Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

Similar documents
DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

WCAD-Series Vended Washers Troubleshooting And Fault Codes

WC Series Vended Washers Troubleshooting, and Fault Codes

Section: 6. Parts Data DC30X2. Part # /14

WCVD-Series OPL Washers Troubleshooting And Fault Codes. Starting serial number ****** (09/13)

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Section 6: Parts Data. DDAD30KC_-65 Part # /13

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Technical

Flame Safeguard Fault Code Diagnostics

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

AD-236 Parts Manual. 24 VAC Phase 5

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Technical

DEXTER STACK DRYER PROGRAMMING PROCEDURES AND FEATURES

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

CLOTHES DRYER Technical Information

Slow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)

New Power Vented Rheem FVIR Tanks

Each heater has slightly different operational characteristics

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

CLOTHES DRYER Technical Information

Manual P/N M0MG32MS. Revision 6/F3587 February, 2005

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Drying Tumblers. Troubleshooting. 120 Pound Capacity 170 Pound Capacity. Refer to Page 5 for Model Numbers. Part No August 2007

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Section 5: Dryer Parts Data. Part # /11

Hot Surface Ignition (HSI) System Booklet

Tumble Dryers. Troubleshooting. 50 Pound Capacity 75 Pound Capacity. Refer to Page 7 for Model Numbers.

XIII Troubleshooting

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Interrupted Ignition Series Oil Primary Control

FURNACE OPERATION OVERVIEW

AD-235ED Parts Manual 24 VAC Phase /2000

Figure 10 or Figure 6

AD-230 Parts Manual. Phase 5 24 Vac

Service Manual Model 3163

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

AHE S -12 VDC AHE S - 24 VDC

Section 5: Dryer Parts Data. Part # /11

COMMERCIAL WASHER MODEL T-600 VENDED C-SERIES CONTROL

Customer Service...1. Calibration...8. Inspection...9. Lighting Cleaning Features Control Box Digital Timers...

Suburban RV FURNACES SERVICE MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

COMMERCIAL GAS WATER HEATERS

Condensing Models. On-Demand Water Heater Service Handbook

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

Installation and Troubleshooting Instructions for Electric Tankless Commercial Water Heaters CE 12 KW, CE 15 KW, CE 18 KW CE 24 KW CE 27 KW CE 48 KW

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Electronic Ignition Water Heater

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

AD-235 Parts Manual. (for models mfd. between 1989 and 1991)

LNB 1000 Series Low Nox Burner

Thermo 230 / 231 / 300 / 301 / Troubleshooting

C-Series Vended Washers T300, T400, T600 (100G) & T350, T450 (Express Washers 200G)

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

BOSCH CONDENS 5000W ZSB18-2A

29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

INSTRUCTION MANUAL FOR OIL BURNER MODELS

ADG-531HS Hot Surface Ignition

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Proper maintenance of tunnel finisher will prolong its life and enable the equipment to produce the best possible quality.

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

Model 60200FR Gas Primary Control Data Sheet

GAS DRYER MODELS: (White) (Chrome Shadow) 01/28/ Sears Brands, LLC Part No. W Rev. A

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

User s Information Manual

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

Service. Compact Dryer MDE2400AY*

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

AD-170 Parts Manual. Phase 4. (for models mfd. prior to 1992)

CROSSOVER. In a class by itself. Laundrylux. DAWF0 and DAWS0 SERIES DRYERS ! DRYER PARTS MANUAL "

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Emerson Blue Easy Set 1H/1C

DOMESTIC HOT WATER Follow operational sequence

AD-115ES Parts Manual

Product Information and Technical Guide

1F98EZ-1421, Easy Install

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Smart Temp. Model

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

AD-24 Parts Manual 24 VAC Phase 7

ML-82 Parts Manual. Phase 7 Microprocessor with F.S.S. Options

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

ES-5050 / ES5050TE Parts Manual

Operator: Save these instructions for future use!

Transcription:

Dexter Commercial Vended Stack Washer Dryer Dryer Troubleshooting, Fault Codes, And Schematics Starting serial number 481983 8533-070-001 (12/13)

