Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Similar documents
Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Intruder - Fire - Water Combined Alarm

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Application, Installation, Operation & Maintenance Manual

OPERATION AND INSTALLATION MANUAL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Intelligent Security & Fire Ltd

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Intelligent Security & Fire Ltd

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

USER MANUAL CEF AP28 CONTROL PANEL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Surveyor Envoy-MINI 4

Excel-EN Conventional Fire Control Panel

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

DYGIZONE GJD910 Lighting Controller & Enunciator

Door Release Power Supply

SECURIT 700L PLUS ENGINEERING MANUAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Installation Manual Premier 412/816/832. Issue 10

End To End Optical Beam Smoke Detector. Additional Information

GAS SUPRESSION CONTROL PANEL:

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SOLO Single Loop Addressable Fire Control Panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

TABLE OF CONTENTS TABLE OF CONTENTS 1

Control Panel Engineering and Commissioning Instructions

5000 SERIES 8 ZONE INSTRUCTION MANUAL

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Control Panel User Guide

AXS Strikemaster Engineering Manual

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

FEC400 Series. Installation Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Conventional Fire Alarm System 2014 V1.2

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

User Operation Manual

USER MANUAL & MAINTENANCE GUIDE OG OO

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

SECURIT 703 USER MANUAL

Security System. User Guide for the LED Command Center

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

NX-148 LCD CODE PAD TABLE OF CONTENTS

EXTINGUISHING AGENT RELEASE MODULE

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

FIRE ALARM CONTROL PANEL FVC01-08

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

ZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

System 800 Addressable Fire Detection & Alarm System

4 wire conventional alarm system

Control Panel User Guide

Model 17A00 Expansion Enclosure

USER GUIDE. Security Control Panels INS046-7

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

FEC403EN Installation Manual

SYSTEM 5000 USER MANUAL

Fire detection and alarm system Operating instructions

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

Document No Issue 4 user manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

Advantage 6 Alarm Panel

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

user manual Document No , Revision 03 November 2015

GARDTEC 580. Installation Instructions

Security System. User s Guide for the Text Command Center

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Transcription:

Fire Control Panel Installation & Programming Manual TBLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Inputs 4 Outputs 4 LED Indications 4 User Keypad Functions 5 Engineer Keypad Functions 6 Engineer Programming 6 Troubleshooting 7 Specification 9 Connection Diagram 10 Keypad Function Chart 11 Noby-420 Installation & Programming Instructions Rev3 Page 1 of 12

GETTING STRTED We strongly recommend that the Noby-420 is first powered up with all 4K7 End Of Line resistors fitted at the panel as supplied by the factory. In this way you can gain confidence that the panel is operating correctly before introducing detector and sounder circuits. Power-Up With Battery Connect two 12v SL batteries in series (+ ve to ve) to form a 24 volt battery stack, using the battery jumper link supplied. Connect the black battery lead to the battery stack ve terminal. Connect the red battery lead to the battery stack + ve terminal. It is normal to see a small spark. The Common Fault LED will be continuously lit together with flashing PSU and CPU fault LEDs. These faults are also accompanied by an audible fault tone signified by 4 rapid pips every 4 seconds. Press [3][6][3][6] [1][4][5] to silence and perform a System Reset observe a 3 second LED test. The panel should then settle to quiescent state with all LEDs off. Connect the mains power supply to the fused screw terminal block The panel should now be in a standby state with only the green Power LED continuosly lit. Power-Up With Mains Connect the mains power supply to the fused screw terminal block. The green Power LED will be continuously lit. The Common Fault LED will be continuously lit together with flashing PSU and CPU fault LEDs. These faults are also accompanied by an audible fault tone signified by 4 rapid pips every 4 seconds. Connect two 12v SL batteries in series (+ ve to ve) to form a 24 volt battery stack, using the battery jumper link supplied. Connect the black battery lead to the battery stack ve terminal. Connect the red battery lead to the battery stack + ve terminal. It is normal to see a small spark. Press [3][6][3][6] [1][4][5] to silence and perform a System Reset observe 3 second LED test. The panel should now be in a standby state with only the green Power LED continuously lit. Notes 1. The panel will persist in reporting a PSU fault after a System Reset if the battery is either not present or the battery fuse F4 has blown. 2. Whilst there is a measure of protection against accidental reverse connection of the battery, such action will blow fuse F4 and may cause permanent damage to the panel. Noby-420 Installation & Programming Instructions Rev3 Page 2 of 12

