INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

Similar documents
INSTALLATION & USER INSTRUCTIONS

THIS INSTRUCTION BOOKLET MUST BE LEFT WITH THE USER

16 Ultiflame Inset Electric Fire

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION & USER INSTRUCTIONS

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

INSTALLER AND OWNER GUIDE

16 XD Mk2 Inset Electric Fire

CELSI ELECTRIFLAME XD

Imperial Electric Fires

COAL EFFECT BALANCED FLUE GAS FIRE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Kalahari RC & Camber RC

INSTALLATION & USER INSTRUCTIONS

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE

OPERATING & MAINTENANCE INSTRUCTIONS

INSTALLER AND OWNER GUIDE

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

Use & Care Manual Inset Electric Fires

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Wall Mount Electric Fire Place with Remote Control

Use & Care Manual Contemporary Electric Fires

Installation Instructions & Operating Manual IMPORTANT

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

BALANCED FLUE LOG EFFECT GAS FIRE

INSTALLATION & USER INSTRUCTIONS

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

SP16. 08/50740/1 (UK) - Issue 1

Contact Details. Please note that some of the contact details on this PDF document may not be current.

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

INSTALLATION & USER INSTRUCTIONS

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

Installation & User Instructions:

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

INSTALLER AND OWNER GUIDE

Dovre 280 or 425 Electric

Imperial Electric Fires

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

INSTALLATION & USER INSTRUCTIONS

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

Oil Panel Heater Instructions for Use

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

INSTALLATION & USER INSTRUCTIONS

Operating Instructions

FUEL EFFECT POWERFLUE GAS FIRES

2kw Remote Control Electric Fire. User and Installation Instructions

ASTRO PORTABLE LPG CABINET HEATER Model No. KCH

INSTALLATION & USER INSTRUCTIONS

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

2000W Ceramic Wall Heater with LED Display

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ELECTRIC FIREPLACE with Remote Control

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

2400W Ceramic Tower Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ST E /ST E / ST E / ST E ST E / ST E / ST E

INSTALLATION & USER INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference:

FIGARO. 08/52543/0 (UK) Issue 1

E-MAL1 E-AW1 E-NEO. Malvern Electric Astwood Electric NEO Electric T E C H N I C A L & U S E R M A N U A L

INSTALLATION & USER INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

2kW ELECTRIC HEATER WITH REMOTE CONTROL NEBRASKA NEBRASKA

Contact Details. Please note that some of the contact details on this PDF document may not be current.

DEVIL CERAMIC SPACE HEATERS

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

FAN HEATER FH118 User Manual

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

Spiral Dough Mixer. Instruction manual. Model: CP821

Heating Indicator Thermostat Control Inner Pan Heating Element Food Basket Removable handle

COOKWORKS TWIN PROFESSIONAL FRYER INSTRUCTION MANUAL

Installation and Maintenance Instructions XPG170 Electric Fires

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

26 FIREBOX EN RU UA FR

Transcription:

INSTALLATION AND USER INSTRUCTION GUIDE Model (s) Renaissance / Strata / Misermatic Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2 ** Denotes case colour / finish This guide should be used to install and care for your Flavel Electric heater. Read all information carefully prior to installation and use.

Installation IMPORTANT Please read the instructions below before installation or use of this Flavel Electric Heater. use this heater where it may come into contact with water i.e. bathroom, shower room, kitchen. leave unsupervised children where the heater is left switched ON or is left unguarded. use this heater beneath a fixed socket outlet. cover or obstruct the outlet, as this will cause the appliance to overheat. install the heater close to combustible materials i.e. curtains or similar. Allow a minimum of one metre around the heater. route the mains cable beneath carpet. use aerosols or similar close to the heater. use the heater to dry clothes or similar. use the heater by means of an automatic control or timer, as this may cause risk of fire if the heater is moved or covered. fit the heater directly onto carpet or similar material. It should be fitted onto a suitable non-combustible hearth The appliance MUST be disconnected from the mains supply before commencing cleaning, or maintenance. Ensure the heater is firmly secured to the fixing plain to prevent it from falling forward. Use a suitable fireguard to protect both the infirm and young children who could come into contact with the heater. Appliance Data Supply Voltage 230V ac 50Hz Fuse Rating 13 Amp Heating Element 2 x 1kW Mains Cable 1 x 2M PVC 1mm 2 Cable Illumination 2 x 60W Clear Filament Bulb 2

Installation Requirements This Flavel Electric Fire is supplied with a moulded three-pin plug (13Amp) and approximately 2 metres of flexible mains cable (1mm 2 ). The appliance and surround should therefore be located close to a suitable mains socket to enable connection. The electrical socket MUST be easily accessible to allow disconnection. This heater MUST be earthed. Connections L = Brown N = Blue E = Green / Yellow Replacement fuses should be approved and conform to BS 1362. Before use ensure that the supply voltage matches that marked on the appliance. The mains cable should be routed from the heater to the socket connection without being trapped or being liable to damage. If the mains cable is damaged the heater must be returned to :- BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, ST4 4TJ IMPORTANT : THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. ANY ELECTRICAL WORK MUST BE CARRIED OUT BY A COMPETENT, QUALIFIED ELECTRICIAN. THIS APPLIANCE CAN BE USED BY CHILDREN AGED 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. THIS HEATER IS NOT EQUIPPED WITH A DEVICE TO CONTROL THE ROOM TEMPERATURE. DO NOT USE THIS HEATER IN SMALL ROOMS WHEN THEY ARE OCCUPIED BY PERSONS NOT CAPABLE OF LEAVING THE ROOM ON THEIR OWN, UNLESS CONSTANT SUPERVISION IS PROVIDED. THE DATA BADGE IS POSITIONED ON THE INNER REAR FACE OF THE HEATER, REMOVE THE CASE AS DESCRIBED IN SECTION C) ON PAGE 4 IF REQUIRED TO VIEW THE INFORMATION. 3

