Catalog Number. Notes

Similar documents
Catalog Number. Notes

Catalog Number. Notes

Catalog Number. Notes. Type ADP. Series Air function Lumens Diffuser Voltage Driver Color temperature. Acrylic linear prismatic

Oh, Lic# SHOP DRAWINGS Lake Erie Electric, Inc. FOR DWG.& SPEC. CONFORMITY ONLY D.M.Y 08/15/2016

LOW PROFILE 4 APERTURE UP TO 4800 LUMENS DELIVERED LLP4/LLPRM4 SERIES

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

800 TO 9000 LUMEN 10 LED RETRO-FIT HYPERBOLIC / PARABOLIC LRT10 SERIES

BAS SFP22 Edge-lit LED Panel

CERRA 10 LED Design2Ship

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

IECC. nlight Applications Guide.

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

BAS SDL8' LED Strip Diffused Lens

SDL4 LED Strip Diffused Lens

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) (111mm) 3 (76mm)

800 TO 8000 LUMEN 4 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L4 / LRM4 SERIES

Catalog # Project. Comments. Prepared by. 23-3/4" [603mm] LAMP CONFIGURATIONS. 3-1/4" [83mm] X=2-7/16" [62mm] Y=2-1/2" [64mm] CEILING COMPATIBILITY

800 TO 9000 LUMEN 8 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L8 / LRM8 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

Catalog Number. Notes

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

9533, 9534, 9535, 9537 Shower Curtain Model 9535 & 9537 Antimicrobial Shower Curtain

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Catalog Number. Notes. Type

800 TO 5500 LUMEN 6 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC6 SERIES

800 TO 2800 LUMEN 4 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC4 SERIES

VESICA LINEAR SUSPENDED VES L

800 TO 5500 LUMEN 8 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC8 SERIES

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

Grüv Flare Regressed. Recessed Linear LED

lumenalpha downlight Specification Sheet

Grüv Flare Regressed. Recessed Linear LED

Alliance 4 - ALI4 LED 4 Linear High Bay

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

DHL-LP-LED Low Profile LED Linear High/Low Bay

RECESSED T-Bar & Drywall

Catalog Number. Notes

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

Addendum # 1 to Bid MEB Audiovisual Faculty Training Center Renovation

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

DIMMING 0-10V Continuous

Luminaire Type: Catalog Number: Slot Trim (SLT) MYO Configurable 1, 2 & 3-Head Recessed Multiple Series

LHBXD LED Linear High Bay

Max 4 Flush Lens RECESSED

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Catalog Number. Notes. Type. IBL Series Lumens Distribution Lens Voltage Color temperature

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

LIGHTING WITHOUT LIMITS. Manufacturers of LED and Fluorescent Luminaires

FPLHB - Fidelux Premier Linear Highbay

Mini Product Guide.

Lighting Control Strategies. to meet code requirements save energy and improve building performance

TROFFER RETROFIT KIT (TRK)

Project Name. Date. Cat. Number. Type

PROJECT DATE FLANGE FINISH

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget

I-BEAM LED The Top Choice For Your Bottom Line.

LED RETROFIT CONVERSION KITS

Evolve LED Garage Light

LED ECO PANEL.

11.4 lbs (5.2 kg) 13.2 lbs (6 kg) 17.6 lbs (8 kg) ORDERING INFORMATION MODEL LED COLOR TEMP. VOLTAGE LED DRIVER. 4000K (80 CRI) (Std.

RECESSED Spec Guide. up to 111 lm/w performance

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Highbay Linear LED Series Flat Profile Design

Catalog Number. Notes

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

ARCHWAY TM PASSAGE TM

WARRANTY LED ECO PANEL.

Metalux 4WSL / 8WSL LED

LED RETROFIT CONVERSION KITS

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

RECESSED - WITH StepLens OPTION

RLN Recessed LED luminaire

Catalog Number. Notes

Recessed LED Wall/Slot SAE 202

Lumination LED Luminaires

Metalux 4WSL / 8WSL LED

FEATURES & SPECIFICATIONS INTENDED USE

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Trees to be preserved. Site conditions 1/32 =1 Final Project - Porto Portugal, Dennis Selke Spring 2016 AR833 John Dobyns, Instructor

North Hanover Township School District North Hanover Township, New Jersey

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

THINTEK G2 PANEL.

