Gerber Centrifuge Micro II. Instruction Manual (e)

Similar documents
CR-1730R User s Manual

Hand Dryer Installation & User Manual

POLYMIX PX-IG 2000 Operating Instructions

DOC JAN06 LT 200

E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Centrifuge/Vortex for PCR plates CVP-2

Dry Bath Heating Systems

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

SEMAK VITABLEND STICK BLENDER MODELS VB250, VB360, VB410 & VB510

Manual Page 1 of 8. Manual. Laboratory autoclave

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Packing Instructions Heraeus Primo R

Vacuum Pack Machine Instruction Manual Model GF439-A

English Instructions for use HOB Contents Important safety instructions,5 Safeguarding the environment,6 Eco design declaration,6 Before use,6

TECHNOSKLO Ltd. Držkov

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

IMPORTANT SAFETY INSTRUCTIONS DANGER WARNING

Operating Instructions for Reka Hot-Melt Glue Applicators

WELCOME IMPORTANT SAFEGUARDS

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

INSTRUCTION MANUAL. LOW SPEED CENTRIFUGE ScanSpeed MiniVac And ScanSpeed MaxiVac. Revision : 01 Date : Cat. No. :

IMPORTANT SAFETY INSTRUCTIONS

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

Operational Instructions. Glue Applicator MS Translation from German to English

Concentrator Bedienungsanleitung Instruction Manual Mode d emploi

Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Product Manual Glue Applicators MS 80 and MS 200

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

OPERATING INSTRUCTION MAGNETIC POLISHING MACHINE TYPE PM-200

PureLine D. Technical Specification

Instructions for the fan motor control system, SILVER C

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

FIGARO. 08/52543/0 (UK) Issue 1

ST Wiring diagram. Product description. Four-stage controller. Order number

Centrifuge STANDARD OPERATING PROCEDURE

INSTRUCTIONS CertoClav EL

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Aquamax KF Oil Evaporator. User Manual

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

Hot Plate HPS / HPL. Bedienungsanleitung Instructions for use Mode d emploi Manuale d istruzioni Manual de instrucciones

º CP0398/01 Padholder assy Switch 2-cup

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

IMPORTANT SAFETY INSTRUCTIONS DANGER WARNING

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Instructions for the fan motor control system with integrated wiring terminals SILVER C

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

Dyna-Form Air. Alternating Pressure Relief Overlay System

HX-30/40 and HX-30/40 S Glass and Dishwashers

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Peltier cooler/heater PCH-1 / PCH-2

English Instructions for use

CYGNUS CF VI BLOOD CENTRIFUGE OPERATORS MANUAL

Forehead Thermometer Instruction Manual

Glass and Dishwashers AMX / AUX Series

Model 3.6m. User Manual Original instructions

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operating Manual Bathroom Balance

RÖSLER ULTIMATE SURFACE TECHNOLOGY. High Energy and Vibrator Barrelling Systems. Drying Installations. Water Recycling Systems.

Insta-Therm Series Service, Installation and Operation Manual

Safety and Instruction Manual

Glass and Dishwashers AMX / AUX Series

Centrifuge STANDARD OPERATING PROCEDURE

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

1500kN Concrete Machine. Impact Test Equipment Ltd & User Guide. User Guide

OPERATING INSTRUCTIONS

Super Elite Watch cleaning machine

IMPORTANT SAFETY INFORMATION

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Service Manual. Senseo Twist HD7873/50 HD7873/51 HD7873/52 HD7873/53 13/04. Philips Consumer Lifestyle

AVC085 AVC / AVC / AVC / AVC / AVC / AVC085.21

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

O P E R A T O R S M A N U A L M O D E L S PR 32 / 98 TRANSLATION OF THE ORIGINAL MANUAL

Table of Contents. English

Operation manual for BOD-80. 3, Hagavish st., Holon,Israel Tel: , Fax: Page 1 of 6 pages

DISPENSE SYSTEM. Novocold. Installation and Operation Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

INSTALLATION AND USER INSTRUCTIONS

AUTOMATIC VACUUM UNIT

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

Wake-up Vibration Alarm Model : VR101. User Manual

CREMALDI Cream machines Operating instructions

Winding Turns Tester

Tornado Operations & Maintenance Manual

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Transcription:

Gerber Centrifuge Micro II Instruction Manual (e)

Version: 2004 1

Content Instructions for use 1. Introduction Page 2 2. Safety Precautions Page 3 3. Unpacking Page 4 4. Description of Functions Page 5+6 5. Instructions of use Page 7 6. Safety Features Page 8 7. Cleaning and Maintenance Page 9 Technical description 8. Technical data Page 10 9. Diagram Page 11 10. Spare parts Page 12 11. CE conformity Page 13 2

1. Introduction Safety Features:. The following documentation contains information about the use of the centrifuge. This information will help all users to gain a complete understanding of this centrifuge. Repairs of the control unit and safety devices are permitted only with a written instruction of GERBER INSTRUMENTS LTD and must only be performed by specialized staff. Unprofessional repairs may lead to severe damages. Danger advices: Labelling: When working with electrical control units there are inevitably parts which are under dangerous voltage. Therefore, the control unit must be in a perfect condition before work, to avoid serious body injuries and damages on the unit. All covers, which include electrical working devices are labelled with the following Warning sign: Black arrow on yellow background. 3

2. Safety Precautions General: The centrifuge must be used only by specialized personel and by following these instructions. Please note especially, that: the centrifuge is placed on a firm surface and that the air-holes atthe side of the unit are free. all covers are closed, so that no parts that are under electricty can be touched. the control unit is in perfect condition. the technical safety devices are functionning and have not been manipulated. Labelling: Warning of a danger zone Warning of dangerous electrical voltage Warning of corrosive goods Warning of hot surfaces 4

