MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Similar documents
MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

USER MANUAL UN-200V / UN-200VH

Audi-Larm Audible Alarm

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Water Distiller Service Manual

568X, 587X, 588X Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

HEATING AND AIR CONDITIONING

Owner s Guide and Installation Manual

INSTALLATION. Glass Panel Doors (select models) CAUTION

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

CONSTANT SUCTION UNIT

CBT Bowl & wrap replacement

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

Owner s Guide and Installation Manual

INSTALLATION & OPERATING INSTRUCTIONS

A/C COMPRESSOR OIL CHECKING

Installation Instructions Part No , Part No Part No

Installation. Leveling

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

TECHNICAL INSTRUCTIONS

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Heat Exchanger Block Replacement Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

HD Kompakt Service Manual

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

ED4000 & ED5000 SERIES EXIT DEVICES with M61 ALARM OPTION and ED40AK & ED50AK ALARM RETROFIT KIT

INSTALLATION INSTRUCTIONS

IPT Series 2P5X, 2S5X, 2S5XC & 3S5X Pumps Refer to pump manual for General Operating and Safety Instructions.

IN-TANK TECHNOLOGY REPAIR GUIDANCE: MOTOR REPLACEMENT FOR BX3000 & BX5000

ROTARY TUMBLER LORTONE INSTRUCTIONS AND PARTS LIST. Model 3-1.5B. Model 45C. Model 33B Cyrus Way Mukilteo, WA (425)

Table of Contents. Ceiling Bracket Installation

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

*****Important Read First*****

Heater Upgrade Instructions

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Preparation. Downrod. Maintenance.

STAINLESS STEEL UNITS

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Heat Exchanger Tube Change Procedure

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Vertical Inline Models

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Pentz EF5 Installation Guide

F AN-ASPIRATED RADIATION SHIELD

INSTRUCTION AND REPAIR MANUAL

TECHNICAL INSTRUCTIONS

SuperKlean Washdown Products

INSTALLATION INSTRUCTIONS

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Eldex Column Heater. Operator s Manual

CHAMPION PUMP OWNER S MANUAL

EcoVision Door Manual

Marley Ultra Quiet Fan

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

MEMOIRSS ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS (4.8L) VITREOUS CHINA ONE-PIECE TOILET(4.8L) K-3451T-*/K-3453T-*

WAILEA OWNER S MANUAL

USER MANUAL. PEDESTAL FAN (16 Inch)

MODEL 4246 MIXER-GRINDER

User s Manual and Operating Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Group 7 COOLING SYSTEM CONTENTS

TECHNICAL INSTRUCTIONS

SuperKlean Washdown Products

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

BMW E36 Thermostat Removal And Coolant Flush

HW-17 Record Cleaning Machine Setup and Instruction Manual

COUTURE ECO-LITE VITREOUS CHINA REVERSE TRAP TOILETS

Transcription:

MODEL SK2750 COMPRESSOR SERVICE KIT For use on 2750 Series Compressors WARNING: Unplug the compressor before beginning disassembly. CAUTION: Improper assembly or use of damaged parts may lead to premature failure. To avoid frequent repairs follow the recommended assembly procedures. This kit includes the following parts: 625645 Head Screw (8) 623632 O-Ring Connector Tube (4) 623178 Head Gasket (2) 623144 O-Ring (Sleeve) (2) 618119 Cylinder Sleeve (2) 625776 Screw (2) 662310 Piston Cup 662054 Valve Flapper (4) 617312 Valve Restraint (4) 625071 Flapper Screw (4) NOTE: Before you begin, read these instructions thoroughly and assemble the necessary tools. You will need: 1/4 Hex Socket attachment for torque wrench Flat blade screwdriver attachment for torque wrench Torx T-27 attachment for torque wrench Torx T-25 attachment for torque wrench (for head screws). 5/32 allen wrench for eccentric set screw Clean Cloths Part No.642642A 0805

DISASSEMBLY NOTE: To avoid confusion, service one side of the compressor at a time. 1st Stage Repair (lead end of compressor) STEP 1. Clean loose dirt from the outside of the compressor. STEP 2. Loosen the 8 head screws (1) and remove the compressor heads (2) and connector tubes (3) as one piece. Pull the 2 heads apart and remove the 2 connector tubes. Carefully remove the valve plates (5) from the bottom of the head. Caution: Place capacitor off to side leaving it connected to lead wires. STEP 3. Remove the head gasket O-rings (4) and discard them. STEP 4. Turn the valve plates over. Remove the valve plate O-rings (6) and discard. Remove the 2 o-rings from the end of the connector tube (3) and replace. Use a blunt object to aid this replacement. Any scratch or dent in this area can cause an air leak. Figure 1 1 3 2 4 5 6 1

