APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Similar documents
panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

E3M-V. Mark Sensor. Applications

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Ultrasonic Proximity Sensor

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Laser Collimated Beam Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Flameproof Type Light Curtain Type 4

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

onlinecomponents.com

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

02/11/2015

AnyWireASLINK System Products Guide

02/11/2015

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

E3FA PHOTOELECTRIC SENSORS

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Ultrasonic Proximity Sensor

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

ESP TECHNOLOGIES LIMITED

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Technical Data. Dimensions

ISIS SAFETY SYSTEM Installation guide

Ceiling Mount Temperature Sensor

Thermal Management Products & Accessories for Enclosures

M7100 Pressure Transducer

Retroreflective sensor with polarization filter

MEASURING DISTANCE TYPE OBSTACLE DETECTION SENSOR PBS-03JN SPECIFICATIONS

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

PHOTOELECTRIC AMPLIFIER SERIES

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating Manual MS220KA and MSR220KA

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

General Purpose Photoelectric Sensor

Technical Data. Dimensions

Ultrasonic Reflective Sensor

Retroreflective sensor with polarization filter

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

NXM2G Installation and Operating Manual

Background suppression photo sensors

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Technical Data. General specifications. Rated operating distance s n 5 mm

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

General Specifications

Operating Manual TR600

Ultrasonic Reflective Sensor

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Limit Switch Box YT-870/875 SERIES

Plug-in Base, Long Range Sensor E3B2

Quick-disconnect cables. Adjustable mounting brackets

2 General Application Photoelectric Sensors

160W High Intensity UV LED Light - UVA/365NM V AC - Acrylic Lens

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

UNIVERSAL COMPACT SENSORS

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

E3FA PHOTOELECTRIC SENSORS

Technical Data. Dimensions

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Automatic Self-Adjusting General Purpose Sensor

Original instructions Sense7-series Non-contact coded safety switch

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

5.0. Photoelectric Sensors. Technical Reference. Introduction

InductIve SenSorS 2018

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Operating Manual MS220DA

Transcription:

Sensor INFORMATI Series Features Polycarbonate Resin, -wire/-wire DC System - Front Surface / Upper Surface detection - s of different frequency are available for adjacent installation. - Conformity with UL standard / CE mark - NO/NPN/PNP output Type -wire DC System Form Operating Distance (mm) Form Remarks Non-flush Mount Type NO APS-M-Z NO APS-S-Z models are available. models are available. * models (L) are made-to-order products. -wire DC System Form Operating Distance (mm) Form Remarks.5 NPN NO APS.5-M-E Non-flush Mount Type NPN NO APS-M-E NPN NC APS-M-E PNP NO APS-M-E.5 NPN NO APS.5-S-E models are available. (Excluding E type) NPN NO NPN NC PNP NO APS-S-E APS-S-E APS-S-E models are available. (Excluding E type) Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/

Sensor Series -wire DC System Non-flush Mount Type Effective Operating Distance mm % Photo INFORMATI Remarks models are available./with action indication/ Upper surface detection Front surface detection Form NO APS-S-Z APS-M-Z Price (Minimum order quantity: 5 pieces) (Minimum order quantity: 5 pieces) Rated Working Voltage Standard (mm) Guaranteed Operating Distance / V DC ( to 0 V DC) Allowable ripple rate: % p-p or less Iron 0 x 0 x t 0 to. mm Reaction Material Hysteresis Operating Cycle Frequency Rated Working Current Voltage Drop Off-state Current Indicator Lamp Use Ambient Temperature Temperature Characteristics Withstand Voltage Insulation Resistance Vibration Resistance Impact Resistance Protection Level Case Material Lead Wire Tightening Torque Iron/Non ferrous metal (Operating distance changes depending on materials.) Approx. 0% or less Up to 00 Hz 5 to 50 ma V or lower.0 ma or lower indication - to 50 C Within 0% (At the operating distance at C) 500 V AC 50/0 Hz ( minute) 50 MΩ or higher (500 V DC) Double amplitude:.5 mm, to 55 Hz ( h each for X, Y and Z direction) 9m/s, within ms ( times each for X, Y and Z direction) IP Polycarbonate Oil-resistant cable m Outside diameter ( ) 0. mm, core 0. Nm or less Weight (g) Approx. 0 * "L" is attached to the end of model number of the various frequency-classified models. (Made-to-order product) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 5

