PART 1 THERMAL & MECHANICAL ACTIONS. DIF SEK Part 1: Thermal & Mechanical Actions 0/ 50

Similar documents
Seminar on Standardisation in Research and Innovation Practical tools for the dissemination and implementation of research results

Research on fire protection methods and a case study "Futurum"

DS/EN DK NA:2011

Fire Resistance - Implications for regulations and standards of the September 11th terrorist attacks on the world trade centre Tom Lennon, FRS, BRE

WG 1: Fire Engineering V. Strategy and guidelines for damage prevention Fire design in Europe

CHANCES AND LIMITS OF THE TIME-EQUIVALENCE-METHOD IN STRUCTURAL FIRE DESIGN

A tool to design steel elements submitted to compartment fires - OZone V2 Part 2: Methodology and application

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Current Research at University of Naples

This document is a preview generated by EVS

Fire Severity for Structural Design

Objective based approach

Fire resistance design in Europe

Fire safety systems. Behaviour of fires

Test One: The Uncontrolled Compartment Fire

Advantages and Disadvantages of Fire Modelling

Travelling Fires for CFD

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Gothenburg dance hall, Sweden, 1998

9-1. Introduction to fire design

Case Study 1 Underground Car Park

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Eurocode 9 Design of aluminium structures

FIRE SAFETY IN CONSTRUCTION: GETTING IT RIGHT

Sprinklers Modeling for Tunnel Road Fire Fighting

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

Tunnel Fire Dynamics and Evacuation Simulations

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Water Mist and Heritage Buildings Case - St. Mark s Dome, Venice

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

1.1. Design fires for structural engineering

First Revision No. 6-NFPA [ Section No. 2.2 ]

FAÇADE FIRE TESTS Towards a new European standard method

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

CFD Model of a Specific Fire Scenario

FIRE RESISTANCE LEVEL ASSESSMENTS AND DEVELOPMENT OF APPROPRIATE INPUT DATA

2C10 Design for Fire and Robustness Timisoara,

Practical problems of applying performance-based structural fire engineering in building design

This document is a preview generated by EVS

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Fire Scenario Influence of Material of Boundary Condition on Results

An experimental study of the impact of tunnel suppression on tunnel ventilation

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Computer Models For Fire and Smoke

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

A Priori Modelling of Fire Test One

CYS National Annex to CYS EN :2002

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Essentials of Fire Fighting 6 th Edition Firefighter I

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Considerations in the Design of Smoke Management Systems for Atriums

Modeling a real backdraft incident fire

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Appendix A: US Fire Statistics Tables

Sprinklers & Fire Safety and Climate Change. CFOA Conference Galway 8 May 2008

ON THE USE OF FIRE BRIGADE STATISTICS FOR STRUCTURAL FIRE SAFTY ENGINEERING

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

This document is a preview generated by EVS

Chapter 17, Initiating Devices

SIMULATION OF A COMPARTMENT FLASHOVER FIRE USING HAND CALCULATIONS, ZONE MODELS AND A FIELD MODEL

CFD Simulation of the Water Mist Effect on Fire

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

Fire Protection for Printing Machines with High Pressure Water Mist

THERMAL EFFECT OF A LOCALIZED FIRE IN THE STEEL STRUCTURE OF AN OPEN CAR PARK

Case Study 2 (Production and Storage Buildings) - Spain

Simulation of Full-scale Smoke Control in Atrium

The first tunnel fire. Benefits of fire

Case Study 1 Underground car park

CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES

Smoke Layer Height and Heat Flow through a Door

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

2015 SFPE Europe Conference on Fire Safety Engineering

Computational simulation of road tunnel fire protection by sprinklers

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Fire classification of construction products and building elements

Analysis of ventilation system for a microwave assisted drying unit

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Fire safety engineering applied to high-rise building facades

technical specification smoke venting systems

This document is a preview generated by EVS

So, How do Fire Starts & Spreads? A question we need to understand and appreciate the dynamics of fire life cycle.

