"SAN ACE MC" for Pentium & Pentium 4

Similar documents
MPU Cooler for Pentium 4, SAN ACE MC Michinori Watanabe Toshiki Ogawara Haruhisa Maruyama Masayuki Iijima

"SAN ACE MC" for Pentium *

High Performance Liquid Cooling System SAN ACE MC Liquid Tomoaki Ikeda Toshiki Ogawara Masashi Miyazawa Kouji Ueno

Cooling Fans Contributing to Effective Use of Power

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

The Basics of Package/Device Cooling

Development of a Compact High Efficiency Cooling Device for the PA8000 Processor*

Fike set out to develop a better understanding of the power density trends in data centers around the world.

Heat sinks for electronic cooling applications

(12) United States Patent

Cooling Solutions for High Heat Flux in Dense Packed Servers. Dr. Walter Angelis R&D Manager Aerodynamics Helmut Sebisch Key Account Manager

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Development of Motor Fan Noise Prediction Method in Consideration of Operating Temperature during Engine Idling

Familiarization with the Training System

ZERO Heating Power Vending Machine Hybrid ZERO

The Way We Were and Are Going on Cooling High Power Processors in the Industries

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Power Savings Running LINPACK Liquid Cooled

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

VERSO Air Handling Units

Development of Large Size Hybrid Fan

AC-046 Peltier-Thermoelectric Air Cooler

DeviceNet Mass Flow Controller, the SEC-Z10D Series

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

A new method for preventing air-source heat pumps and refrigerators from frosting

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

Low Noise Type Hydraulically Driven Engine Cooling Fan System

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

A Novel Approach for the Thermal Management. of PC Power Supply

Drying principles and general considerations

VERSO Air Handling Units

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

High-Performance, High-Reliability Gas Heat Pump

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Get The Edge Over The Competition with The Summit

15. Heat Pipes in Electronics (1)

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Incident Summary (II )

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

LG Commercial Air Conditioners. Wide Range Free Combination with Various Indoor Types 24/7.0 18/5.3 12/3.5 9/2.6 7/2.1 5/

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Compact design & easy maintenance

Figure 1: Overview of CO 2 evaporator types

(12) United States Patent (10) Patent No.: US 6,639,797 B2

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

AC-162 Peltier-Thermoelectric Air Cooler

Transcritical CO2 Bottle Cooler Development

Performance Optimization of the Evaporative Condenser Design

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

LUNDBERG EDGE-TRIM GRANULATING SYSTEMS FOR PAPER/ADHESIVE PAPER AND PLASTIC

Optimal work climate with open doors. Industrial air curtains Model IndAC

Development of Induction Heating Device for Corner of Bloom in Continuous Casting machine

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

An Assessment of Radiator Performance

HEAT TRANSFER ANALYSIS OF 1-USER SERVER THROUGH CFD

E-BEAM DRUM TRANSFER: PROCESS TO ELECTRON IRRADIATE A PSA IN THE ABSENCE OF A BACKING.

International Journal on Emerging Technologies 4(2): 42-46(2013) ISSN No. (Print) : ISSN No. (Online) :

Consequences of Landscape Patterns on Flows of Energy, Nutrients, Organisms

NOREN Products. Compact Cabinet Coolers

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

I. C O N T E N T S T A N D A R D S

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

CONSTRUCTION AND OPERATION. 1. Air Conditioning Operation BE-95 BODY ELECTRICAL AIR CONDITIONING

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

Evaporation System: Types and Design Aspects

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Variable far infrared radiation (VFIR) technique for cubic carrot drying

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

USOO A United States Patent (19) 11 Patent Number: 5,794,685 Dean 45 Date of Patent: Aug. 18, 1998

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Ultimate energy saving technology

COOLING OF BIKER S HELMET USING PELTIER MODULE

AIR COOLED CONDENSERS

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

HYDRAULIC CONVEYING OF PLASTIC PELLETS

Gas condensing boiler (wall mounted) TopGas

ADVANCING HVLS technology through controls and energy efficiency

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Fully movable Mass Spectrometer Bench with 6x solidly built lockable casters Integrated noise reduction noise enclosure housing vacuum pumps Specific

Transcription:

1 / 5 SANYO DENKI TECHNICAL REPORT No.11 May-2001 Feature "SAN ACE MC" for Pentium & Pentium 4 Toshiki Ogawara Tomoaki Ikeda Haruhisa Maruyama Masashi Miyazawa 1. Introduction In recent years, PCs and other information equipment have been growing in speed and functionality, resulting in a rising trend in the heating value of the entire equipment. With the size reduction and thinning of the equipment, the heat density of the inside of the equipment continues to rise year by year. Particularly eye-catching is the rate at which microprocessors (MPUs), which are the brain of the computer, are making technical advances. They have never stopped rising in speed, functionality and integration. On the other hand, microprocessors are growing in heating value, with their heat densities rising particularly quickly. Cooling for microprocessors is even more important than ever before, so that demand is high for efficient, high-performance, and silent coolers. To meet these demands, this company has developed and commercialized the "SAN ACE MC" for Pentium, the "SAN ACE MC" for Pentium 4, and the "SAN ACE MC" that can be installed in thin equipment. This paper outlines this series of products and presents its features. 2. Background of development Sanyo Denki has commercialized MPU coolers of the "SAN ACE MC" series, as coolers that cool microprocessors. The line-up consists of the "SAN ACE MC" series designed to cool desktop PCs and the "SAN ACE MC note" series designed mainly to cool notebook PCs and other.(1), (2) thin equipment Ever-faster, ever-higher-functionality microprocessors are rising not only in heating value but in heat density as well at a quick rate. Coolers have come to need some ideas to disperse local heat-up. The "SAN ACE MC" for Pentiumand Pentium 4, which we have now developed, employs a high-density extrusion heat sink. Some models use a copper heat sink to achieve high cooling performance. Now that the age of the Internet has arrived, the size reduction of equipment is even further accelerated. We have then developed and commercialized thin "SAN ACE MC" for Pentium, a cooler that can be contained in 1U servers and other thin equipment and display high cooling performance. 3. Product overview Fig. 1 gives an external view of a typical model of the "SAN ACE MC" for Pentium, a cooler which we have now developed and commercialized. Fig. 2 is an external view of the "SAN ACE MC" series for Pentium 4, and Fig. 3 is an external view of the "SAN ACE MC" series for Pentium. Tables 1, 2, and 3 give the performance specifications of each product.

2 / 5 This product is a cooler that combines a cooling fan with a heat sink in one unit and has been developed specifically for Pentium and Pentium 4 processors. Given below are the features of the product. (1)Fanning structure of Sanyo's original fan and heat sink (2)High cooling performance (3)High cooling performance as assembled on host equipment (4)Low noises (5)High reliability, long service life 3.1 Structure Described below are the structural features of the "SAN ACE MC", which we have developed and commercialized. (1) A fan is installed on the air intake, while a heat sink is on the exhaust. This structure helps increase the fan's life and cooling performance. (2) The frame is so shaped as to allow sufficient air to go through even if an obstruction is placed close to the fan intake. This suppresses the fan's decline in air volume and reduces the impact on cooling performance when the cooler is actually contained in host equipment. Particularly effective in that sense is the thin "SAN ACE MC" for Pentium. In the case of 109X7612S2016, the thermal resistance of a cooler without an obstruction is 0.9K/W, as opposed to about 0.99K/W even when there is an obstruction about 1mm above the fan intake. The impact is thus only about 10%. (3) In some models, the fan contains a temperature-sensing thermistor to detect the fan intake temperature and change the fan rotating speed automatically, thus reducing the noise level of the host equipment during an actual run. 3.2 Performance (1) Heat sink Fig. 4 is an external view of a typical heat sink. The heat sink we used for this project is made of high-density extruded aluminum. As opposed to the conventional aspect ratio (the ratio of fin height to fin-to-fin clearance) of no more than 10, the present product has about 12, which means a narrower fin-to-fin clearance and a larger radiation area. To transfer heat well with the radiator fin, the base has been thickened to promote thermal conductivity. The heat sink for the "SAN ACE MC" for Pentium 4 is given 8 or 9 local slits that cut the fin and base together. These slits increase the cooling performance by about 0.05K/W. This is because a cooling air stream sucked from the fan flows through the heat sink base. The absence of slits in all fins is due to the fact that slitting inhibits heat conduction. A particularly high impact is exercised on cooling performance by slitting the middle fin. Some models have heat sink bases made of highly thermal conductive copper and heat sinks equipped with 0.4mm thick aluminum fins. Cooling performance is even higher than models incorporating extruded heat sinks.

