ZP3 Operator & Maintenance Manual Version 1

Similar documents
Fire Alarm Control Panel. System Maintenance and Log Book

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Control Panel User Guide

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

FIRE ALARM CONTROL PANEL FVC01-08

USER MANUAL & MAINTENANCE GUIDE OG OO

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

SYSTEM 5000 USER MANUAL

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Control Panel User Guide (TO BE RETAINED BY THE USER)

Fire detection and alarm system Operating instructions

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

LOG BOOK & CERTIFICATES

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Control Panel User Guide

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Document No Issue 4 user manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Intelligent Security & Fire Ltd

ID2000. operating manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Firetrax Professional Conventional Fire Control Panel

user manual Document No , Revision 03 November 2015

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

System 800 Addressable Fire Detection & Alarm System

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Intelligent Security & Fire Ltd

U ser's Guide PC6010

False Alarm Management. Graham Simons FIA Technical Manager

CSP-204 CSP-208 CSP-104 CSP-108

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

USER MANUAL CEF AP28 CONTROL PANEL

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

EP203. User Manual and. Approved Document No. DFU Rev 1

FIRE SAFETY LOG BOOK

User Operation Manual

Intelligent Security & Fire Ltd

ZSC100 Gas Detection and Alarm System Controller

a) Establishment of emergency procedures to be followed at the time of an emergency;

REPEATER FS5200R OPERATION MANUAL

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Fire detection and alarm

SECURIT 703 USER MANUAL

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

SECURIT 700L USER MANUAL

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

INTRUDER ALARM FOR BUSINESS SECURITY

INTRUDER ALARM FOR BUSINESS SECURITY

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours

QA16 Addressable System

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

M800, M800iD Plus, M1000 and M3000. User's Guide

HARDWIRED CONTROL PANELS

QUICK USER GUIDE. Alarm Control Panel

Security System. User s Guide for the Text Command Center

PREMISES FIRE SAFETY LOGBOOK

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Watchguard WGAP864 User Manual

User Operation Guide Document: VI49.2

Fire Safety Register

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Scantronic Leading the way in security

NextGen Home Security. Quick Reference Guide

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

HARDWIRED CONTROL PANELS

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Model: Ei450. Instruction Manual

ZXSe Range Data Sheet

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

FT2010 Floor repeater terminal Operation Manual

Electrical Safety Policy and Management System

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

Transcription:

ZP3 Operator & Maintenance Manual Version 1

Introduction Thank you for selecting Clymac Ltd. Clymac can provide maintenance for the system, emergency call out, telephone support and any modifications required during the life time of the ZP3 system. To ensure the ZP3 system continues to operate without false alarm or fault the system will require regular maintenance from a qualified engineer. If you decide to choose Clymac as the maintenance provider we can offer the following benefits; Reduced call out charges Clymac Engineers carry most spares to enable first time fix Clymac have the largest stock of spares in the UK Immediate out of hours telephone response & engineer on site in 8 hours Discounts for long term agreements We will be happy to provide a quotation for maintenance, please call & ask for maintenance sales

Contents Reference information...1 System in Alarm. 2 Disable a Point...3 Silencing the Fault Buzzer.4 Setting the Clock 5 Other Panel Controls.. 6 Your Responsibility...7 Log Book... 8 Data Sheets & Device Labels........9

Reference Information 1 Address of protected premises: Responsible person: The system was designed by: The system was installed by: The system was commissioned by: The system was accepted by: Verification was undertaken by: Maintenance Company:........ Emergency Telephone Numbers: 01509 232651 (Normal working hours) 07659 134363 (Outside normal hours) Maximum attendance time for a maintenance technician is: Major Fault - 8 Hours Minor Fault - 24 Hours Expendable components replacement list: Panel Batteries 4 years from commissioning date PSU Batteries 4 years from commissioning date HSSD Filter 1 year from commissioning data...

System in Alarm 2 Event Action Panel Notes LCD = Zone No, text and time of event Fire Initiate fire safety strategy Status Display = Red Active sounders, remote alarm & control O/P Objective s = Ensure safety, find the source & silence/ reset the system Fire - Find Source LCD = Point address, type, text, time of event, zone No & text Objective = Locate device & identify cause. MORE buttons denote more fires waiting to be shown see page 7. Also network systems will have panel number detailed. Fire Silence Alarms LCD = Enter control key code **** Objective = Enter level 2 access code typically 2000 Enter Access code KEY PAD 1000 followed by; LCD = **** changes to XXXX as user inputs the access code. Once access is granted the system operates a 2 min timer from last button press before it logs the user out. Mute Buzzer LCD = Zone No & text Status Display = Active sounder extinguished and yellow sounders silenced Objective = ensure the source will not cause the system to retrigger. This can be achieved by disabling the point address Reset LCD = System return to normal Status Display = returns to normal Objective = record incident in the log book