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Overview of the PRISME project Technical Description and Main Outcomes

FIRE RESISTANCE TESTING

On Estimating Heat Release Rate for a Design Fire in Sprinkler Protected Area

HART XL High Sensitivity Smoke Detection

TUNPROTEC. Active Tunnel Fire Protection

Transcription:

DIF SEK PART 1 THERMAL & MECHANICAL ACTIONS DIF SEK Part 1: Thermal & Mechanical Actions 0/ 50

Background of the RFCS Project DIFISEK+ This project is funded by the European Commission in the frame of the Research Fund for Coal and Steel The aim of DIFISEK+ is to promote different projects of the last decades d that t dealt with fire engineering i and, which h results have been implemented in the EN 1991-1-2. This objective will be reached trough seminars held in different European countries. The partnership of the project is as follows: University of Hannover Institute for Steel Construction DIF SEK Part 1: Thermal & Mechanical Actions 1/ 50

Treated Topics Part 1: Thermal & Mechanical Actions Part 2: Thermal Response Part 3: Mechanical Response of Structures in Fire Part 4: Software for Fire Design Part 5a: Worked Examples Part 5b: Illustration of Completed Projects DIF SEK Part 1: Thermal & Mechanical Actions 2/ 50

Resistance to Fire - Chain of Events Θ Loads 1: Ignition Steel columns time 2: Thermal action 3: Mechanical actions R 4: Thermal response time 5: Mechanical response 6: Possible collapse DIF SEK Part 1: Thermal & Mechanical Actions 3/ 50

Thermal action on structure Composite Slab Column 1 side exposed 4 sides exposed DIF SEK Part 1: Thermal & Mechanical Actions 4/ 50

Heat transfer at surface of building elements h = + net, = h& h& net,c & + net r Net Radiative Heat Flux Net Convective Heat Flux Total net Heat Flux Exposed side Non-exposed side DIF SEK Part 1: Thermal & Mechanical Actions 5/ 50

Structural Fire Safety Engineering vs. Classification Prescriptive Performance based standard d fire natural fire classification fire safety eng. fire safety eng. fire safety eng. DIF SEK Part 1: Thermal & Mechanical Actions 6/ 50

Actions on Structures Exposed to Fire ČSN EN 1991-1-2 1 - Prescriptive Rules Design Procedures Prescriptive Rules Performance-Based Code (Thermal Actions given by Nominal Fire) (Physically based Thermal Actions) DIF SEK Part 1: Thermal & Mechanical Actions 7/ 50

Nominal Temperature-Time Curve *) Nominal temperature-time curve Standard d temperature-, t External fire - & Hydrocarbon fire curve No data needed *) Simplified Fire Models Localised Fire Fully Engulfed Compartment - HESKESTADT - Parametric Fire Rate of heat release - HASEMI θ (t) uniform Fire surface θ (x, y, z, t) in the compartment t Boundary properties Opening area Ceiling height *) Advanced Fire Models + - Two-Zone Model - One-Zone Model - Combined Two-Zones and One-Zone fire -CFD Exact geometry DIF SEK Part 1: Thermal & Mechanical Actions 8/ 50

Prescriptive Fire Regulations Defining ISO Curve Requirements 1200 800 ISO-834 Curve (EN1364-1) θ [ C] T = 20 + 345 log (8 t + 1) 1049 1006 1000 The ISO curve 945 600 842 1110 * Has to be considered in the WHOLE compartment, even if the compartment is huge ISO ISO ISO ISO ISO 400 200 ISO ISO ISO * Never goes DOWN Time [min] * does not consider the PRE-FLASHOVER PHASE * Does not depend on FIRE LOAD and VENTILATION CONDITIONS 0 0 30 60 90 120 180 DIF SEK Part 1: Thermal & Mechanical Actions 9/ 50

Stages of a Natural Fire and the Standard Fire Curve Temperature Pre- Flashover Post- Flashover 1000-1200 C Flashover Natural fire curve ISO834 standard fire curve Ignition - Smouldering Heating Cooling. Time DIF SEK Part 1: Thermal & Mechanical Actions 10 / 50

Sprayed Protection DIF SEK Part 1: Thermal & Mechanical Actions 11 / 50

Partially Encased Beams & Columns DIF SEK Part 1: Thermal & Mechanical Actions 12 / 50

Actions on Structures Exposed to Fire ČSN EN 1991-1-2 1 - Performance Based Code Design Procedures Prescriptive Rules (Thermal Actions given by Nominal Fire) Performance-Based Code (Physically based Thermal Actions) DIF SEK Part 1: Thermal & Mechanical Actions 13 / 50

Natural Fire Safety Concept 1200 θ [ C] 1000 800 600 400 200 0 0 30 60 90 120 180 Time [min] Implemented in: ČSN EN 1991-1-2 Some National Fire Regulations include now alternative requirements based on Natural Fire DIF SEK Part 1: Thermal & Mechanical Actions 14 / 50