Power Supply Unit The Noby-420 has a 27volt regulated PSU, with a continuous current rating of 1.0, and a 20 minute rating of 1.5. The PSU is designed to meet the internal standby power requirements of the Noby-420 and also to charge and maintain the SL standby battery in optimum condition. The battery standby time is dependant upon the overall system current drawn, including any ancillary equipment connected to the ux 24v. lso it is strongly recommended that the continuous system standby current does not exceed 1.0, because some reserve PSU current may at times be required to rapidly re-charge the battery (e.g. after an alarm condition or prolonged period of mains loss). The Noby-420 enclosure can accommodate two 12v/7hr SLs connected in series. Care must be taken when planning an installation that there is sufficient battery capacity to meet the relevant standards regarding battery standby times. lways ensure that the maximum current drawn in alarm does not exceed the 3.0 battery fuse limit (F4). The PSU is monitored for : i) Mains bsence Power LED extinguishes when mains absent for more than 90 seconds and flashes once mains restored. Mains absence is accompanied by an intermittent warning bleep every 16s (mutable). ii) Low Voltage < 21v PSU Fault LED continuously lit whilst voltage < 21v and flashes when the voltage is restored to > 23v iv) Battery Capacity Test PSU Fault LED flashes iii) Fuse F4 (Battery/Low Volts) PSU Fault LED flashes v) Fuse F1 (ux 24v) PSU Fault LED flashes Note 1: PSU faults are accompanied by a fault tone signified by 4 rapid pips every 4 seconds. Note 2: The Battery Capacity Test is performed immediately after a System Reset and thereafter at 12 hour intervals. Noby-420 Installation & Programming Instructions Rev3 Page 3 of 12

Inputs Zone Detector Circuits The Noby-420 requires that each detector zone is terminated with a 4K7 End Of Line resistor. This EOL resistor is necessary to facilitate open circuit, short circuit and head removal monitoring. The total current drawn by the detectors on each circuit must not exceed 2m, which means that 20 detectors can be connected to each zone (based on a typical 100u maximum per detector). Similarly, if the detectors are specified at 50u maximum current draw, then 40 detectors per zone can be connected. Class Change Input (Direct Bell Ring) positive going input signal to activate on the sounders directly (subject to their isolation status). The input is non-latching and no indication is given on the display. Fault Input n input signal permitting the fault status of remotely connected ancillary equipment (eg. a communication device) to be indicated on the Noby-420 display panel, causing the Common Fault LED to flash. The polarity of the Fault Input signal is programmable see Engineer Programming. Outputs Sounder Circuits Conventional 4K7 End Of Line resistor monitoring requiring polarised bells or sounders with a combined output current of 1.25 across the 2 sounder ports. Each sounder circuit is individually fused and monitored. Fire Relay Output Double pole voltage free contacts, each rated at 1@30V, activated upon detection of a zone fire or by the keypad operated Evacuate function. It is latched until a System Reset. The relay can be isolated - see User Keypad Functions / Isolation. The Fire Relay Output is not triggered by the Class Change (Bell Ring) Input or from any activation of a zone that has been programmed as a non-latching zone. The Fire Relay contacts are NOT mains voltage rated, and any mains voltage switching MUST be done with the addition of a mains rated slave relay. Panel Sounder (Piezo) n on-board piezo sounder provides the panel s internal fire and fault warning tones. Fire tone = continuous rapid pips. Fault tone = 4 rapid pips every 4 secs. Warning Tone = 2 pips every 16 secs. ux 24v 27.3v (nominal 24v) auxiliary supply fused at 1 (Fuse F1), monitored. Fault Output Signals real-time status of System Faults from all sources (zone faults, sounder circuit faults, PSU etc.). It is an open collector PNP output normally driven to 24 volts, and dropping to 0 volts during a fault condition. The output has a 470 ohm series limiting resistor. LED Indications LED Indications Continuous Flashing 2 Zone Fire LEDs Zones alarmed First To larm (winking) Common Fire LED One or more zones in fire condition N/ 2 Zone Fault LEDs Zone/s in fault Zone/s isolated (slow flash) Head Removed (intermittent winking ) Common Fault LED ny zone fault or system fault Fault Input terminal active, non-latching Sounder Fault LED Sounder fault Sounders Isolated PSU Fault LED Low voltage (< 21 volts), non-latching Fuses F1 or F4, or Low Volts (latched). CPU Fault LED N/ CPU watchdog warning Power LED On=Mains OK. Off=Mains absent Mains restored Relay Isolate LED N/ Relay isolated Function LED ccess code successfully entered N/ Isolate LED N/ One or more zones isolated Test LED N/ 7 day fire test reminder Noby-420 Installation & Programming Instructions Rev3 Page 4 of 12

