Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Similar documents
Thermo Scientific 1300 Series A2

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

LABORATORY CABINETS 103

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Heto PowerDry LL1500 Freeze Dryer

Thermo Scientific Precision Ovens

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Down flow clean air cabinet Star of the Universe. Fortuna

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Efficient, safe and easy

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

B. Design meeting requirements of the particular class and type of cabinet as follows:

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Clean Bench Animal Transfer Stations

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Thermo Scientific Heratherm Heating and Drying Ovens

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Microbiological Safety Cabinets

Environmental Health and Safety Biological Safety Program Guidance Document

Low Noise, Class II Microbiological Safety Cabinets The Industry's Most Comfortable, Energy Efficient Cabinet

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

Safely Using a Centrifuge Near a Biological Safety Cabinet in Your Cell Culture Laboratory

INCREASE YOUR LAB EFFICIENCY

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

Biological Safety Cabinets or Fume Hoods Which one to use?

Safe Operating Procedure (Revised 2/10)

INCREASE YOUR LAB EFFICIENCY

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

Ergonomic and Green Class II s

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

BIOLOGICAL SAFETY CABINET

5.0 Installation Instructions

AirGard. Air Flow Monitors

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

Controlled Environment Equipment Solutions for the Lab

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

INCREASE YOUR LAB EFFICIENCY

Class II Biological Safety Cabinets The World's Leading Energy Efficient, Quiet, and Compact Biosafety Cabinet.

Microbiological Safety Cabinet

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

NEW! TSX Series high-performance undercounter refrigerators

Airstream Class II, Biological Safety Cabinet (E-series),

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

NEW! TSX Series high-performance undercounter refrigerators

Innovation in air purification unmatched air quality

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

L a b o r a t o r y E q u i p m e n t C a t a l o g

INCREASE YOUR LAB EFFICIENCY

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

PART III. Laboratory equipment

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Florida International University. Biosafety Cabinet Program

ice 3000 Series Atomic Absorption Spectrometers

Biological Safety Cabinets. Biological Safety Cabinets

Mars. Mars Class 2. Microbiological Safety Cabinets. ScanLaf...Advanced Designs for your Safety & Comfort. Class 2 Safety Cabinets

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

BioSafety Cabinet- Class 100

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

2 Microbiological Safety Cabinet

Thermo Scientific Heratherm Microbiological Incubators

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Appendix C IBC Safe Use of Biosafety Cabinets SOP

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

for the next generation

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Remote Alarm Panels Features

Biological Safety Cabinet

Thermo Scientific HERAfreeze Freezers Solutions for safe sample storage

IBC Position on Bunsen Burner Use in Biosafety Cabinets

The ultimate microbiological safety cabinet

Transcription:

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet Superior Ergonomics, Uncompromising Safety Analyze Detect Measure Control TM ELECTRON CORPORATION

Redefining the Standard in Ergonomics and Safety If you re working with hazardous or potentially hazardous biological materials, you can t afford to compromise on safety. However, many other biological safety cabinets in the market require that you do just that, with poor, cramped design resulting in physical strain and fatigue. And physical stress can lead to mistakes where even the simplest pipetting procedure can become a major risk. Thermo Electron s new Forma 1400 Series biological safety cabinet virtually eliminates these risks. Based on almost 40 years of R&D experience, we ve created a superb Class II, Type A2 biological safety The Quietest Cabinet Available A difference of 3 dba is equivalent to a 50% decrease in sound level. At just 61 dba, the Forma 1400 Series reduces sound level to less than half the level of comparable biological safety cabinets. This allows you to work for longer periods without the usual fatigue caused by blower noise. cabinet that combines superior ergonomics and a technologically advanced design, providing you with the quietest, most comfortable and safest working environment available. Creating the perfect environment for safe, routine operation The Forma 1400 Series virtually eliminates compromises in biosafety work. By improving operator comfort, the Forma 1400 Series seeks to eliminate errors and potential hazards caused by difficult working conditions and accelerated fatigue. The Forma 1400 Series also keeps the room temperature at a comfortable level due to its advanced motor technology that reduces power consumption by at least 50%. With its angled front, transparent glass side walls, and low noise level (<61 dba), the Forma 1400 Series ensures maximum operator comfort. More comfort The ergonomic angled front improves the posture of head, neck, shoulder, back and arms. This comfortable, relaxed working position effectively abolishes stress and strain and associated muscularskeletal disorders during extended working procedures. Transparent glass side walls and a coated back wall ensure a bigger, brighter work area by reducing harsh reflections and glare. Allowing more natural light into the chamber means visibility is improved and operator eye strain reduced. Noise levels are reduced to less than half the level of comparable biological safety cabinets. Operating at less than 61 dba, the Forma 1400 Series reduces noise-related headaches and stress and makes it easier to communicate with colleagues. Cabinet height can be positioned at the proper level on a stationery stand, or it can be adjusted quickly to a range of positions with the motor-driven electric stand.