3 / 5 Table 1 Performance specifications for "SAN ACE MC" for Pentium Model No. voltage Operating voltage range current [A] rotating speed [min -1 ] Thermal resistance [K/W] Sound pressure level [db(a)] 4800 0.64 38 109X7612T5S016 0.17 3600 0.71 28 12 7 to 13.8 109X7612S5016 0.17 4800 0.64 38 109X7612H5016 0.1 3900 0.69 31 Note: On the 109X7612T5S016, fan rotating speed varies with the intake temperature between 35 C and 47 C. Table 2Performance specifications for "SAN ACE MC" for Pentium 4 Model No. 109X9612T5S016 voltage Operating voltage range current [A] rotating speed [min -1 ] Thermal resistance [K/W] Sound pressure level [db(a)] 109X9612S5016 12 9 to 13.8 0.23 5000 0.44 40 109X9612A5016 0.13 4400 0.46 36 0.23 5000 3200 0.44 0.52 109X9612H5016 0.1 3600 0.5 31 5000 0.4 42 109X9712T5S016 0.23 3200 0.49 29 12 9 to 13.8 109X9712S5016 0.23 5000 0.4 42 109X9712A5016 0.13 4400 0.42 37 Note: On the 109X9612T5S016 and 109X9712T5S016, fan rotating speed varies with the intake temperature between 35 C and 45 C. Table 3Performance specifications for "SAN ACE MC" for thin Pentium Model No. voltage Operating voltage range current [A] rotating speed [min -1 ] Thermal resistance [K/W] 40 28 Sound pressure level [db(a)] 109X7612S2016 0.17 4800 0.9 38 130 12 7 to 13.8 109X6512A2016 0.07 4800 1.15 35 110 Mass [g] 230 Mass [g] 270 450 Mass [g] (2) Fans The fans contained in the product have been developed specifically for specific models. A particularly imaginative idea used is that for fans to display their maximum performance when contained in host equipment, the venturi is recessed somewhat below the label surface on the boss of the motor, so that even when an obstruction is installed above the fan, a minimum required air passage is secured. In addition, the blade shape, blade-to-spoke distance, blade-to-fin distance, the shape of the spoke base, and other factors have been optimized to increase air volumes and cut noise levels. These considerations have enabled the fans in the "SAN ACE MC" for Pentium 4 to achieve air volumes equal to those of this company's BLDC fans 60mm sq. 25mm thick. (3) Thermal speed controlled fans In some models, the fan is equipped with a temperature-sensing thermistor to detect the intake temperature of the fan. The rotating speed of the fan is varied to cut noise levels during actual operation. Fig. 5 shows the relationship between the intake temperature and rotating speed of a typical fan. Usually, such a microprocessor cooler is used that does not surpass the top limit operating temperature of microprocessors at the top limit of the operating environment of the host equipment.

4 / 5 In the case of the "SAN ACE MC" for Pentium 4, for example, assuming that the heating value of the microprocessor is 50W, the top limit operating temperature of the microprocessor is 67 C, and the top limit inner temperature of the host equipment is 45 C, then the thermal resistance required for the cooler is (67-45)/50=0.44 K/W. The "SAN ACE MC" selected at that time was the 109X9612S5016, with a thermal resistance of 0.44K/W and a noise level of 40dB(A). In an actual operating environment for host equipment, the ambient temperature of the "SAN ACE MC" rarely becomes 45 C. In reality, it is generally around 30 C. Assuming that the internal temperature of the host equipment is 30 C, the performance requirements can be calculated as follows: Thermal resistance is 0.74K/W and a 109X9612H5016 (with a thermal resistance of 0.5K/W) is sufficient to cool the host equipment. In that case, the noise level is about 9dB(A) lower than 109X9612S5016, but considering the worst case scenario of the operating environment for the host equipment raises some concerns over the cooling of microprocessors. Added to the line-up to solve these problems is the "SAN ACE MC", which incorporates the functions of a thermally speed controlled fan. On the 109X9612T5S016, the noise level becomes 28dB(A) because it runs at low speed when the intake temperature of the fan is 35 C. As the intake temperature of the fan rises, the rotating speed of the fan goes up. At 45 C and higher, it runs at high speed, with a noise level of 40dB(A). Thus, this cooler is silent under actual operating conditions, but is capable of cooling microprocessors at the top limit operating conditions of the host equipment. 4. Conclusion We have so far introduced a part of the structure and performance of the newly developed and commercialized "SAN ACE MC" for Pentium, Pentium 4, and thin type "SAN ACE MC" for Pentium. Microprocessors are expected to continue increasing in performance and speed, thus further rising in heating value and heat density. Under these circumstances, there is expected to be demand for coolers that are smaller in size, higher in cooling performance, and lower in noise level. * Pentium in the text is a registered trademark of Intel Corp. References (1) Ogawara et al.: Development of MPU Coolers, "SAN ACE MC" SANYO DENKI Technical Report, No. 1 p9-14 (1996-5). (2) Watanabe et al.: "SAN ACE MC note" SANYO DENKI Technical Report, No. 4 p23-25 (1997-5). Toshiki Ogawara Joined company in 1984 Cooling Systems Division, Design Dept. Worked on development and design of "SAN ACE MC" Haruhisa Maruyama Joined company in 1997 Cooling Systems Division, Design Dept. Worked on development and design of "SAN ACE MC" Tomoaki Ikeda Joined company in 1990

5 / 5 Cooling Systems Division, Design Dept. Worked on development and design of "SAN ACE MC" Masashi Miyazawa Joined company in 1998 Cooling Systems Division, Design Dept. Worked on development and design of "SAN ACE MC"

Fig.1 "SAN ACE MC" for Pentium 1 / 1

Fig.2 "SAN ACE MC" series for Pentium 4 1 / 1

Fig.3 Thin "SAN ACE MC" series for Pentium 1 / 1

Fig. 4 External view of a typical heat sink (109X9612T5S016) 1 / 1

Fig. 5 Relationship between intake temperature and fan rotating speed (109X9612T5S016) 1 / 1

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sanyo Denki: 109X6512A2016