Similar documents
LED Panel Light Specification List

Technical Application Guide for UP-SHINE LED Track Light

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Panel Light

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application LED Pendant Light LUZ-PL W-W

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

WZ-T8-W18 T8 LED Tube Light

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

ENERGY EFFICIENT LED SOLUTIONS

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

The Future is here & It s Bright!

Technical Application Guide for UP-SHINE LED Spotlight

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

LED Outdoor Wall Light Series

Technical Application Guide for UP-SHINE LED Ceiling light

LED Shoplight fixture

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

Technical Application Guide for UPSHINE LED Ceiling light

FDV BA- Lighting AS BA24-CL76-8WD

LED Ceiling Light. Informations. Application notes. Application Areas PS-AL W(-D,-S) Indoor

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

Greenough Enterprises Co., Ltd.

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Downlight

LED Product Catalogue

Lumination LED Luminaires

1. Key Features and Benefits

Ultra Energy Efficient

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Vaya Linear LP, White & Mono

E10 & L9 Low Wattage Light Cone Data

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

LED RETROFIT CONVERSION KITS

The Commercial LED Lighting Specialist

Corn Light. Applications. Key Features. General Usage. 5years

PRODUCT DATA SHEET LIGHTING PRODUCTS

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

600W LED HIGH BAY LIGHT

Osprey Ultra LED light

ONE LED Installed. ONE LED Petrol Station Retro Fit 80W LED E40 Lamps in Canopies. LED Panel llights & PL LED Retro Fit Lamps in shop.

LED Lamp 6W MR16. A New Experience in Light

PRODUCT COLLECTION

TROFFER RETROFIT KIT (TRK)

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

LED Spotlight 15 W. Information Sheet. Features. ISALUX 15 series

Urbanlite. We light your world IK08 IP

LED Tri-proof Light. LED Tri-proof Light SPEC. Microwave Motion Sensor. Option: Remote control. Suitable for a variety of scenes

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

SUPERNOVA INTERNATIONAL

LED RETROFIT SOLUTIONS

Technical Application Guide for UP-SHINE LED Ceiling light

POWERED BY PRODUCT CATALOGUE

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Liteharbor Lighting Technology Co., Ltd.

High Efficiency LED Panel Lights

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

LED Panel Light E830J

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

2013 Catalog. RoHS Western Way, Suite 155 Jacksonville, FL

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

The Commercial LED Lighting Specialist

PRODUCT CODE FIXTURE COLOR OPTICS WATTAGE COLOR TEMP + HOUSING DRIVER VOLTAGE

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

The Commercial LED Lighting Specialist

110 lm w STANDARD SERIES

LED RETROFIT CONVERSION KITS

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

LUXCOMFO TM LED Flood Light Datasheet

LED TRACK LIGHT.

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

High Lux Performance White LED MR16 Lamp

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

Recessed and surface mounted LED downlight family

Product Specifications MaxLumen MRI LED Diffused Lighting

HIGH LUMINOUS EFFICIENCY

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

LITE SUSPENDED CEILING. Minimal design and incredible attention to detail, LITE. features high performances optics with perfect light

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

lumen & ecoluz sustainable lighting by eco:d 1

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED Edge-Lit Flat Panels

Transcription:

The design criteria of the AOD panel light was focused on the essential basic requirements of modern lighting, visibility and eye comfort.with the elimination of the normal mains frequency flicker and with a light energy spectrum based on the human eye requirements the AOD panel light delivers comfortable lighting for all applications. AOD LED panel light is a new style surface lighting source which is designed by using LCD back light technology LCD back Thanks to the high transmittance light guide plate the light is well diffused in an effort to completely eliminate glare as well as eliminating the use of other light distribution devices such as diffusers.the end result being a soft comfortable light whilst still maintaining lighting levels to comply with world standards. The unique thin design renders itself to be used as a retrofit or as new installations. The sizes offered are so that the panels can be fitted to existing recessed light ceiling apertures making it a very time and cost effective way of replacing those tired old troublesome tube style light fittings. Safety features of the AOD panel light include not only the elimination of hazardous substances such as mercury and others found in ballasts and power faction correction devices.the panel itself also has the added feature of being extra low voltage making it safe for authorized installers. The high efficacy as well as the almost perfect colour rendering index combined with extremely low light loss over long periods (see chart ) and virtually no maintenance makes this light an ideal replacement where the old style tube lighting would otherwise be used.in the process achieving considerable savings in power consumption, maintenance and environmentally responsible disposal of mercury filled tubes thus reducing the overheads associated with old style lighting. The AOD panel light is also designed with modern décor as a prerequisite. The anodic oxidation aluminium alloy frame not only solves the heat-dissipation problem but also makes the whole light a classic clean fuss free appearance enhancing the beauty of light. LED Panel light Characteristics Features: No glare and flare, no shadow, no spot, soft and eye-friendly light Light & Thin: only 1.2cm thickness, wide application. Eco-friendly & Energy-saving: high efficiency, No UV or IR radiation, low thermal Well-distributed illumination: high transmittance light guide plate, well- distributed, and wide angle. Stable & durable: long lifespan over 30000hrs, low light decay. Convenient installation: Humanization Design, easy installation, in-built or suspending. LED panel light Scope of Application LED panel light is applicable for various public places such as department stores, office buildings, airports, factories etc. anywhere you need general indoor lighting. 1 / 7