USER KEYPD FUNCTIONS General Each of the following functions must be preceded by the ccess Code which is fixed at [3][6][3][6]. Successful entry of the ccess Code is confirmed by the red Function LED. Pressing [5] to Quit at any time will cause the system to revert back to normal standby mode, otherwise the system will automatically revert back after 10 seconds of inactivity. Mute Sounders [3][6][3][6] [1] Main external sounders switched off. Mute Panel [3][6][3][6] [4] Panel internal sounders (piezos) switched off. System Reset [3][6][3][6] [5] ll LEDs are tested for 3 seconds. Quick Reset [3][6][3][6] [1] [4] [5] Quick Reset is an amalgamation of the first three operations above. Note that the Main Sounders & Panel Sounder MUST be individually muted before a reset can be accepted. Reset is acknowledged by a 3 second LED test. Evacuate [3][6][3][6] [2] The main external and panel internal sounders are switched on. The Fire larm Relay is activated. Zone_Isolate & Relay_Isolate [3][6][3][6] [3] This function is used to Isolate zones and/or the Fire larm Relay. The current isolation status is displayed by any flashing yellow zone LED s and/or the Relay_Isolate LED. Note that scrolling down automatically wipes any pre-existing isolation status LEDs. Key [1] to Scroll-Down and highlight the desired yellow zone LED (or the Relay_Isolate LED) for selection. Key [3] to Toggle the selected zone (or the relay) on or off the LED flashes when isolation is active. Key [4] to ccept and update the current isolation status and then revert back to normal standby mode...or Key [5] to Quit and revert back to normal standby mode without updating the displayed isolation status. Once back in normal standby mode any isolated zone (or relay) is confirmed by a flashing zone fault LED (and/or Relay_Isolate LED). Zone_Isolate and/or Relay_Isolate operations should only be performed or authorised by the Installation / Service Company. One Man Test [3][6][3][6] [6] This function is used to one-man test the system. Key [1] to Scroll-Down and highlight the zone for test. Key [6] to Toggle the zone selected for test on or off the yellow zone LED will flash when in test mode. It is now possible to trigger each detector or call-point in turn on the selected zone. The sounders are pulsed for as long as a fire condition is applied (provided they are not isolated) and the Zone Fire LED is latched. The Fire larm Relay is not activated. Key [5] to Quit to revert back to normal standby mode. The system will revert back to normal standby mode after 90 seconds of panel inactivity (i.e. no keypad operations or zone activations). ny fire alarm generated from a non-test zone will cause the system to abort the test and give the appropriate fire response. Noby-420 Installation & Programming Instructions Rev3 Page 5 of 12

ENGINEER KEYPD FUNCTIONS General Pressing [5] to Quit at any time will cause the system to revert back to normal standby mode, otherwise the system will automatically revert back (kickback) after approximately 10 seconds of inactivity. Sounder Fault Identification [6][2][5][3] [1][1] This function is used to identify which sounder circuit is in fault condition. The sounder circuit in fault is indicated by means of the corresponding yellow zone fault LED. Key [5] to Quit and revert back to normal standby mode. Isolate Sounders [6][2][5][3] [3][1] This function is used to isolate the main sounders. The panel piezo sounder is unaffected. Key [3] to Isolate the sounders - a toggle on/off action. Key [4] to ccept and update and then revert back to normal standby mode... OR Key [5] to Quit and revert back to normal standby mode without updating the Sounder Isolate status. The sounder isolation status is confirmed by a flashing Sounder Fault LED. 15 Event Log Recall [6][2][5][3] [6][1] On entering the Log Recall mode all LED s are initially lit. Key [1] to Scroll Down or rather scroll back through the last 15 events. Key [4] to ccept, clear the log memory and then revert back to normal standby mode... OR Key [5] to Quit and revert back to normal standby mode without clearing the log memory. Note: Each time the Noby-420 is reset following a fire or fault condition the LED display is entered into the log. The log holds the 15 most recent LED displays. ENGINEER PROGRMMING - System Options 1 Configure Zone-1 Non-Latching [6][2][5][3] [3][5] [1] This option configures Zone-1 as non-latching. Key [1] to Toggle the option - the Zone-1 fault LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM... OR The factory default is with the option disabled i.e. Zone-1 is latching. Configure Zone-2 Non-Latching [6][2][5][3] [3][5] [2] This option configures Zone-2 as non-latching. Key [2] to Toggle the option - the Zone-2 fault LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM... OR The factory default is with the option disabled i.e. Zone-2 is latching. Note: non-latching zone will momentarily activate the sounders (subject to their isolation status), panel sounder, and also display momentary indication on the appropriate zone fire LED. Configure Latching Zone Faults [6][2][5][3] [3][5] [3] This option configures both zones to latch zone faults. Key [3] to Toggle the option - the Isolate LED indicated the current option status. Key [4] to ccept and update the configuration option to E2PROM... OR The factory default is with the LZF option disabled i.e. zone faults are non-latching. Configure Weekly Test Reminder [6][2][5][3] [3][5] [6] This option configures the Weekly Test Reminder function. Key [6] to Toggle the option - the Test LED indicated the current option status. Key [4] to ccept and update the configuration option to E2PROM... OR The factory default is with the WTR option disabled. Once enabled the WTR will cause the Test LED to flash accompanied by an intermittent warning sound (mutable) after 1 week of no fire activity on the panel. The timer is automatically reset after a fire condition has been generated and subsequently cleared (i.e. a manual test cycle). Noby-420 Installation & Programming Instructions Rev3 Page 6 of 12