THINTEK G2 PANEL.

You need solutions FAST. We are LightQuick.

ArcLine Recessed LED luminaire

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

RTC Recessed LED center basket

Claude Indirect Wall WALL

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Transcription:

Catalog Number FEATURES & SPECIFICATIONS INTENDED USE The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design that offers a clean, versatile style and volumetric distribution. High efficacy LED light engines deliver energy savings and low maintenance compared to traditional sources. An extensive selection of configurations and options make the BLT the perfect choice for many lighting applications including schools, offices and other commercial spaces, retail, hospitals and healthcare facilities. The low profile BLT design (-/8") also makes it an excellent choice for renovation projects. CONSTRUCTION BLT enclosure components are die-formed for dimensional consistency and painted after fabrication with a polyester powder paint for improved performance and protection. The reflector is finished with a high reflective matte white powder paint for improved aesthetics and increased light diffusion. End plates contain easy-to-position integral T-bar clips for securely attaching the luminaire to the T-grid. For additional T-grid security, optional screw on T-bar clips are available. Diffusers are extruded from impact modified acrylic for increased durability. Injection molded diffuser light traps add a finished look to the diffuser ends and help seal the diffuser to the housing end plates. Optional diffuser trim rings provide an attractive mounting for integral sensors as well as adding a decorative element to the luminaire aesthetics. LED boards are accessible from below; driver is accessible from the plenum. OPTICS Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions and vertical and horizontal work surfaces rendering the interior space, objects and occupants in a more balanced, complimentary luminous environment. High performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution. Four diffuser choices available - curved and square designs with linear prisms or a smooth frosted finish. ELECTRICAL Long-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. % LED lumen maintenance at, hours (L/,). Non-Configurable BLT: -1 volt dimming driver. Dims to 1% Configurable BLT: available in High Efficiency (HE) versions for applications where a lower wattage (over the standard product) is required. The High Efficiency versions deliver >1 LPW and can be specified via the Lumen Package designations in the Ordering Information below. eldoled driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI. Optional integrated nlight controls make each luminaire addressable - allowing it to digitally communicate with other nlight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Simply connect all the nlight enabled control devices and the BLT luminaires using standard Cat- cabling. Unique plug-and-play convenience as devices and luminaires automatically discover each other and self-commission. Lumen Management: Unique lumen management system (option N8) provides on board intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting. Step-level dimming option allows system to be switched to % power for compliance with common energy codes while maintaining fixture appearance. Driver disconnect provided where required to comply with US and Canadian codes. SENSOR Integrated sensor (individual control): Sensor Switch MSDADCX ((Passive infrared (PIR)) or MSDPDTADCX ((PIR/Microphonics Dual Tech (PDT)) integrated occupancy sensor/automatic dimming photocell allows the luminaire to power off when the space is unoccupied or enough ambient light is entering the space. See page for more details on the integrated sensor. Integrated Sensor (nlight Wired Networking): This sensor is nlight-enabled, meaning it has the ability to communicate over an nlight network. When wired, using CAT- cabling, with other nlight-enabled sensors, power packs, or WallPods, an nlight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. See page for the nlight sensor options. INSTALLATION The BLT s low profile design of only -/8 provides increased installation flexibility especially in restrictive plenum applications. The BLT fits into standard 1/16 and narrow 9/16 T-grid ceiling systems. Suitable for damp location. For recessed mounting in hard ceiling applications, Drywall Grid Adapters (DGA) are available as an accessory. See Accessories section. LISTINGS CSA Certified to meet U.S. and Canadian standards. IC rated. DesignLights Consortium (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/qpl to confirm which versions are qualified. WARRANTY -year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at C. Specifications subject to change without notice. Notes Type Specifications Length: -/4 (.) Width: -/4 (.) Depth: -/8 (6.) Depth with Air Option: -/4 (6.9) All dimensions are inches (centimeters) unless otherwise specified. Mulitple Diffuser Options ADP Curved Ribbed SDP Square Ribbed BLT Series LED BLT ADSM Curved Smooth SDSM Square Smooth ' x ' LED LED

ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: BLT L ADP EZ1 LP8 BLT Series Air function Lumens 1 Diffuser Voltage Driver Color temperature BLT X BLT (blank) Static A Air supply/ return Standard efficiency (>1 LPW) L L L High efficiency, (>1 LPW) LHE LHE 48LHE 48 ADP Curved, linear prisms ADSM Curved, smooth SDP Square, linear prisms SDSM Square, smooth Diffusers w/ trim rings ADPT Curved, linear prisms ADSMT Curved, smooth SDPT Square, linear prisms SDSMT Square, smooth (blank) MVOLT 1 1V V V 4 EZ1 SLD eldoled dims to 1% (-1 volt dimming) Step-level dimming LP8 LP8 LP8 LP8 LP9 LP9 LP9 LP9 8CRI, K 8CRI, K 8CRI, K 8CRI, K 9CRI, K 9CRI, K 9CRI, K 9CRI, K Controls Occupancy control Options (blank) N8 N8EMG N1 N1EMG No nlight nlight with 8% lumen management nlight with 8% lumen management For use with generator supply EM power 6 nlight without lumen management nlight without lumen management For use with generator supply EM power 6 (blank) No sensor control nlight Wired Networking NES nlight nes PIR integral occupancy sensor 8 NESPDT nlight nes PDT dual technology integral occupancy control 8 NESADCX nlight nes ADCX PIR integral occupancy sensor with automatic dimming photocell 8 NESPDTADCX nlight nes PDT dual technology integral occupancy sensor with automatic dimming photocell 8 Individual Control MSDADCX PIR integral occupancy sensor with automatic dimming control photocell,9 MSDPDTADCX PDT integral occupancy sensor with automatic dimming control photocell,9 ELL lumen battery pack 1 EL14L 1 lumen battery pack 1 CP Chicago plenum 11 BGTD Bodine Generator Transfer Device 1 PWS186 6 pre-wire, /8 diameter, 18 gauge, 1 circuit PWS18 6 pre-wire, /8 diameter, 18 gauge, circuit PWS18 PWSLV Two cables: one 6' pre-wire, /8 diameter, 18 gauge, circuits; one 6' pre-wire, /8 diameter, 18 gauge, purple and gray 1 PWS186LV 6 pre-wire, /8 diameter, 18 gauge, 1 circuit w/low voltage purple and grey wires 1 GLR Fast-blowing fuse 14 GMF Slow-blowing fuse 14 NPLT Narrow pallet RRL_ RELOC -ready luminaire 1 LATC Earthquake clip DWAM Anti-Microbial paint Non-Configurable BLT Configurations Stock/MTO Catalog Description * UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty Stock BLT L ADP LP8 8898198 18 K/8 CRI 1- BLT L ADP LP8 889819 K/8CRI 1- BLT L ADP EL14L LP8 8898 18 K/8CRI 1- BLT L EL14L LP8 889861 K/8CRI 1- MTO BLT L ADP LP8 88986984 18 K/8 CRI BLT L ADP LP8 889869 K/8CRI *-1V Dimming to 1%. Accessories next page Notes 1 Approximate lumen output. All versions may not achieve 1+ LPW. Refer to photometry on www.acuitybrands.com. High efficiency performance not avialable in AIR versions, 9 CRI or versions with integral sensor/trim rings. 4 Not available with SLD driver, ELL or EL14L battery packs. Not available with N8, N8EMG, N1 N1EMG or occupancy control. 6 nlight EMG option requires a connection to existing nlight network. Power is provided from a separate N8 or N1 enabled fixture. Must specify diffuser with trim rings. See sensor options on page. 8 Requires N8, N8EMG, N1, or N1EMG. 9 Only available with EZ1 driver option. -1v dimming wires not accessible via access plate. 1 When using pre-wire option, use PWS18. or PWS18 PWSLV. 11 Not available with N8, N8EMG, N1 or N1EMG. 1 Requires BSE labeling. Consult factory for options. 1 Not available with nlight wired network or individual controls. 14 Must specify voltage, 1 or with GLR & GMF fusing. 1 For ordering logic consult: RRL_1. LED: One Lithonia Way Conyers, GA 1 Phone: 8-88-6 Fax: -9-889 www.lithonia.com 16 Acuity Brands Lighting, Inc. All rights reserved. Rev. 4//16

