Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Similar documents
Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SECTION Fluorescent Dissolved Oxygen Measuring System

UDA2182 Universal Dual Analyzer

Steam and Water Analysers

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

UDA2182 Universal Dual Analyzer

AS950 REFRIGERATED SAMPLERS

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

AS950 PORTABLE SAMPLERS

Model Q45P/R. ph/orp Monitor...

Free Chlorine Measuring System

Process Alarm Module RTA 421

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Dissolved Oxygen Measurement liquisys M COM 223 / 253

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Figure 1 DirectLine DL423 Sensor. Description, continued

Model Q45P/R. ph/orp Monitor...

Multi-Gas-Controller MGC2

Figure 1 DirectLine DL423 Sensor. Description, continued

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Oxygen (O2) Single-Point Gas Detection System

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

LC1350 Level Controller

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

High Pressure Conductivity Monitor

Dual Input ph/orp Analyzer

Model D12-IR. Digital Gas Transmitter...

Series 5000 Hydrazine Analyzer Model 60002

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

UDA2182 Universal Dual Analyzer Specifications

Dual Input ph/conductivity Analyzer

SECTION Free/Available Chlorine Analysis System

Toxic Gas Detection. Model F12. Toxic Gas Detection

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger Polytron 8000 Stationary gas detector (EC)

Two-Channel Gas Controller

Instruction Manual PN OZ/rev.K February Model SOLU COMP Ozone Analyzer

Instruction Manual PN pH/rev.M February Model Solu Comp II. Dual Input ph Analyzer. Model Options and

Bionics Instrument. Alarm Handling. Gas Alarm Systems

BC3250. Blowdown Controller

PolyGard 2-channel Gas Controller MGC-03

Dual Input Toroidal Analyzer

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

WASTEWATER Online UV%Transmission Analyzer

Hydrazine Analyzer Series 2171 Specifications

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Nov 08 PRODUCT SPECIFICATION SHEET

Concise catalogue Water-Industry

UDC 700 Universal Digital Controllers and Indicator Specifications

Mark 25 Ultrapure Water Conductivity Analyzer

UDC100 Universal Digital Controller Specifications

Low Temperature Zirconia Oxygen Analyzer

IGD.CO.UK

HIGH CAPACITY PRODUCT LINE

SECTION ph/orp Sensors

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Industrial Grade Gas Detection Detecting The Difference

Carbon Monoxide Transmitter

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Model 144H. Product Data Sheet , Rev DB February Content

Pioneer-R16 Gas Monitor Operator s Manual

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

HIGH CAPACITY PRODUCT LINE

Temperature Controllers

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

MEAS CAL ALARM WASH CONF APT4000 TC

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Dissolved Oxygen Measurement liquisys S COM 223 / 253

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

VA301C CONTROLLER WITH BACnet OPTION

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

/8 DIN Level Indicator

Dräger Polytron 7000 Fixed gas detector

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

Controllers. Instruction Manual WARNING

Inductive Conductivity

Operating Instructions. For. Alarm Control Module. Model SSR 500

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

Power Flame Incorporated

Dräger Polytron 5100 EC Detection of toxic gases and vapors

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Transcription:

Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based sensor controller. B. Change digital sensors connected to the controller by unplugging and plugging in sensors as necessary. C. Change analog sensor modules connected to the controller by unplugging and plugging analog sensor modules as necessary. D. The controller accepts 4 different analog sensor modules in any combination to measure the following: 1. ph/orp module a. Combination ph/orp 2. Conductivity module a. Contacting conductivity b. Inductive conductivity c. Cationic conductivity (Calculated ph) 3. Dissolved Oxygen/Oxygen Scavengers module a. Amperometric dissolved oxygen b. Amperometric oxygen scavengers 4. Analog ma IN module 1.3 Alternates A. Parameter-specific controllers that do not allow changing parameter configurations in the field are unacceptable. 1.4 System Description A. Performance Requirements B. ph/orp sensor module a. ph: -2.0 to +14.0 or -2.00 to 14.00 ph b. mv: -2100 to +2100 mv 2. Repeatability: 0.1% of range or better 3. Response time (t90%): 0.5 s 4. Temperature range: a. PT100/PT1000: -20 to 200 C b. Accuracy: ±0.05 C C. DO sensor module a. 0 to 2000 ppb 2. Repeatability: ±0.5 ppb or ± 5% whichever is greater 3. Response time (t90%) for step change between 1-40 ppb: <30s 4. Temperature range: 0-45 C (32-113 F)

Project Name Page 2 D. Oxygen Scavengers sensor module a. 0 to 500 ppb of dissolved N 2 H 4 b. 0 to 100 ppb of carbohydrazide c. Repeatability: <2% of the measured value or < 1ppb, whichever is greater d. Response time (t90%): < 60 seconds e. Temperature range: 5-45 C (41-113 F) E. Contacting conductivity sensor module a. Conductivity: 0-20,000 S/cm b. Resistivity: 0-50 Ω cm c. TDS: 0-9999 ppm or 0-9999 ppb 2. Repeatability: a. ±1% of reading or 0.002 µs/cm below 0.2 µs/cm, whichever is higher 3. Response time (t90%): 0.5 s 4. Temperature range: -20 to 200 C a. Accuracy: ±0.05 C F. Inductive conductivity sensor module a. Conductivity: 0.5-10,000 ms/cm b. % concentration: 0-99.99 or 0-200.0% c. TDS: 0-9999 ppm 2. Repeatability: a. 0.5-10,000 ms/cm: ± 2% 3. Response time (t90%): 1 s 4. Temperature range: -2 to 200 C a. Accuracy: ±0.05 C 1.5 Certifications A. EMC: CE compliant for conducted and radiated emissions CISPR 11 (Class A limits), EMC Immunity EN 61326-1 (Industrial limits) B. Safety: General Purpose UL/CSA 61010-1 with cetlus safety mark C. Australian C-TICK and Korean KC Markings 1.6 Environmental Requirements A. Operational Criteria 1. Temperature: -4.0 to 140.0 F (-20.0 to 60.0 C) 2. Relative humidity: 0 to 95%, non-condensing 1.7 Warranty A. Warranted for two years from date of shipment from manufacturer defects. 1.8 Maintenance Service A. Clean controller keypad B. Calibrate ma output signals

