SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Similar documents
SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

ADDITIONAL INFORMATION

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

THERMAL MANAGEMENT SOLUTIONS

FreezGard. Self-regulating crankcase heater. Product Overview

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

THERMAL MANAGEMENT SOLUTIONS

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

NGC-40 Advanced Heat-Tracing Control System

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

ROOF ICE MELT (RIM) SYSTEM

IceStop System Installation and Operation Manual

ROOF ICE MELT (RIM2) SYSTEM

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

SAFETY INFORMATION AND WARNINGS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

PROJECT MANAGEMENT Transmittal No 17D

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

910 Series Single-point heat-tracing control system

Warranty Info: ETI s warranty policy can be viewed at:

Dual-point heat-tracing control system

Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Roof and Gutter De-Icing

DESCRIPTION. 42 mm. 125 mm

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

HTC-915-CONT. Heat-Trace Control system

XL-Trace System Application and Design Guide

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Freezer Frost Heave Prevention

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

Surface Snow Melting and. Icing ElectroMelt. Introduction. ElectroMelt Self-Regulating Heating Cable System

C910 Series. Single-point heat-tracing control system

Gardian W51. Approvals

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Longline Heating. Contents. Introduction

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

PART GENERAL 1.01 SECTION INCLUDES

SC-40 Satellite Contactor

Model GIT 4 Gutter Snow and Ice Melting Control

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

FTC-HST WARNING: CAUTION:

Skin-Effect Heat-Tracing System (STS)

FPC-02 Series. Installation and Operating manual

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Frost Heave Protection System Installation and Operation Manual

PYROSELF Innovative Snow Sensor and Controller for 2 x 24A loads outputs. Installation and Operating manual

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

PLSRR Heat Trace Cable Data Sheet

RAYCHEM NGC-30 COMPONENTS

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES. thermal ManaGeMent.

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

ACS-30-EU-EMDR- 10-MOD

For Raychem ACS-30 Controls Systems

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

XL-Trace System Installation and Operation Manual

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Sensor Interface Module Installation/Operation Instructions

RayClic Connection System

ACCS-30. Multipoint commercial heat-tracing control system

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

CN7232 Advanced Garage Ventilation Controller

WATLOW IND. Thermostat Control Installation & Maintenance Manual I&M NUMBER

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION ISOLATED POWER SYSTEMS

ACS-30-EU-VIA-DU-20-MOD

Transcription:

SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only) G R Heater thermostat (3R only) Door lock handle G Alarm acknowledge C.B. tripped alarm PRODUCT OVERVIEW The Raychem SMPG3 is a three-phase power distribution panel for three-phase heating cables that includes ground-fault protection, monitoring and control for snow melting or roof and gutter de-icing systems. The ETI EUR-5A snow melting and gutter de-icing controller is included with the SMPG. When used with one or more compatible sensors, the EUR-5A automatically controls surface snow melting and roof and gutter de-icing heating cables for minimum energy costs. Applications include pavement, sidewalk, loading dock, roof, gutter, and down spout snow/ice melting in commercial and industrial environments. The adjustable hold-on timer continues heater operation for up to 10 hours after snow stops to ensure complete melting. Snow/Ice melt controller Control wiring EUR - 5A Exterior View GFS1 CB1 Control power transformer PDB GFS2 CB2 Interior View GFS3 HTC CB3 Ground bar Main breaker (optional) Power distribution block Ground-fault sensors Heat trace Branch breakers (3 pole) The calibrated 40 F to 90 F (4 C to 32 C) high limit slab sensor prevents excessive temperatures when using constant wattage and MI heating cables. It also permits safe testing at outdoor temperatures too high for continuous heater operation. The temperature sensor is included. The EUR-5A provides a complete interface for use in environments supervised by an energy management computer (EMC). This feature can also be used for general purpose remote control and annunciation. All sensor and communications wiring is NEC Class 2. This simplifies installation while enhancing fire and shock safety. Multiple sensors provide superior performance by better matching the controller to site performance requirements. The EUR- 5A can interface up to six sensors. For single-phase heating cable configurations, refer to the SMPG1 data sheet (H57680). For additional information on three-phase snow melting designs, contact your Thermal Management representative. 1 / 6