Sensor Series -wire DC System Non-flush Mount Type Effective Operating Distance.5 mm 5% mm % INFORMATI Photo Remarks Form NPN NO NPN NC Price Price With operation indication / Excluding mounting bracket (APS-KNG, option) models are available. (Excluding E type) With action indication/ Upper surface detection Front surface detection Upper surface detection Front surface detection APS.5-S-E APS.5-M-E APS-S-E APS-M-E (Minimum order quantity: units) (Minimum order quantity: units) APS-S-E APS-M-E PNP NO Rated Working Voltage Price / V DC ( to 0 V DC) Allowable ripple rate: % p-p or less APS-S-E No-load Current 0 ma or lower ma or lower Standard (mm) Iron 5 x 5 x t Iron 0 x 0 x t Guaranteed Operating Distance Reaction Material Hysteresis 0 to. mm 0 to. mm Iron/Non ferrous metal (Detection distance changes depending on materials.) 0% or less Operating Cycle Frequency Up to 500 Hz Up to 00 Hz Rated Working Current Voltage Drop Off-state Current Indicator Lamp Use Ambient Temperature Temperature Characteristics Withstand Voltage Insulation Resistance Vibration Resistance Impact Resistance Protection Level Case Material Lead Wire Tightening Torque Up to 50 ma.0 V or lower 0. ma or lower indication - to 50 C Within 0% (At the operating distance at C) 500 V AC 50/0 Hz ( minute) 50 MΩ or higher (500 V DC) Double amplitude:.5 mm to 55 Hz 9 m/s, within ms ( times each for X, Y and Z direction) IP Polycarbonate Oilproof cable m Outside diameter ( ) 0. mm, core 0. Nm or less Weight (g) Approx. 9 Approx. 0 APS-M-E * "L" is attached to the end of model number of the various frequency-classified models. Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/

Sensor Connection/ Sensor -wire DC System -Z Sensor -wire DC System NPN -E Sensor -wire DC System NPN -E Series Connection and The load can be connected to either side of the power source. Black Black Not Present Present ( ) INFORMATI -wire DC System PNP -E Sensor Black Note: indicates a load. Installation / Effects of Surrounding Metal Since the proximity sensor is affected by surrounding metal, install it remotely enough from the described dimensions. Installation - Parallel arrangement of infinite plane metal body A * - Parallel arrangement of plane metal body to the detector surface B * - Arrangement to fenestrate metal body C - Arrangement of metal body at the front (Unit: mm) - Parallel arrangement - Opposing arrangement Front detection type - Opposing arrangement Top detection type D APS.5-S-..... 0 APS.5-M-... 0 APS-S-....5.5 0 0 APS-M-... 0 5 0 0 * Position of the target body in the top detection models - When there is metal around the proximity sensor, the operating distance changes and makes operation unstable. Therefore, place the surrounding metal as remotely as possible from the proximity sensor. - Since the D dimension (mm) is the minimum value from the proximity sensor's detector surface to the surrounding metal body, place the metal more remotely than the numeric values shown in the table above. - When the B dimension of the APS.5 to the M is. mm (tight installation), place the proximity sensor's detector surface at least mm away from the surrounding metal. D D D Precautions when handing the product Before Using the Product Note that this product may output detection signals for approx. 5 ms when there are no objects detected and for approx. 0 ms when there is a detected object nearby after the power is turned on. Precautions in Installation The screws should be tightened so that no stress is applied to the sensor. *Tightening torque specifications: If the screws are tightened with a force 0. Nm or more, the sensor may break. UL Certification If you use the proximity sensor as a UL certification product, use a Class power source. UL certification products receive recognition on condition that the Class power source is used. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0

