Fire / CO Alarm Interface

Similar documents
Model: Ei450. Instruction Manual

Alarm Controller Fire and CO

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

RF Modules for Battery Powered Smoke & Heat Alarms Ei600 Series

RELAY BASES & COVERS

RadioLINK Alarm Base. Instructions. Model: Ei168RC

RELAY BASES & COVERS

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Deaf & Hearing Impaired RadioLINK Alarm System

Ei160e Series 230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. User Section

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. Contact Us

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

230V~ SMOKE & HEAT ALARMS. with Alkaline Battery Backup. Instruction Manual. Contact Us

230V~ MULTI-SENSOR FIRE ALARM. with Rechargeable Lithium Cell Back-up. P/N B18397 Rev2. Ei2110e Series. Instruction Manual.

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Battery Powered Smoke & Heat Alarms Ei600 Series

Ei3024 / 3016 / 3014 Alarms Instruction Manual

Battery Powered Smoke Alarms Ei650 Series

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Battery Powered Smoke & Heat Alarms Ei600 Series Instructions

Ei3028 / 3018 Alarms Instruction Manual

RadioLINK MAINS POWERED CARBON MONOXIDE ALARM WITH RECHARGEABLE LITHIUM CELL BACK-UP. Model Ei262

Ei414 Fire/CO Alarm Interface. Are you missing the connection?

WM3000 WIRELESS MODULES

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

V-MUL-033(A0) RADIOLINK BASE

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Mains Powered Carbon Monoxide Alarm with rechargeable lithium cell back-up

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

MAINS POWERED CARBON MONOXIDE ALARMS WITH RECHARGEABLE LITHIUM CELL BACK-UP. Model Ei261ENRC Model Ei261DENRC WITH DIGITAL DISPLAY

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

U S E R M A N U A L UBH1RF HEAT ALARM

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

Model 17A00 Expansion Enclosure

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Product Selector. Fire & Carbon Monoxide Detection. Quality Service Innovation. ISSUE 8

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Wireless Base Remote Test and Hush

Honeywell Temperature & Humidity Sensor with LCD

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

LOW VOLTAGE PANEL SMOKE & HEAT ALARMS

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH AND ARROW- HEAD WITHIN THE

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

SMARTWALK DEMENTIA WANDERING SYSTEM

INSTALLATION GUIDE XTLN-WIFI PANEL

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

Universal Fan and Light Remote Control

Atomic Projection Alarm Clock

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

Sidekick II Receiver Model # SK2-SS 418MHz

GT-1D. Residential/Tenant Station OPERATION MANUAL

"Pegaso" wireless alarm system

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Security System. User Guide for the LED Command Center

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

PERMACONN PM1030 Includes DI300. Installation Manual

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Projection Alarm Clock

KM300 Carbon Monoxide Detection System Installation Manual

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

User Guide. for the Beacon ProActTM 200 System

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

APC BC300 Series 40kW 208/450/480V User Guide

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Please Keep This Manual For Future Reference REV.01

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

TFD-1 Installation & User s Guide

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

MTRA-FSP Level Control Relay. Installation & Operation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Operation and Maintenance Manual

1126 Series Ceiling Mount PIR Motion Detector

Watchguard WGAP864 User Manual

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

C-Stat 17-ZW User Instructions

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Transcription:

Fire / CO Alarm Interface Model: Ei414 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Fire / CO Alarm Interface. The booklet should be regarded as part of the product. If you are just installing the unit, the booklet must be given to the householder. The booklet is to be given to any subsequent user.