SMPG3 Ambient operating temperature Indoor installation (NEMA 1/12): 14 F ( 10 C) to 122 F (50 C) Outdoor installation (NEMA 3R/4): 40 F ( 40 C) to 122 F (50 C) (Includes space heater and thermostat) Main Main circuit (15 150 A) 3-pole breaker (optional) (150 200 A) 3-pole Operating heating cable voltage Branch ground-fault breaker Circuit breaker rating Field wire size (Copper wires) APPROVALS 3-pole 100 A or 200 A Square D type HDL (Installed in panel when ordered/needed) Square D type JDL (Installed in panel when ordered/needed) 208, 480, or 600 V, three phase Square D type QOB-1021 (15A 100 A) for 208 V Square D type HDL-1021 (15A 150 A) for 600 V JDL-1021 (160 200) (All the above are Shunt trip C.B. with external ground-fault sensor) 15 150 A #12 8 AWG (15 30 A C.B.), #8 2 AWG (40 50 A C.B.), #6 1/0 AWG (60 100 A C.B.), #1/0 AWG 350 kcmil (150 A C.B.) To comply with NEC Article 427-55(a), all circuit breakers are equipped with the means for lockout in the Off position. UL STD. 508A CAN/CSA C22.2 NO. 14 GROUND-FAULT PROTECTION To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Thermal Management, agency certifications, and national electrical codes, ground-fault equipment protection must be used on each heating cable branch circuit. Arcing may not be stopped by conventional circuit protection. Many Raychem control and monitoring systems meet the ground-fault protection requirement. SMPG3 SNOW MELTING AND ROOF AND GUTTER DE-ICING CONTROL SCHEMATIC Main circuit breaker (optional) N Incoming power Remote annunciation alarm (circuit breaker with alarm type #3) Three-pole main Fuse Control transformer 24 V EUR-5A SNOW SWITCH AUTOMATIC SNOW/ICE MELTING CONTROL PANEL SUPPLY SNOW/ICE HEATER HEATER CYCLE 2 0 55 F 50 F 45 F 4 6 HOURS 8 10 60 F 65 F 70 F 85 F 75 F 80 F TEMPERATURE GIT-1 CIT-1 SIT-6E Slab temperature sensor Gutter ice sensor Aerial snow sensor Pavement-mounted sensor Three-pole circuit breaker with shunt trip/external ground-fault sensor To ground-fault module Junction box A1 B1 Current transformers Ground A B C C1 Heating cables 3 Ø Delta connected heating cables Three-pole circuit breaker with shunt trip/external ground-fault sensor To ground-fault module Junction box Heating cables Junction box Current transformers Ground Terminal block 3 Ø Wye connected heating cables 2 / 6

CATALOG NUMBER SMPG3 comes in a variety of configurations. The following chart outlines the elements that constitute a configuration and the corresponding catalog number. If standard configurations do not meet your needs, custom SMPG panels are available and processed under the catalog number SMPG-GENERAL, part number P000000763. Please contact your Thermal Management representative for a custom SMPG panel quotation. Non-standard configurations will carry ETL Certification, not a UL Listing. SMPG3 Voltage Circuit breaker type Number of circuit breakers/number of poles (rating) Enclosure Contactor size SMPG3 208 3 2/3P (80) 3R 200 Options: (MCB) Voltage 208 V (Three phase) 480 V (Three phase) 600 V (Three phase) Circuit breaker type 3 = 3-pole circuit breaker w/shunt trip and external ground-fault sensor - with alarm *Number of circuit breakers/ Number of poles (circuit breaker rating) 208 V (3 pole) 480 V or 600 V (3 pole) # of Available # of Available C.B. C.B. ratings (A) C.B. C.B. ratings (A) 1 15 100 1 15 100 2 15 150 2 15 150 3 15 150 3 15 150 Main Circuit Breaker MCB = Optional Main Circuit Breaker Included Contactor Size Contactor # of Breakers size (A) breakers size (A) 100 1 25, 30, 40, 50, 60, 70, 80, 100 200 1 150 100 2 25, 30, 40, 50 200 2 60, 70, 80, 100 100 3 25, 30 200 3 40, 50, 60 Enclosure 1/12 = NEMA 1/12 (indoors) 3R/4 = NEMA 3R/4 (outdoors) *Warning: Confirm the total load (A) does not exceed rating. EUR-5A Supply voltage/max current Control transformer Operating temperature Hold on time adjustment High temperature limit adjustment Moisture/temperature sensors Ambient temperature sensor Remote interface Building/energy management computer interface 21 to 28 Vac/2 A Included 40 F ( 40 C) to 140 F (60 C) 0 to 10 hours 40 F (4 C) to 90 F (32 C) Up to six can be used simultaneously. Members of the CIT-1/GIT-1/SIT-6E family in any combination. Locate up to 2,000 ft (609.6 m) for EUR-5A. Included RCU-3 Remote Control Unit (can operate up to 500 ft [152 m] from panel) 5 Vdc @ 10 ma MAIN CIRCUIT BREAKERS Installed in Control Panel MCB rating Voltage Catalog number Part number 50 A 120 600 V HDL36050 T1010097 100 A 120 600 V HDL36100 T1010101 110 A 120 600 V HDL36110 T1010102 125 A 120 600 V HDL36125 T1009792 150 A 120 600 V HDL36150 T1010087 175 A 120 600 V JDL36175 T1010053 200 A 120 600 V JDL36200 T1010103 225 A 120 600 V JDL36225 T1009945 250 A 480 or 600 V JDL36250 T1010104 3 / 6