Sensor INFORMATI Series Connection and Mutual Interference and Frequency Classification When two or more proximity sensors are closely installed, the installation interval of the sensors should be more than times the operating distance (between centers). If the interval is too short, mutual interference may occur. If the interval cannot be sufficiently secured, use modes with differently classified frequency. The frequency classification is represented by the alphabet after the operating distance in the normal model number. - s with a classified frequency are shown by the mark on the cable. L-band mark (Example) APS-S-E (M)... of standard frequency -E (M is not normally indicated.) APS-S-EL... with lower frequency than the standard Combination of s Classified by Frequency (The sensors can be mounted with the cases tightly attached.) APS- - (M)L (Excluding E type) The sensors can be mounted with the cases tightly attached. L (M) * It requires consideration when or more sensors are closely mounted. Detection Range Diagram (Representative Examples) APS-S/M-... Operating Distance (mm) APS.5-S/M-E Operating Distance (mm).5 5 Return.5.5 Return 0.5 0 Distance from the Center of Sensor (mm) 0 Distance from the Center of Sensor (mm) Shape Based Characteristics (Representative Examples) APS-S/M-... Operating Distance X (mm) 0 0 0 Iron Dimensions of One Side of the "a" (mm) SUS0 Aluminum Copper x a t = mm APS.5-S/M-E Operating Distance X (mm) Iron SUS0 Aluminum Copper x 0 0 0 Dimensions of One Side of the "a" (mm) a t = mm Visit our website KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 Latest catalog (free) is available online. http://www.koyoele.co.jp/english/

Sensor Series. Hole.5 Dimensions APS- APS-S-E/ Scal Installation (Unit: mm) APS-S-... M 0.5 Pan-head Screw (Recommended) APS-M-.... Hole M 0.5 Pan-head Screw (Recommended) Detector Surface S-S/M ctor Surface.5 Hole.5 0. 0 APS.5-S/M-E. Hole Detector Surface.5 0. 0 Hole ±0. M 0.5 Tapped Hole or. Hole If the attachment bore is., anchor the proximity sensor M 0.5 Pan-head Screw (Recommended).5 M 0.5 Tapped Hole or. Hole ±0.. Hole Detector Surface Hole.5 0. 0 APS-S-Z APS-S-E/E/E.5 ±0. M 0.5 Tapped Hole or. Hole. Hole : APS.5-M If the attachment bore is., anchor the proximity sensor. 5. APS-S-Z APS-S-E/E/E. Hole.5 : APS.5-S.5 APS- APS-M-E/ Scal INFORMATI Sensor APS.5-S-E LineupAPS.5- Scale * The mounting fixture is sold separately. Dimensions (Unit: mm) APS-S-.... Hole.5.5. Hole. Hole.5 : APS.5-S.5. Hole : APS.5-M. 5. APS-M-.... APS-M-Z APS-M-E/E/E.. 9. APS.5-S-E APS.5-M-E.... Hole 5.5. APS-M-Z APS-M-E/E/E 0.t.5 0. APS.5-S/M-E : APS.5-S.5 Method for Machining The Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor.5 : APS.5-M. Hole : APS.5-S. 5. Mounting Brackets Dimensions (Unit: mm) APS-S/M Mounting Brackets * Enclosed 5 pieces per box.... APS.5-S-E APS.5-M-E : APS.5-M. Hole. 5. APS.5-S/M Mounting Brackets * Excluded as an option 5.5.5 number APS-KNG Price (One unit) * Minimum sales unit: units. 9. 5. 5.5. 5.5. 0.t. (Inside Dimension). 0.. 0. Method for Machining The Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. Method for Machining the Mounting Holes 0..5 --0 Hole M x 0.5 tap or. hole If the attachment bore is., anchor the proximity sensor KOYO ELECTRICS INDUSTRIES CO., LTD. GENERAL CATALOG 0 9