Contents 1. Introduction & Connection Diagrams... 3 2. Typical Installation Examples... 8 3. Installation... 11 4. House Coding... 18 5. Testing... 22 6. Service Relay... 23 7. User Information... 24 8. Troubleshooting the RadioLINK... 26 9. Technical Specification... 27 10. Service & Guarantee... 28 11. Contact Us... 32 2 Page

1. Introduction The Ei414 Fire / CO Alarm Interface can be used to connect Ei Electronics RadioLINK Alarm Systems to suitable other Systems such as Fire Panels, Telecare Systems, Auto Diallers, Security Systems etc. The Ei414 has 3 output relays for Fire, CO & Service that can be triggered by an Ei Electronics RF Alarm System. These relays can be directly connected to the other Systems or alternatively can be used to trigger one of the other Systems RF transmitters. A RadioLINK system consists of Ei Electronics RadioLINK Smoke, Heat and CO Alarms along with RadioLINK accessory devices that are interconnected using the Ei Electronics proprietary RF protocol system. The Ei414 must be House Coded to the other RadioLINK devices in the system. Alarm Code LED s How to remove Cover service OFF ON TEST Key Switch On Off Test Fire / CO Alarm Interface Fire / CO Alarm Interface RadioLink LED Power LED 3 open screws then insert screwdriver into the notch to remove cover

Wireless Smoke Alarm System Wireless Smoke & Carbon Monoxide Alarm System RF Smoke Alarm RF Smoke Alarm RF CO Alarm RF Smoke Alarm RF Smoke Alarm Alarm Controller Alarm Interface RF Smoke Alarm Alarm Controller Alarm Interface Works with Model No. - Alarms Ei140RC, Ei160e & Ei2110e Series Alarms Ei262 Mains Carbon Monoxide Alarms Ei605 & Ei650 Series Smoke Alarms Ei208W powered for life Carbon Monoxide Alarms Ei170RF & other RadioLINK devices Comment The Ei140RC Series Alarms must be fitted on Ei168RC RadioLINK bases. The Ei160e & Ei2110e Series Alarms must be fitted with an Ei100MRF RadioLINK + Module. The Ei262 has built-in RadioLINK technology Alarms must be fitted with the correct Ei605 & Ei650 series RadioLINK module The Alarms must be fitted with Ei200MRF RadioLINK modules Contact us or visit our website for details Due to our continuous improvements policy, product performance and features are being frequently updated - See Contact Us section 4

Fire / CO Alarm Controller Hardwired Output Connection Diagram External Panel (Fire / Telecare etc.) Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Signal Input from Ei Alarm System service 11-30VDC OFF ON TEST 230VAC Fire / CO Alarm Interface Ei414 For connection to External Panel see Manufacturers instructions 5

Fire / CO Alarm Controller Wireless (RF) Connection Output Diagram External RF Panel (Fire / Telecare etc.) RF Transmitter Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Signal Input from Ei Alarm System RF Transmitter ON service OFF TEST 11-30VDC RF Transmitter Fire / CO Alarm Interface Ei414 230VAC For connection to External Panel & RF Transmitter see Manufacturers instructions 6

Fire / CO Alarm Controller Input Connection Diagram External Device (Strobe etc.) Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Fire Signal Output External Fire Panel service OFF ON TEST Fire / CO Alarm Interface 230VAC External Device (sprinkler flow valve) Ei414 For connection to External Devices see Manufacturers instructions 7

Fire / CO Alarm Controller 2. Typical Installation Examples RadioLINK Mains Powered Alarm System External Panel (Fire / Telecare etc.) Ei146RC Smoke Alarm with Ei168RC RadioLINK Base Ei164e Heat Alarm fitted with Ei100MRF RadioLINK + Module Ei450 Alarm Controller service OFF ON TEST Fire / CO Alarm Interface Ei414 In the event of a fire, the Ei140RC / Ei160e / Ei2110e will detect Smoke / Heat and either the Ei100MRF or the Ei168RC base will transmit an RF fire signal to the Ei414. The Ei414 will then trigger the external panel. N.B. The Ei450 Alarm Controller MUST be used to test the RadioLINK Alarm System (at least 1 x Ei168RC must be fitted - see User Information section). 8

