LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Similar documents
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

C-NRPP Quality Assurance Guidance for Radon Test Devices

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Measurement Devices. Topic 5 - Audio 56

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

Comprehensive Short-Term Radon Survey Report

ALL RADON TESTS WERE SIGNIFICANLY BELOW

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Quality Assurance Plan for Conducting Radon Measurements

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Bethel School District Radon Testing Plan

Radon Detection Specialists, Inc.


Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Certificate of Completion

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

Woodlin Elementary School Date of Report March 14, 2018

Certificate of Completion

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Love the Lungs You re With

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

Certificate of Completion

CHAPTER 240. RADON CERTIFICATION

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

EagleRidge High School. Radon Testing Plan

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Policy Manual. April 21,2015. National Radon Proficiency Program 2015

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Radon Detection Specialists, Inc. Love the Lungs You re With

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

Illinois School District & Daycares

Illinois School District & Daycares

Property of Aztec Home Services LLC

CHARCOAL CANISTER RADON SURVEY QUALITY ASSURANCE PROJECT PLAN

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

2.3 Definitions, General Provisions, and Radon Standards

A new passive integrating detector for measurement of individual radon exposure at working places.

In Schools. Revised Edition. oepa. Aa Bb Cc Dd Ee Radon Measurement. Air And Radiation (6604J)

adsw worth Center, New York State Department of Health, Albany, NY 12201

Testing for Elevated Radon in Oregon Schools Protocol and Plan

RULES AND REGULATIONS FOR RADON CONTROL

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

Dealing With RADON in Real Estate Transactions

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan.

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

CARST Guideline for Conducting Radon Measurements as Part of a Real Estate Transaction of Residential Dwellings in Canada (draft)

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Dealing With RADON in Real Estate Transactions

RADON LAZERWEB SERVICES

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

Property Inspected: 623 Pine St, Macon, GA 31201

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

Home Buyer s and Seller s Guide to Radon

radon Keeping your home safe from radon

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Testing for Elevated Radon in Oregon Schools

Radon Testing Results. City Hall

AIR POLLUTION Uncertainty Exists in Radon Measurements

AVERAGE RADON CONCENTRATION:

U.S. Environmental Protection Agency, Radon Division Washington, DC

Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No )

EPA estimates that radon causes thousands of lung cancer deaths in the U.S. each year.

Home Buyer s and Seller s Guide to Radon

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Guide for Radon Measurements in Residential Dwellings (Homes)

Home Buyer s and Seller s Guide to Radon

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Radon. In Your Home SAMPLE

Ramon 2.2 Radon-Monitor

Radon Measurement Report

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Locations must be selected where the detector is not to be disturbed during the measurement period.

Testing for Elevated Radon in Oregon Schools

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Memorandum. Introduction

KWA. Evaluation of the Morrison Bros. Co. Liquid Sensor, Adjustable Level Sensor and Multi-Level Sensor. Final Report

Multnomah Education Service District

Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors

Transcription:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD: < 1 pci/l Page 1 of 6

RADON IN AIR Page 2 of 6 1. Are both of the following EPA publications available at the lab: a. Protocols for Radon and Radon Decay Product Measurements in Homes? (EPA 402-R92-003) N002 b. Indoor Radon and Radon Decay Product Measurement Device Protocols? (EPA 402-R92-004) N003 2. Does the facility monitor Radon levels in air for a minimum of 48 continuous hours, process the collective data and interpret the result N004 for the client (rather than merely distributing devices)? 3. Is a written standard operating procedure (SOP) available? (Duplication of the protocols will not suffice.) N005 a. Does the analyst follow the manufacturer s instructions, the US EPA protocols and the lab s SOP? N072 4. Is a written quality assurance project plan (QAPP) appropriate to each device available? N006 5. Does the data collection log include: a. Date and time of deployment? N007 b. Date and time of removal? N008 c. Condition of the devices? N009 d. Attainment of closed building conditions? N010 e. Exact location of device (i.e., building, room and sampling position) within the property being monitored? N011 f. Serial number, model number, and manufacturer of the detector? N012 g. Unique identifier of client and client s address (if different from testing location)? N013 h. Condition of crawl space vents? N014 6. Are monitoring devices deployed and retrieved by trained employees of the radon laboratory? N015 7. When monitoring devices are set out and picked up by different persons, is this noted in the record? N016 8. Is a qualifying statement used if the lab does not control the monitoring process (i.e., placed and/or retrieved by persons other N017