Accessories: Order as separate catalog number. DGA Drywall grid adapter for x recessed fixture nlight Control Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight. WallPod stations Model number Occupancy sensors Model number On/Off npodm [color] Small motion, ceiling (PIR / dual tech) ncm 9 RJB / ncm PDT 9 RJB On/Off & raise/lower npodm DX [color] Large motion, ceiling (PIR / dual tech) ncm1 RJB / ncm PDT 1 RJB Graphic touchscreen npod GFX [color] Wall switch with raise/lower nwsx PDT LV DX [color] Photocell controls Model number Cat- cable (plenum rated) Model number Full range dimming ncm ADCX RJB 1' cable CAT 1FT J1 ' cable CAT FT J1 Replacement Parts: Order as separate catalog number. *LJR DBLT4 ADP LENS ASSEMBLY ft. replacement lens (light traps included) *LKH DBLT4 SDP LENS ASSEMBLY ft. replacement lens (light traps included) *LKY DBLT4 ADSM LENS ASSEMBLY ft. replacement lens (light traps included) *LL DBLT4 SDSM LENS ASSEMBLY ft. replacement lens (light traps included) *LT1 DBLT4 ADPT LENS ASSEMBLY ft. replacement lens (trims included) *LT DBLT4 SDPT LENS ASSEMBLY ft. replacement lens (trims included) *LT DBLT4 ADSMT LENS ASSEMBLY ft. replacement lens (trims included) *LT DBLT4 SDSMT LENS ASSEMBLY ft. replacement lens (trims included) *LT9 DBLT4 ADPT SENSOR LENS ASSEMBLY ft. replacement lens (trims included) *M4Y DBLT4 SDPT SENSOR LENS ASSEMBLY ft. replacement lens (trims included) *M DBLT4 ADSMT SENSOR LENS ASSEMBLY ft. replacement lens (trims included) *MH DBLT4 SDSMT SENSOR LENS ASSEMBLY ft. replacement lens (trims included) LED: One Lithonia Way Conyers, GA 1 Phone: 8-88-6 Fax: -9-889 www.lithonia.com 16 Acuity Brands Lighting, Inc. All rights reserved. Rev. 4//16

Option Automatic Dimming Photocell Sensor Options Occupancy Sensing PIR PDT nlight Wired Networking MSDADCX X X MSDPDTADCX X X NES X X NESADCX X X X NESPDT X X NESPDTADCX X X X Basic nlight Zone Integrated Sensor with Individual Control The MSDADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include, but not limited to, hallways, corridors, storage rooms, and breakrooms or other areas where people are typically moving. The MSDPDTADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include, but not limited to, open offices, private offices, classrooms, public restrooms, and conference rooms. Sequence of Operation nlight Wired Networking The nes is ideal for small rooms without obstructions or areas with primarily walking motion. Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the NESADCX includes an integrated photocell, which enables daylight harvesting controls. For areas like restrooms, private offices, open offices, conference rooms or any space with obstructions, the nes PDT dual technology sensor is recommended. The nes PDT utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the NESPDTADCX includes an integrated photocell, which enables daylight harvesting controls which is ideal for areas where windows are present. Sequence of Operation MAX MOTION NO MOTION MOTION MAX MOTION NO MOTION MOTION LIGHT LEVEL Occupants Detected In The Space Room Unoccupied Sensor Detects Motion LIGHT LEVEL Occupants Detected In The Space Room Unoccupied Sensor Detects Motion MIN 1. MIN TIME DELAY. MIN AT A 1% LEVEL LIGHTS OFF MIN. MIN TIME DELAY. MIN AT A 1% LEVEL LIGHTS OFF *The presetting on the automatic dimming photocell is fc. *The presetting on the automatic dimming photocell is fc. Sensor Coverage Pattern Mini Lens Recommended for walking motion detection from mounting heights between 8 ft (. m) and ft (6.1 m) Initial detection of walking motion along sensor axes at distances of x the mounting height up to 1 ft (4. m) and 1.x up to ft (6.1 m). Provides 1 ft (.66 m) radial detection of small motion when mounted at 9 ft (.4 m) Initial detection will occur earlier when walking across sensor s field of view than when walking directly at sensor 9 FT Mounting. 18 4.6 1. 1. 9 1.8 6.9 m ft.9 1.8 6. 9. 1 4.6 1. 18 LED: One Lithonia Way Conyers, GA 1 Phone: 8-88-6 Fax: -9-889 www.lithonia.com 16 Acuity Brands Lighting, Inc. All rights reserved. Rev. 4//16

