COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Similar documents
COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

48PGD/E/F/L/M/N PG20-28

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

Principles of Mechanical Refrigeration

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM TFF COMBINATION HEATING/COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

PAR5. Product Specifications

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48TM GAS HEATING/ELECTRIC COOLING UNITS

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

48TF GAS HEATING/ ELECTRIC COOLING UNITS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Job Name Control Systems Description Date

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Appendix 13. Categories of Cooling and Heating systems

THE ULTIMATE ROOFTOP SOLUTION

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

Product Data. Fig. 1 - Unit 50VR -A

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

TECHNICAL SPECIFICATIONS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Submittal Data Performance Data Electrical Data

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

Model 655A Sizes

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

TECHNICAL SPECIFICATIONS

MODELS B1PA024, 030 AND 036

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

The ultimate fresh air solution.

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

RGE 13 A T - 1 A

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Direct Install Program Eligible Measures Listing:

RT-OA TM Rooftop Outdoor-Air (DOAS)

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

13 GEP A L P - 1 A

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

SECTION AIR-SOURCE UNITARY HEAT PUMPS

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Advanced Product Data

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Input Cap. (Btuh) Stage 2

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

CHAPTER 4. HVAC DELIVERY SYSTEMS

ENGINEERING. Edition No. 13 October 2002

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

Transcription:

COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume

Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are targeted at engineers and designers who wish to develop their knowledge in this field to effectively design, specify, sell or apply HVAC equipment in commercial applications. Although TDP topics have been developed as stand-alone modules, there are logical groupings of topics. The modules within each group begin at an introductory level and progress to advanced levels. The breadth of this offering allows for customization into a complete HVAC curriculum from a complete HVAC design course at an introductory-level or to an advancedlevel design course. Advanced-level modules assume prerequisite knowledge and do not review basic concepts. Constant volume packages rooftop units are one of the most common HVAC systems for commercial buildings. The reason for this is that these units provide cost effective, complete, preengineered air-conditioning systems with a large offering of options and accessories to adapt them to many commercial applications. In addition, the largest number of commercial buildings fall within the range covered by these units. Most HVAC designers will at sometime in their career find a rooftop unit is a good solution for a project. Even though the manufacturer fixes the selection of the internal components, the designer must have an understanding of their features, ratings, limits, options, application, and selection to properly select and apply them. This TDP module presents the basic information a designer needs to properly select and apply constant volume rooftops. This is the first of two TDP modules on rooftop units. The second module deals with Variable Volume rooftop units. Much of the information in this module can also be applied to the variable volume units. However, VAV units have a number of special design and application considerations that justify separate treatment. 2005 Carrier Corporation. All rights reserved. The information in this manual is offered as a general guide for the use of industry and consulting engineers in designing systems. Judgment is required for application of this information to specific installations and design applications. Carrier is not responsible for any uses made of this information and assumes no responsibility for the performance or desirability of any resulting system design. The information in this publication is subject to change without notice. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Carrier Corporation. Printed in Syracuse, NY CARRIER CORPORATION Carrier Parkway Syracuse, NY 13221, U.S.A.

Table of Contents Introduction... 1 What is a Rooftop Unit?... 2 Definitions and Descriptions...2 Packaged Air Conditioner (PAC)...3 Year-Round Air Conditioner (YAC)...3 Heat Pump (HP)...4 Discharge Air Configurations...4 Advantages and Disadvantages of Using Rooftops...5 Typical Rooftop Unit Markets...8 Rooftop Tier Offering... 10 Rooftop Equipment Components... 11 Compressors...11 Evaporator Coils...12 Coil Circuiting and Expansion Devices...13 Condenser Coils...14 Evaporator Fans...14 Evaporator Fan Motors...16 Condenser Fans...17 Safety Controls...17 Rating and Efficiency Terms... 19 Gross versus Net Capacity...19 EER...20 SEER...21 IPLV...22 COP...22 HSPF...23 Controlling the Rooftop Unit... 24 Programmable Thermostat...24 Communicating Thermostats...25 Direct Digital Control...25 DDC Networks...27 Sequence of Operation...28 Codes and Standards... 29 UL/ETL/CSA...29 ARI...29 ASHRAE...29 Indoor Air Quality and Sustainable Design (LEED TM )...30 Application Topics... 32 Normal Rooftop Unit Operating Conditions...32 Refrigerants...33 Controlling Room Humidity...34 Supply Air Reheat Dehumidification Options...35 Reheat and ASHRAE 90.1 Impact...37 Pretreating Outside Ventilation Air...37 Air-to-Air Energy Recovery...38 Energy Recovery Device Using Mechanical Refrigeration Cycle...38 Dehumidification Combined with an Energy Recovery Device...40 Demand Controlled Ventilation for IAQ...41 Heat Pump versus Gas versus Electric heat...44 Minimum Entering Temperatures to Gas Heat Exchanger...45 Additional Placement Considerations for Rooftop Products...45 Clearances...46 Visual Considerations...47 Support for the Unit...48 Sound Considerations...48 Installation Considerations for Gas Heat Rooftop Units...48

