WF2613 Classic Corner Washfountain with 9" Deep Bowl

Similar documents
WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

SN2003, SN2023, SN2004, SN2024

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

SS-3N Express Lavatory System SS-Series

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

Installation Instructions

Installation Instructions

AV30 Advocate Lavatory System AV-Series

Installation Instructions

Installation Instructions

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

FL-2H, FL-2L Frequency Lavatory System FL-Series

AV60 Advocate Lavatory System AV-Series

Installation Instructions

Express Lavatory System MG-Series

Installation Instructions

Express Lavatory System MG-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

AV60 Advocate Lavatory System AV-Series

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

AV90 Advocate Lavatory System AV-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LD-5010 OmniDeck with WashBar 5000 Series

LVSD2 Verge Wash Basin LVS-Series

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

AV60 Advocate Lavatory System AV-Series

Installation Instructions

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVSD2 Verge Wash Basin LVS-Series

Installation Instructions OBSOLETE

Washfountain Application Guide

HL45, HL80 Thermostatic High-Low Valves

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

School Solutions Ideabook

SECTION DOMESTIC WATER PIPING SPECIALTIES

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation IMPORTANT! Bradley Multi-Station Wall Sink

LVQD3 Verge with WashBar Technology LVQ-Series

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

LVQD1 Verge with WashBar Technology LVQ-Series

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

A. Section Joint Sealants: Seal fixtures to walls and floors.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

FL-3H, FL-3L Frequency Lavatory System FL-Series

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

DUKE UNIVERSITY CONSTRUCTION STANDARDS

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Willoughby Industries - Security Products

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Mechanical Inspection Plumbing

All porcelain bowls are available in black & white. Just 22" front to back. Perfect for stylists with a shorter reach!

Effective Date: June 2017 Void After: June Product: Plumbing Fixture Fittings File No. 4995

Willoughby Industries - Security Products

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

2011 Veterinary Stainless Steel Catalog

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Model Z Sundara Reef Triple Basin Hand Washing System

Transcription:

cupc Certified Available in a 54" Bowl Size 9" Deep Bowl, Designed for Heavy Duty Hand Washing Reliable Foot, Air, TouchTime or Infrared Activations Specifications Size and Capacity Accommodates three users at a time, using less water, energy and space than lavs equipped with conventional faucets. The classic sprayhead (non-sectional) is controlled by an infrared sensor, electronic pushbutton or piezo switch, air activated pushbutton or foot rail. The operating water pressure range is 20 80 psi. Flow rates differ based on the model. Flow rate controlled by volume control valve. Construction Bowl Material Precast Terrazzo: Composed of approximately 85% stone and 15% binder with steel reinforcing rods cast into the bowl. Polished and sealed with urethane resin. Pedestals Pedestals consist of die-formed legs, upper braces, scuff bases and panels: legs are 14 gauge galvanized steel; upper braces are heavy gauge steel coated with a rust preventative; pedestal panels and scuff bases are stainless steel with a #4 finish. Standard Equipment Valves and Fittings In addition to bowl and pedestal, the following valves and fittings are standard: sprayhead with stainless steel supporting tube, restraining bracket, and bowl gasket; spud with locknut and beehive strainer; sprayhead supply line; manual mixing valve; volume control valve; combination stop/strainer/check valves. Activation Controls Foot Each press of the foot rail mechanically actuates a hold-open valve, with slow closing upon release of foot pressure. Air Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 12 seconds. Each push button activates a flow of tempered water from the classic nonsectional sprayhead. Push button requires less than five pounds of pressure. Infrared Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from the classic non-sectional sprayhead. Shut-off is automatic seven seconds after hands are removed from the detection area. The infrared sensor module uses a conical-shaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a 12V plug-in adapter as standard equipment: Solenoid 12VDC, 3/4" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage UL/CSA listed 120VAC/12VDC plug-in adapter. Plugs into a standard GFCI protected electrical outlet. Location of plug-in adapter per local electrical code. Page 1 of 5 4/23/2018 WF2613 - With Foot Control TouchTime Each low-voltage mechanical pushbutton or piezo switch actuates a non-hold-open, slowclosing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the classic non-sectional sprayhead. TouchTime controls water flow at all stations through the use of solid state, digital circuitry. Timing is factory set at 12 second run time but is field adjustable to pre-set timeout periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Push button and piezo switch requires less than five pounds of pressure. Code Compliance and Certifications cupc Certified WF2613 - With TouchTime The Terrazzo Classic s are Uniform Plumbing Code (cupc), International Plumbing Code (IPC) and National Plumbing Code of Canada certified through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156-2012, CSA B45 Series-2002 (R2013) & ASME A112.18.1-2012/ CSA B125.1-12. Certified to NSF/ANSI 372 Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement.

Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above H O Centrally rising vent with supplies from below Off-line vent with supplies from above Mounting Height Type (select one) STD Standard Height JUV Juvenile Height Sprayhead Type (select one) CLC Classic Sprayhead (entire sprayhead activates) Activation Type (select one) F Foot TTPA TouchTime Pushbutton*** IRP AST4 Infrared Air Pushbutton TTPB TouchTime Piezo Switch*** Water Supply Type (select one) MMV Manual Mixing Valve TMA Thermostatic Mixing Valve Soap Dispenser (select one) PSD Powdered Soap Dispenser LSD Liquid Soap Dispenser MLSD Metal-Clad Liquid Soap Dispenser Terrazzo Bowl Color (select one) Standard Colors GRANITO Granito (Beige) MPSD Metal-Clad Powdered Soap Disp. SA NSD Cube Adapter for Individual Soap Dispensers (dispensers sold separately) No Soap Dispenser WHT-MARM White Marmorite Premium Terrazzo Colors* (available at an additional charge) W-GRAY Whisper Gray* D-ROSE Dusty Rose* Optional Selections Shroud Type SH Stainless Steel Shroud (Conceals Overhead Piping)* NONE No Shroud Support Tube Reinforcement Type TA 1-1/2" Tie Pipe Assembly (not required when SH is selected) NONE No Tie Pipe Assembly Towel Dispenser Type CFTD (2) C-Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser NONE No Towel Dispenser Hose Bibb Type HB Hose Bibb** NONE No Hose Bibb * Non-cancelable, not-returnable ** Available with STD height only. Non-cancellable, non-returnable. *** TTPA and TTPB require a low-voltage UL/CSA listed 120VAC/12VDC plug-in adapter. Towel Dispenser with SA soap option is non-cancellable and non-returnable. Required with drain A, drain O and towel dispenser. Page 2 of 5 4/23/2018

Dimensions (mm) *Juvenile Height for Both Models: Subtract 4" (102) Foot Controlled Adjust to Towel Dispenser Mounting Holes 10-1/4) (260) 6 (152) 37-1/4 56* 36-1/4* (921) 28 (711) 19* (483) 29-1/4* (743) 39-1/8* (994) 47-5/8* (1210) 26 (660) Infrared Controlled Adjust to Towel Dispenser Mounting Holes Infrared Module to be Rounded at Back 10-1/4) (260) 6 (152) 36-1/4* (921) 37-1/4 28 (711) 19* (483) 29-1/4* (743) 39-1/8* (994) 42-5/8* (1083) 51-1/8* (1299) 59-1/2* (1511) 26 (660) Page 3 of 5 4/23/2018

Rough-Ins (mm) Type A Off-line vent with supplies from below Type O Off-line vent with supplies from above. 1" NPT thru Wall (optional) 4-1/2" (114) 1 thru (optional) Stub Up 3" (76) (164) thru (optional) Stub Up 3" (76) 8-3/8" Trap 16-1/2" (stub out to suit trap dimension) (optional) 6-3/8" Trap Center of 1" NPT thru Stub Up 2-1/2" (64) (stub out to suit trap dimension) (optional) Center of Bowl 1" NPT from above must reduce to 1/2" nom. copper tube on these centers to pass thru washfountain. 4" (102) Trap for Wall Outlet Only Drain thru Wall Trap for Wall Outlet Only Clearance Hole B Clearance Hole A A Drain and Drain thru, Trap Located Below 4" (102) Drain thru Trap Located Below Coupling and Nipple Hookups: Use the chart to the right when hookup is made with a coupling and nipple. When trap is installed tight to bottom of bowl, dimension A depends on design of trap. (2" drain through wall must not interfere with diagonal frame member on pedestal). Dim. STD. JUV. STD. JUV. A 11-1/4" to 13-1/4" (286-337) B 12" (305) 9-1/4" to 10-1/4" (235-260) 8-1/4" (210) 6" to 11" (152-279) 12" (305) 6" to (152-216) 8-1/4" (210) Rough-In Notes 1. All pipes and fittings not furnished by Bradley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1", for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. Check valve inlets are 1/2" NPT. 5. UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24" (610). Check state and local codes for variances. Page 4 of 5 4/23/2018

Rough-In Dimensions for Drain and Type B Drain Centrally rising vent with supplies from above. Type H Drain Centrally rising vent with supplies from below. (mm) 1" NPT (Optional) 1 4-1/2" (114) 8-3/8" thru Stub Up 3" (64) 1 1-1/2" NPT Vent to Ceiling Stub Up 3" (76) 1-1/2" NPT Vent to Ceiling Bowl 1" NPT from above must reduce to 1/2" nom. Copper tube on these centers to pass thru waterfountain. 1" NPT thru (Optional) Stub Up 2-1/2" (64) Bowl Vent 8-3/8" 1" NPT Vent 12" (305) (STD. Height) 8-1/4" (210) (JUV. Height) Drain thru Drain thru Wall thru Rough-In Notes 1. All pipes and fittings not furnished by Bradley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1", for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. Check valve inlets are 1/2" NPT. 5. For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" NPT galvanized pipe for vent. Use of plastic or copper for vent is not recommended. Page 5 of 5 4/23/2018