POWER DISTRIBUTION Catalog Number Part Number Description SMPG3 Snow Melting and De-Icing Power Distribution and Control Panel - NEMA 1/12 208 V 3-pole NEMA 1/12 Enclosure SMPG3-208-3-1/3P(XX)-1-100 P000000476 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-208-3-1/3P(XX)-1-200 P000000477 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-208-3-2/3P(XX)-1-100 P000000478 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-208-3-2/3P(XX)-1-200 P000000479 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-208-3-3/3P(XX)-1-100 P000001381 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-208-3-3/3P(XX)-1-200 P000000480 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A 480 V 3-pole NEMA 1/12 Enclosure SMPG3-480-3-1/3P(XX)-1-100 P000000481 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-480-3-1/3P(XX)-1-200 P000001382 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-480-3-2/3P(XX)-1-100 P000000482 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-480-3-2/3P(XX)-1-200 P000000483 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-480-3-3/3P(XX)-1-100 P000001383 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-480-3-3/3P(XX)-1-200 P000000484 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A 600 V 3-pole NEMA 1/12 Enclosure SMPG3-600-3-1/3P(XX)-1-100 P000000494 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-600-3-1/3P(XX)-1-200 P000001384 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-600-3-2/3P(XX)-1-100 P000000495 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-600-3-2/3P(XX)-1-200 P000000496 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-600-3-3/3P(XX)-1-100 P000000497 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-600-3-3/3P(XX)-1-200 P000000498 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A 4 / 6

POWER DISTRIBUTION Catalog Number Part Number Description SMPG3 Snow Melting and De-Icing Power Distribution and Control Panel - NEMA 3R/4 208 V 3-pole NEMA 3R/4 Enclosure SMPG3-208-3-1/3P(XX)-3R-100 P000000485 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-208-3-1/3P(XX)-3R-200 P000000486 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-208-3-2/3P(XX)-3R-100 P000000487 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-208-3-2/3P(XX)-3R-200 P000000488 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-208-3-3/3P(XX)-3R-100 P000001385 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-208-3-3/3P(XX)-3R-200 P000000489 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A 480 V 3-pole NEMA 3R/4 Enclosure SMPG3-480-3-1/3P(XX)-3R-100 P000000490 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-480-3-1/3P(XX)-3R-200 P000001386 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-480-3-2/3P(XX)-3R-100 P000000491 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-480-3-2/3P(XX)-3R-200 P000000492 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-480-3-3/3P(XX)-3R-100 P000001387 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-480-3-3/3P(XX)-3R-200 P000000493 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A 600 V 3-pole NEMA 3R/4 Enclosure SMPG3-600-3-1/3P(XX)-3R-100 P000000499 SMPG with (1) 15 100 A breaker, GF sensor with alarm, 100 A SMPG3-600-3-1/3P(XX)-3R-200 P000001388 SMPG with (1) 15 150 A breaker, GF sensor with alarm, 200 A SMPG3-600-3-2/3P(XX)-3R-100 P000000500 SMPG with (2) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-600-3-2/3P(XX)-3R-200 P000000501 SMPG with (2) 15 150 A breakers, GF sensor with alarm, 200 A SMPG3-600-3-3/3P(XX)-3R-100 P000000502 SMPG with (3) 15 100 A breakers, GF sensor with alarm, 100 A SMPG3-600-3-3/3P(XX)-3R-200 P000000503 SMPG with (3) 15 150 A breakers, GF sensor with alarm, 200 A ACCESSORIES ETI sensors Catalog number Part number Pavement-mounted sensor SIT-6E P000000112 Aerial snow sensor CIT-1 512289 Gutter ice sensor GIT-1 126795 Replacement controller Snow melting and gutter de-icing controller EUR-5A T0001527 5 / 6

WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com Pentair is owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2006 2017 Pentair. 6 / 6