WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

Similar documents
WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

LVSD2 Verge Wash Basin LVS-Series

Express Lavatory System SS-Series

LVSD2 Verge Wash Basin LVS-Series

SS-3N Express Lavatory System SS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Express Lavatory System MG-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LVQD1 Verge with WashBar Technology LVQ-Series

Express Lavatory System MG-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

FL-1H, FL-1L Frequency Lavatory System FL-Series

SS-1N Express Lavatory System SS-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

FL-3H, FL-3L Frequency Lavatory System FL-Series

SS-2N Express Lavatory System SS-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

AV60 Advocate Lavatory System AV-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

Installation Instructions

AV30 Advocate Lavatory System AV-Series

Installation Instructions

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation Instructions

Installation Instructions

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Installation Instructions

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

AV60 Advocate Lavatory System AV-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

AV90 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation Instructions

Installation Instructions OBSOLETE

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Washfountain Application Guide

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

LD-5010 OmniDeck with WashBar 5000 Series

Installation Instructions

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

LA45 DISCONTINUED IMPORTANT!

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

LA90 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

School Solutions Ideabook

Terreon Lav Decks WARNING

Durability within reach

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

PAT BASIN MODEL 9121, 9131, & 9141

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. Section Joint Sealants: Seal fixtures to walls and floors.

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Technical and Dimensional Data. Saf-T Vent SC Plus

Vertical Stack Water Source Heat Pumps

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Willoughby Industries - Security Products

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

C O D E S & A M M E N D M E N T S

Refrigerated Air Dryer

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation & Operation Manual

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

Transcription:

cup ertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Reliable Foot, ir, TouchTime or Infrared ctivations Specifications Size and apacity Semi-circular models accommodate up to 3 users (36" models) or 4 users (5 models) at a time. ircular models accommodate up to 5 users (36" models) or 8 users (5 models) at a time. ll models utilize less water, energy and space than lavatories equipped with conventional faucets. The classic sprayhead (non-sectional) is controlled by an infrared sensor, electronic pushbutton or piezo switch, air activated pushbutton or foot rail. The washfountain bowls, pedestals and valve sets are completely assembled. Only the support column and connections to the valve set and drain require assembly. The operating range is 20-80 PSI. Flow rate controlled by volume control valve. onstruction owl Materials onstructed of, a densified solid surface material composed of bio-based resin. is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon is Home Innovation Lab certified to meet S 45.5/IPMO Z124. Terreon is GREENGURD certified as lowemitting materials. Pedestals onstructed of die-formed legs, upper braces, scuff bases and panels: legs are zinc chromate plated 14 gauge steel; upper braces are 16 gauge galvanized steel; and scuff bases and pedestals are 300 series stainless steel with a #4 finish. Standard Equipment Valves and Fittings In addition to the bowl and pedestal assembly, the following valves and fittings are standard: sprayhead with stainless steel support tube and bowl gasket; spud with domed strainer; sprayhead supply line; manual mixing valve; volume control valve; and (2) stop, strainer and check valves. ctivation ontrols Foot Each press of the foot rail mechanically actuates a hold-open valve, with slow closing upon release of foot pressure. ir Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 12 seconds. Each push button activates a flow of tempered water from the classic nonsectional sprayhead. Push button requires less than five pounds of pressure. Infrared Hands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from the classic non-sectional sprayhead. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conicalshaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a 12V plug-in adapter as standard equipment: Solenoid 12VD, 3/ NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage UL/S listed 120V/12VD plug-in adapter. Plugs into a standard GFI protected electrical outlet. of transformer per local electrical code. Page 1 of 7 4/2/2018 WF2504 TouchTime Each low-voltage mechanical pushbutton or piezo switch actuates a non-hold-open, slowclosing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the classic non-sectional sprayhead. TouchTime controls water flow at all stations through the use of solid state, digital circuitry. Timing is factory set at 12 second run time but is field adjustable to pre-set timeout periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Push button and piezo switch requires less than five pounds of pressure. ode ompliance and ertifications cup pproval Pre-ssembled lassic Washfountains are Uniform Plumbing ode (cup), International Plumbing ode (IP) and National Plumbing ode of anada certified through the International ssociation of Plumbing and Mechanical Officials (IPMO). Manufactured in compliance with IG 156-2012, S 45 Series-2002 (R2013) & SME 112.18.1-2012/ S 125.1-12. NSI Standards is Home Innovation Lab certified to meet S 45.5/IPMO Z124. Standard product selections contained within this document are third party ERTIFIED to NSF/NSI 372 meeting the Lead-Free content requirement. ny product configured with custom options will be OMPLINT with NSF/NSI 372 meeting the Lead-Free content requirement. ertified to NSF/NSI 372

