Solatube Daylight Dimmer Installation Instructions

Similar documents
Garage Ventilation Installation Instructions

Installation Instructions Remote Blowers

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Bath Fan with Light User s Guide

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Integrated Ventilation System

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

e Bath Fan with Light User s Guide

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Ceiling Fan Installation Instructions

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

2 PREPARE THE OPENING

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Electric Dryers Instructions 01

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ST. KITTS CEILING FAN

Installation Instructions Preference Wall Mount Range Hood

breeze easytm model # F100-1W

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

e Heater/Exhaust Fan/Light User s Guide

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

CONTENTS WIRING DIAGRAM

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

High Power Range Hood

Humidity and Thermostat control box for Attic Fan

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Installation Instructions 30 French Door Built-in Wall Ovens

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Installation Instructions

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Installation instructions for the T 9820 Gas Dryer

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

MaxLite LED Round Pendant Highbay Series

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Installation Instructions Induction Cooktop

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

IMPORTANT INSTRUCTIONS READ & SAVE

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

IdealFILM. Do-It-Yourself Installation Manual

Please Read and Save These Instructions Safety Information

Installation Instructions

INSTALLATION INSTRUCTIONS

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

IMPORTANT INSTRUCTIONS READ & SAVE

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Installation Instructions

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

VENTILATION FAN WITH LIGHT AND HEATER

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Installation Instructions

TOUCHDOWN 48 CEILING FAN

Table of Contents. What to Expect with. Mounting Options. Tools Needed

CEILING FAN OWNER'S MANUAL

Ceiling Fan Installation Instructions

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Ceiling Fan Installation Instructions

Installation Instructions

PLEASE READ AND SAVE THESE INSTRUCTIONS

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

Dishwasher Installation Instructions DW 24XT/DW 24XV

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

Fillmore Small Pendant Assembly and Installation Instructions

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Transcription:

Solatube Daylight Dimmer Installation Instructions Please read all warnings and instructions before beginning installation. b, e a ADDENDUM TO PARTS LIST Quantity. Daylight Dimmer (). Seal and Fastener Kit () a. - (50 mm) wide x 7 (.8 mm) () b. Screws (Phillips) #8 x /8 (9 mm) () c. Romex connector () d. Strain Relief / ( mm) () e. Screws (Phillips) #8 x 5/8 (6 mm) Drill Tip (). Daylight Dimmer Switch (sold separately). a. Switch: DPDT Momentary, Rocker, Snap-In (5V, 00mA with Cover Plate) b. Cable: i. Switch Circuit: () Conductor, Stranded Copper, ga, (Green, White, Red and Black) 0 ft. c. Screws: () #6 Recessed Oval Slotted. Two () Conductor Cable for Multiple Units (sold separately, not pictured) a. () Conductor, Stranded Copper, ga, (Red and Black) 500 ft. c d a b c

WARNING Do not proceed with the installation until you have read the entire instructions, including these warnings. (Use of materials or methods not authorized by Solatube International will result in an invalid warranty.) Solatube International, Inc. (seller) assumes no responsibility or obligation whatsoever for the failure of an architect, contractor, installer, or building owner to comply with all applicable laws, ordinances, building codes, electrical codes, energy codes, fire and safety codes and requirements, roof warranties and adequate safety precautions. Installation of this product should be attempted only by individuals skilled in the use of the tools and equipment necessary for installation. Protect yourself and all persons and property during installation. If you have any doubt concerning your competence or expertise, consult a qualified expert before proceeding. Install at your own risk! Solatube product installations may be dangerous and include the potential for death, personal injury and property damage. The hazardous conditions include but are not limited to the following: During installation, the Solatube Daylighting System s reflective tubes may focus sunlight, causing intense heat or fire. Remove protective film only after the parts have been installed. Prior to and during installation, do not leave tubes in contact with combustible materials or unattended, especially near direct sunlight. Avoid skin burns. Solatube Daylighting System and Solar Star products may have sharp edges. Always wear leather or canvas gloves while handling and installing products. Solatube product installations require climbing and working at dangerous heights, including on ladders, scaffolding, roofs and in attic spaces. Risk of death, personal injury and property damage may result from a fall, or from falling objects. Use extreme caution to minimize risk of accidental injury, including, but not limited to the following procedures: Clear area below your work space of all people, animals and other items. Avoid working on surfaces that are slippery or wet. Use foot-wear with excellent traction. Use only strong, well supported ladders. Work only in calm dry weather. When in the attic, ensure that your weight is supported at all times with structurally sound framing; drywall material is not designed to carry a person s weight. To reduce the risk of fire, electric shock, and personal injury, basic safety precautions should always be followed when using electric tools, including always wearing safety goggles or other suitable eye protection, and ensuring work area is clear of all electrical wires, gas pipes, water pipes, and other obstacles. When working in the attic or other dusty areas, use of a mask or respirator is recommended to avoid lung irritation. Attic spaces may be dark, confined, and subject to extreme temperatures. Beware of sharp protruding objects. Do not attempt installation without having someone within range of your voice or close enough to come to your aid if necessary. Solatube products are not designed to withstand the weight of a person, tools or other objects. Walking or placing objects on the system could cause personal injury and property damage. If the product is damaged, the structural capacity may be weakened; therefore the system should be repaired immediately. For safe installation and use, do not deviate from these installation instructions. For all electrical components Before installing, servicing, or cleaning unit, switch power off at service panel and lock service panel to prevent power from becoming switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel. Re-Roofing Solatube products require special care if removed for re-roofing. In order to ensure proper removal and re-installation, please contact your Solatube International representative. Please refer to the installation tips for the appropriate product below. Daylighting Systems Installation Tips These instructions are a step-by-step guide for the installation of a Solatube Daylighting System in the following conditions. For other roof types, please contact your Solatube International representative for additional information. Built Up Flat Roof - Single Ply/Membrane - Asphalt Shingle - Low/No Pitched - Pitched - Prefabricated Curbs - Metal Roof Panels