RadioLINK Battery Powered Alarm System External RF Panel (Fire / Telecare etc.) Fire / CO Alarm Controller Ei650RF Smoke Alarm Ei603TYCRF Heat Alarm Ei450 Alarm Controller ON service OFF TEST In the event of a fire, the Ei650RF / Ei603TYCRF will detect Smoke / Heat and transmit an RF fire signal to the Ei414. The Ei414 will then trigger the RF transmitter and alert the external panel. Fire / CO Alarm Interface RF Transmitter Ei414 9

ON service OFF TEST Fire / CO Alarm Controller RadioLINK / Hard Wired Hybrid System fire External RF Panel (Fire / Telecare etc.) CO RF Transmitters Fire / CO Alarm Interface Ei414 Ei650RF Smoke Alarm Ei146RC Smoke Alarm with Ei168RC RadioLINK Base Ei208WRF Carbon Monoxide Alarm Ei164e Heat Alarm Ei450 Alarm Controller In the event of a fire / CO event, the relevant Smoke / Heat / CO Alarm will transmit an RF signal to the Ei414. The Ei414 will then trigger the relevant RF transmitter and alert the external panel. 10

3. Installation Screw Fixings Dip Switch (default) 1 2 1 2 ON Fire Relay Service Relay CO Relay C NO NC C NO NC C NO NC Antenna 0 I Screw Fixings RadioLINK LED Battery Backup Switch 11

Screw Fixings ON L N E + SW SW + Voltage Input 12-24V Volt Free Contacts DC Power In 11-30V AC Mains Input 230V Trigger inputs to send fire signal to the RF Alarm system. These inputs will also activate fire relay (see Dip Switch operation) Power inputs 0 I Battery Backup Switch Power LED Note: This MUST be switched to the ON position upon installation (see Installation section) (N.B. The Lithium battery is not replaceable) Screw Fixings 12

Mounting and Wiring AC Mains Wiring (230V) Warning: To prevent injury, this apparatus must be securely attached to the wall in accordance with the installation instructions. 1. Remove the cover (see page 3). Mount the Ei414 in a suitable location on a wall using the fixings provided, away from any objects that may block the RF signal (i.e away from metal surfaces). The Ei414 may also be mounted on a 35mm Din Rail. Mounting clips for this application must be purchased seperately. 2. Disconnect the AC mains supply from the circuit that is going to be used. The disconnect device (i.e mains switch) must be an all pole circuit breaker, with a contact gap of minimum 3mm and disconnects both poles simultaneously. 3. The house wiring must be connected to the terminal block on the unit: L: Live connect to the house wires coloured brown or marked L N: Neutral connect to the house wires coloured blue or marked N E: Earth connect to yellow/green wires or marked E Note: Wiring must be installed in compliance with local regulations and by qualified/competent personnel. 13 L N E + SW SW + Front View: standard wiring from wall mount

(See adjacent diagram for wiring option using surface trunking and knockout segments on the back of the base. Remove segments using a pliers or similar). 4. The green LED will indicate if power has been connected. 5. Ensure the Dip Switch has been set to the correct orientation (see Dip Switch Operation section ). 6. Important: The backup battery switch must be switched on. 7. If using an RF Transmitter connect as advised by the manufacturer to the relevant relay. Use the knockout segments on the back of the base. Remove segments using a pliers or similar (See diagrams on page 15). 8. Fit and secure the top cover with the screws provided. (see page 3). 9. Insert and turn the key supplied to the TEST position to begin system testing (see TESTING section). For a 11-30V DC external source 1. The Ei414 should be located next to DC external source. 2. Locate the auxiliary power output in the DC external source and wire it to the DC Power Input connector on the Ei414. 3. Check that the polarity of the auxiliary power supply has been wired correctly and the power LED is on. 14 Rear View: optional wiring using surface trunking Knockout segments Surface Trunking