Models (Must select one) Model Size Users Material WF2503 WF2504 WF2505 WF2508 36" Semi-ircular 5 Semi-ircular 36" ircular 5 ircular 3 4 5 8 Standard Selections (Must select one from each category) Drain Type (select one) Off-line vent with supplies from below entrally rising vent with supplies from above H entrally rising vent with supplies from below O Off-line vent with supplies from above Mounting Height Type (select one) STD Standard Height JUV Juvenile Height Sprayhead Type (select one) L lassic Sprayhead (entire sprayhead activates) ctivation Type (select one) F Foot IRP Infrared ST4 ir Pushbutton Water Supply Type (select one) TTP TouchTime Pushbutton*** TTP TouchTime Piezo Switch*** MMV Manual Mixing Valve TM Thermostatic Mixing Valve Soap Dispenser Type (select one) PSD Powdered Soap Dispenser LSD Liquid Soap Dispenser MLSD Metal-lad Liquid Soap Dispenser MPSD Metal-lad Powdered Soap Disp. S NSD ube dapter for Individual Soap Dispensers (dispensers sold separately) No Soap Dispenser owl olor (select one) SS-GRY Soapstone Gray -TN anyon Tan Optional Selections Shroud Type SH Stainless Steel Shroud (onceals Overhead Piping)* NONE No Shroud Type Support Tube Reinforcement Type T 1-1/2" Tie Pipe ssembly (not required when SH is selected) NONE No Tie Pipe ssembly Paper Towel Dispensers FTD SFTD NONE (2 for semi, 3 for circular) -Fold, Multi-Fold Dispenser (2 for semi, 3 for circular) Single-Fold Dispenser No Towel Dispenser Hose ibb Type H Hose ibb** NONE No Hose ibb *Non-cancelable, not-returnable ** vailable with STD height only. Non-cancelable, non-returnable. *** TTP and TTP require a low-voltage UL/S listed 120V/12VD plug-in adapter. Towel Dispenser with S option is non-cancellable and non-returnable. Required with drain, drain O and towel dispeners. Semi-ircular WF2503 and WF2504, ircular WF2505 and WF2508 WF2503 WF2504 WF2505 WF2508 Page 2 of 7 4/2/2018

Dimensional Infromation J I E dd 3-1/2" to Dimensions D & E for Optional TouchTime, Infrared Sensor or ir Valve D F H Semi-ircular G Model Size * * * D* ** E* ** F G H I J 2504 54 (1372) 19 (483) 29-1/2 (749) 38-3/4 (984) 47-1/4 (1200) 55-3/4 (1416) 36-1/2 (927) 23-1/2 (597) 21-1/4 (540) 32-1/4 (819) 5-1/4 (133) 2503 36 (914) 19 (483) 29-1/2 (749) 35-1/4 (895) 43-1/4 (1099) 52-1/4 (1327) 33-3/8 (848) 17-1/4 (438) 15-1/4 (387) 22-3/4 (578) 4-3/4 (121) * Juvenile Height: Subtract from dimensions through E for juvenile height. ** dd 3-1/2" (89) for optional TouchTime, infrared sensor or air valve. H E dd 3-1/2" to Dimensions D & E for Optional TouchTime, Infrared Sensor or ir Valve D ircular Model Size * * * D* ** E* ** F* G H 2505 54 (1372) 19 (483) 29-1/2 (749) 38-3/4 (984) 47-1/4 (1200) 55-3/4 (1416) 32 (813) 36 (914) 54 (1372) 2508 36 (914) 19 (483) 29-1/2 (749) 35-1/4 (895) 43-1/4 (1099) 52-1/4 (1327) 21 (533) 25 (635) 36 (914) * Juvenile Height: Subtract from dimensions through E for juvenile height. ** dd 3-1/2" (89) for optional TouchTime, infrared sensor or air valve. Page 3 of 7 4/2/2018 F G