Carefully unpack the centrifuge. 3. Unpacking Place the centrifuge on a firm table and check make sure that the air-holes at the side of the centrifuge are free. Remove all packing material. Check if voltage corresponds with specification on the label. 3.1. Lid lock system: The lid can only be openend when the centrifuge is powered. To open the lid plug the centrifuge to the main. Put main switch on position I = green lamp and the control lamp brake are on. (Centrifuge is running a self-check!) After approx. 40 sec. the lamp brake will goes off again and the lid can now be opened. In case of cut-off of electricity or if the centrifuge is not connected to the mains, the lid can be opened manually. See also instructions in section SAFETY FEATURES. 3.2. Transportation: To avoid damage during transportation, the bushings are packed separately. In order to assure best possible balancing, the bushings are marked pair-wise and must be inserted in the opposite positions in the rotor. 3.3. Balance of Bushing-Weight: The bushings are numbered pair-wise. The matching numbers are placed in the opposite positions. The numbers are printed on the bottom of the bushings. 5

4. Description of Functions Functions of digital display: (1) Temperature The heating warms up the inside chamber of the centrifuge. Its function is to warm up the butyrometer, which have to be read at 65 C. As the reaction between of the sulphuric acid and milk mixture produces heat as well, the temperature is set at 55 C at the factory.the butyrometers are placed in the waterbath to get the exact reading temperature. The digital display shows the required temperature. The pre-set temperature of 55 C can be adjusted. The potentiometer which is placed under the temperature display can be adjusted in the needed direction with a screw driver. (2) Time The running time can be set individually on the digital display. (It is set in minutes!) After expiring of the programmed running time, the brake activates automatically. Functions of the control lamps: (3) run lights on when centrifuge is running (4) brake lights on when the brake is activated (5) lid lights on when lid lock is unlocked (6) heating lights on during the heating time. It shuts off when the required temperature is reached. 6

Functions of the heating: The heating is thermostatically controlled. It can be shut off or can be adjusted to any needed temperature in the range of 5 C over room temperature up to 65 C. The temperature in the centrifuge is set at the factory at 55 C. Please refer also to remarks under Functions of the digital display: (1) Temperature on page 5. Centrifuge is used without heating: To use centrifuge without heating set the required temperature below room temperature. This shuts off the heating. Centrifuge is used with heating: Usually the centrifuge is used with heating. As soon as the motor is running, the heating is automatically on. 7

5. Instructions of use 5.1 First start-up -centrifuge is placed on a firm ground -the centrifuge case will warm up if the heating is used. -Therefore, do not use the centrifuge close to material sensitive to heat. -plug to mains. IMPORTANT: make sure mains is earthed. 5.2. Daily routine work a) Main switch is on. The centrifuge is running a self-check. (control lamp brake light on) After 40 sec. the LED control lamp brake lights off and the centrifuge is ready to use. b) Fill the butyrometer in opposite positions into the rotor, thus to avoid any unbalance. c) Close lid and presss START/STOP button. After running time has ended the centrifuge stops automatically. The lid can be opened once the brake control lamp has shut off. Attention: the butyrometers are warmed up due to the chemical reaction of the sulphuric acid/milk mixture. Sulphuric acid can be spilled due to glass breakage. 8

6. Safety Features 6.1. Lid lock system: keeps you from operating the centrifuge with the lid open and allows to open the centrifuge only after a complete stand still. In case of cut-off of electricity or if the centrifuge is not connected to the mains, the lid may be opened manually. Unplug the plug, unscrew the plastic cover (grey) and pull the ring to the outside with a hook. 6.2. Unbalance shut-off: (OPTIO AL) The automatic unbalance shut-off device shuts the centrifuge off in case of excessive vibrations. The sensitivity of the shut-off is calibrated at the factory. If the unbalance device becomes active, the centrifuge is stopped and the error message appears on the panel. The centrifuge can only be restarted when the lid has been opened and closed again. 9

7. Cleaning and Maintenance Always remove lead before starting any repair work. Keep the centrifuge compartment clean. After glass breakage of a filled butyrometer, sulphuric acid can be spilled in the compartment. It is very important, that the bushings and the compartment of the centrifuge are immediately and thoroughly cleaned. Corrosive acids may damage the centrifuge. For cleaning please follow the relevant guidelines for handling with chemicals. 10

8.Technical data for MIKRO II Power supply Motor 230V +/- 15% 50-60 Hz 115V +/- 15% 50-60 Hz collector-less motor IP54 isolation class F Power Motor 90W Heating 600W Speed Temperature Timer Dimensions (BxTxH) fixed speed: 350xg +/- 50 thermostatically controlled 5 C from room temperature upto 65 C set at the factory at 55 C 0...60 minutes 43x46x28 cm 11

9. Diagram 12

10. Spare parts MIKRO II 03.16269 Butyrometer bushings 03.16015 Motor 220 V 03.16016 Motor 115 V 03.16820 Lid lock 220 V 03.16821 Lid lock 115 V 03.16845 MP-control unit complete 03.16850 Heating 220 V 03.16851 Heating 115 V 13

Declaration of conformity GERBER INSTRUMENTS certifies that the instrument Centrifuge U IVERSAL/COMPACT/MICRO II complies with the requirements of the of the following European Council Directives and carries the CE mark: 89/336/EWG Safety Requirement for machines 89/336/EWG Electromagnetic compatibility 93/68/EWG Electrical Safety for low voltage equipment 09/99 14