Disable a Point 3 Event Action Panel Notes LCD = Point address, type, text, time of event, zone No & text False Alarm Status Display = Red Active sounders, remote alarm & control O/P Objective = Record the point address e.g. 1001 LCD = Top menu page View Menu Selection Status Display = N/A Objective = Disable the point address before reset Enter Maintenance Menu On the key pad press the number: 2 LCD = Maintenance Menu Objective = Disable the point address before reset Enter edit disable menu On the key pad press the number: 1 LCD = Maintenance Menu Objective = Disable the point address before reset Specify point to be disabled On the key pad enter the point address e.g.: 1 0 0 1 (then) LCD = Maintenance Menu Objective = Disable the point address before reset Specify the point to be disabled On the key pad press the number 1 (then) LCD = System return to normal Status Display = returns to normal Objective = Save data by pressing the following on the key pad & record in log book:

Silencing the Fault Buzzer 4 Event Action Panel Notes LCD = Zone No, text and time of event System Fault Investigate the nature of the fault Status Display = Yellow Faulty Zone & point Objective s = Record Fault in log book & action repair Find source LCD = Point address, type, text, time of event, zone No & text Objective = Locate device & identify any obvious cause e.g. device removed or water leak Silence buzzer LCD = N/A Objective = Ensure the fault is attended to & leave the fault on screen i.e. do not reset or disable fault

Setting the Clock 5 Event Action Panel Notes LCD = Top menu page View Menu Selection Status Display = N/A Objective = Set the time, day and date Enter Operator Menu On the key pad press the number: 1 LCD = Operator Menu Objective = No Change Enter date menu On the key pad press the number: 1 Set the date by entering dd/mm/yyyy and then adjust the day by using the arrow up/down Enter time Set the time by entering hh:mm followed by enter Return to home page Note new time, date & day

Other Panel Controls 6 Event Action Panel Notes More button Illuminate when more information is waiting to be shown. Press either button to view the next event. The events will scroll around with each push of the corresponding more button. Restore disabled alarm Used to enable previously disabled sounders quickly to facilitate an evacuation during routine maintenance. If pressed with access code when the system is in fire the alarms will activate. Other outputs such as lifts/gas/hvac and Fire Brigade will not have activated Viewing different event types i.e. Fire, Fault, Disabled Events are prioritised with any fire event having the highest priority. However, to view any type of event press the corresponding button to view zonal information followed by view points for further information. Controls On/Off switch Turn to the off position When this is in the off position the controls detailed will be isolated to prevent unauthorised operation.

Your Responsibility 7 Ensure a maintenance contract is in place complying with the recommendations of BS 5839 Part 1 Section 6 Ensure the system is tested with a different Manual Call Point (MCP) each week in a way that demonstrates to all staff what the Fire Alarm sounds like. In carrying out this test the basic function of the system is also tested. Maintain a system log book recording; Responsible person & maintenance provider details The weekly test point address, date, time & name False alarms date, time, address/location, category *, reason, action taken and name Details of service/repair Faults date, time, address/location, type of fault, reason, action taken and name Visually check the panel daily Ensure other users of the system are familiar with the system Arrange for suitable investigations when the system false alarms Manage the system & activities in the building it protects by; Ensuring visiting contractors are aware of the automatic detection & that method statements include protecting the automatic detector from any pollutants that may trigger a false alarm. This should include a temporary dust cover and point disablement Notification to staff and alarm receiving centres (RedCare) when the system is due to be tested and/or maintained. Keep all MCP s free from any obstruction & on show Keep 500mm clear space in all directions around automatic detectors Give consideration to the fire alarm system when the building is modified. The objective of the fire alarm can be compromised by adding/removing walls/doors. Also, any change in use may require change of and/or additional detectors to ensure minimal false alarms. Ensure As-Fitted drawings and detailed records at the end of this manual are kept up to date. Ensure suitable quantities of replacement MCP elements/keys are kept on site. * Categories of false alarms are; Unwanted steam, smoke, dust, insects etc and human error Unknown/equipment No obvious reason could be faulty equipment Malicious Good intent

Log Book 8 DATE TIME DETAILS ZONE DEVICE INITIALS

Log Book 8 DATE TIME DETAILS ZONE DEVICE INITIALS

Log Book 8 DATE TIME DETAILS ZONE DEVICE INITIALS

Data Sheets & Device Labels 9 Included at the end of this manual are standard data sheets for the equipment installed and finally a print out detailing the zone & point text labels. This information should be cross referenced with the As-Fits for accuracy.

Cloudway Court Belton Road Loughborough LE11 1LW Tel: 01509 232651 Fax: 01509 232665 E-mail sales@clymac.co.uk