HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

Similar documents
RE-PR3-E-27 3-Phase Panel Mount 27kW

Electrisaver User and Installation Instructions

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Condensate FreeFlo. Condensate FreeFlo. Homeowner Guide. Installation Guide. Indicator Light. Running Costs. Product Overview

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

NXM2G Installation and Operating Manual

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

ACS-30-EU-EMDR- 10-MOD

10yr O2NE & Safe-Ox. User Manual

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

The next generation thermometer from the global leader

18W Round LED Wall/Ceiling Light with Microwave Sensor

Frost Protection Thermostat

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Installation and Wiring Instructions

Smoke Vent Control Panel PCB4 V4 Installation Manual

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

, ,

Electronic timeswitch

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

LC3000 Level Controller Installation and Maintenance Instructions

LEAKSTOPPER RANGE Multizone water leak detection systems

Main switch current K: with main switch (optional)

DOL 31 Speed Controller Technical User Guide

Semi flush-mount room thermostats

Electronic 7 Installation Instructions

Popcorn Warmer Cabinet

12W Round LED Wall/Ceiling Light with Microwave Sensor

Excellence in Level Measurement

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Inductive slot sensor

DESIGN GUIDELINES. THERMAL building SOLUTIONS

14300 MAINS SEPARATOR ALARM MANUAL

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

Door Release Power Supply

Smoke Fire Damper Interface (230V)

ET10 Series Stand-alone LCD Fan Coil Thermostat

KHM800 Professional 800w haze machine

Room thermostats with LCD RDD100..

Labkotec Ice Detector

FH3HT. 3Kw HIGH TEMPERATURE ELECTRIC FAN HEATER PRODUCT MANUAL

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

JDDT1 - Single Stage Digital Thermostat

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

the next generation thermometer from the global leader

Room thermostat with 24-hour time switch and large LCD

230v Dial Thermostat Instruction Manual

Operation and Maintenance Manual

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

LPC3BSP65 & LPC3BDP65

Frost Units for air temperature monitoring

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Operating Instructions

Training, Assessment, Consultants for Hazardous & Industrial Areas

IT system floor-standing distribution

Wireless room thermostat with LCD

Instructions for the fan motor control system, SILVER C

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

UV Flame Supervision System

Installation, operating and servicing instructions

Instruction FH-CWP Thermostat

MC 31 Speed Controller Technical User Guide Code no GB

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Fire Damper Interface (230V)

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

Smoke Damper Interface (230V)

Snifter ATEX22 VERSION. User Manual. Distributor

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

HEA USER MANUAL. 1 Version: 22. June 2010

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

WIO200 Water In Oil measuring instrument

Cat. No TPT44. Installation & Operating Instructions

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Lonworks Damper Interface Catalogue

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

LAE10 LFE10. Use. Series 02

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

Analox Safe-Ox/Safe-Ox He

Transcription:

Product Overview The HF9101-V1 is an electronic thermostat designed to give energy-efficient frost protection to pipe work where thermal insulation alone cannot protect pipes from freezing or being damaged by ice. The unit controls heater tape or Infra-Red (IR) quartz lamps. Features & Benefits Simple setup & installation Includes sensor Temperature Trip Point 4 C 1 C Hysteresis Maintenance free IP65 Ingress protection Current capacity 25A Max. Sensor & load fault detection Power & Status LED indicators BMS Load On output Product Setup Connect the mains supply and load to the controller using the appropriate cable. If connecting the BMS output, ensure appropriate IP rated gland is used. Operation When the mains supply is switched on the Power LED will illuminate and the microprocessor with run a check to ensure the sensor and load are working correctly. When the ambient temperature drops below the pre-set temperature of 4 C, the load output relay energises the status LED will illuminate and BMS output is on. When the ambient temperature is equal to or greater than the set point temperature, the load output switches off and the output LED and BMS output will be off. Alarms The unit can detect an open-circuit or short-circuit temperature sensor. In addition to this, the unit tests the output immediately at power up and every four hours thereafter. The output will switch off momentarily during a test. Normal operation will resume once the test is complete. Alarm relay fitted (see specifications, BMS).

The unit can detect the following faults: 1) Open-circuit/short-circuit temperature sensor. 2) Open-circuit load. In all above cases, the alarm LED will flash. For the temperature sensor alarm the rate is approximately one tenth of a second and for the load alarm the rate is approximately half a second. BMS is set as a load run indicator only. Fusing It is recommended to use standard F-type quick-blow fuse or circuit breaker (MCB type D) rated at 30A Max. for in line unit protection. (See the SRA Datasheet for further information). CE Marking This product family carries a CE marking and are RoHS compliant. For further information contact our sales desk. (See the Declaration of Conformity). Recommendation Other documents are available on request, which may be appropriate for your applications. Code Identity Description X10255 SRA Safety requirements - addressing the Low Voltage Directive (LVD) including:- Thermal data/cooling; Live parts warning & Earth requirements; Fusing recommendations. AP02/4 COS UAL Conditions of sale Note: It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements regarding safety of electrical equipment. (For International Standards refer to I.E.C. Directive I.E.C. 950).

Technical Specification (all models unless otherwise stated) Supply Voltage 230V AC +/- 10% Supply Frequency 50Hz Power Switching Capacity 25A Max. Load Current 25A Max. Temperature Set Point (Fixed) 4 C Temperature Accuracy 1 C Current Consumption 16mA Power & Output LED Indicators (see ALARMS section for details) Supply Terminal Connections 0.2 to 6mm² Rising clamp Ambient Operating Temperature -20ºC to +40ºC Ingress Protection (IP) Rating IP65 Built in Sensor Encapsulated 10kΩ NTC thermistor probe Sensor Monitoring HF9101: open or short circuit - unit shuts down and alarms Sensor Terminal Connections 0.1 to 1.5mm² Rising clamp Building Management System (BMS) Alarm relay normally energised when load is ON Enclosure Dimensions 130(W) x130(l) x75((h) mm Fixing Hole & Centre Dimensions 4x4.8mm Ø holes on fixing centres 115(W) x115(l) mm Contact Information T&D (Gateshead) T&D (Bristol) Gear House Units 9 & 10 Saltmeadows Road Birchills Trading Estate Gateshead Emery Road NE8 3AH Brislington Bristol BS4 5PF Phone: 01914901547 Phone: 01179774647 Northernsales@thorneandderrick.co.uk Southernsales@thorneandderrick.co.uk

Installation Mounting NOTE: If mounted in the vertical plane the glands MUST be as shown to ensure IP rating.

Installation Wiring Diagram shows the wiring connections and cable entry NOTE: The glands (not supplied except sensor gland) MUST be tightened to ensure the IP rating. The set point control dial is also shown.