5 ± 1.0 ± 0.5 ± 0.0-40 -20 0 20 40 60 80 Temperature ( C) BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-1-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-1-LCD from the PC. Note: Leaving the EL-USB-1-LCD plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Specifications liable to change without prior warning Issue 2 02/2011 S.L Applies to EL-USB-1-LCD Page 4 of 5

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of multiple data loggers as detailed in the following table: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2+ EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to +60 C (-4 to +140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD+ humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe -200 to +1190ºC (-328 to +2174ºF) (J-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months included -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) ±1ºC (±2ºF) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) *Depending on logging rate, ambient temperature, and use of alarm LED ±1.5ºC (±3ºF) ±4.5%RH 7 days N/A N/A Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T +44 (1794) 884567 F +44 (1794) 884616 E sales@lascar.co.uk 4258 West 12th Street Erie PA 16505 USA T +1 (814) 835 0621 F +1 (814) 838 8141 E us-sales@lascarelectronics.com 8th Floor, China Aerospace Centre 143 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T +852 2797 3219 F +852 2343 6187 E saleshk@lascar.com.hk Specifications liable to change without prior warning Issue 2 02/2011 S.L Applies to EL-USB-1-LCD Page 5 of 5