PHOTOMETRICS BLT L ADP LP8, delivered lumens, test no. LTL918P4, tested in accordance to IESNA LM-9 18 8 1 9 9 8 CP Summary 9 1 6 8 9 4 1 14 94 88 6 4 1 4 8 1 9 891 68 1 9 14 Coefficients of Utilization pf % pc 8% % % pw %%% %%1% %%1% RCR 1 4 6 8 9 1 119 119 18 1 98 89 89 8 81 69 61 69 64 9 6 4 119 98 8 69 1 8 6 6 4 49 8 8 68 9 6 8 6 8 48 8 66 6 89 61 Zonal Lumen Summary Zone Lumens % Lamp % Fixture - - - - 9 9-18 - 18 8 18 4 4 BLT L ADP LP8, 41 delivered lumens, test no. LTL918P, tested in accordance to IESNA LM-9 18 8 1 1 1 9 9 8 CP Summary 9 1 6 8 9 1 19 14 14 1 849 6 4 1 14 1 194 118 11 89 6 6 191 Coefficients of Utilization pf % pc 8% % % pw %%% %%1% %%1% RCR 1 4 6 8 9 1 119 119 18 1 98 89 89 8 81 69 61 69 64 9 6 4 119 98 8 69 1 8 6 6 4 49 8 8 68 9 6 8 6 8 48 8 66 6 89 61 Zonal Lumen Summary Zone Lumens % Lamp % Fixture - - - - 9 9-18 - 18 11 199 69 411 411 Constant Lumen Management Enabled by the embedded nlight control, the BLT actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting. Without Lumen Management Energy is wasted and light level is inconsistent. 1% Wasted Energy LIGHT OUTPUT 8% 4W 1 THOUSAND OPERATING HOURS With Lumen Management Energy is saved and light level remains consistent. 1% 8% Saved Energy POWER INPUT 1 THOUSAND OPERATING HOURS W W 4W Performance Data Lumen Package Lumens Input Watts LPW L ADP LP8 1 11 L ADP LP8 1 11 L ADP LP8 61 L ADP LP8 11 L ADP LP8 16 L ADP LP8 18 L ADP LP8 L ADP LP8 6 L ADP LP8 16 L ADP LP8 49 18 L ADP LP8 4 L ADP LP8 14 AIR L ADP LP8 19 1 AIR L ADP LP8 1 AIR L ADP LP8 18 AIR L ADP LP8 1 19 AIR L ADP LP8 9 14 AIR L ADP LP8 1 1 AIR L ADP LP8 9 19 AIR L ADP LP8 6 11 AIR L ADP LP8 8 99 AIR L ADP LP8 19 11 AIR L ADP LP8 14 AIR L ADP LP8 14 HE Performance Data Lumen Package Lumens Input Watts LPW LHE ADP LP8 18 1 LHE ADP LP8 44 1 LHE ADP LP8 4 1 LHE ADP LP8 1 48LHE ADP LP8 99 1 48LHE ADP LP8 48 1 48LHE ADP LP8 4 1 48LHE ADP LP8 169 1 MOUNTING DATA Ceiling Type Exposed grid tee (1 and 9/16 ) G Concealed grid tee Plaster or plasterboard G* Appropriate Trim Type G 9/16 1/16 Screw Slot *DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 4-/4" x 4-/4" (Tolerance is +1/8", - ). LED: One Lithonia Way Conyers, GA 1 Phone: 8-88-6 Fax: -9-889 www.lithonia.com 16 Acuity Brands Lighting, Inc. All rights reserved. Rev. 4//16