4. The trigger input voltage signal is optional and can be triggered by either a 12-24V DC power supply or alternatively from a dry contact signal. 5. Repeat steps 5 to 9 as above. Caution - Alternative Energy Sources (wind, solar, UPS etc.) This product is designed to be connected to a True Sine Wave 230VAC supply. If connecting to a power source that uitilises an inverter, e.g. PV solar panel, the Total Harmonic Distortion (THD) must be less than 5%. If in doubt please check with the manufacturer of the inverter. This also applies to battery powered UPS (Uninterruptible Power Supply) inverters or Light Dimmer Circuits. The Ei414 must not be connected when the house wiring RF Transmitter insulation is being checked with high voltages, i.e. do not use a high voltage insulation tester on the unit. The unit must not be exposed to dripping or splashing. 15 C NO NC C NO NC C NO NC Front View: RF Transmitter installation Knockout segments Rear View: Knockout segments

DIP Switch Operation The Ei414 contains a dip switch which specifies whether the device will work in continuous mode or through a pulsed operation. It is also used to determine whether a hard-wired trigger input will activate the fire relay or not. = Switch 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 ON ON ON ON Relay activates immediately. A hard-wired trigger input will not activate the fire relay Switch 1 & 2 in the 1 & 2 position Relay activates immediately. A hard-wired trigger input will activate the fire relay Switch 1 & 2 in the ON position Relay activates and resets approx 4 seconds later (pulse). A hard-wired trigger input will not activate the fire relay. Switch 1 in the O position & switch 2 in the 2 position Relay activates and resets approx 4 seconds later (pulse). A hard-wired trigger input will activate the fire relay in the same pulsed operation. Switch 1 in the 1 position & switch 2 in the N position Please note: The dip switch only applies to the Fire and CO relays, it does not apply to the Service relay. 16

Keyswitch Orientations OFF OFF OFF ON TEST ON TEST ON TEST The Ei414 will be shipped in the OFF position. When in the OFF position the Ei414 does not respond to any RF signals. In the ON position the Ei414 responds to a fire alarm signal (activates the fire relay) or to a CO alarm signal (activates the CO relay).\ It will not respond to a button test signal. 17 In the TEST position the Ei414 responds to a button test signal (will activate the fire or the CO relay depending on the unit that was button tested). N.B. When testing the system with an Ei450 Alarm Controller, only the fire relay will activate.

4. House Coding It is essential to House Code the Ei414 to all the other RadioLINK Alarms and devices in the system to ensure they will not communicate with nearby systems. Failure to House Code the system may also result in a system malfunction. To House Code: Using a small screwdriver press and hold the House Code button on the bottom of the Ei414 then release. The RadioLINK blue LED will light up and then flash rapidly for a moment. RadioLINK LED Fire / CO Alarm Interface House Code Switch House Code all other RadioLINK Alarms and devices in the system. Consult the instruction manuals on how to House Code the Alarms and devices. It is essential that each individual Alarm / device is put into House Code mode in it s actual location. 18

Return to the Ei414 and check that RadioLINK LED is flashing blue. The number of flashes should equal the number of RadioLINK Alarms and devices in the system. A system with 2 x Smoke Alarms, 1 x CO Alarm, 1 x Alarm Controller and 1 x Ei414 will result in 5 blue flashes. It may take up to 10 minutes before all 5 flashes are seen. The flash pattern will repeat every 5 to 10 seconds while the Ei414 remains in House Code. If it fails to flash the correct number of times, then consult the Troubleshooting section of this instruction manual. RadioLINK LED Fire / CO Alarm Interface House Code Switch Now, walk around the house to verify that all the other RadioLINK Alarms and devices are giving the correct amount of flashes. If any of these fail to flash the correct number of times, then consult the Troubleshooting section of this instruction manual. 19

To complete the commissioning, the system must exit House Code mode. The units will automatically exit House Code after 30 minutes. Once coded the system will not communicate with any other RadioLINK Alarms and devices outside the House Coded group. To manually exit House Code press the House Code button on the Ei414. When the RadioLINK LED lights up blue, release the button. This unit will then send an exit House Code signal to all the other RadioLINK Alarms and devices to exit House Code. After a short period the blue light will turn off and the system will return to standby mode (normal). Depending on the number of RadioLINK Alarms and devices in the system this period could vary from 5 to 20 seconds. RadioLINK LED Fire / CO Alarm Interface House Code Switch 20

