Alarm Controller Fire and CO

Similar documents
Model: Ei450. Instruction Manual

Fire / CO Alarm Interface

RadioLINK Alarm Base. Instructions. Model: Ei168RC

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

RF Modules for Battery Powered Smoke & Heat Alarms Ei600 Series

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Deaf & Hearing Impaired RadioLINK Alarm System

RELAY BASES & COVERS

RELAY BASES & COVERS

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

Battery Powered Smoke Alarms Ei650 Series

Battery Powered Smoke & Heat Alarms Ei600 Series

Ei160e Series 230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. User Section

Ei3024 / 3016 / 3014 Alarms Instruction Manual

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

U S E R M A N U A L UBH1RF HEAT ALARM

230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. Contact Us

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

230V~ MULTI-SENSOR FIRE ALARM. with Rechargeable Lithium Cell Back-up. P/N B18397 Rev2. Ei2110e Series. Instruction Manual.

B15527-R3-3105RF-UC-ENG 14/10/08 9:35 AM Page 1. Radio Wireless Interconnect SMOKE ALARM

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

230V~ SMOKE & HEAT ALARMS. with Alkaline Battery Backup. Instruction Manual. Contact Us

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Wireless Base Remote Test and Hush

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

IN-OUT Thermometer with Cable Free Sensor and Clock

Battery Powered Smoke & Heat Alarms Ei600 Series Instructions

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

RadioLINK MAINS POWERED CARBON MONOXIDE ALARM WITH RECHARGEABLE LITHIUM CELL BACK-UP. Model Ei262

C-Stat 17-ZW User Instructions

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

User Manual THR842DUK Wireless Digital Thermostat

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Honeywell Temperature & Humidity Sensor with LCD

FEATURES AND SPECIFICATIONS

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Wireless Interlink Smoke Alarm + 10 Year Life

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Digital Thermometer with Ice Alert and Clock

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

hc3 OWNER S MANUAL OMHC3US2016/07E

External Wireless Sounder

SPECTRA 1727 USER S GUIDE

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

9000P Wireless Alarm Owner s Manual

USER MANUAL 10 YEAR LIFE SMOKE ALARM

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

Property Name & Address [ Property Name ] - [ Property Address ]

Mains Powered Carbon Monoxide Alarm with rechargeable lithium cell back-up

Digiplex LED Keypads User s Manual

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH AND ARROW- HEAD WITHIN THE

GT-1D. Residential/Tenant Station OPERATION MANUAL

Ei3028 / 3018 Alarms Instruction Manual

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Wireless Rain Gauge with Indoor Temperature

Keep this guide in a safe place. Contents

Contents. Glossary

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

IMPORTANT SAFETY INFORMATION:

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Heat Sensor. Owner s Manual

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

RF2352A, HC2351AC (Discontinued), HC2352AC

Zigbee Smoke Sensor PSG03

WBS-616 User Manual. Wi-Safe Remote Warning Handset Part of the Wi-Safe Home Safety System

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

COMBINED STROBE & VIBRATING PAD

CS027 User Instructions

Digiplex LED Keypads. User s Manual

USER MANUAL & MAINTENANCE GUIDE OG OO

KFP-CF Series Operation Manual

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

MAINS POWERED CARBON MONOXIDE ALARMS WITH RECHARGEABLE LITHIUM CELL BACK-UP. Model Ei261ENRC Model Ei261DENRC WITH DIGITAL DISPLAY

LOW VOLTAGE PANEL SMOKE & HEAT ALARMS

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Multi-Channel Indoor & Outdoor Thermometer with Cable Free Sensor & Radio Controlled Clock

Transcription:

Alarm Controller Fire and CO Model: Ei450 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Smoke Alarm. The leaflet should be regarded as part of the product. If you are just installing the unit, the leaftet must be given to the householder. The leaflet is to be given to any subsequent user.

Contents 1. Overview... 2. Installation... 3. House Coding... 4. Operation... 5. System Diagnostics... 6. Five Year Guarantee... 7. Troubleshooting the RF link... 8. Limitations of Radio Communications... 9. Technical Specification... 10. Getting your Ei450 Serviced.... 25 2 Page 3 6 8 13 17 21 22 23 24

1. Overview Congratulations on purchasing the Ei450 single button alarm controller for RadioLINK Fire and Carbon Monoxide (CO) Alarm systems. The Ei450 tests and controls fire, CO and hybrid (Fire + CO) RadioLINK Alarm systems. Function Remote Test Remote Locate Remote Silence Fire Indicator CO Indicator EOL Indicator Memory Memory ID Description All the Alarms can be tested from a centralised location This will silence all the Alarms in the system except the one sensing Fire or CO This will silence all the Alarms in the system Indicates a that a Fire Alarm has been activated Indicates a that a CO Alarm has been activated Indicates that the battery has reached its end of life (EOL) Indicates if a Fire or CO Alarm has been previously activated Identifies the Alarm that has previously been activated Some older revisions of our RadioLINK modules do not support the Memory ID function. Check this page on our website for a complete and accurate list of products that support this function. 3