The Forma 1400 Series hinged cabinet front and sliding sash makes it easy to reach all interior surfaces for easy and thorough cleaning. The Forma 1400 Series is an NSF-certified Class II, A2 biological safety cabinet that provides uniform downflow. Enhanced safety The motorized sash automatically stops at the safe working height of 8 or 10 inches (depending on model). The Forma 1400 Series ensures operator safety through a built-in microprocessor controller that continuously monitors airflow performance and displays the read-out as a highly visible real-time bar graph. In the event of an unsafe condition, both audible and visual alarms are provided. UV operation is prevented unless the sliding slash is fully closed. Greater convenience Push-button sash operation allows easy, one hand opening and closing especially convenient on 6-foot cabinets. The optional foot switch allows operators to open the cabinet when their hands are full. The hinged cabinet front allows the inner surface of the sash to be easily and thoroughly cleaned, while rounded corners facilitate thorough, effective cleaning of the work area. Cabinet choices include a 10-inch opening for easier access, or 8-inch opening for lowest sound level (<61 dba). An intuitive user interface enables programming of all key functions, including UV timer, auto-start and alarms. Technologically advanced The Forma 1400 Series unique advanced motor technology reduces power consumption by at least 50% compared to cabinets with standard induction-type motors. Half-speed motor operation conserves energy, and by reducing airflow volume during periods of non-use, extends HEPA filter life. The optional UV light with programmable timer is mounted directly above the work surface. This makes decontamination more effective, reduces decontamination time and prolongs bulb life. Available in 4-foot and 6-foot nominal widths, the Forma 1400 Series can accommodate a variety of application and space requirements.

The built-in microprocessor controller ensures operator safety. The graphical display panel (shown above) provides a constant read-out of airflow performance. The armrest (shown right) enhances user comfort during extended work sessions. Accessorize your cabinet to meet your specific needs Adjustable support stand The support stand can be adjusted in 1-inch increments to provide work surface heights from 30 to 36 inches. Adjustable feet ensure a level surface. Electric support stand The optional motor-driven stand allows push-button adjustment of the work surface height from 28 to 36 inches to provide the most comfortable position for each individual. Armrest The armrest enhances user comfort during extended work sessions, supporting an ergonomic posture. Sitting just above the intake grill, it also prevents operators from accidentally blocking the grill with their lab coat sleeves. Exhaust transition For researchers working with minute quantities of volatile toxic chemicals and trace amounts of radionuclide, vapors or odors, an exhaust transition with a zero leak damper is available. Designed to NSF standard 49, this connects the Forma 1400 Series to an external exhaust system. UV light The optional UV light is mounted just above the work surface for optimum effectiveness. The user can program the duration of light activation from 1 min to 24 hrs, to provide the desired decontamination cycle. When not in use, the UV lamp flips back into the rear wall, avoiding any turbulence in the laminar airflow stream. Foot switch A convenient foot switch is available to operate the motorized front sash when the researcher s hands are full. Divided table top A sectional work surface is available as an option for both 4-foot and 6-foot cabinets. Each stainless steel section is 12 inches wide, and sections are easily removed for cleaning and autoclaving.

New levels of comfort and safety The Forma 1400 Series is a cutting-edge biological safety cabinet, combining advanced features and an innovative design to provide maximum support for your most critical biological safety requirements: Operator comfort and safety Sample integrity Environmental security Operator Comfort and Safety Nowhere is comfort more essential than in biosafety work. Operating in cramped conditions can make even the simplest procedure not just difficult and time-consuming but often truly hazardous. The Forma 1400 Series ergonomically advanced design and sophisticated controls ensure maximum operator comfort and safety. Sample Integrity Effective decontamination combined with ease of cleaning ensure uncompromising sample integrity. Even the busiest laboratories with constantly changing operators and tasks will find the Forma 1400 Series virtually eliminates these concerns. Environmental Security The Forma 1400 Series meets all NSF 49 standard requirements for Class II, A2 biological safety cabinets. For researchers working with minute quantities of volatile toxic chemicals and trace amounts of radionuclide vapors or odors, an exhaust transition with zero leak damper is available. The Forma 1400 Series advanced motor technology operates 50% more efficiently than a standard induction type, resulting in lower power consumption, reduced heat emissions, longer life and operational cost savings. Ergonomic angled front improves operator comfort by ensuring correct posture. Motorized sliding sash simplifies opening and closing and stops automatically at a safe working height. The hinged front facilitates cleaning of the sash interior. The Forma 1400 Series provides a constant read-out of airflow conditions to ensure operator safety. A microprocessor controller continuously monitors and displays both down-flow and inflow air velocities. A bar graph indicates filter load and allows for timely filter change scheduling. Visual and audible alarms warn the operator of potential hazards. Optional UV light is mounted very close to the work surface, ensuring highly effective irradiation and decontamination. When not in use, it flips into the back wall to eliminate any airflow disturbance. Increased working area and enhanced, non-glare illumination through glass side walls improve the overall working environment.