AOD LED panel lights Part No. Outline Dimensions LED Power Working Voltage Lumens (lm) CCT(K) PL10-3030 298*298*12.3 mm 10W AC 90~240V 900~1000 5700/6500 PL15-3060 298*598*12.3 mm 15W AC 90~240V 1300~1400 5700/6500 PL20-3060 298*598*12.3 mm 20W AC 90~240V 1700~1800 5700/6500 PL30-30120 298*1198*12.3mm 30W AC 90~240V 2700~2800 5700/6500 PL40-30120 298*1198*12.3mm 40W AC 90~240V 3400~3500 5700/6500 PL30-6060 598*598*12.3mm 30W AC 90~240V 2700~2800 5700/6500 PL40-6060 598*598*12.3mm 40W AC 90~240V 3400~3500 5700/6500 For more product details, please visit our website www.aodevices.com PL40-6060 Parameters Item Symbol Min. Typ. Test Conditions Notes Working Voltage(V) Vin AC185 AC220 AC265 Working Frequency(Hz) F 47 50 63 Light Power(W) Pout 39 40 41 AC220V,25 Input Power(W) Pin 44 45 AC220V,25 Power Factor PF 0.97 AC220V,25 Luminous Flux(lm) Ф 3400 >3500 CCT:5700±200K, Diffuser Plate transmittance 82%, Haze 92% CRI Ra 70 75 80 CCT(K) CCT 2700 6500 optional 1 Working Temperature( ) Temp -20 45 AC220V Lifetime(hrs) MTTF 50000 AC220V,25 Inference by Weight(g) 4000 operating Not including interface/pipe diameter ordinary 2-wire interface package Frame Dimensions 598*598*12.3mm Note: AOD Standard Color Temperature: 2700±150K 3000±180K 3500±200K 4000±250K 4500±250K 5000±300K 5700±300K 6500±500K. Luminous Flux Maintenance Chart 2 / 7

Note: This chart shows the actual test data, which clearly reflects the lumen depreciation of AOD LED panel light. These data were obtained through the test samples worked at 220VAC at the general room temperature and lighted constantly in a long-term. Observers measured the luminous flux, luminous efficiency and other parameters once a month. PL40-6060 Effective Illumination Diagram Lighting area and the average illumination from different projection distance PL30-6060 light distribution curve and illumination diagram (Diffuser Plate transmittance 82%,Haze 92%) Note: Tested in standard Distribution Photometer laboratory (full dark background). Distance between the LED panel Lights and detector is 9.0m; CCT: 5700±200K and CRI 75~80 for the test samples. PL40-6060 Structure Dimensions 3 / 7

A B C D 548.2 mm 548.2 mm 598 mm 12.3 mm Package information 5pcs/carton. The products are protected by foams or EPEs from four angles with interlayer foams or EPEs. 9 cartons/ pallet, 45pcs in total Installation Instructions 4 / 7

1. This product should be installed by trained professional electricians. 2. Please check the integrality of the products when unpack the packing. 3. The distance between this product and any flammable materials must not be less than 0.2m. Make sure the distance between the upper part of the installed light and the ceiling is not less than 2cm. This product must not be installed into ceilings or walls that contain heat-insulating materials. The main cable must not be connected with the low voltage cable or the surface-mounted lights. 4. When laying the cables, make sure the cables and plugs are not subjected to any tensile or twisting forces. Fit the cable tension relieving mechanisms to the connection points of the surface-mounted lights. Do not kink cables. Output cables should be laid separately and at a distance from other cables. 5. After installation, connect the low voltage plug to the switch power supply. 6. Non-professionals are not allowed to disassemble and maintain the products. Our company reserves the right not to provide after-sale service if unauthorized disassembly and maintenance happens to the products. Recommended installation Procedures 1. Put one side of the steel cable into the fixture 2(see accessories below), and set 2 to 5 mm aside. Then, tighten the screw on the fixture 2 with screw-driver. 2. Put the other side of the steel cable through the bigger hole of the 90 fixture (there are big and small holes). Lock the 90 fixtures separately on the four angles of the panel light (if necessary, you can lock the 90 fixture into any screw holes on the back of panel light) 5 / 7

3. Insert the other side of the steel cable into the hole on the top of the fixture 1, push the head of the fixture 1 to adjust the length of the steel cable, thus adjust the position of the whole light. Accessories Attention: 1. The LED panel light should be firmly fixed on expected accessories no matter it is embedded or hoisted. 2. The connection of the wires should be done by professional electricians referring to the installation guide to avoid dangers. 3. The operating voltage cannot exceed the specified range (185~265VAC). 4. Disassembly of the light without permission is forbidden. For any problem please contact our customer After-sale service If you have any questions or problems in the process of unpacking, installation and use, please contact our Customer Service Department. We will respond within 2 hours, and if necessary, we will promptly send our maintenance professionals to reach your 6 / 7

site as quickly as possible to solve your trouble and restore to the normal working condition. AOD takes guarantee responsibility unless otherwise specified in the following circumstances: The breakdown or the damage is caused by incorrect installation, failure operation or use under the Not- specified working conditions. The damage is caused by accident, abuse or misuse. The breakdown or the damage is caused by customers unsuitable safekeeping or transportation. by AOD. The breakdown or the damage is caused by customers disassembly or changing the spare parts to which are not approved The breakdown or the damage is caused by man-made or natural disaster. Customer Service Center:+86-536-2221111 AOD will constantly improve our production performance and insist on innovation. The information contained in this document is the lately data at the deadline for edition and subject to change without notice. AOD reserves the right to the interpretation of this document. The pictures shown here is indicative only. If there is inconsistency between the pictures and the actual product, the actual product shall govern. 7 / 7