NFSC Valorisation Project DIF SEK Part 1: Thermal & Mechanical Actions 15 / 50

Natural Fire Model *) Nominal temperature-time curve Standard d temperature-, t External fire - & Hydrocarbon fire curve No data needed *) Simplified Fire Models Localised Fire Fully Engulfed Compartment - HESKESTADT - Parametric Fire Rate of heat release - HASEMI θ (t) uniform Fire surface θ (x, y, z, t) in the compartment t Boundary properties Opening area Ceiling height *) Advanced Fire Models + - Two-Zone Model - One-Zone Model - Combined Two-Zones and One-Zone fire -CFD Exact geometry DIF SEK Part 1: Thermal & Mechanical Actions 16 / 50

List of needed Physical Parameters for Natural Fire Model Boundary properties Ceiling height Opening Area Fire surface Rate of heat release Geometry Fire DIF SEK Part 1: Thermal & Mechanical Actions 17 / 50

Characteristics of the Fire Compartment Fire resistant enclosures defining the fire compartment according to the national regulations Material properties of enclosures: c, ρ, λ Definition of Openings DIF SEK Part 1: Thermal & Mechanical Actions 18 / 50

Characteristic of the Fire for Different Buildings Occupancy Fire Growth RHR Fire Load q Rate f [kw/m²] 80% fractile [MJ/m²] Dwelling Medium 250 948 Hospital (room) Medium 250 280 Hotel (room) Medium 250 377 Library Fast 500 1824 Office Medium 250 511 School Medium 250 347 Shopping Centre Fast 250 730 Theatre (movie/cinema) Fast 500 365 Transport (public space) Slow 250 122 f,k DIF SEK Part 1: Thermal & Mechanical Actions 19 / 50

Fire Load Density Compartment Danger of Fire Activation floor area A f [m²] δ 25 250 2500 5000 δ q1 1,10 1,50 1,90 2,00 Danger of Fire Activation δ q2 0,78 1,00 1,22 1,44 10000 2,13 1,66 = δ ni Function δ of δ Active. Fire Safety δmeasures. m. f, d q1 q 2 ni q. Examples of Occupancies Art gallery, museum, swimming pool Residence, hotel, office Manufactory for machinery & engines Chemical laboratory, Painting workshop Manufactory of fireworks or paints Automatic Fire Suppression Automatic Fire Detection Manual Fire Suppression q f, k Automatic fire Automatic Automatic Independent Water Water Detection Alarm Extinguishing Supplies & Alarm Transmission System by by to 0 1 2 Heat Smoke Fire Brigade δ n1 δ n2 δ n3 δ δ n4 n5 Work Fire Brigade Off Site Fire Brigade Safe Access Routes Fire Fighting Devices δ n6 δ n7 δ n8 δ n9 Smoke Exhaust System δ n10 0,61 0,87 or 0,73 0,87 1,0 0,87 0,7 0,61 or 0,78 0,9 or 1 1,5 1,0 1,5 1,0 1,5 DIF SEK Part 1: Thermal & Mechanical Actions 20 / 50

Rate of Heat Release Curve Stationary State and Decay Phase RHR [MW] 0 RHR [MW W] 5RHR [MW W] 70% (q f,d A fi ) 10 9 Steady Growing state phase A f x RHR f 10 Ultra- 8 Fast (FGR) 9 Fast COMPARTMENT FIRE (FGR) 7 8 6 Medium (FGR) 7 5 6 4 Fire AGrowth f x RHR Rate = FGR f 3 4 Ventilation Controlled Slow (FGR) Fire 2 3 2 1 Decay phase 75'' 150'' 300'' 600'' Decay Phase t [min] 1 0 0 5 10 15 20 25 t [min] 30 0 0 5 10 15 20 t decay Time [min] DIF SEK Part 1: Thermal & Mechanical Actions 21 / 50

Natural Simplified Fire Model *) Nominal temperature-time curve Standard d temperature-, t External fire - & Hydrocarbon fire curve No data needed *) Simplified Fire Models Localised Fire Fully Engulfed Compartment - HESKESTADT - Parametric Fire Rate of heat release - HASEMI θ (t) uniform Fire surface θ (x, y, z, t) in the compartment t Boundary properties Opening area Ceiling height *) Advanced Fire Models + - Two-Zone Model - One-Zone Model - Combined Two-Zones and One-Zone fire -CFD Exact geometry DIF SEK Part 1: Thermal & Mechanical Actions 22 / 50

Simplified Fire Models Localised Fire LOCALISED FIRE θ (x, y, z, t) FULLY ENGULFED COMPARTMENT θ (t) uniform in the compartment DIF SEK Part 1: Thermal & Mechanical Actions 23 / 50

