Sensor INFORMATI Series Features Polycarbonate Resin, -wire/-wire DC System - Front Surface / Upper Surface detection - s of different frequency are available for adjacent installation. - Conformity with UL standard / CE mark - NO/NPN/PNP output Type -wire DC System Form Operating Distance (mm) Form Remarks Non-flush Mount Type NO APS-M-Z NO APS-S-Z models are available. models are available. * models (L) are made-to-order products. -wire DC System Form Operating Distance (mm) Form Remarks.5 NPN NO APS.5-M-E Non-flush Mount Type NPN NO APS-M-E NPN NC APS-M-E PNP NO APS-M-E.5 NPN NO APS.5-S-E models are available. (Excluding E type) NPN NO NPN NC PNP NO APS-S-E APS-S-E APS-S-E models are available. (Excluding E type) Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/
Sensor Series -wire DC System Non-flush Mount Type Effective Operating Distance mm % Photo INFORMATI Remarks models are available./with action indication/ Upper surface detection Front surface detection Form NO APS-S-Z APS-M-Z Price (Minimum order quantity: 5 pieces) (Minimum order quantity: 5 pieces) Rated Working Voltage Standard (mm) Guaranteed Operating Distance / V DC ( to 0 V DC) Allowable ripple rate: % p-p or less Iron 0 x 0 x t 0 to. mm Reaction Material Hysteresis Operating Cycle Frequency Rated Working Current Voltage Drop Off-state Current Indicator Lamp Use Ambient Temperature Temperature Characteristics Withstand Voltage Insulation Resistance Vibration Resistance Impact Resistance Protection Level Case Material Lead Wire Tightening Torque Iron/Non ferrous metal (Operating distance changes depending on materials.) Approx. 0% or less Up to 00 Hz 5 to 50 ma V or lower.0 ma or lower indication - to 50 C Within 0% (At the operating distance at C) 500 V AC 50/0 Hz ( minute) 50 MΩ or higher (500 V DC) Double amplitude:.5 mm, to 55 Hz ( h each for X, Y and Z direction) 9m/s, within ms ( times each for X, Y and Z direction) IP Polycarbonate Oil-resistant cable m Outside diameter ( ) 0. mm, core 0. Nm or less Weight (g) Approx. 0 * "L" is attached to the end of model number of the various frequency-classified models. (Made-to-order product) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 5
Sensor Series -wire DC System Non-flush Mount Type Effective Operating Distance.5 mm 5% mm % INFORMATI Photo Remarks Form NPN NO NPN NC Price Price With operation indication / Excluding mounting bracket (APS-KNG, option) models are available. (Excluding E type) With action indication/ Upper surface detection Front surface detection Upper surface detection Front surface detection APS.5-S-E APS.5-M-E APS-S-E APS-M-E (Minimum order quantity: units) (Minimum order quantity: units) APS-S-E APS-M-E PNP NO Rated Working Voltage Price / V DC ( to 0 V DC) Allowable ripple rate: % p-p or less APS-S-E No-load Current 0 ma or lower ma or lower Standard (mm) Iron 5 x 5 x t Iron 0 x 0 x t Guaranteed Operating Distance Reaction Material Hysteresis 0 to. mm 0 to. mm Iron/Non ferrous metal (Detection distance changes depending on materials.) 0% or less Operating Cycle Frequency Up to 500 Hz Up to 00 Hz Rated Working Current Voltage Drop Off-state Current Indicator Lamp Use Ambient Temperature Temperature Characteristics Withstand Voltage Insulation Resistance Vibration Resistance Impact Resistance Protection Level Case Material Lead Wire Tightening Torque Up to 50 ma.0 V or lower 0. ma or lower indication - to 50 C Within 0% (At the operating distance at C) 500 V AC 50/0 Hz ( minute) 50 MΩ or higher (500 V DC) Double amplitude:.5 mm to 55 Hz 9 m/s, within ms ( times each for X, Y and Z direction) IP Polycarbonate Oilproof cable m Outside diameter ( ) 0. mm, core 0. Nm or less Weight (g) Approx. 9 Approx. 0 APS-M-E * "L" is attached to the end of model number of the various frequency-classified models. Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/
Sensor Connection/ Sensor -wire DC System -Z Sensor -wire DC System NPN -E Sensor -wire DC System NPN -E Series Connection and The load can be connected to either side of the power source. Black Black Not Present Present ( ) INFORMATI -wire DC System PNP -E Sensor Black Note: indicates a load. Installation / Effects of Surrounding Metal Since the proximity sensor is affected by surrounding metal, install it remotely enough from the described dimensions. Installation - Parallel arrangement of infinite plane metal body A * - Parallel arrangement of plane metal body to the detector surface B * - Arrangement to fenestrate metal body C - Arrangement of metal body at the front (Unit: mm) - Parallel arrangement - Opposing arrangement Front detection type - Opposing arrangement Top detection type D APS.5-S-..... 