Configure Fault_Input Polarity [6][2][5][3] [2][4] [1] This option configures the Fault_Input signal to be normally high, going low to initiate a fault condition. Key [1] to Toggle the option - the Common Fault LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM... OR The factory default is with the option disabled i.e. the Fault_Input is normally low, going high to initiate a fault condition. ENGINEER PROGRMMING - System Options 2 The following options allow various monitoring functions to be disabled, and are intended to make the Noby-420 backwards compatible with detectors and sounders that may be encountered in older installation sites. With each of the following options the corresponding status LED indicates that the monitoring is disabled when the status LED is ON. Detector Head Removal Monitor Inhibit [3] [3] [5] [1] [4] [2] [6] [3] [1] This option disables the head removal monitoring. Key [1] to Toggle the option - the Zone-1 fault LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM - then revert back to normal standby mode..or Zone Short Circuit Fault Monitor Inhibit [3] [3] [5] [1] [4] [2] [6] [3] [2] This option disables zone short-circuit monitoring and forces s/c s to be detected as a fire condition. Key [2] to Toggle the option - the Zone-2 fault LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM - then revert back to normal standby mode..or Battery Condition Monitor Inhibit [3] [3] [5] [1] [4] [2] [6] [3] [3] This option disables the battery capacity and battery fuse monitoring. Key [3] to Toggle the option - the Isolate LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM - then revert back to normal standby mode..or Sounder Circuit Fault Monitor Inhibit [3] [3] [5] [1] [4] [2] [6] [3] [6] This option disables the sounder circuit fault monitoring. Key [6] to Toggle the option - the Test LED indicates the current option status. Key [4] to ccept and update the configuration option to E2PROM - then revert back to normal standby mode..or TROUBLESHOOTING Power Supply The Power LED not illuminated Check that the mains supply is connected and switched on. Check the mains supply fuse in the terminal block adjacent to the transformer. Check the transformer secondary fuse F5 on the main board. PSU Fault LED continuously illuminated The panel is detecting low voltage (< 21V) from the batteries. Check the batteries are connected correctly, in series, and observing strict polarity. The batteries may be heavily discharged allow approx. 1hr for a partial re-charge. The PSU Fault LED will flash when the battery voltage increases to 23V. The PSU Fault will clear when the panel is reset. The batteries may be faulty replace as necessary. PSU Fault LED flashing Check the batteries are connected correctly, in series, and observing strict polarity. Check Fuse F4 (Battery). Check Fuse F1 (ux 24V). Noby-420 Installation & Programming Instructions Rev3 Page 7 of 12