Localised fire test DIF SEK Part 1: Thermal & Mechanical Actions 24 / 50

Localised Fire: HESKESTAD Method Annex C of ČSN EN 1991-1-2: Flame is not impacting the ceiling of a compartment t (L f <H) Fires in open air Flame axis Θ = + 2/3 (z-z -5/3 (z) 20 0,25 (0,8 Q c ) z 0 ) 900 C The flame length L f of a localised fire is given by : H L =-1,02 + 2/5 f D 0,0148 Q L f z D DIF SEK Part 1: Thermal & Mechanical Actions 25 / 50

Localised Fire: HASEMI Method Annex C of ČSN EN 1991-1-2: Flame is impacting the ceiling (L f > H) concrete slab beam θg Y = Height of the free zone θ = Air Temperature at Beam Level Calculated by CaPaFi DIF SEK Part 1: Thermal & Mechanical Actions 26 / 50 x

Simplified Fire Models Fully Engulfed Compartment LOCALISED FIRE θ (x, y, z, t) FULLY ENGULFED COMPARTMENT θ (t) uniform in the compartment DIF SEK Part 1: Thermal & Mechanical Actions 27 / 50

Real Fire Test Simulating an Office Building Fully engulfed fire DIF SEK Part 1: Thermal & Mechanical Actions 28 / 50

Fully Engulfed Compartment Parametric Fire Temperature [ C] Annex A of ČSN EN 1991-1-2 1100 Iso-Curve 1000 O = 0.04 m 900 O = 0.06 m 800 O = 0.10 010m 700 O = 0.14 m O = 0.20 m 600 For a given b, q fd, A t & A f 500 400 300 200 100 time [min] 0 0 10 20 30 40 50 60 70 80 90 100 110 120 DIF SEK Part 1: Thermal & Mechanical Actions 29 / 50

Natural Advanced Fire Model *) Nominal temperature-time curve Standard d temperature-, t External fire - & Hydrocarbon fire curve No data needed *) Simplified Fire Models Localised Fire Fully Engulfed Compartment - HESKESTADT - Parametric Fire Rate of heat release - HASEMI θ (t) uniform Fire surface θ (x, y, z, t) in the compartment t Boundary properties Opening area Ceiling height *) Advanced Fire Models + - Two-Zone Model - One-Zone Model - Combined Two-Zones and One-Zone fire -CFD Exact geometry DIF SEK Part 1: Thermal & Mechanical Actions 30 / 50

Advanced fire Models LOCALISED FIRE The Fire stays localised The Fire switch to a fully engulfed fire LOCALISED FIRE FULLY ENGULFED COMPARTMENT DIF SEK Part 1: Thermal & Mechanical Actions 31 / 50

Large Compartment Test Fire Load DIF SEK Part 1: Thermal & Mechanical Actions 32 / 50

Large Compartment Test External Flaming During the Test DIF SEK Part 1: Thermal & Mechanical Actions 33 / 50

Large Compartment Test After the Test DIF SEK Part 1: Thermal & Mechanical Actions 34 / 50

Two Zone Calculation Software OZone V2.2 DIF SEK Part 1: Thermal & Mechanical Actions 35 / 50

OZone results: Input and Computed RHR DIF SEK Part 1: Thermal & Mechanical Actions 36 / 50

OZone results: Gas Temperatures θ Hot θ Cold DIF SEK Part 1: Thermal & Mechanical Actions 37 / 50

OZone results: Smoke Layer Thickness DIF SEK Part 1: Thermal & Mechanical Actions 38 / 50

Calibration of Software OZone: Gas Temp 1400 1200 MAXIMUM AIR T EMPERATURE OZone 1000 OZon ne [ C] 800 600 400 200 0 MAXIMUM AIR T EMPERATURE IN THE COMPARTMENT 0 200 400 600 800 1000 1200 1400 TEST [ C] DIF SEK Part 1: Thermal & Mechanical Actions 39 / 50

Calibration of Software OZone: Steel Temp 1400 1200 UNPROTECTED STEEL TEMPERATURE 1000 OZo one [ C] 800 600 400 200 0 0 200 400 600 800 1000 1200 1400 TEST [ C] DIF SEK Part 1: Thermal & Mechanical Actions 40 / 50