Unpacking The Appliance This Flavel Electric heater is supplied in a single pack carton. All Instructions should be read prior to installing the appliance. Ensure all parts including loose items have been removed prior to discarding the packaging. Product Checklist 1 off Flavel electric heater main body including bulb assembly units 1 off Ceramics pack (contains four ceramic plaques) 1 off Fixing kit 1 off Instruction / guarantee Literature 1 off Control knob Appliance Fixing BEFORE PROCEEDING, ENSURE THE APPLIANCE IS DISCONNECTED FROM THE MAINS SUPPLY. IF IN DOUBT SEEK THE ASSISTANCE OF A QUALIFIED ELECTRICIAN. Wall Mounting. (Non Combustible Walls Only) NOTE: When the fire is wall mounted, the base of the fire must be a least 150mm above the floor level. a) Remove the dress guard by springing the location wires out at the top (at the sides on Renaissance models) and lifting away. Take care not to scratch the trim. b) Remove the radiant's and their packaging from the fire and store in a safe place. c) Remove the two lower outer case fixing screws and the two upper outer case fixing screws. (On Strata models the case is only secured by lower outer case fixing screws). Remove the outer case by lifting upwards and away, ensuring the rear of the outer case clears the top of the switch spindle area at the top right. Remove the legs from the base of the fire if wall mounting. d) Mark the position of the upper fixing holes on the wall with reference to diagram overpage. The height of the upper holes should be at least 580mm above the floor. This will determine the 145mm height required from the base of the fire to the floor. 4

6 0 0 m m U p p e r F i x i n g S c r e w P o s i t i o n ( K e y h o l e S l o t s ) 4 3 5 m m B a s e t o C R S 4 2 m m C R S L o w e r F i x i n g S c r e w P o s i t i o n 1 4 5 m m M i n i m u m e) Drill and plug the upper holes with the wall plugs supplied. f) Fit the 4 screws through the holes in the firebox back panel and tighten to secure the fire to the wall. g) Replace the outer case in the reverse order to which it was removed. h) Ensure the orange filter is in place. i) Remove the ceramics from their packaging and place in fire, ensuring they are fitted, see page 6 for fitting instructions for the ceramics. j) Fit control knob once case has been re-fitted. NOTE: It is recommended that the fire is not installed below any combustible shelf. Operation of Heater The heater is operated via the use of a rotary switch situated on the top right hand side of the heater. Marking OFF LIGHTS LOW HIGH Operation Appliance is non-operational Depress and turn to LIGHTS. Gives a lights only function Depress and turn to LOW. Gives a lights plus 1kW heat setting Depress and turn to HIGH. Gives a lights plus 2kW heat setting Note: The rotary switch has an accidental / child prevention operation, therefore the control knob should be depressed before turning to the required position. 5

How to fit the ceramic plaques Tilt the ceramic plaque to the rear, insert at the top, lift and rotate backwards into position then refit dress guard in reverse method to that described on page 4, section a) Strata Models Misermatic Models Renaissance Models 6

IMPORTANT - Safety Cut Out This appliance is fitted with an automatic safety cut out. This operates if the air inlet or outlet of the heater become blocked or covered. This will prevent the fan heater from operating. In order to RESET the appliance the following procedure should be followed:- Switch OFF the appliance and disconnect the appliance from the mains supply Leave the appliance disconnected for a MINIMUM of 10mins Check the appliance is free from all obstructions and remove safely Switch ON the appliance at the mains supply socket Operate the appliance as shown above If the appliance fails to operate, repeat the above procedure ENSURING the appliance is disconnected from the mains supply at the wall socket. If after repeating this procedure the appliance fails to operate CHECK the fuse within the wall socket / plug. If after carrying out both of the above procedures the appliance still fails to operate, then call a competent Service Engineer. CAUTION : In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. Care and Cleaning Always disconnect the appliance from mains supply and allow to cool before any cleaning operation begins. Chrome parts can be cleaned using a clean, damp cloth. The Side / end panels and any metal painted parts may be cleaned using a clean, damp cloth. Never use any abrasive cleaners and chemical agents as damage may occur to the paint finish. Maintenance WARNING BEFORE CARRYING OUT ANY MAINTENANCE, ENSURE THAT THE APPLIANCE IS DISCONNECTED FROM THE MAINS ELECTRICAL SUPPLY. IF IN DOUBT SEEK THE ASSISTANCE OF A QUALIFIED ELECTRICIAN It is advisable to use genuine Flavel replacement parts available from your supplier or direct from Flavel. (Contact details on the rear of this booklet) 7

Bulb Replacement 60W Filament Bulb(s) 1. Disconnect the appliance from the mains supply. 2. Remove the chrome dress guard, by pulling forward. 3. Carefully remove the four ceramic radiant s by lifting them slightly then pulling them forward. 4. Remove the colour filter from within the heater aperture. 5. Unscrew the bulb from the bulb holder. (There are two bulbs housed in the reflector assembly). 6. Remove the bulb. 7. Re-assemble in reverse order. Spare Parts List Bulb B-51730 Ceramic radiant s (pack of four) B-48680 Coloured Filter B-60060 Part No. B-173550 Issue 4 BFM Europe Ltd. Trentham Lakes Stoke-on-Trent Staffordshire ST4 4TJ www.bfm-europe.com Telephone - General Enquiries : (01782) 339000 Telephone - Service : (0844) 7700169 or (01782) 339008 8