Zone Faults Zone Fault LED continuously illuminated Disconnect the relevant zone and replace with the EOL resistor (4K7) at the zone terminal. If the fault can now be cleared then there is a possible wiring error in the zone. Check that the correct value EOL resistor is fitted at the end of the zone. Check that the wiring and connections at each detector are consistent, and not crossed-over at any point along the cable run. Check that all manual call-points in the zone are intact and fitted with an appropriate series resistor, typically 470 ohms. If a Zone Fault LED becomes continuously illuminated when a head is removed, then that detector base may be the wrong type. Check that a schottky diode is fitted and correctly connected. Replace the suspect detector base if necessary. Zone Fault LEDs Flashing One or more zones are isolated. Zone Fault LED intermittently winking detector head is either missing or incorrectly connected. Check all detector heads on the corresponding zone are fully seated in their bases. Some (older) detectors may be incompatible with head-removal monitoring in which case it is recommended to set the Head Removal Monitor Inhibit (System Options 2). Fire is detected as Zone Fault Check all detector heads on the corresponding zone are fully seated in their bases. The panel monitors the zone for a short circuit. Some (older) detectors and call points may be incompatible with short circuit monitoring in which case it is recommended to set the Zone S/C Inhibit (System Options 2). Sounder Faults Sounder Fault LED continuously illuminated Enter the code [6][2][5][3][1][1] to bring up the sounder fault display, shown by the zone fault LEDs. Check the corresponding sounder fuses F2 and/or F3. Disconnect the suspect sounder circuit and fit a 4K7 EOL resistor at the sounder terminal. If the sounder fault clears then there is a possible wiring fault in the circuit. Check all connections between sounders. Check that the correct value 4K7 EOL resistor is fitted in the circuit. Some types of sounders may be incompatible with the Noby-420 sounder circuit monitoring function in which case it is recommended to set the Sounder Circuit Fault Monitor Inhibit (System Options 2). CPU Fault Indication CPU Fault LED Flashing It is normal to see a CPU Fault at power-up, and can be cleared by performing a panel reset. Persistent CPU faults may indicate interference from electrical machinery or RF transmitters in the immediate locality. Common Fault Indication Common Fault LED Flashing persistently Check that the Fault Input polarity is correctly programmed (Engineer Programming Sysop1), and that the Fault_Input terminal, if used, is in the required state to hold-off the Common Fault LED. Note that the Fault_Input Polarity option should be disabled (factory default) if the Fault Input terminal is unused or not connected to remote equipment. larm Relay larm relay not working Check that the relay is not isolated. User Keypad Operation Reset command [3][6][3][6] [5] is ignored nothing happens. Both the external sounders and internal panel piezo sounder must first be muted before the reset button is acknowledged. This can be performed in one operation by performing a Quick Reset [3][6][3][6] [1][4][5]. Noby-420 Installation & Programming Instructions Rev3 Page 8 of 12

NOBY-420 SPECIFICTION Power Supply Unit Value Unit Comments Mains Supply Voltage 230 +10% -6% VC Mains Supply Frequency 50 / 60 Hz Mains Power Rating 40 V Nominal Battery Voltage 24 volts Regulated PSU charger voltage 27.3 volts Regulated PSU charger current 20 minute rating continuous Fused Outputs: F1 ux 24v F2 Sounder 1 Circuit F3 Sounder 2 Circuit F4 Battery + ve F5 30VC Transformer Secondary 1.5 1.0 1.0 1.0 1.0 3.0 2.0 F1 F1 F1 T3 T2 20mm Quick Blow 20mm Quick Blow 20mm Quick Blow 20mm Slow Blow 20mm Slow Blow Standby Battery Current: 60 m 2 zone + 2 sndr EOL resistors fitted Low Voltage Monitor 21.0 volts Battery Capacity Monitor Yes 10s load test every 12hrs Zone Circuits Value Unit Comments Detection Zones 2 No. Detectors Per Zone 20 based on 100u per detector End Of Line (EOL) Resistor 4700 ohms Open Circuit Monitoring R > 10,000 ohms Short Circuit Monitoring R < 150 ohms Fire larm Detection 150 < R< 1600 ohms Head Removal Monitoring Yes requires schottky diode bases sampled at 60s intervals Sounder Circuits Value Unit Comments Sounder Circuits 2 Maximum No. Sounders Per Circuit 50 based on 20m per sounder Maximum No. Sounders Total 62 based on 20m per sounder End Of Line (EOL) Resistor 4700 ohms Open Circuit Monitoring > 10,000 ohms Short Circuit Monitoring < 1K ohms Fire larm DPDT Relay 1.0 rated at 1.0/30Vdc per contact set Signal Inputs Value Unit Comments Class Change CC 200 kohm 24volt + ve going signal Fault Input 200 kohm 24volt signal (polarity programmable) Cabinet Value Unit Comments Dimensions (width x height x depth): 335 x 325 x 75 mm 1.2mm powder coated steel Shipping Weight 4.2 kg Noby-420 Installation & Programming Instructions Rev3 Page 9 of 12

Noby-420 Installation & Programming Instructions Rev3 Page 10 of 12

Noby-420 Installation & Programming Instructions Rev3 Page 11 of 12

Noby-420 Installation & Programming Instructions Rev3 Page 12 of 12