WF2613 Classic Corner Washfountain with 9" Deep Bowl

Similar documents
WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

Installation Instructions

SS-2N Express Lavatory System SS-Series

Installation Instructions

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Installation Instructions

Installation Instructions

Installation Instructions

Express Lavatory System MG-Series

Installation Instructions

Express Lavatory System MG-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

LVSD2 Verge Wash Basin LVS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Washfountain Application Guide

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

AV60 Advocate Lavatory System AV-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

HL45, HL80 Thermostatic High-Low Valves

LD-5010 OmniDeck with WashBar 5000 Series

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

AV60 Advocate Lavatory System AV-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

AV90 Advocate Lavatory System AV-Series

Installation Instructions OBSOLETE

Installation Instructions

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVQD3 Verge with WashBar Technology LVQ-Series

School Solutions Ideabook

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVQD1 Verge with WashBar Technology LVQ-Series

SECTION DOMESTIC WATER PIPING SPECIALTIES

Installation IMPORTANT! Bradley Multi-Station Wall Sink

A. Section Joint Sealants: Seal fixtures to walls and floors.

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

FL-3H, FL-3L Frequency Lavatory System FL-Series

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation and Maintenance Instructions

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Mechanical Inspection Plumbing

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

Transcription:

cupc Certified Available in a 54" Bowl Size 9" Deep Bowl, Designed for Heavy Duty Hand Washing Foot, Air Metering, Infrared or TouchTime Control Specifications Size and Capacity Accommodates three users at a time, using less water, energy and space than lavs equipped with conventional faucets. The operating water pressure range is 20 80 psi. Flow rates differ based on the model. Flow rate controlled by volume control valve. Approximate flow rates for each model: 36" semi-circular: 1.25 GPM 54" semi-circular: 3 GPM 36" circular: 2 GPM 54" circular: 5 GPM WF2613 - With Foot Control Construction Bowl Material Precast Terrazzo: Composed of approximately 85% stone and 15% binder with steel reinforcing rods cast into the bowl. Polished and sealed with urethane resin. Pedestals Pedestals consist of die-formed legs, upper braces, scuff bases and panels: legs are 14 gauge galvanized steel; upper braces are heavy gauge steel coated with a rust preventative; pedestal panels and scruff bases are stainless steel with a #4 finish. Standard Equipment Valves and Fittings In addition to bowl and pedestal, the following valves and fittings are standard: sprayhead with stainless steel supporting tube, restraining bracket, and bowl gasket; spud with locknut and beehive strainer; sprayhead supply line; manual mixing valve; volume control valve; combination stop/strainer/check valves. Activation Controls Foot Control Each press of the foot rail mechanically actuates a hold-open valve, with slow closing upon release of foot pressure. Air Valve Hand Control Each push button pneumatically actuates a non-hold-open, air metering, single-temperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates a flow of tempered water from the non-sectional sprayhead. Push button requires less than five pounds of pressure. Infrared Control Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from the non-sectional sprayhead. Shut-off is automatic seven seconds after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area adapted to, but not exceeding, the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: WF2613 - With Infrared Control Solenoid 24V, 50/60 Hz, 3/4" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Transformer Class II UL/CSA listed, 110/24 VAC plug-in transformer. Plugs into a standard GFCI protected electrical outlet. Location of transformer per local electrical code. TouchTime Hand Control Each low-voltage button actuates a non-hold-open, slow-closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the non-sectional sprayhead. TouchTime controls water flow through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. Push button requires less than five pounds of pressure. Code Compliance and Certifications cupc Certified The Classic s are Uniform Plumbing Code (cupc) certified through the International Association of Plumbing and Mechanical Officials (IAPMO). Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Page 1 of 5 Certified to NSF/ANSI 372

Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above H O Valve (select one) F Foot Control Valve IR Infrared Centrally rising vent with supplies from below Off-line vent with supplies from above Pedestal Height (select one) STD Standard Height JUV Juvenile Height Soap Dispenser (select one) LSD Liquid Soap Dispenser PSD Powdered Soap Dispenser NSD No Soap Dispenser Bowl Color (select one) Standard Color (*Premium color available at additional charge.) GRANITO Liquid Soap Dispenser WHT-MARM White Marmorite D-ROSE Dusty Rose * ** W-GRAY Whisper Gray * ** Optional Selections Thermostatic Mixing Valve TMA Thermostatic Mixing Valve Metal Soap Dispensers MLSD Metal-Clad Liquid Soap Dispenser MPSD Metal-Clad Powdered Soap Dispenser Stainless Steel Shroud SH Stainless Steel Shroud (Conceals overhead plumbing) Paper Towel Dispensers CTD (2) C-Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser Hose Bibb HB Hose Bibb ** 1-1/2" Tie Pipe Assembly TA Cube Adapter SA Reinforces Support Tube (Unvented washfountains) For Individual Soap Dispensers (Dispenser sold separately) ** Non-cancelable, not-returnable. Page 2 of 5

Dimensions (mm) *Juvenile Height for Both Models: Subtract 4" (102) Foot Controlled Adjust to Towel Dispenser Mounting Holes 10-1/4) (260) 6 (152) 37-1/4 56* 36-1/4* (921) 28 (711) 19* (483) 29-1/4* (743) 39-1/8* (994) 47-5/8* (1210) 26 (660) Infrared Controlled Adjust to Towel Dispenser Mounting Holes AZ Module to be Rounded at Back 10-1/4) (260) 6 (152) 36-1/4* (921) 37-1/4 28 (711) 19* (483) 29-1/4* (743) 39-1/8* (994) 42-5/8* (1083) 51-1/8* (1299) 59-1/2* (1511) 26 (660) Page 3 of 5

Rough-Ins (mm) Type A Off-line vent with supplies from below Type O Off-line vent with supplies from above. 1" NPT thru Wall (optional) 4-1/2" (114) 1 thru (optional) Stub Up 3" (76) (164) thru (optional) Stub Up 3" (76) 8-3/8" Trap 16-1/2" (stub out to suit trap dimension) (optional) 6-3/8" Trap Center of 1" NPT thru Stub Up 2-1/2" (64) (stub out to suit trap dimension) (optional) Center of Bowl 1" NPT from above must reduce to 1/2" nom. copper tube on these centers to pass thru washfountain. 4" (102) Trap for Wall Outlet Only Drain thru Wall Trap for Wall Outlet Only Clearance Hole B Clearance Hole A Drain and Drain thru, Trap Located Below 4" (102) Drain thru Trap Located Below Coupling and Nipple Hookups: Use the chart to the right when hookup is made with a coupling and nipple. When trap is installed tight to bottom of bowl, dimension A depends on design of trap. (2" drain through wall must not interfere with diagonal frame member on pedestal). Dim. STD. JUV. STD. JUV. A 11-1/4" to 13-1/4" (286-337) B 12" (305) 9-1/4" to 10-1/4" (235-260) 8-1/4" (210) 6" to (152-216) 8-1/4" (210) 6" to 11" (152-279) 12" (305) Rough-In Notes 1. All pipes and fittings not furnished by Bradley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1", for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. Check valve inlets are 1/2" NPT. 5. UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24" (610). Check state and local codes for variances. Page 4 of 5

Rough-In Dimensions for Drain and Type B Drain Centrally rising vent with supplies from above. Type H Drain Centrally rising vent with supplies from below. (mm) 1" NPT (Optional) 1 4-1/2" (114) 8-3/8" thru Stub Up 3" (64) 1 1-1/2" NPT Vent to Ceiling Stub Up 3" (76) 1-1/2" NPT Vent to Ceiling Bowl 1" NPT from above must reduce to 1/2" nom. Copper tube on these centers to pass thru waterfountain. 1" NPT thru (Optional) Stub Up 2-1/2" (64) Bowl Vent 8-3/8" 1" NPT Vent 12" (305) (STD. Height) 8-1/4" (210) (JUV. Height) Drain thru Drain thru Wall thru Rough-In Notes 1. All pipes and fittings not furnished by Bradley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1", for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. Check valve inlets are 1/2" NPT. 5. For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" NPT galvanized pipe for vent. Use of plastic or copper for vent is not recommended. Page 5 of 5