Daylighting Systems Installation Tips (Continued) Allow at least - hours for the installation, particularly if this is your first installation. During the day, turn off all the lights in the room to see how much natural light comes in through the windows, and determine the best position for the Solatube Daylighting System. To light a specific area, place the system over the area, not in the center of the room. This will prevent the desired area from being shaded by tall objects in the room. Measure the distance between the roof and the ceiling. If you don t have enough tubing, contact your Solatube International representative for additional tubing. Avoid roof locations shaded by trees, ridges and chimneys, or near water channels or valleys. Also avoid roof areas with obstructions such as fire sprinklers, HVAC equipment, gas, water or drain pipes, air ducts or flues and make sure that the roof is adequate to endure an installation without damaging its waterproofing properties or weakening the building structure. All adhesives, seals and tapes are recommended to be applied to a clean and dry surface at a minimum of 70 F ( C) for maximum performance. tape contains a pressure sensitive adhesive and pressure must be applied at all seams for proper bonding. tape is not intended for use as structural support of the extension tubes. For structural integrity use manufacturer supplied fasteners on all overlapping extension tube joints. Daylight Dimmer Installation Tips Install Solatube Daylight Dimmer only on a properly aligned Solatube Daylighting System. Use only UL recognized components approved for this listing. Light Add-On Kit Installation Tips To be installed by qualified electricians only. Disconnect power before installation. For supply connections, use wire rated at least 60 C. Access above ceiling to junction box is required. Blinking light may indicate improper lamp wattage or type, or insulation is too close to fixture, or other condition causing overheating. Intended for installation with / in ( mm) minimum spacing from the fixture to cavity surfaces (side wall and overhead building member) and in (5 mm) minimum spacing to adjacent fixtures. Thermally Protected Type IC (insulation may contact housing). Suitable for wet and damp locations such as laundry, bathroom and shower stall. Must use GFCI circuit if located within a bath/shower stall. Use only as a component of Solatube Daylighting System products. Caution Risk of fire and electrical shock. Most dwellings built before 985 have supply wire rated 60 C. This product is to be installed by qualified electricians only. To reduce the risk of fire, use only: Fluorescent Lamps, Medium Base - Watt Maximum, Total Maximum Length / in (0 mm) Compact Fluorescent ( Pin Quad Tube) 6 Watt only Ventilation Add-On Kit Installation Tips See Ventilation Add-On Kit installation instructions for tips. Solar Star Attic Ventilation Installation Tips Keep Solar Star solar panels covered until product is mounted and sealed to roof. Cover solar panel whenever motor, fan, or unit is to be serviced. Fan blade is controlled by the solar panel and may become operational when panel is exposed to sunlight. Solar Star products are designed for general ventilation purposes only. Do not exhaust any hazardous materials or gases such as flammable, explosive or incendiary materials. Solar Star products have an unguarded fan blade. Do not use Solar Star products in areas that are easily accessible. Caution Carbon monoxide may be drawn into a house or attic space with the operation of Solar Star products if fuel-burning equipment is not serviced or monitored regularly. Carbon monoxide (CO) is a colorless, odorless gas that can be hazardous to your health and may cause death. Fuel-burning equipment must have proper ventilation, Solar Star products are not designed to provide ventilation for fuel-burning products.