Electrical Data... 49 Minimum Circuit Amps (MCA)... 49 Maximum Over-Current Protection (MOCP)... 50 Recommended Overcurrent Protection (ROCP)... 50 Disconnects... 50 Sizing the Disconnect:... 51 Location of Disconnects... 51 Types of Overcurrent Protection... 52 Single-Point Power... 52 Replacement Rooftop Considerations... 53 Options and Accessories... 56 Economizers... 56 When to Use an Economizer... 57 Economizer Control Methods... 57 A, B, C, and D Scale Economizer Settings... 59 Manual Outdoor Air Damper... 60 Motorized Two-Position Outdoor Air Damper... 60 Barometric Relief Dampers... 61 Powered Exhaust... 61 Smoke Control... 62 Corrosion-Resistant Coil Options... 63 Standard Coil Construction... 63 Pre-Coated Aluminum-Fin Coils... 64 Copper-Fin Coils... 64 Electro-Coated Coils... 65 Coil Guards... 65 Low Ambient Cooling Operation... 66 Heating Options... 67 Gas... 67 LP Gas Versus Natural Gas... 68 Altitude Adjustment Gas Heating... 68 Gas Emission Restrictions (Low NO x )... 69 Electric Heat... 69 Hot Gas Bypass... 70 Field-Installed VFD for Constant Volume Rooftop Unit... 71 Convenience Outlets... 71 Roof Curbs... 72 Roof Curb Types... 72 Roof Curb Alignment... 75 Roof Curb Installation... 75 Adapter Roof Curb Installation... 76 Roof Curb and Electric Heat Requirements... 77 Thru-the-Curb Utilities... 77 Rooftop Unit Sound... 78 Sound Mitigation Suggestions... 79 Existing Installations... 79 Variable Volume and Temperature (VVT)... 80 Selecting Rooftop Equipment... 81 Standard ARI Rating Conditions... 81 Typical Rooftop Unit Published Ratings... 82 Rooftop Unit Selection Example: Gas Heating (YAC)... 82 Summary... 88 Work Session... 89 Appendix... 91 References... 91 Work Session Answers... 93

ROOFTOP UNITS, LEVEL 1: CONSTANT VOLUME Introduction Packaged constant volume rooftop units are one of the largest and most important segments of the air-conditioning industry, primarily due to their all-inclusive design, low cost, application flexibility, ease of installation, and widespread use. This TDP module will give you an understanding of the types of constant volume rooftops, their application, available options and accessories, and guidelines for their use and installation. The function of commercial packaged rooftop equipment is to provide complete air conditioning, including control of temperature, humidity, air circulation, exhaust, energy recovery, and filtration. Although standard rooftop units do not directly control relative humidity in most cases, they dehumidify the air, which usually results in acceptable humidity levels. While all rooftop units provide mechanical cooling, some are equipped with a gas-heating system while others use electric heaters, steam or hot Figure 1 water coils to provide year-round control of 2-25 Ton Constant Volume Rooftop Units temperature. Packaged rooftop units are the largest segment of products called packaged equipment, and account for almost one-half of the total commercial unitary market. The complete air conditioner is contained in one package, ranging in size from 1.5 to over 105 tons cooling capacity. Packaged rooftop units are generally available in sizes from 1½ tons to over 100 tons of cooling capacity. Two types of airflow control are available within this tonnage range: constant volume, in which the volume of air is constant and the air temperature is modulated to match cooling load requirements, an variable volume, in which the temperature is constant and the volume of air is modulated. While much of the construction of these two unit types is the same, there are several special construction features necessary in variable volume units. Generally, units under 20 tons tend to be constant volume type and units over 30 tons tend to be variable volume. However, much smaller units are available as variable volume and units to over 100 tons are used in constant volume applications. This TDP module covers primarily 2 to 25 ton constant volume (CV) commercial rooftop air conditioners. Units five ton and smaller are sometimes used for residential applications due to the special requirements of residential units, this application is not covered in this TDP. A separate TDP module covers variable volume rooftops from 20 tons and above. Much of the material in this module can be applied to larger tonnage constant volume units as well. Commercial HVAC Equipment 1