Complete Sample Preparation Solutions Forma 1400 Series Class II, Type A2 Biological Safety Cabinet Specifications Specifications 4-Foot Model 6-Foot Model Model number 1440 (10-inch sash opening) 1460 (10-inch sash opening) External dimension (with 30-inch work surface height) 1448 (8-inch sash opening) 1468 (8-inch sash opening) D x W x H inches 35.3 x 52.8 x 86.0 35.3 x 76.4 x 86.0 D x W x H mm 897 x 1341 x 2184 897 x 1941 x 2184 Internal dimension D x W x H (front/rear) inches 22.9 x 47.3 x 27.6/24.7 22.9 x 70.9 x 27.6/24.7 D x W x H (front/rear) mm 582 x 1200 x 701/627 582 x 1800 x 701/627 Weight, lbs. (Kg) 496 (225) 661 (300) Spillage containment, Gal. (Liter) 15 (57) 23 (87) Exhaust volume, CFM* 328-361 (Model 1440) 263-289 (Model 1448) 493-543 (Model 1460) 394-434 (Model 1468) Exhaust duct connection 8-inch 8-inch Air velocity, inflow, FPM 100 110 100 110 Air velocity, downflow, FPM 55 nominal Model 1460 55 nominal Model 1468 50 nominal Noise level, 10-inch sash opening <63 dba <65 dba Noise level, 8-inch sash opening <61 dba <63 dba Light intensity, foot candle (Lux) > 111 (>1200) > 111 (>1200) Supply voltage/frequency 115 volts, 60 Hz 115 volts, 60 Hz Power consumption, Watts 482 800 Supply Amp Circuitry 20 Amps 20 Amps Electrical plug NEMA 5-20P NEMA 5-20P Outlets (2) GFCI protected duplex 120V (7 Amps total) GFCI protected duplex 120V (7 Amps total) *Add 30% to CFM values if using an exhaust transition with the cabinet. Ordering Information 4-Foot Model 6-Foot Model Catalog Numbers Forma 1400 Series, Class II, A2, BSC 115V, 60 Hz with 8-inch sash opening 1448 1468 Forma 1400 Series, Class II, A2, BSC 115V, 60 Hz with 10-inch sash opening 1440 1460 Options and Accessories* Adjustable height stand, 30 inch to 36 inch (CI) 191850 191851 Electrically operated adjustable height stand, 28 inch to 36 inch (CI) 191852 191853 UV Light (CI) 191854 191855 Armrest (CI) 191857 191858 Exhaust transition with zero leak damper (CI) 191859 191860 Divided table top (4-Foot: 4 sections, 6-Foot: 6 sections) (FI) 191863 191864 IV Rod (CI) 191861 191862 Utility service valve: Gas, Air, Vac, includes flex fitting (one supplied standard; accommodates 3 additional valves) (CI) 191856 191856 External controls, (Relay) provides interlock between cabinet power on switch and exhaust roof blower (FI) 191868 191868 Foot switch to open/close motorized sash (CI) 191866 191866 Minihelic gauge, mounted in center of rear wall (FI) 191865 191865 *All accessories listed are for the Forma 1400 Series biological safety cabinet only. CI = Customer Installed FI = Factory Installed All models are UL Listed to United States and Canadian requirements and NSF Listed. 2005 Thermo Electron Corporation. All rights reserved. Forma is a registered trademark of Thermo Electron Corporation. Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local representative for details. ELECTRON CORPORATION North America: USA +1-866-984-3766, Canada +1-905-332-2000 Europe: Belgium +32 2 482 30 30, Denmark +45 48 16 62 00, Finland +358 9 329 100, France +33 2 28 03 20 00, Germany/Austria/Switzerland +49 6103 4081012, Italy +39-02-2511141, Netherlands +31 76 571 4440, Russia/CIS +7 095 755 9045, Spain/Portugal +34 93 2233154, Sweden +46 8 742 03 90, UK/Ireland +44 870 609 9203 Asia: India +91 22 2778 1101, Japan +81 45 453 9220, China +86 21 5465 7588, Other Asian countries +852 2885 4613 Countries not listed: + 33 2 28 03 20 00 BRO-LSPF1400-0605