Fire Indicator Low Battery Indicator CO Indicator Light Segments (4) Test / Control Button Segment Colour Activity Function enabled RF signal activity Function complete 4

Wireless Smoke Alarm System Wireless Smoke & Carbon Monoxide Alarm System RF Smoke Alarm RF Smoke Alarm RF CO Alarm RF Smoke Alarm RF Smoke Alarm Alarm Controller RF Smoke Alarm Alarm Controller Works with Model No. - Alarms Ei160RC & Ei2110 Series Smoke Alarms Ei262 Mains Carbon Monoxide Alarms Ei605 & Ei650 Series Smoke Alarms Ei208 Battery Powered Carbon Monoxide Alarms Ei170RF Comment The Alarms must be fitted on Ei168RC RadioLINK bases The Ei262 has built-in RadioLINK technology The Alarms must be fitted with the appropriate Ei605 series RadioLINK module The Alarms must be fitted with Ei200MRF RadioLINK modules Deaf Alarm Strobe and Vibration Pad For most up to date works with list check webpage www.eielectronics.com/articles/ei450-memory-id-products.html 5

Install the Ei450 mounting plate at an accessible point on the wall 1.4M +/- 200mm from floor level. If it intended for a disabled person to operate the controller, an alternative mounting location should be considered. Also consider security and chose a location where it will not be accidently or otherwise operated. Turn on the system by sliding the switch to the on position. MODE ON POWER OFF H.CODE 6

Check the power up sequence All RadioLINK devices, Smoke Alarms, CO Alarms, control switches, etc. in the system must be put into house code. For instructions on how to house code the Ei450 controller, see the House Code section of this manual. For instructions on house coding the other devices please refer to their individual manuals. Repeat this procedure for all Alarms and RadioLINK devices in the system. MODE ON POWER OFF H.CODE 7

It is essential to House Code the Ei450 i-controller to all the other RadioLINK Alarms and devices in the system to ensure they will not communicate with nearby systems. Failure to house code the system may also result in a system malfunction. Press and hold the House Code switch on the back of the controller until all segments light up blue, then release. The segments will flash rapidly for a moment on entering house code (H CODE). MODE ON POWER OFF H.CODE House code all other RadioLINK Alarms and accessories in the system. Consult the instruction manuals on how to house code these devices. 8

Return to the Ei450 i-controller and check that all 4 segments (ring) are flashing blue. The number of flashes should equal the number of RadioLINK devices in the system. A system with 3 smoke alarms, one CO alarm and the i-controller will result in five blue flashes. The flash pattern will repeat every 5 to 10 seconds while the i-controller remains in house code. If it fails to flash the correct number of times, then consult the Troubleshooting the RF link section of this instruction manual. Now, walk around the house to verify that all the other RadioLINK Alarms and RadioLINK devices are giving the correct amount of flashes. If any of these fail to flash the correct number of times, then consult the Troubleshooting the RF link section of this instruction manual. To complete the commissioning, the system must exit house code mode. 9

The units will automatically exit house code after 30 minutes. Once coded the system will not communicate with any other RadioLINK devices outside the house coded group. To manually exit house code press the house code button on the back of the Ei450 switch. When all the segments light up blue, release the button. This unit will then send a Cancel signal to all the other RadioLINK devices to exit House code. After a short period the blue light will turn off and the system will return to standby mode (normal). Depending on the number of Alarms and RadioLINK devices in the system this period could vary from 5 to 20 Seconds. MODE ON POWER OFF H.CODE If you choose to make the switch tamper proof remove the pip (plastic post) using a pliers or similar tool. MODE ON POW 10

Slide the Ei450 onto the mounting base on the wall. Check that the RadioLINK system is working by pressing the button on the Ei450 i-controller until the TEST segment lights blue. This indicates a RadioLINK test signal has been activated. All the Alarms in the system will sound for a short period and then stop. If the test fails go to Troubleshooting the RF link section. 11

Sometimes in order to resolve an RF communication issue, e.g. Alarms had to be relocated, it may necessary to reset and house code the system again. To reset the Ei450 i-controller press and hold the house code switch. All segments will flash blue briefly and then go solid. After 5 seconds approx. the segments will start flashing blue. At this point release the house code switch. The Ei450 has now been reset. To reset the other Alarms and accessories in the system consult the appropriate instruction manuals. MODE ON POWER OFF H.CODE 12