than trained lab personnel)? 9. Are all devices deployed for 48 continuous hours if the N018 measurement is used for remedial action or to determine the need for further measurements? 10. Is the technical director of the laboratory aware of the device s Lower Limit of Detection (LLD), and has the background level been N019 determined? (Short term ~0.2 pci/l; Long term ~0.3 pci/l) EQUIPMENT 1. Are electret ion chamber radon detectors (ECs) of the type recommended for the exposure period and concentration? N117 (Short term (ES) 2-7 days; Long term (EL) 1-12 months) 2. Is an instruction sheet provided to the client? N118 3. Is a shipping container provided to the client with a label for returning the detector(s)? 4. If the analysis is not performed in a temperature-controlled room, is the temperature before and after analysis recorded? a. Are pre- and post-analysis temperatures within 10 degrees F? b. Is the manufacturer s recommended temperature correction factor applied? 5. Are pre- and post-sampling voltages recorded? a. Is a record of the pre- and post-sampling volatages maintained? b. Is the post-sampling voltage above 150 volts? 6. Are devices recharged when minimum voltage is reached? (See manufacturer s instructions.) QUALITY CONTROL 1. Is a reference electret used to check the reader weekly or with each use? a. Is there a record of the weekly or each use reference Page 3 of 6 N119 N120 N120A N120B N121 N121A N121B N121C N123 N124

check? 2. Is the meter zeroed according to the manufacturer s instructions? N125 a. Is there a record of the meter zeroing check? N126 Laboratory Control Detectors 3. Has the background gamma exposure been checked prior to the N128 use of the detectors? a. Have at least 10 or 5% of the electrets, whichever is smaller, been checked for voltage drift? b. Is a background gamma exposure record available? 4. Have the detectors been kept in a low Radon environment with the caps on for a period of time similar to that used in the homes? 5. Is the voltage drop for short term electrets (ES) less than 1 volt per week over three weeks? 6. Is the voltage drop for long term electrets (EL) less than 1 volt per month over three months? N129 N130 N131 N132 N133 Duplicate Collocated Detectors 1. Are duplicate detectors installed in homes at the rate of 10% of deployed detectors each month or 50, whichever is smaller? N135 2. Are the duplicates systematically distributed throughout the workload? N136 3. Are the duplicates handled identically to the samples? N137 4. Are the duplicates not identified as such to the analyzing N138 laboratory (i.e., submitted blindly)? 5. Is the precision of the duplicate data from radon levels measured at 4 pci/l or above within 10% Relative Standard Deviation (RSD: for N139 a long-term series of duplicate measurements), or 14% Relative Percent Difference (RPD: for a single pair of duplicates)? 6. Are the data from duplicates available (e.g., control charts)? N140 7. Are the acceptance limits for duplicates determined? N141 Page 4 of 6 Spiked Samples

1. Are spiked samples with known radon exposures submitted at the rate of 3 per 100 measurements, with a minimum of 3 per year and a N145 maximum of 6 per month? 2. Are spiked samples labeled as routine samples? N146 3. Are the results of spiked samples kept as part of the record (e.g., control charts)? 4. If the acceptance limits are exceeded, is the source of the problem determined? SYSTEM CALIBRATION 1. Has either the manufacturer or the user calibrated the complete system (detectors and readers) in a Radon Chamber yearly? 2. Has a minimum of 10 detectors been exposed at a minimum of 3 different concentrations? 3. Is the exposure period sufficient to allow the detector to achieve equilibrium with the chamber atmosphere? 4. If the manufacturer is performing the calibration, does the lab utilize the correct calibration coefficient? RECORD KEEPING N147 N147A N149 N150 N151 N151A 1. Are the following record(s) kept for 5 years by the measurement organization: a. A copy of the final report including measurement results and the statement outlining any recommendations concerning N237 retesting or mitigation provided to the building occupant or agent? b. The address of the building monitored including zip code? N238 c. The exact locations of all deployed measurement devices? (Examples: room sketches, detailed written description) N239 d. Exact start and stop dates and times of the measurement period required for analysis? N240 e. A description of the device used including the device identification number and serial number, if applicable? N241 f. A description of the condition of any permanent vents? N242 g. The name of the service organization used for calibrations and the certificates of calibration? N243 Page 5 of 6

h. The name of the individual who conducted the test along with their associated training records? N244 i. A description of any variations from or uncertainties about standard measurement procedures, closed building conditions, or other factors that may affect the measurement N245 result? j. A description of any non-interference controls and copies of signed non-interference agreements? N246 k. A record of any quality control measurements associated with the test? N247 l. The written authorization from the client enabling the lab to report results to a third party (if applicable)? N254 REPORTING 1. Does the lab report the result with an uncertainty or error factor, if one is provided by the manufacturer? N249 2. Does the report contain the advisory of 10 NYCRR 16.130 for properties tested within New York State having measured radon gas N257 levels >20 pci/l or 0.1 working level? 3. For labs within NYS, does the laboratory report all of its radon monitoring data to the State according to 10 NYCRR 16.130? N258 4. Are results calculated correctly? N262 5. Are field duplicate readings, if available, reported in an acceptable manner? (See EPA 402R92-003). N259 When any radon screening or long term testing result exceeds 20 pci/l or 0.1 working level as defined in section 16.2(a)(145), the customer, if a resident of New York State, is advised to contact the New York State Department of Health, Bureau of Environmental Radiation Protection, for further technical advice and assistance. New York State Radon Office Phone (518) 402-7556 Toll Free (800) 458-1158 Website: http://www.health.state.ny.us/environmental/radiological/radon Page 6 of 6