Expansion Modules & Accessories

Similar documents
Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Honeywell Combination Fire & Burglary Control Panel

Security & Communications INTRUSION AND ALARM COMMUNICATIONS

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Model 17A00 Expansion Enclosure

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

P Zone Expandable Hybrid Security System

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

First page of this international document resides under separate cover: 20SEaCOV.ps

Commercial Fire and Burglary Partitioned Security System with Scheduling

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot

VISTA-100 Commercial Fire & Burglary Partitioned System

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev.

VISTA-20HWSE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM

DS7400Xi Addressable Control/ Communicator

&RPPHUFLDO%XUJODU\ ,QVWDOODWLRQDQG6HWXS*XLGH 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3 STAY 1 OFF 6BYPASS 5 TEST 4 MAX 9 CHIME 7 INSTANT OFF 2 AWAY

VISTA-100. COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING. INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Installation and Setup Guide

VISTA-128FB. Installation and Setup Guide. Commercial Fire & Burglary Partitioned Security System with Scheduling

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

9,67$39,67$3&1 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH K /01 1 OFF 4 MAX OFF 7 INSTANT 9 CHIME READY

&RPPHU LDO)LUHDQG%XUJODU\

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

4286/4500 Voice Module Set up and Troubleshooting

&RPPHUFLDO)LUHDQG%XUJODU\

AL600ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99

Installation and Set-Up Guide

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

SP40S-D. Kingfisher Company, inc. Features: Description:

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

)$&3 ,QVWDOODWLRQDQG6HW8S*XLGH K5305-5V1 8/02 OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 BYPASS MAX INSTANT READY ARMED READY

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

EVO192 v3.0 Fire and Burglary What s New

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

System Introduction. 1.1 Specifications S E C T I O N 1

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

AL800ULADA. NAC Power Extender. Installation Guide

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

The OmniPro II EN50131 and PD6662 Compliant Controller

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

V2 1/13 Rev C

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

The Omni LTe EN50131 and PD6662 Compliant Controller

VISTA-10SE. Security System. Installation Instructions Installation Instructions Installation Instructions

ECC-50/100C. Emergency Command Center

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

FireNET Plus Wiring Instructions

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Vista-128FB System Design Sheet

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

WIRELESS CONTROLS & DETECTORS

Security Systems. Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN. Installation and Set-Up Guide

Booster Power Supply Manual

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

30.45 Electric Release PDRP-2001

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

The Omni IIe EN50131 and PD6662 Compliant Controller

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

If you want to. grow your business expand your. expectations.

MODEL B2 INSTALLATION MANUAL

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

ADEMCO LYNXR Series Security Systems

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

Installation Instructions

June 10, 2002 DF C S2424

RELEASE DEVICE CONTROLS

System Programming Guide

KT-100 Door Controller

Transcription:

HONEYWELL SECURITY & COMMUNICATIONS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and help end-users take full advantage of their security system features. Products include power supplies, switchers, sensors and a full line of devices featuring Honeywell s patented V-Plex polling loop technology, which literally redefines price and performance on a simple pair of wires. THIS SECTION INCLUDES: ADEMCO V-Plex Power Supplies Omni Expansion Modules & Accessories 129