ROOFTOP UNITS, LEVEL 1: CONSTANT VOLUME What is a Rooftop Unit? The term packaged is defined as products that fall within the unitary air conditioner category as defined by the Air Conditioning and Refrigeration Institute (ARI). ARI states that a unitary air conditioner consists of one or more factory-made assemblies that normally include: an evaporator or cooling coil, evaporator fan, compressor, and condenser combination. (It may include a heating function as well.) When these components are integrated into one cabinet, they are single packaged units. When provided in separate assemblies and designed to be used together, they are split systems. Since these units are most often placed on the roof, single package units are commonly called rooftop units. However, they also can be slab-mounted on the ground. They are usually available with either vertical or horizontal supply and return air connections. On a typical rooftop unit, the compressor(s) are located at one end and the condenser coils are wrapped around or in close proximity to them. Filters are positioned on the entering airside of the evaporator coil. These are typically one or two-inch throw-away filters. Figure 2 shows a gas-fired rooftop unit so the flue gas exhaust fan and its discharge are shown. The unit controls are located in an electrical compartment. The gas heat exchanger is located in a separate section on the downstream side of the evaporator fan. A perimeter base rail assembly is used to support the unit when placed on its curb (not shown) and to handle and rig the unit. The evaporator coil is two, three, or four rows deep and is a draw-thru design in front of the indoor fan which discharges air into the heater then down the supply duct. Directdrive propeller fans draw outside Figure 2 air across the condenser coils and discharge the warmed air upwards. Components of a Typical Rooftop Rooftop units are designed, tested and certified with national safety certification agencies such as Underwriter s Laboratories (UL), Electrical Testing Laboratories (ETL), and Canadian Safety Agency (CSA.). Definitions and Descriptions ARI categorizes packaged rooftop units by the ability to provide heating. These categories are single packaged air conditioner (SP-A), single packaged year-round air conditioner (SPY-A), and single packaged heat pump (HSP-A). In this text we will use three commonly accepted acronyms for these units. SP-A will be referred to as PAC, SPY-A as YAC (with gas heat), and HSP-A as HP. 2 Commercial HVAC Equipment

ROOFTOP UNITS, LEVEL 1: CONSTANT VOLUME Packaged Air Conditioner (PAC) A PAC is a packaged air conditioner (rooftop unit) that provides cooling only, or cooling with other than gas heat. The primary function of the PAC is cooling. Electric heaters are typically available factory installed as an accessory for field installation. Sometimes, PACs are called all electric or electric-electric because the source of heat is usually an electric resistance coil. Steam or hot water coils are offered as accessories by some manufacturers, and the rooftop unit is still referred to as a PAC. That is because the PAC unit does not have gas heat. Figure 3 Packaged Air Conditioner (PAC) No Gas Heat Year-Round Air Conditioner (YAC) A YAC is a packaged unit with a gas heating section. It is called year-round because heating and cooling are integral factory-installed unit functions. Gas heating sections are normally designed for natural gas, but propane models or propane conversion kits are typically available. Note: A YAC is also known as a gas-electric unit. Figure 4 Rooftop Year Round Air Conditioner (YAC) Contains Gas Heat Commercial HVAC Equipment 3

ROOFTOP UNITS, LEVEL 1: CONSTANT VOLUME Heat Pump (HP) A heat pump rooftop unit looks just like a PAC from the outside but the mechanical refrigeration cycle inside is different. The refrigeration cycle provides both cooling and reverse cycle heating. In the heating mode, the refrigerant flow is reversed using a four-way valve so that heat is extracted from the outdoor air and transferred to the indoor air. The heat pump is not just a PAC with a fourway valve, however. The evaporator and condenser are larger and the metering device arrangement is different to allow for the dual role. Because the heat pump does not heat efficiently at very low outdoor temperatures and to provide heating during defrost, the Figure 5 unit often contains optional electric Heat Pump Refrigeration Cycle in Rooftop Unit Cooling Mode heaters that supplement the reverse cycle heat. Discharge Air Configurations Shown is a vertical, or down supply air discharge as well as a vertical return configuration. Next to it is a horizontal discharge and return configuration. If the unit features both vertical supply and return and horizontal supply and return it is referred to as a convertible design. For vertical discharge the ductwork that delivers the conditioned airflow from the rooftop unit to the space and returns the air back to the rooftop should be attached to the curb and NOT the rooftop. The unit is simply placed on top of the curb using a crane or helicopter. The curb is a sheet metal platform that supports the unit. Figure 6 Rooftop Discharge Air Configurations Many rooftop designs offer horizontal supply and return duct connections in addition to vertical. Many of these designs are installed on grade (ground level) on a concrete slab. 4 Commercial HVAC Equipment