Reset the House Code Sometimes in order to resolve an RF communication issue, e.g. Alarms have to be relocated, it may be necessary to reset and House Code all RadioLINK Alarms and devices in the system again. To reset the Ei414 press and hold the House Code button. The RadioLINK LED will flash blue briefly and then go solid. After 5 seconds approx. the blue LED will start flashing slowly. At this point release the House Code button. The Ei414 has now been reset. To reset the other RadioLINK Alarms and devices in the system consult the appropriate instruction manuals. 21

5. Testing The Ei414 must be tested by the installer upon installation. This test is primarily to ensure the functionality of the entire system i.e. the RadioLINK Alarm System in conjunction with the other manufacturer s system. The TEST mode facilitates the installer to button test each Alarm individually to ensure that the correct communication has taken place between the Ei414 and the other manufacturer s system. The installer must ensure that the user has an Ei450 to test the RadioLINK system. Button testing a mains powered Alarm that is either sitting on an Ei168RC base, or hardwired to this base will lead to unnecessary call outs. Testing the alarm system Insert the key switch and turn to the TEST position. Once in test mode the entire system can be tested. (Relay activation can be confirmed by the flashing of the relevant LED on the front over) 1. Button test each Smoke / Heat Alarm in the system, this will activate the fire relay. Similarily, button test each CO Alarm in the system, this will activate the CO relay. The person responsible for testing the system MUST notify the Alarm Receiving Center (or equivalent) that an Alarm system test is in progress. 2. Using an Ei450 Alarm Controller, press the test button and the Alarms in the system will be tested and sound (It is important to keep the Test button pressed until the Fire relay is activated). Only the fire relay in the Ei414 will activate when testing the system with an Ei450. The CO relay will not activate when tested in this manner. (This is not a full system test - we recommend each Alarm should be button tested for full system verification). 22

6. Service Relay The Ei414 is designed to act upon Service messages transmitted from any Alarm in a RadioLINK system. The Service relay will activate after one of the following events: (this will be indicated by the service LED flashing approx. every 6 secs). 1. Alarm Head Removed When a Smoke/Heat or CO Alarm is removed from its mounting plate (RadioLINK+ devices only). 2. Sensor Fault When there is a fault with a Smoke/Heat/CO Alarm sensor 3. Low Battery When any Smoke/Heat/CO Alarm in a system has a low battery condition When the Ei414 indicates that a Service is required please investigate each Alarm in order to detect the source of the issue. In the instance where an Alarm head has been removed, please replace it. If there is a Sensor Fault or Low Battery indication (Please consult individual Alarm manual for fault indicators) the Alarm must be replaced. Reset Service Relay The Service relay can be reset in two different ways. 1. Identifying and fixing the appropriate issue as indicated in the section above. When the issue is cleared, the Service relay will reset within a max. of 5 hours. 2. Turn the keyswitch to the TEST mode position and then button test any Smoke/Heat/CO Alarm head. This will reset the Service Relay on the Ei414, while setting the Fire/CO relay. When the button is released the Fire/CO relay will be reset. This will also work when pressing the Test button on the Ei450 Alarm Controller. 23

7. User Information Having an Ei414 Fire/CO Alarm Interface installed in conjunction with an other manufacturer s system gives the user additional protection. However it is essential that all Smoke/Heat/CO Alarms are tested weekly. If an Ei168RC RadioLINK Base is installed in the system then the system must be tested using an Ei450 Alarm Controller. Frequent testing of the Fire/CO Alarm system is advised to ensure its continued and safe operation. Guidelines and best practices for testing are as follows: 1. After the system is installed. 2. Once weekly thereafter. 3. After prolonged absence from the dwelling (e.g. after holiday period). 4. After repair or servicing of any of the system s elements or household electrical works. Please refer to the Operation section of the user manual for the Ei450 for more detailed information on testing the RadioLINK system. 24