Expansion Modules & Accessories ADEMCO EXPANSION ECP-ISO ECP Isolator Helps to maintain the operation of near-side isolated equipment such as fire keypads and communicators in the event of shorts or grounds on the extended ECP bus. Compatibility: - VISTA-128FBP - VISTA-250FBP - FA1670C - FA1700C 4101SN V-Plex Addressable Relay Module One Form C SPDT relay One class B/style B EOLRsupervised aux. input zone Operating power and communication with control panels via the addressable V-Plex polling loop Electronics mounted in a small plastic case with tamper-protected cover Suitable for residential and commercial burglary and fire installations 2.13" W x 3.25" H x 1" D 4190SN V-Plex Two-Zone Expander Closed-circuit devices with or without EOLR supervision Open-circuit devices with EOLR supervision Fast-response (10 millisecond) devices 2.13" W x 3.25" H x 1" D 4193SN V-Plex Two-Zone Expander Makes any hardwired contact device V-Plex ready Built-in serial number for addressing One supervised zone and one unsupervised zone UL listed fire (when mounted inside a UL listed cabinet) and burglary applications Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. 4204 Relay Module Four on-board programmable relays Applications include sounder, strobe lights or interface to other equipment to provide added convenience Easily wires to the control and fits comfortably inside the cabinet 4204CF Supervised Notification Appliance Module Adds up to two Class B (style Y) supervised notification outputs to compatible ADEMCO panels Applications such as sounders and strobe lights to provide added convenience Easily wires to the control and fits comfortably inside the cabinet Has a built-in cover tamper switch to detect and report the removal of its cover to the panel 4208SN Remote Eight-Zone Interface Module Remote V-Plex zone interface module Supports serial number application 4208SNF Universal Class A and Class B Expander Module Provides up to six Class B supervised zones using external 10k EOL resistors and two Class A supervised loops using built-in 10k EOL resistors Powered from addressable loop or DC power supply Serial number addressing via DIP switch 130 www.honeywell.com/security/hsc

Expansion Modules & Accessories ADEMCO EXPANSION 4208U V-Plex Universal Eight-Zone Expander Remote eight-point module (for fire or burglary) Supports both DIP switch and serial number applications Please see page 119 for more information on V-Plex. 4209U Four-Zone V-Plex Group Zoning Module Combines two-wire smoke detectors from an area of protected premises into group zones Supports both DIP switch and serial number applications Can be attached remotely or at the panel All loops are EOLR supervised (2K, supplied) Provides power and super-vision for twowire industry standard smoke detectors 4219 Wired Zone Expander Adds up to eight end-of-line supervised zones Connection made to the control s console wires Comfortably fits inside the controls cabinet Supported on VISTA-15/20 series control panels 4229 Wired Zone Expander/Relay Board Provides eight end-of-line supervised zones Two on-board programmable relays Connection made to the control s console wires Supported on VISTA-15/20 series control panels 4293SN V-Plex Serial Number Interface Module Single-zone expander (unsupervised) Makes any hardwired contact device V-Plex ready Built-in serial number for addressing UL Listed commercial and household burglary applications 4297 V-Plex Polling Loop Extender Module Isolates and protects different areas of protection Extends loop distance Separate DC input, no loop current drain -VSI V-Plex Short Isolator Detects and isolates polling loop branches with complete or resistive shorts Can be used to isolate burglary devices from fire devices LED indicator reduces troubleshooting time and maintenance costs 4.14" L x 2.56" W x 0.87" D Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. Please see page 119 for more information on V-Plex. 131

Expansion Modules & Accessories ADEMCO ACCESSORIES VA8200 Panel Linking Module The VA8200 Panel Linking Module allows multiple control panels to be networked together and controlled from any keypad in the system, letting you control multiple zones, partitions or buildings from one location. Links panels to control multiple systems, and buildings from one central location Up to eight systems can be linked together 6.44" W x 4.5" H x 1.25" D Compatible with VISTA-128BP, VISTA-128FBP, VISTA-250BP,VISTA-250FBP 4286 VISTA Interactive Phone Module This module for any VISTA security system provides remote control access from any touch-tone phone. Customers can conveniently arm, disarm and check their security system status or conduct home automation functions from any location. Performs most keypad functions from a touch-tone phone locally or remotely System can be called to check the system status and arm/disarm security system remotely Operates relays or X-10 receivers on select VISTA panels to control lights and appliances Large vocabulary of words for voice descriptors 6.44" W x 1.25" H x 4.25" D Compatible with all VISTA panels 4500 Thermostat Module Works with the 4286 to expand the home control feature of the VISTA Security System to include temperature control (ESAVR-KT) 6.12" W x 2.88" H x 1.25" D 659EN Line Fault Monitor Monitors phone-line voltage Operates on 6 or 12VDC Form C relay Momentary or maintain relay closure 2.5" W x 6" H x 1.5" D 4100SM Serial Interface Module Interface for printer for VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP and VISTA-250FBP Direct wire download interface for VISTA-40, VISTA-50P, VISTA-128BP, VISTA-128FBP, VISTA-250BP and VISTA-250FBP 4" W x 2.75" H x 0.75" D 5140DLM Backup Dialer Provides a secondary supervised dialer output to commercial fire panels: VISTA-128FBP, VISTA-250FBP and VISTA-32FB Voltage is 12VDC 5mA inactive current 15mA active current NFPA-72 compliant Listings: UL/ULC Listed to UL365, UL464, UL609, UL864,UL1610, UL1635, CAN/ULC-S303, CAN/ULC-S304, CAN/ULC-S525, CAN/ULC-S527 132 www.honeywell.com/security/hsc