0 APS.5-M-... 0 APS-S-....5.5 0 0 APS-M-... 0 5 0 0 * Position of the target body in the top detection models - When there is metal around the proximity sensor, the operating distance changes and makes operation unstable. Therefore, place the surrounding metal as remotely as possible from the proximity sensor. - Since the D dimension (mm) is the minimum value from the proximity sensor's detector surface to the surrounding metal body, place the metal more remotely than the numeric values shown in the table above. - When the B dimension of the APS.5 to the M is. mm (tight installation), place the proximity sensor's detector surface at least mm away from the surrounding metal. D D D Precautions when handing the product Before Using the Product Note that this product may output detection signals for approx. 5 ms when there are no objects detected and for approx. 0 ms when there is a detected object nearby after the power is turned on. Precautions in Installation The screws should be tightened so that no stress is applied to the sensor. *Tightening torque specifications: If the screws are tightened with a force 0. Nm or more, the sensor may break. UL Certification If you use the proximity sensor as a UL certification product, use a Class power source. UL certification products receive recognition on condition that the Class power source is used. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0
Sensor INFORMATI Series Connection and Mutual Interference and Frequency Classification When two or more proximity sensors are closely installed, the installation interval of the sensors should be more than times the operating distance (between centers). If the interval is too short, mutual interference may occur. If the interval cannot be sufficiently secured, use modes with differently classified frequency. The frequency classification is represented by the alphabet after the operating distance in the normal model number. - s with a classified frequency are shown by the mark on the cable. L-band mark (Example) APS-S-E (M)... of standard frequency -E (M is not normally indicated.) APS-S-EL... with lower frequency than the standard Combination of s Classified by Frequency (The sensors can be mounted with the cases tightly attached.) APS- - (M)L (Excluding E type) The sensors can be mounted with the cases tightly attached. L (M) * It requires consideration when or more sensors are closely mounted. Detection Range Diagram (Representative Examples) APS-S/M-... Operating Distance (mm) APS.5-S/M-E Operating Distance (mm).5 5 Return.5.5 Return 0.5 0 Distance from the Center of Sensor (mm) 0 Distance from the Center of Sensor (mm) Shape Based Characteristics (Representative Examples) APS-S/M-... Operating Distance X (mm) 0 0 0 Iron Dimensions of One Side of the "a" (mm) SUS0 Aluminum Copper x a t = mm APS.5-S/M-E Operating Distance X (mm) Iron SUS0 Aluminum Copper x 0 0 0 Dimensions of One Side of the "a" (mm) a t = mm Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/
Sensor Series. Hole.5 Dimensions APS- APS-S-E/ Scal Installation (Unit: mm) APS-S-... M 0.5 Pan-head Screw (Recommended) APS-M-.... Hole M 0.5 Pan-head Screw (Recommended) Detector Surface S-S/M ctor Surface.5 Hole.5 0. 0 APS.5-S/M-E. Hole Detector Surface.5 0. 0 Hole ±0. M 0.5 Tapped Hole or. Hole If the attachment bore is., anchor the proximity sensor M 0.5 Pan-head Screw (Recommended).5 M 0.5 Tapped Hole or. Hole ±0.. Hole Detector Surface Hole.5 0. 0 APS-S-Z APS-S-E/E/E.5 ±0. M 0.5 Tapped Hole or. Hole. Hole : APS.5-M If the attachment bore is., anchor the proximity sensor. 5. APS-S-Z APS-S-E/E/E. Hole.5 : APS.5-S.5 APS- APS-M-E/ Scal INFORMATI Sensor APS.5-S-E LineupAPS.5- Scale * The mounting fixture is sold separately. Dimensions (Unit: mm) APS-S-.... Hole.5.5. Hole. Hole.5 : APS.5-S.5. Hole : APS.5-M. 5. APS-M-.... APS-M-Z APS-M-E/E/E.. 9. APS.5-S-E APS.5-M-E.... Hole 5.5. APS-M-Z APS-M-E/E/E 0.t.5 0. APS.5-S/M-E : APS.5-S.5 Method for Machining The Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor.5 : APS.5-M. Hole : APS.5-S. 5. Mounting Brackets Dimensions (Unit: mm) APS-S/M Mounting Brackets * Enclosed 5 pieces per box.... APS.5-S-E APS.5-M-E : APS.5-M. Hole. 5. APS.5-S/M Mounting Brackets * Excluded as an option 5.5.5 number APS-KNG Price (One unit) * Minimum sales unit: units. 9. 5. 5.5. 5.5. 0.t. (Inside Dimension). 0.. 0. Method for Machining The Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. Method for Machining the Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 9