Rough-In Notes 1. ll pipes and fittings not furnished by radley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. heck valve inlets are 1/2" NPT. 5. Drain Types and H: For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" NPT galvanized pipe for vent. Use of plastic or copper for vent is not recommended. Rough-Ins Semi-ircular Type 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) Type O 1" NPT Supplies Through Wall 2" NPT Drain Through Wall (Stub Out to Suit Trap Dimension) Trap * 3-1/ (83) See elow 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (64) bove Floor enter Line of Drain to enter Line of Fixture 5 (1372) 1" NPT Supplies from bove Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain 2" NPT Drain Through Wall (Stub Out to Suit Trap Dimension) See elow * Trap (22) (22) 1-1/ (32) 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) 5 (1372) enter Line of Drain to enter Line of Fixture Drain Through Wall Wall Trap for Wall Outlet Only Drain Through Wall Trap for Wall Outlet Only learance Hole learance Hole ** 12" (305) for Standard Height 8-1/ (210) for Juvenile Height ** Wall Supplies Through Wall Floor Drain and Supplies Through Floor Trap Located elow Floor (Optional) Floor Drain and Supplies Through Floor Trap Located elow Floor (Optional) Installing Traps When installing trap with a coupling and nipple, see dimension D in the chart below. If trap is installed tight to bottom of bowl, dimension D depends on design of trap. Model owl Size * ** (Standard Height) ** (Juvenile Height) 2504 5 (1372) 5-1/ (133) 6 to 13-1/ (152 to 337) 6 to 10-1/ (152 to 260) 2503 4-3/ (121) 6 to 13-1/ (152 to 337) 6 to 10-1/ (152 to 260) * Wall to centerline of trap ** enterline of drain to floor Page 4 of 7 4/2/2018

Rough-Ins Semi-ircular (continued) Type Type H 1" NPT Supplies from bove Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain 1-1/2" NPT Vent to eiling (22) 1" NPT Supplies Through Wall 1-1/2" NPT Vent to eiling 5 (1372) (22) 4-3/ (121) for owl 5-1/ (133) for 5 (1372) owl Wall 1-1/ (32) 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) Vent 5 (1372) 3-1/ (83) 4-3/ (121) for owl 5-1/ (133) for 5 (1372) owl Vent 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) 12" (305) for Standard Height 8-1/ (210) for Juvenile Height 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (63) bove Floor Floor Drain Through Floor Supplies Through Floor (Optional) Drain Through Floor Dimensions Pedestal nchoring Model owl Size Standard Height Juvenile Height 2504 5 (1372) 16-1/2" (419) 2503 36" (914) nchoring Pedestals 11" (279) 1 (356) 8-5/8" (219) 18-1/ (464) 18-1/ (464) 16-1/2" (419) 11" (279) 1. Place pedestal assembly as shown. 2. nchor pedestal assembly to floor and wall with suitable wall fasteners. acking may be required in some types of wall construction. 1 (356) 8-5/8" (219) 14-1/ (362) 14-1/ (362) Page 5 of 7 4/2/2018

Rough-Ins Semi-ircular (continued) Types and O Types and H Fixture enterline Fixture enterline Vented Trap 111-024 * D 11"* (279) Drain Through Floor (Optional) * Suggested location of 120V GFI electrical outlet. lways check local codes before installing. Outlet may be required to be in a remote location. (ll Types) (Types & H) (Types & O) D (Types & H) Standard Height Juvenile Height Standard Height Juvenile Height 4-3/ (121) 7" (178) 6 to 13-1/ (152 to 337) 6 to 10-1/ (152 to 260) 18-5/8" (473) 14-5/8" (371) Page 6 of 7 4/2/2018

Rough-Ins ircular Type Type Stub Up 2-1/2" (64) bove Floor Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain 2-1/2" (64) 5"* (127) onduit (Infrared Only) 1-1/ (32) 5"* (127) onduit (Infrared Only) 2" NPT Drain: Stub Up 3" (76) bove Floor 2" NPT Drain: Stub Up 3" (76) bove Floor 1-1/2" NPT Vent to eiling 5 (1372) owl owl 5 (1372) owl owl Type H Stub Up 2-1/2" (64) bove Floor Type O Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain 2" NPT Drain: Stub Up 3" (76) bove Floor 2-1/2" (64) 1-1/ (32) 5"* (127) onduit (Infrared Only) 1-1/2" NPT Vent to eiling 5"* (127) onduit (Infrared Only) 2" NPT Drain: Stub Up 3" (76) bove Floor owl owl 5 (1372) owl 5 (1372) owl * Remote mounting of plug-in adapter with 120 V electrical supply to washfountain is recommended. See local electrical codes before roughing in. (This conduit location is only a recommendation.) Page 7 of 7 4/2/2018