Expansion Modules & Accessories ADEMCO ACCESSORIES 1361X10 X10 Plug-In Transformer Provides 16.5VAC Provides the most powerful yet simple solution for controlling lights and appliances through X10 compatible AC line carrier Provides both power to the panel and direct signaling capability to the existing AC wires Simple to wire Only requires one AC outlet AD12612 Power Supply Provides six or 12VDC 1.2 Amps continuous output to power devices Transformer purchased separately Factory preset at 13.6VDC, with jumper set to 12VDC Battery: Supports a standard 4 AH gel cell battery Transformer required: 6V operation 12VAC, 20VA (Model 1322/TF3) 12V operation 16.5VAC, 40VA (Model 1361) Fuse: 3 Amp fast blow fuse (Model FP1166) Board dimensions: 4" W x 2" H x 1.75" D AD25624 Power Supply Provides 12 or 24VDC 2.5 Amps continuous output to power devices Transformer purchased separately Battery: Supports a standard 4 AH gel cell battery Transformer required: XF30 is recommended and can be used for either 12 or 24VDC operation (1451-24, in red cabinet) Fuse: 6 Amp (Part #N9544) 5 Amp (Part #90-9) Board dimensions: 6.5" W x 2" H x 1.562" D AVS Audio Verification System Two-way voice communication during the event of an alarm allows central station operators to talk directly to end-users and vice-versa ECP four-wire support on AVS control and AVST voice station Enhanced sound quality on AVST (87 db) AVS control mounts directly inside VISTA cabinet Compatible with GSMV for two-way voice use over GSM Compatible with VISTA-15P, VISTA-20P and VISTA-21iP for ECP connections 133

Expansion Modules & Accessories OMNI OMNI EXPANSION OMNIEXP8 Hardwired Expansion Module Eight zone wired expander (16 zones with unique zone doubling options) Snaps directly to control board for easy installation Cost effective system expansion 3.5" W x 1.9" H XL4705 Relay Expansion Module Relay expansion module allows five dry form C (SPDT) relay outputs to be added to the OMNI408, OMNI624EU and OMNI848EU Up to four of these modules can be used with the OMNI624EU and OMNI848EU 6" W x 2.75" H 134 www.honeywell.com/security/hsc

In business, like everything else, sometimes we take things for granted. But the problem with taking things for granted is that if you re not careful, those things can quickly disappear. To ensure a profitable future, you need to support the Security Industry Alarm Coalition (SIAC). From Washington to Massachusetts, this non-profit organization works with law enforcement and alarm associations, fighting against onerous alarm ordinances. Ordinances that if passed, could seriously jeopardize the profitability of your business. You might say, It doesn t matter if SIAC is helping dealers miles and miles from my business. But if you neglect the problem until it reaches your door, it might be too late. Support SIAC today at www.siacinc.org 135

Notes 136 www.honeywell.com/security/hsc