OVERVIEW These instructions are for installing and wiring the Solatube Daylight Dimmer. Units are designed to operate in a temperature range of -0 F (-9 C) to 0 F (5 C). If ambient temperatures are outside of these values or the environment is very humid, wrap the junction box with an insulation blanket with a vapor barrier. Junction box should be oriented towards the closest source of power with UL label arrow pointing up. Diagram A /8 screw Diagram B Daylight Dimmer /8 screw 5/8 screw drill tip Transition Box Junction Box Step. For Solatube 60 DS (0 in/50 mm Daylighting System) or Solatube 90 DS ( in/50 mm Daylighting System) - Place Daylight Dimmer atop the outside of the bottom tube. Secure the Solatube Daylight Dimmer ring using () /8 (9 mm) screws in the pre-drilled holes. Apply foil tape around perimeter of the Daylight Dimmer (Diagram A). For the Solatube -C ( in/50 mm Daylighting System), orient the Daylight Dimmer around the outside of the transition box so that the locator tabs drop into the slots on the transition box. Secure the Daylight Dimmer using () 5/8 (5.5 mm) drill tip screws in the pre-drilled holes. Apply foil tape around perimeter of the Daylight Dimmer (Diagram B). Diagram C Red Black Green White Step. For Solatube 60 DS (0 in/50 mm Daylighting System) or Solatube 90 DS ( in/50 mm Daylighting System) - Adjust extension tube to the small notch/larger diameter to fit into the Daylight Dimmer. Insert extension tubing atop the inside of the Solatube Daylight Dimmer with () /8 (9 mm) screws in the pre-drilled holes. Apply foil tape around perimeter of the Daylight Dimmer (Diagram A). For the Solatube -C ( in/50 mm Daylighting System), insert the bottom angle adapter into the top of the Daylight Dimmer and secure with () /8 (9 mm) screws in the predrilled holes. Align seam of extension tube with axle on Daylight Dimmer to avoid binding baffle. Apply foil tape around perimeter of the Daylight Dimmer (Diagram B). Diagram D Return to Solatube standard installation instructions to continue with installation. DC Control Switch and Daylight Dimmer Step. Position switch on wall; minimum 8 (.5 m) above floor; within visual sight of the Solatube Daylighting System. Run cable ( conductor gauge with red, black, white and green colors) from the Daylight Dimmer Switch to the Daylight Dimmer junction box. Diagram C illustrates the four terminal locations and their respective conductor. Diagram D provides a completed overview of the entire wired assembly for the Solatube Daylight Dimmer junction box. Using pliers, clamp cables in /-inch strain relief and press into junction box hole from the outside. Two Conductor Gauge DC to succeeding unit Four Conductor Gauge DC from switch Romex,Flex or Conduit

DC Control (Multiple Units/Daisy-Chain) Step. Controlling multiple (two or more) units from one master switch requires () conductor cable, black & red, gauge stranded (not included). Use only gauge wire to fit properly. Connect each unit via terminals to (red to red) and to (black to black) (Diagram D). This will require () conductors per terminal. MULTIPLE UNITS Notes for Controlling Multiple Units:.) The maximum number of units that can be controlled from one master switch is ten (0)..) Maximum distance from the wall switch to the first dimmer in the series cannot exceed 00 feet..) Maximum distance between each subsequent dimmer cannot exceed 0 feet. Diagram E N L Pigtail Supply AC to Power Supply for a single unit installation and to each unit in a multiple unit installation. Electrical disconnect such as fuse or breaker switch must be utilized in supply circuit and disconnected during installation to protect personnel and Daylight Dimmer. Rating: 90-77 V, 50/60 Hz, 0 A(Max). Wire Size: 6 to ga. Connect: Conductors to labeled terminal block on Power Supply (Diagram D). For multiple installations, utilize pigtails from the terminal block to supply AC to each unit (Diagram E). For North America: Black Conductor to Terminal (L) Line White Conductor to Terminal (N) Neutral Green Conductor to Terminal For Europe: Brown Conductor to Terminal (L) Line Ground/Earth Light Blue Conductor to Terminal (N) Neutral Green/Yellow Conductor to Terminal Ground/Earth 5