Packaged Solutions. Basic Packages

Unvented Water Heating. Zircon

SMART HOT WATER SOLUTIONS PRODUCT RANGE

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Combined electric boiler and domestic hot water store

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

Amptec. Electric flow boiler

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Multipoint Technical Data

Cistern-fed water heating

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

HI-MAX STORE Installation, operation and maintenance manual

Electromax. Combined electric boiler and domestic hot water store

Handy Dri / Hair Drier

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Hotflo. Unvented point of use hot water

Sirius FS. Working towards a cleaner future

ADVANCE ECB ELECTRIC COMBINATION BOILER

Unvented water heating

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Megaflo eco Unvented hot water cylinders

Unvented water heating

Ventilation Product range ADVANCE ECO 4 ECO 2

HI-MAX INSTANT Indirect HIU First Fix Rail / Stand-off Kit Fitting Instructions

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

Installation & Technical Guide. Domestic & Commercial.

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Where gas is not an option,

MEGAFLO HE Iss 1

heat interface units A BOILER WITHOUT A FLAME

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Combi Eco Elite Range. User s Guide and Important Warranty Information

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

ADVANCE ELECTRIC THERMAL STORE

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Instructions for Use Installation and Servicing

Megaflo eco. Unvented hot water cylinders

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

The Ultimate Solution for Electric Central Heating. Fusion. Comet

2015 PRODUCT RANGE GUIDE

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Hand Hygiene. September 2015 EV Instantaneous Handwash

the electric heating company ELECTRIC BOILER HANDBOOK

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Herz York Direct Heat Interface Unit

Alpha FlowSmart 25 and 50

SEALED THERMAL STORE

Frequently Asked Questions

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

User s Operation Instructions & Important Warranty Information

Unvented Direct & Indirect Hot Water Cylinders (400L L)

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

FASTflo. Working towards a cleaner future

Avanta 12v - 15v - 18v - 24v - 30v

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Stainless Steel Unvented Cylinders

MEGAFLO Eco SystemReady Unvented Indirect Hot Water Cylinders

Baxi Maxflow Combi WM

Baxi Maxflow Combi FS

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Water Heating Systems

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

A homeowner s guide to the Baxi Neta-tec Combi

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Unvented Direct & Indirect Hot Water Cylinders

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

SOLAR HEATING SYSTEMS

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Installation and Servicing Instructions. Alpha FlowSmart

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

Solar thermal domestic hot water system

Broag Pressurisation equipment

Pressurisation units & expansion vessels

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Alpha CombiMax 350 and 600

Electromax Combined Electric Flow Boiler and Direct Unvented Hot Water Cylinder Installation and Servicing Instructions

Transcription:

Stored Water District Heating Interface Units Heat Interface Units

Why choose Elson Elson are a Heatrae Sadia company, the UK s leading manufacturer of hot water solutions utilising thermal store technology and vented and unvented cylinders. Being part of one of Europe s leading heating groups, Elson offers you first class customer service; reliable specification advice on product selection and system type, installation support and guidance on how to get the optimum performance from your system. Today s construction industry demands fast and efficient solutions, coupled with minimum time, labour and waste on site. Our packages increase on-site efficiency and substantially reduce waste, benefiting from off-site fabrication techniques. As an addition to the pre-plumbed system package, Elson can organise a trained engineer to visit site at the appropriate time to perform any necessary adjustments, tests and inspection to ensure that the equipment is in full working order and operating to the specified design requirements. heateam Elson products are supported by heateam. With us on your side, you can be sure that your customers are in the very best hands. Totally committed to quality and safety, heateam is open 7 days a week, for 363 days a year. Opening Times: Monday-Friday 8am-6pm, weekends and Bank Holidays* 8.30am-2pm. Simply call 0844 871 1535 or visit our website at www.heateam.co.uk *Excluding Christmas Day and New Year s Day. Technical design team Engineer site visits All system components included All Elson products are hydraulically and electrically tested in the factory Consistently achieved quality, integrity and system performance One supplier better logistics and a reduction in site deliveries Shorter installation times on-site Predictable completion dates Cost certainty Reduced risk of theft or damage Compact and aesthetically pleasing design solutions Reduces health and safety risks on-site Less packaging, less waste Less on-site storage space required 2 YEAR GUARANTEE MADE IN THE UK ISO 9001:2008 FM 01862 ISO 14001:2004 EMS 556355 BS OHSAS 18001:2007 OHS 515891 To download product files, drawings and technical information please visit www.elsonhotwater.co.uk 2 www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk

Stored Water District Heating Interface Units Heat Interface Units Individual hot water and heating comfort from a community heating system could not be more simple. Due to pressure on specifiers and consultants to deliver more sustainable heating schemes, individual gas boilers installed within flats, maisonettes and apartments are now often replaced with a single central boiler or district heating system. Apart from the benefit to the environment, the benefits of using the single boiler house are wide ranging. Flue and condensate siting, gas safety issues and annual servicing become a thing of the past (as far as the individual properties are concerned). The choice for the specifier and designer is whether the hot water is stored or instantaneous. It is fair to say that both systems have their benefits, however, the stored solution reduces the need for higher boiler power and significantly reduces the size of the distribution network and pumps. All of these associated costs can be saved without compromising hot water performance. Whatever the choice, designing and installing a system to meet the requirements is often time consuming and complex. Once designed, the finished system has to be installed into many properties. This can become difficult to manage from a quality and consistency point of view. To assist in this process Elson has developed a heat interface unit which brings together all of the required components, this makes choice of location flexible and installation simple. As every unit is identical, consistency and quality is guaranteed. Time on site is reduced significantly and with that, the associated costs. This highly compact unit is wall mounted, can be sited almost anywhere and can be supplied with or without the optional case. As everything is contained in the unit and fully tested before dispatch, there will be a significant reduction of skills needed on site. The Elson CB Heat Interface Unit can be installed with almost any hot water cylinder or thermal store. This provides the user with controllable heat and hot water comfort. www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk 3

Stored Water District Heating Interface Units Product features 12 1 3 4 8 7 2 13 14 5 11 15 9 16 10 14 6 4 www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk

CB-1Z CB-1Z-DC CB-2Z CB-2Z-DC FEATURES The CB-1Z is designed for small apartments, where one space heating zone is required. The unit is ideal for installations where the 230V on/off district valve is located outside the apartment (i.e. in the corridor) or it is already fitted in the dwelling, such as for a retrofit. The CB-1Z-DC is designed for small apartments, where one heating zone is required. The unit comes complete with an integral 230V on/off pressure independent balancing and control valve and strainer. This negates the need for the installer to fit separate district heating zone valves, flow regulation and autobalancing valve. The CB-2Z is designed for larger apartments, where a two space heating zones are required. The unit is ideal for installations where the 230V on/off district valve is located outside the apartment (i.e. in the corridor) or it is already fitted in the dwelling, such as for a retrofit. The CB-2Z-DC is designed for larger apartments, where a two space heating zones are required. The unit comes complete with an integral 230V on/off pressure independent balancing and control valve and strainer. This negates the need for the installer to fit separate district heating zone, flow regulation, and auto-balancing valves to each apartment. 1 Wiring Centre Pre-wired and Earth Tested 2 Pre-charged 8 litre expansion vessel Easy access from the front 3 15mm central heating safety valve with tundish 4 5 3 8" Automatic air vent complete with shut off valve and anti-suction valve Brazed stainless steel heat exchanger with EPP moulded insulation cover for reduced thermal losses 6 Unit drain valves (primary and secondary circuits) 7 Central heating pump and isolation valves 8 Hot water system primary 2 port zone valve 9 Heating zone 1 apartment heating 2 port control valve 10 Heat meter stool piece (¾" x 110mm) 11 ½" BSP heat meter sensing point Flat-face district heating connections 12 First fix rail to suit single and double heating zone valve variants complete with 3/4" isolation valves 13 ¾" BSP male Y strainer 4 4 14 15 16 Test points to measure pressure drop across district control valve if fitted for flow verification DN15 compact pressure independent balancing and control valve complete with 230V on/off actuator Heating zone 2 apartment heating 2 port control valve ACCESSORIES 4 4 4 4 4 4 First fix rail assembly one heating zone 4 4 First fix rail assembly two heating zones 4 4 Programmable room thermostat with DHW time control Programmable room thermostat for second heating zone 2 4 4 Outer casing www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk 5

Specification 1 2 3 4 5 6 7 Maximum operating conditions Maximum primary operating temperature 90ºC Maximum ambient temperature 50ºC Maximum primary operating pressure* 10 bar g Maximum secondary operating pressure (apartment central heating safety valve set pressure) 3 bar g Maximum chloride content in water Primary and Secondary 150 mg/l *Higher pressures available on request Design conditions Primary (district) flow temperature 85ºC Primary (district) return temperature 65ºC Secondary (apartment) flow temperature 80ºC Secondary (apartment) return temperature 60ºC Primary flow rate 575 litres / hour Primary pressure drop 30 kpa Heat exchanger rating 13.40 kw Electrical 230V / 50Hz / 1ph 3 amp fused supply M H G F E D C B A Guarantee On-site service support including parts and labour for 24 months from date of purchase. Terms and conditions apply. Flushing bypass arrangement It is recommended that a flushing bypass arrangement is installed to allow the CB Heat Interface Unit to be isolated from the district heating system during flushing and filling of the distribution network. K J I L District heating piping arrangement Where the CB unit is fitted with a two port on/off district heating control valve all index branches within the distribution pipework should be fitted with a reduced flow bypass valve to ensure water flows through these pipes at all times. It is recommended that this valve is sized and set to pass 5% of the design flow rate for each branch. Two channel programmer with built-in room thermostat The CB Heat Interface Unit can be supplied with a Danfoss TP9000 2 channel controller. The controller has an in built room thermostat to control one heating zone, but also comes with a separate room thermostat should you wish to install the controller in a cupboard or the kitchen for example. On systems where there are two heating zones, an additional programmable room thermostat, such as the TP5000 is required. Treatment of water in the central heating system All re-circulatory water systems will be subject to corrosion unless they are flushed and an appropriate water treatment is applied. To prevent this, follow the guidelines given in BS 7593 Treatment of Water in Domestic Hot Water Central Heating Systems and the treatment manufacturer s instructions. Treatment must involve the use of a proprietary cleanser and an inhibitor. Failure to flush and add inhibitor to the system will invalidate the appliance warranty. It is important to check the inhibitor concentration after installation, system modification and at every service in accordance with the inhibitor manufacturer s instructions. (Test kits are available from inhibitor stockists.) Earth bonding Ensure the installation is earth bonded in accordance with BS EN 7671:2008. To download product files, drawings and technical information please visit www.elsonhotwater.co.uk 1. Community (district) heating flow ¾" BSP male 2. Community (district) heating return ¾" BSP male 3. HWS primary return connection ¾" BSP male 4. Common central heating return connection ¾" BSP male 5. Central heating flow (zone 1) connection ¾" BSP male 6. Central heating flow (zone 2) connection ¾" BSP male 7. HWS primary flow connection ¾" BSP male CB-1Z / CB-1Z-DC CB-2Z / CB-2Z-DC A 222 222 B 282 282 C 343 343 D 401 401 E 477 477 F 533 G 583 583 H 620 620 I 745 745 J 795 795 K 805 805 L 845 845 M 220 220 Min. clearance (top) 150mm 150mm Min. clearance (sides) 25mm 25mm First fix rail 2.5kg 2.8kg Dry weight 25kg / 26kg 26kg / 27kg 6 www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk

Package options Elson can also provide a truly complete solution, where together with the CB Heat Interface Unit we can offer Megaflo Eco unvented or Coral Aquanox thermal store indirect options. Both of these options, can incorporate a choice of system interface components required to meet virtually any requirement. The Elson website is populated with in-depth technical detail, manuals and drawings to make selection and specification easy. However, nothing can replace the personal help and assistance from one of our highly experienced team. With a click or call, we are here to help. Visit www.elsonhotwater.co.uk to learn more. CB package with Megaflo Eco indirect unvented cylinder CB package with Coral Aquanox indirect hot water thermal store Options Hot Water Thermal Store Unvented Cylinder Type ti120 ti150 ti175 ti210 70i 125i 145i 170i 210i 250i 300i Horstmann E30 run back timer, factory fitted and pre-wired 4 4 4 Horstmann E30 run back timer, supplied loose 4 4 4 Pre-plumbed cold water control pack 1 with drain valve 4 4 4 Pre-plumbed cold water control pack 2 with balanced cold supply and drain valve 4 4 4 Pre-plumbed cold water control pack 3 with balanced cold supply and drain valve 4 4 4 Primary pipework pack with pre-plumbed pressure gauge, auto air vent with isolation valve, anti suction valve and filling loop. Linking pipework from pack to HIU to be provided by installer 4 4 4 Auto fill feed and expansion tank with ball valve arrangement Manual fill feed and expansion tank with water level indicator, flexible fill pipe with isolation valve www.elsonhotwater.co.uk 0844 335 8819 specifier@elsonhotwater.co.uk 7

For over 90 years Elson have been manufacturing water heating products and providing hot water solutions for the UK market. This wealth of experience and industry expertise ensures that Elson will have the right product and solution for any application. Whether for a new-build development, a refurbishment project or simply replacing an existing unit, Elson has the answers. Zircon Elson s Zircon unvented cylinder range is constructed from strong and lightweight Duplex stainless steel to allow ease of handling on-site, whilst offering exceptional corrosion resistance particularly in aggressive water areas, compared with some forms of stainless steel and glass-lined steel. Providing your customers hot water needs, the Zircon cylinder range ensures the best possible performance powerful mains pressure showering and fast filling baths, whilst delivering reliability and efficiency. Coral Aquanox thermal store The Coral Aquanox range of thermal stores is available with either direct electric or indirect formats. The Coral Aquanox thermal store is ideal for providing mains pressure hot water in dwellings where the safety discharge from an unvented cylinder is difficult to accommodate, for example, in flats and apartments. With the addition of a manual fill kit, it becomes a standalone unit. Complete heating and hot water packages Elson specialises in offering tailor-made heating packages. Each package is modular designed to ensure that it matches your exact requirements. Following an initial consultation the package is designed and then manufactured. Using any Heatrae Sadia product, including electric boilers, thermal store units, unvented cylinders and Baxi or Remeha gas boilers. Elson manufactures pre-plumbed packages, built on a frame, incorporating all the system interface components required for your application, e.g. programmer, zone controls and pump. All packages are site-ready, for quick and easy installation. Elsy & Gibbons, Fifers Lane, Norwich, Norfolk NR6 6XB T: 0844 335 8819 F: 0844 871 1528 E: info@elsonhotwater.co.uk W: www.elsonhotwater.co.uk BJN 203296-020 The pace of product development is such that we reserve the right to change product specifications without notice. We do, however, strive to ensure that all information in this catalogue is accurate at the time of publication. Part no. 93 900 030 Issue 2