When the alarm system sounds N.B. If there has been an emergency evacuation procedure put in place by the Alarm Monitoring Centre (or equivalent), please follow those instructions in case of an emergency. If there has not been any specific instructions issued by the Alarm Monitoring Centre, please follow the basic responses in the instance of a fire or CO event. If there is a fire, immediately evacuate the premises and telephone the fire brigade. If a CO Alarm has sounded, open all doors and windows while evacuating the premises. Contact the appropriate authorities to report the incident. The Ei450 Controller is a useful device in that it will indicate whether there is a fire / CO event taking place. The relevant icon on the Ei450 Controller will be flashing. 25

8. Troubleshooting the RadioLINK If, when checking the RadioLINK interconnection, some of the Alarms do not respond, repeat the steps in the Housecode procedure: (i) Ensure the Ei414 has been activated correctly. Check that the power on procedure operates as described in the Installation section. (ii) Relocate the Ei414 and/or rotate/relocate the RadioLINK Alarms. There are a number of reasons why the RadioLINK signals may not reach all the Alarms in your system. Try rotating the Alarms or relocating the Alarms (e.g. move them away from metal surfaces or wiring) as this can significantly improve signal reception. Rotating and/or relocating the Alarms may move them out of the range of existing units even though they may have already been House Coded correctly in the system. It is therefore important to check that all Alarms are communicating in their final installed positions. If Alarms are rotated and/or relocated, we recommend that all Alarms are returned to the factory settings (see the respective use and care instructions). Then House Code all Alarms again in their final positions. The RadioLINK interconnection should then be checked again. 26

9. Technical Specification Power Required: Mains 230VAC or 11-30VDC RF Range: Over 100 meters in free space RF Visual Indicator: Blue light indicates RF activity Power Indicator: Green light indicates mains or DC power connected Alarm Indicator: Red light for Fire (marked) - Red light for CO (marked) Service Indicator: Red light (marked) RF Frequency: 868.499 MHz Mounting: Can be easily mounted onto a wall Guarantee: 5 Years Outputs: Fire Alarm Relay (NO/NC) - CO Alarm Relay (NO/NC) - Service Alarm Relay (NO/NC) Relay Contacts: All relays are rated 250VAC @ 5 Amp. Resistive Normal Operating and Storage Temperature Range: 0 40 o C Normal Operating and Storage Humidity Range: 15% to 95% Relative Humidity non condensing Dimensions: 185mm x 90mm x 37mm - Weight: 300g 27

Five Year Guarantee 10. Service & Guarantee If for any reason the Ei414 needs to be replaced, it must only be disconnected by a qualified engineer or electrician. The device should then be returned for repair or replacement to the nearest address given on the device or in this leaflet. State the nature of the fault, where the unit was purchased and the date of purchase. Ei Electronics guarantees this Fire / CO Alarm Interface for five years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused. This guarantee excludes incidental and consequential damage. If this device should become defective within the guarantee period, it must be returned to Ei Electronics, with proof of purchase, carefully packaged, with the problem clearly stated. We shall at our discretion repair or replace the faulty unit. Do not interfere with the Ei414 or attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user to shock or fire hazards. Caution: The Lithium back-up battery is not replaceable. There is a danger of explosion if the battery is tampered with. This guarantee is in addition to your statutory rights as a consumer. 28

29

The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream. Proper disposal will prevent possible harm to the environment or to human health. When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner. For more details on collection and proper disposal, please contact your local government office or the retailer where you purchased this product. 30

31

11. Contact Us Aico Ltd Mile End Business Park, Maesbury Road, Oswestry, Shropshire SY10 8NN, U.K. Telephone: 01691 664100 www.aico.co.uk Ei Electronics Shannon Industrial Estate, Shannon, Co. Clare, Ireland. Telephone: +353 (0)61 471277 www.eielectronics.com Ei Electronics 2016 P/N B18063 Rev 2