Frequent testing of the system is advised to ensure its continued and safe operation. Guidelines and best practices for testing are as follows: 1. After the system is installed. 2. Once weekly thereafter. 3. After prolonged absence from the dwelling (.e.g. after holiday period). 4. After repair or servicing of any of the systems elements or household electrical works. Press the button on the Ei450 i-controller until the TEST segment lights up blue. Release the button. All Alarms in the system will sound for a short period and then stop. If the MEMORY segment lights up blue instead of the TEST it means that a CO or Fire alarm was previously activated. See the fire and CO memory sections and report the incident to the appropriate authorities. 13

If there is a fire, immediately evacuate the premises and telephone the fire brigade. If the source of the alarm is not obvious go to the Ei450 i-controller and check to see which indicator is illuminated, Fire or CO. premises. Telephone the appropriate authorities to report the incident. If the fire indicator is lighting and there is no obvious fire, press the button. The LOCATE segment will change from red to blue. After a 10 to 40 seconds period, all the Alarms in the system will stop sounding except the source Alarm(s). 14

If you are satisfied there is no fire but the Smoke/Heat Alarm is still continuing to alarm you may now silence the system. Wait until the SILENCE segment is flashing red and then press the button. The SILENCE segment will turn blue, the Alarm(s) will stop sounding and all segments on the controller will flash green momentarily to indicate that the Controller is back in standby. The Alarms in the system will be silenced for the next 10 minutes. The fire memory feature enables the identification of a fire Alarm that has previously been activated, e.g. one that false alarmed when the house was not occupied. 1. After the Alarm deactivates, the Fire indicator will flash alternatively with the MEMORY segment (red) for 2 minutes and then stop. 2. To recall the memory press the button, the MEMORY segment will light blue and the source alarm will sound briefly and stop several times. 3. To reactivate the memory feature press and hold the button briefly while the FIRE Icon is still flashing. This reactivation can be repeated indefinitely. If the button is not pressed the memory recall will timeout in 10 seconds. 15

4. When the FIRE icon stops flashing, the memory recall is complete, the Alarm will stop sounding and the Alarm controller will return to standby with all segments extinguished. 5. The memory is now erased and pressing the button again will perform a normal test. The CO memory feature enables the identification of a CO Alarm that has previously been activated, e.g. a CO incident while the house was not occupied. 1. After the Alarm deactivates, the CO indicator will flash alternatively with the MEMORY segment (red) for 2 minutes and then stop. For the next 24h hours they will flash alternatively once a minute. 2. To recall the memory press the button, the MEMORY segment will light blue and the source alarm will sound briefly and stop. Depending on the number of alarms in the system the source alarm will sound and stop a number of times. 3. To reactivate the memory feature press and hold the button briefly while the CO Icon is still flashing. This reactivation can be repeated indefinitely as long as the icon is still flashing. If the button is not pressed the memory recall will timeout in 10 seconds. 4. When CO icon stops flashing, the memory recall is complete, the Alarm will stop sounding and the Alarm controller will return to standby with all segments extinguished. 5. The memory is now erased and pressing the button again will perform a normal test. 16

The system diagnostic features are intended to assist professional installation and maintenance personal to install, commission and maintain the RadioLINK fire and control systems utilising the Ei450 i-controller. These features are not intended for the home owner / tenant and should only be used by personnel described above. The alarm identification test only works with some RadioLINK Alarms. To check the current list of Alarms supported or for additional maintenance and diagnostic information please go to this webpage Alternatively use your smart phone to capture this QR code and download the page immediately. Remove the Ei450 controller from its cradle. If the unit has been tamper proofed you will need to release the latch with a screwdriver. 17

With the Ei450 in your hand press and hold the button. Walk around the house and verify that each Alarm is sounding. When testing is complete release the button and replace the controller in its cradle. If the test fails go to Troubleshooting the RF link section. A special system diagnostic mode will facilitate the following special tests. 1. Two minute Long Test. This is an alternative to the walk round test described previously. 2. Identify any Alarm that been previously activated. The procedure is used to manually exit the diagnostic. If there has been 2 minutes of inactivity the alarm controller will automatically exit the diagnostic mode. MODE ON POWER OFF H.CODE To enter the system diagnostic mode use a small screwdriver to press and release the MODE button on the back of the unit. All segments will flash green to indicate that the diagnostic mode has been activated. 18