Project Name Page 3 PART 2 PRODUCTS 2.1 Manufacturer A. Hach Company, Loveland, Colorado and Hach Lange GmbH, Berlin, Germany 1. Hach model sc200 Controller 2.2 Manufactured Unit A. The controller is available with the following power requirements: 1. AC powered: 100 to 240 Vac ±10%, 50/60 Hz; 15 W with 7 W sensor/network card load, 37 W with 25 W sensor/network card load. 2. 24 VDC powered: 24 VDC, -15%, +20%; 16 W with 7 W sensor/network card load, 34 W with 25 W sensor/network card load (optional Modbus RS232/RS485 and Profibus DPV1 network connection). B. The controller uses a menu-driven operation system. C. The controller display is graphic dot matrix LCD with LED backlighting. D. The controller is equipped with a real-time clock. E. The controller is equipped with two security levels. F. The controller is equipped with a data logger with RS-232 capability. G. The controller shall have worded operation menus in 19 languages. H. The controller is equipped with an SD card reader for data download and controller software upload. I. Four electromechanical, UL rated, SPDT relays (Form C) are provided for user-configurable contacts rated 100 to 230 Vac, 5 Amp at 30 VDC resistive maximum. 1. The following can be programmed: a. Alarm b. Warning c. Timer/scheduled cleaning d. Feeder control e. Event control f. Pulse width modulation g. Frequency modulation 2. The following can be assigned: a. Primary value measurement I b. Secondary value measurement I c. Tertiary value measurement I d. Quaternary value measurement I e. Primary value Measurement II f. Secondary value measurement II g. Tertiary value measurement II h. Quaternary value measurement II i. Real time clock j. Calculated values J. Two analog 0/4-20 ma outputs are provided with a maximum impedance of 500 ohms. 1. The controller can be equipped with three additional 4-20 ma outputs with a maximum impedance of 500 ohms. 2. The following can be programmed: a. Alarms: 1) Low alarm point

Project Name Page 4 2) Low alarm point deadband 3) High alarm point 4) High alarm point deadband 5) Off delay 6) On delay b. Controls: 1) Linear 1) Bi-linear 2) Logarithmic 3) PID 1. The following can be assigned: a. Primary value measurement I b. Secondary value measurement I c. Tertiary value measurement I d. Quaternary value measurement I e. Primary value measurement II f. Secondary value measurement II g. Tertiary value measurement II h. Quaternary value measurement II i. Calculated values K. The controller can be equipped with the following forms of communication: 1. MODBUS RS-232 2. MODBUS RS-485 3. Profibus DP L. All user settings of the controller are retained for 10 years in flash memory. M. The controller is equipped with a system check for: 1. Power up test (monitoring and shutdown) 2. Total power draw 3. Memory devices 4. Temperature mother board N. The controller has the option of graphical measurement that tracks measurement values over time. 2.3 Equipment A. Materials 1. Housing: polycarbonate, aluminum (powder coated), and stainless steel 2. Rating: NEMA 4X enclosure, rated IP66 B. Conduit openings: 0.5 in. NPT 2.4 Components A. Standard equipment 1. Controller 2. Mounting hardware for wall, pipe, and panel mounting B. Dimensions: 144 x 144 x 180 mm (5.7 x 5.7 x 7.1 in.) C. Weight: 1.6 kg (3.5 lbs.)

Project Name Page 5 2.5 Accessories A. Weather protection shield B. Sun screen C. RS-232 / RS-485 MODBUS output card D. PROFIBUS DP output card E. HART output card F. Additional ma input card G. Additional ma output card PART 3 EXECUTION 3.1 Preparation A. The sensor may need to be installed with additional accessories depending on its application. 1. Mount on rail, panel, pipe, or wall. 2. Sensor to analyzer distance: 300 m (985 ft.) 3.2 Installation A. Contractor will install the analyzer in strict accordance with the manufacturer s instructions and recommendation. B. Manufacturer s representative will include a half-day of start-up service by a factory-trained technician, if requested. 1. Contractor will schedule a date and time for start-up. 2. Contractor will require the following people to be present during the start-up procedure. a. General contractor b. Electrical contractor c. Hach Company factory trained representative d. Owner s personnel e. Engineer 3.3 Manufacturer s Service and Start-Up A. Contractor will include the manufacturer s services to perform start-up on instrument to include basic operational training and certification of performance of the instrument. B. Contractor will include a manufacturer s Service Agreement that covers all the manufacturer s recommended preventative maintenance, regularly scheduled calibration and any necessary repairs beginning from the time of equipment startup through to end user acceptance / plant turnover and the first 12 months of end-user operation post turnover. C. Items A and B are to be performed by manufacturer s factory-trained service personnel. Field service and factory repair by personnel not employed by the manufacturer is not allowed. D. Use of manufacturer s service parts and reagents is required. Third-party parts and reagents are not approved for use. END OF SECTION