Dryer Trouble Shooting Electronic Control Diagnostic Lights The electronic control has 3 diagnostic lights to aid in service of the dryer. Each pocket has indicator lights for the motor circuit, door switch circuit, and the heat circuit. When the electronic control is carefully unlocked and moved forward these lights are visible on the circuit board. They are each labeled as to function indicated. 1. When dryer door is closed, the door light on the computer should be illuminated indicating that the door is closed. 2. When dryer is running, the motor light on the computer should be illuminated indicating that the computer is calling for the motor to operate. 3. When dryer is calling for heat, the heat light on the computer should be illuminated indicating that the computer is calling for heat. An example of their function would be troubleshooting a dryer pocket that did not heat. 1. Start the machine and insure that it did not heat. 2. Check the heat light and see if it is lit. 3. If the heat light is on, this would indicate that the computer was calling for heat and that it was not at fault. You would then go on to check the rest of the heat circuit. Electronic Control Test Cycle This test cycle allows the dryer to run for 5 minutes without the need for adding money while servicing. To actuate this 5 minute test cycle leave the loading doors closed, unlock the computer and push the program button on the right front corner of the computer as if you were putting it into the program mode. This will give a 5 minute cycle on both tumblers for evaluating the machine. Trouble Shooting Fault Codes F1 Shorted sensor or shorted sensor wire harness F2 Open sensor or sensor wire harness disconnected F3 Possible grounding problem. Try powering down and repowering and then push programming button to start dryer. Try resetting with Palm Pilot (extra utilities fi le). If no success. Try removing battery and reinstall battery. F4 Micro Chip Problem. Replace controller. F5 Microchip Electrical Problem. Remove power for 1 minute and then power on. Try removing battery and reinstalling on control PCB/ Troubleshooting Tips Symptom Probable Cause Suggested Remedy Tumbler does not turn Drive belts Check both drive belts. Replace if failed. Drive motor Check capacitor and motor. Replace if failed Door switch Check door switch contacts and adjustment. Adjust or replace door switch. 2 Electronic Control Is electronic control closing motor relay to power drive motor? Check for motor light on electronic control. If no light change control. If light is on, check voltage and wiring to motor.

Symptom Probable Cause Suggested Remedy Tumbler turns but no spark at burner Glass fuse Check small glass control fuse in back of dryer. Replace if failed. Temperature Sensor The temperature sensor should have between 30,000 ohms and 60,000 ohms resistance at room temperature if okay. Replace if not in this range. Ignition Check for 24VAC output from transformer. Transformer Replace if have 120V between black & white and no 24V between red and yellow. Over temperature Check to see if manually resettable thermostat. Thermostat is kicked out. Reset by pushing red reset button. Ignition control Check for 24VAC coming into the control on the at burner red wire. If voltage, then check for 24VAC out on the brown wire. Also check for spark at the ignitor. If no 24VAC output or no spark to the ignitor, replace ignition control. Air Flow Switch Check air fl ow switch to be sure it closes when dryer is running. If not, adjust or replace switch. Hi-limit Check for continuity. Should be 0 ohms resistance when cold. If not, replace thermostat. Gas supply No gas can cause system lockout Electronic Control Is electronic control closing gas relay to power Control heat circuit? Check for gas light on electronic control. If no light change control. If light is on, check voltage and components in heat circuit at transformer at rear of unit. Tumbler turns, ignition sparks, no fl ame Gas supply Make sure gas supply is working. Gas pressure Make manometer check of gas pressure. Adjust if necessary. Spark Electrode Sensor Check for damage to electrode or mounting. Replace if necessary. Gas valve Check coil continuity, replace valve if failed. Ignition Control Check for 24VAC to gas valve coils. If no voltage replace ignition control. 3

Symptom Probable Cause Suggested Remedy Burner Lights, but goes on and off Electrodes Check low voltage harness for possible wire break or cuts to allow no signal back to ignition control Slow drying Temperature Setting Check program for correct high temperature setting. Adjust if necessary. Air fl ow restrictions necessary 1. Check lint screen and clean if necessary. 2. Check exhaust for correct length and clean if necessary. 3. Check exhaust damper to insure that it opens when dryer is running and closes when dryer is not in use. 4. Check makeup air to insure that it is adequate. Increase makeup air if necessary. 5. Check static Back pressure no more than.3 Temperature Sensor The temperature sensor should have between 30,000 ohms and 60,000 ohms resistance at room temperature if okay. Replace if not in this range. Erratic display Initial Start-up If erratic on initial start-up, leave power on for approximately one hour and check machine operation again. Grounding Machine must be grounded by separate conductor back to neutral bar in breaker box. Program Check program and make corrections if necessary. Voltage spike Power down machine for 20 seconds and repower. If no improvement, replace control. Manual overtemp Tripping Frequently Recirculating chamber Lint Accumulation Remove manual overtemp thermostat and inspect in chamber for excessive lint build up. Access also gained to this chamber by removing recirculation duct mounted at bottom of chamber, or the panel inside burner chamber between burners and rear back panel Exhaust ducting Excessive lint buildup Remove exhaust duct at rear of dryer and inspect for excessive lint build up in complete duct from dryer to where duct exits building. Clean linto of of top heat air chamber above tumbler Remove front panel completely. Be careful of any wiring attached. Remove heated air chamber cover and clean above tumbler back to burner housing. 4

Wiring Schematic for Electronic Acceptor Dryer 5

Wiring Diagram for Electronic Acceptor Dryer -10Cp 6

Wiring Schematic for Easy Card Dryer 7

Wiring Diagram for Easy Card Dryer 8