OZone: Case Study Gas te emperature e [ C] 1000 900 800 700 600 500 400 300 200 100 0 Influence of the Actives Fire Safety Measures q m δ δ f,d= q1 q2 δ i ni q f,k Office : A f = 291,2 m² O.F. = 0,04 m½ ; Fire Load No Fire Active Measures Off Site Fire Brigade q f,k = 511 MJ/m² Automatic Fire Detection & Alarm by Smoke Automatic Alarm Transmission to Fire Brigade Automatic Water Extinguishing System Design Fire Load q f,d [ MJ/m² ] 625 356 310 189 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Time [min] DIF SEK Part 1: Thermal & Mechanical Actions 41 / 50

Computer Fluid Dynamics: Software Sofie Grid definition DIF SEK Part 1: Thermal & Mechanical Actions 42 / 50

Sofie Results: Gas Temperatures DIF SEK Part 1: Thermal & Mechanical Actions 43 / 50

Resistance to Fire - Chain of Events Θ Loads 1: Ignition Steel columns time 2: Thermal action 3: Mechanical actions R 4: Thermal response time 5: Mechanical response 6: Possible collapse DIF SEK Part 1: Thermal & Mechanical Actions 44 / 50

Basis of Design and Actions on Structures S W G Q A C T I O N S Actions for temperature analysis Thermal Action FIRE Actions for structural analysis Mechanical Action Dead Load G Imposed Load Q Snow S Wind W Fire DIF SEK Part 1: Thermal & Mechanical Actions 45 / 50

Combination Rules for Mechanical Actions ČSN EN 1990: Basis of Structural Design Room temperature E γ G + γ Q + ψ γ d Q = G Q,1 1 0,i Qi Q,i i i >1 f.i. : Offices area with the imposed load Q, the leading variable action E d = 1,35 G + 1,5 Q + 0,6 1,5 W + 0,5 1,5 S DIF SEK Part 1: Thermal & Mechanical Actions 46 / 50

Combination Rules for Mechanical Actions ČSN EN 1990: Basis of Structural Design Fire conditions Accidental situation E fi,d = G + ψ 1or2,1 Q 1 + i >1 ψ 1or2,i Q i f.i. : Offices area with the imposed load Q, the leading variable action E fi,d = G + 0,5 Q Offices area with the wind W, the leading variable action E fi,d = G + 0,2 W + 0,3 Q DIF SEK Part 1: Thermal & Mechanical Actions 47 / 50

Values of ψ factors for buildings Action Imposed loads in buildings, category (see ČSN EN 1991-1.1) Category A : domestic, residential areas Category B : office areas Category C : congregation areas Category D :shopping areas Category E : storage areas Category F : traffic area vehicle weight 30kN Category G : traffic area, ψ 0 ψ ψ 1 2 30 kn < vehicle weight 160kN 0,7 0,5 0,3 Category H : roofs 0 0 0 Snow loads on buildings (see ČSN EN 1991-1.3) Finland, Iceland, Norway, Sweden 070 0,70 050 0,50 020 0,20 Remainder of CEN Member States, for sites located at altitude 0,70 0,50 0,20 H > 1000 m a.s.l. Remainder of CEN Member States, for sites located at altitude 0,50 0,20 0 H 1000 m a.s.l. Wind loads on buildings (see ČSN EN 1991-1.4) 0,6 0,2 0 Temperature (non-fire) in buildings (see ČSN EN 1991-1.5) 0,6 0,5 0 DIF SEK Part 1: Thermal & Mechanical Actions 48 / 50 0,7 0,7 0,7 07 0,7 1,0 0,7 0,5 0,5 0,7 07 0,7 0,9 0,7 0,3 0,3 0,6 06 0,6 0,8 0,6 ( Reference : ČSN EN 1990-2004)

Load Factor η fi = γ G k + ψ fiqk, l GG k + γ Q, l Qk, l Load Fa actor E fi,d / R fi,d,t [-] 1 0.9 0.8 0.7 06 0.6 0.5 0.4 03 0.3 0.2 0.1 0 Maximal Load level after R30 0 50 100 150 200 250 300 350 400 Massivity A m /V [1/m] DIF SEK Part 1: Thermal & Mechanical Actions 49 / 50

National Annex to ČSN EN 1991-1-2 Annex normative for buildings located in the Czech Republic Allows to change 10 parameters In 9 cases the values from EN 1993-1-2 are used without any changes In paragraph NA 2.10 is recommended, especially by halls for snow and wind load, during fire attack to apply the frequent value of live load ψ 1,1 Q 1 DIF SEK Part 1: Thermal & Mechanical Actions 50 / 50

Thank you for your attention DIF SEK Part 1: Thermal & Mechanical Actions