On entering the system diagnostic mode the TEST segment will flash green inviting you to press the button. When you press the button the segment will turn blue and all the Alarms in the system will sound for 2 minutes. This will allow you to walk around the house and verify that each individual Alarm is sounding. The test will automatically cease after 2 minutes or if the button is pressed again. If an alarm memory has been set the TEST and MEMORY segments will flash green alternatively after entering the system diagnostics mode. While the MEMORY segment is illuminated press the button until the MEMORY segment goes blue. 19

This will then locate the Alarm that was previously active and cause it to sound for a number of seconds (depending on the number of RadioLINK devices in the system). Pressing the button again will cause it to sound again. This allows you to walk around the house until you have found the active Alarm. All segments will flash green. The i-controller will automatically exit the alarm identification test after 2 minutes or if the system diagnostic button is pressed again. Press and hold the MODE switch on the back of the unit. The green segments will light up. When these segments start flashing, release the button. The memory identification is now cleared. To erase the alarm identification memory press and hold the MODE button on the back of the alarm for about 6 seconds until all the segments flash green. The memory identification has now been erased. MODE ON POWER OFF H.CODE 20

that are due to faulty materials or workmanship. This guarantee excludes replaceable batteries. This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused. This guarantee excludes incidental and consequential damage. This guarantee does not cover costs associated with the removal and/or installation of units. If the product should become defective within the guarantee period, it may be returned with proof of purchase, carefully packaged, and with the problem clearly stated to the place of purchase or phone one of these numbers for advice. UK: 0870 758 4001 ROI: +353 61 471277 We shall at our discretion repair or replace the faulty unit. 21

If, when checking the RadioLINK interconnection, some of the Alarms do not respond to the Ei450 remote control test, then: (i) Ensure the Ei450 controller has been activated correctly. Check that the power on procedure operates as described in the installation section. (ii) Repeat House Code procedure (see section 2). (iii) Relocate the Ei450 controller and/or rotate/relocate the RadioLINK Alarms. There are a number of reasons why the RadioLINK signals may not reach all the Alarms in your system (see section 6 on Limitations of Radio Frequency Signals ). Try rotating the units or relocating the units (e.g. move them away from metal surfaces or wiring) as this can significantly improve signal reception. Rotating and/or relocating the units may move them out of the range of existing units even though they may have already been House Coded correctly in the system. It is therefore important to check that all Alarms are communicating in their final installed positions. If units are rotated and/or relocated, we recommend that all units are returned to the factory settings (see the respective use and care instructions).then House Code all units again in their final positions. The RadioLINK interconnection should then be checked again. 22

Ei Electronics radio communication systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range (required by regulatory bodies) there are some limitations to be considered: (i) Radio equipment, such as the Ei450 controller, should be tested regularly - at least weekly. This is to determine whether there are sources of interference preventing communication. The radio paths may be disrupted by moving furniture or renovations, and so regular testing will help identify these and other faults, so that they can be rectified (see Section 5). (ii) Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the House Coding. The Ei450 i-controller has been tested to EN 300 220-1 V1.3.1 (2000-09) in accordance with the requirements of EN 300 220V1.1.1 (2000-09). These tests are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause interference to radio and/or television reception. However, there is no guarantee that interference will not occur in a particular installation. If the Ei450 controller does cause such interference, it can be verified by turning it on and off. 23

The user is encouraged to eliminate the interference by one or more of the following measures: (i) Re-orientate or re-locate the unit. (ii) Increase the distance between the Ei450 and the device being affected. (iii) Consult the supplier or an experienced radio/television technician. Supply Voltage Powered for life Lithium battery RF Frequency 868.499Mhz Temp Range 0 o C to 40 o C (Cat 3) Humidity 15% - 95% (Non Condensing) Receiver Category Cat 2 RF Performance EN 300-220 EMC Performance EN 301-489 Range 150 meters in free space Number of RF interconnected Alarms 12 per house code group* *Note: For applications with greater than 12 Alarms please contact technical support for guidance. 24

If your Ei450 fails to work after you have carefully read all the instructions and checked that the unit has been installed correctly contact Customer Assistance at the nearest address given at the end of this leaflet. If it needs to be returned for repair or replacement, slide the switch to the off position, place it in a padded box and send it to Customer Assistance and Information at the nearest address given on the unit or in this leaflet. MODE ON POWER OFF H.CODE State the nature of the fault, where the controller was purchased and the date of purchase. 25

The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream. Proper disposal will prevent possible harm to the environment or to human health. When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner. For more details on collection and proper disposal, please contact your local government office or the retailer where you purchased this product. 0889 26

27

Maesbury Road, Oswestry, Shropshire SY10 8NN, U.K. Telephone: 0870 7584000 Shannon Industrial Estate, Shannon, Co. Clare, Ireland. Telephone: +353 (0)61 471277 Ei Electronics 2012