STEP 5. Remove the exhaust valve flapper and valve keeper from the bottom of the valve plate (discard all). Clean the bottom of the plate with a clean, soft cloth. Install the new exhaust valve flapper and restraint. NOTE: Torque flapper screw to 12 inchpounds. STEP 6. Install the new O-ring, seating it firmly into the groove with your finger or blunt object. (See Fig. #2). Figure 2 STEP 7. Remove the intake valve flapper and valve keeper from the top of the valve plate (discard all). Clean the top of the plate with a clean, soft cloth. Install the new intake valve flapper and restraint. NOTE: Torque flapper screw to 12 inchpounds. Figure 3 STEP 8. Install the new head gasket, seating it firmly into the groove with your finger or blunt object. (See Fig. #3). Set aside. STEP 9. Remove the fan guard by unscrewing the 2 screws holding it to the housing. See figure 4. STEP 10. Remove the fan by releasing the pressure from the clip holding it to the shaft. Note position of fan for reassembly. (Hub facing in? Hub facing out?) Figure 4 2

Access Hole Eccentric Set Screw Access Hole STEP 9. Insert the 5/32 allen wrench into the access hole on the side ot the compressor housing. Loosen the set screw 1/4 turn. Rotate connecting rod to top dead center (180 ) and slide the connecting rod/eccentric assembly off the shaft and through the opening in the housing. Figure 5 Eccentric Set Screw STEP 10. Secure the rod assembly in a fixture. Remove the sleeve (1 - discard) from the connecting rod. Remove the screw (2 - discard ) from the cup retainer (3-retain for reassembly). Remove the piston cup (4 - discard) and wipe debris from the top of the connecting rod and retainer with a clean damp cloth. 1 2 3 STEP 11. Carefully place new sleeve (1) over connecting rod top. Place new cup (4) in center of connecting rod top. Do not damage the cup. Place retainer (3) on top of cup (counterbore up). Drive new retainer screw to 60 lbs. Carefully push sleeve up forming the cup. Stop pushing the cylinder sleeve up when the piston cup is positioned midway inside the sleeve. 4 Figure 6 3

STEP 12. Rotate the rotor shaft so that flat faces up (12:00) Position piston cup at bottom dead center of cylinder sleeve. STEP 13. Slide the connecting rod assembly onto the shaft until it meets.04 spacer. Align the eccentric setscrew with the flat of the shaft. Rotate the eccentric and shaft 90 degrees so the set screw is visable through the access hole in the housing. Seat the allen wrench into the set screw but DO NOT TIGHTEN. STEP 14. Temporarily place the valve plate asembly on the compressor housing so the lip of the cylinder sleeve fits into the O-ring on the bottom of the valve plate assembly. Position the valve plate so the mounting holes line up with the threaded holes in the housing. Temporarily insert two head screws into the mounting holes to secure the valve plate assembly. NOTE: The purpose of this procedure is to correctly position the connecting rod assembly on the the motor shaft before tighting the set screw. STEP 15. Use a torque wrench to tighten the eccentric setscrew to 80 inchpounds. Remove the valve assembly and head screws. STEP 16. Align the flat on the fan with the flat on the motor shaft and slide the fan back onto the motor shaft, making sure you position the fan clip in the same orientation as it was before you removed it. Incorrect orientation of the fan will not provide adequate cooling of the compressor. CHECK OPERATION Figure 7 Hold the sleeve down against the housing with one hand, and slowly rotate the fan with the other hand to ensure all components are lined up properly. As the piston travels up and down it will also rock from side to side. This is a feature of the WOB- L Piston. REPEAT FOR SIDE TWO 4

REASSEMBLY STEP 1. With the sleeves firmly seated on the housing, replace the valve plates in same manner as they were. (See Fig. #8). Make sure the top edge of the sleeve locates in the O-ring groove in the bottom of the valve plate. CAUTION: Make sure gasket is not twisted when seated in groove. Figure 8 O-Ring Groove STEP 2. Place heads on the valve plates. Torque the head screws to 40 inch lbs. in a criss-cross pattern. Caution Numbers indicate tightening sequence Power Leads 4 6 2 8 5 3 7 1 Head Assembly To avoid property damage or personal injury, always try rotating the fan by HAND prior to connecting the unit to the power source. Check for suction at the air inlet port by placing your finger over the port as you turn the fan. You should feel a slight suction with each rotation of the fan. If you don t feel suction, or if you feel or hear a thump as you turn the fan, DO NOT CONNECT THE UNIT TO A POWER SOURCE; review the assembly procedure for possible error. STEP 3. Reassemble the fan guards to the compressor. Tighten screws to 10 inch lbs. 5

Notes 6

1419 Illinois Avenue Sheboygan, Wisconsin 53082 USA (920) 457-4831 www.rtpumps.com