Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Similar documents
Engineered for flexibility and performance

Commercial Packaged Rooftop Systems

Trailblazer air cooled scroll chillers

RoofPak Applied Rooftop Systems

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Maverick II Commercial Rooftop Systems 15 to 75 tons

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Vision and Skyline Semi-custom Air Handlers

Innovation for a Better & Greener Future

Centrifugal Compressor Water Chillers THE DISTINCTION SERIES

Centrifugal Compressor Water Chillers Catalog 605 Models WSC, WDC, WCC, HSC

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

ENGINEERING. Edition No. 13 October 2002

sm All Product Catalog

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

CVGF. Water Cooled Centrifugal Chillers

Product Line Card. Daikin Applied HVAC system solutions. Advanced technology and solutions from the world s leading innovator in HVAC.

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Product Data. Features/Benefits ComfortLink control

Reinventing Energy Efficiency

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Cultivator & Hybrid Cultivator

Centrifugal Compressor Water Chillers

Smardt Oil-Free Chillers

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Daikin Blueprint: Delivering Hot Water with a Chiller

LUCKILY THERE S A BETTER WAY

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

THE ULTIMATE ROOFTOP SOLUTION

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

Variable Refrigerant Flow (VRF) Systems

Air conditioning 23XRV

NQ Series Portable Chillers

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

Water Source Heat Pumps. Energy efficient heating and cooling commercial applications

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Upgrades for Control Enclosures and Screw Compressors

VariCool VAV Engineering Guide

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance Line

HIGH EFFICIENCY WEATHERMAKER 38TPA

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

MEDICAL CHILLER SYSTEMS

Product line card. A comprehensive line of HVAC system solutions.

Voyager. 12½ to 25 Ton Light Commercial Packaged Units with ReliaTel Microprocessor Controls

Scroll Chillers Transition from HCFC-22 to HFCs

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

Water Source Heat Pumps

GeneSys. Air-Cooled Screw Compressor Chillers. Catalog

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Air-cooled Screw Chillers Model RTAF G Process

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

Catalog Maverick II Commercial Packaged Rooftop Systems. Engineered for flexibility and performance

ROOFTOP PACKAGED AIR CONDITIONERS

HVAC Water chiller selection and optimisation of operation

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

QUANTUM. Series and features of the energy-efficient chiller series

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Centrifugal, Magnetic Bearing, Compressor Water Chiller Model WMC-035T, 110 to 175 Tons

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Nirvana. Cycling Refrigerated Dryers

TRIDENT GS SERIES Central Chiller

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Xc21 air conditioner up to seer Xc21

OACS Outdoor Air-Cooled Central Chillers

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Leadership, Innovation, Advanced Technology Synergise Here!

Heat Pumps COMFORT NEED IT. When You

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Water-cooled chillers with High Speed Centrifugal Compressors

Innovative Design, Performance, & Serviceability

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Nirvana Cycling Refrigerated Dryers

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Catalog Trailblazer Air-Cooled Scroll Compressor Chillers With High Efficiency Variable Speed Fan Technology

Transcription:

Your Chiller Solution For Efficiency And Reliability McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

McQuay Dual Compressor Centrifugal Chillers Superior part load efficiency, reliability and low installed cost McQuay dual compressor centrifugal chillers offer you the best part load efficiency in the industry today. Our design has been proven in thousands of installations around the world since 1971. These chillers are built in an ISO-certified facility for consistent, dependable quality, and factory tested on ARIcertified test stands for reliable start-up and operation at the job site. Installed Cost Savings Two Chillers in One Package The smaller footprint of a dual centrifugal chiller in an equipment room uses less floor space than multiple single compressor chillers required to produce the same capacity. Also, a dual compressor chiller can mean installed cost savings of up to 35% compared to installing two separate chillers. Eliminates piping to the second chiller and to additional pumps Fewer valves and controls Less rigging costs Less equipment mounting pads Less control wiring Redundancy for Added Reliability In buildings with critical applications that can t afford downtime due to a chiller failure, an economical solution is the McQuay dual compressor centrifugal chiller with two of everything connected to a common evaporator and condenser. This redundancy provides 60% of the design cooling capacity with only one compressor running. The Part Load Efficiency Advantage Operational Savings When It Counts Chillers spend 99% of the time under part load conditions. That s why part load efficiency is so important. The dual compressor design is perfectly suited for part load efficiency because the biggest savings are realized when a half-size compressor is operating on a full size set of shells. Adding variable frequency drives will increase efficiency even more. When comparing two single compressor machines with one dual, a 20% energy savings is common with most load profiles.

Dual Compressor Centrifugal Chillers Features that give you performance advantages Positive Pressure R-134a Design Sustainable performance for the life of the chiller No refrigerant phase-out or availability issues Eliminates annual oil change or filter replacement No purge unit required Gear Drive Compressor Quiet operation Extremely low vibration Extended durability with unique hydraulic bearings MicroTech II Controls Microprocessor for each compressor for redundancy For stand-alone operation or integration with a building automation system Protocol Selectability feature for easy integration using BACnet, LonTalk or Modbus protocols Spring-Actuated Oil Reservoir Safe compressor coastdown Protects bearings from damage after a power failure Service Friendly Design Refrigerant charge stored in condenser for easy servicing One compressor operates while the other is serviced Valves isolate each compressor Variable Frequency Drive Option Improves part load energy efficiency Reduces annual energy costs VFD provided for both compressors for added efficiency and redundancy Smaller Footprint of One Dual Chiller vs. Two Separate Chillers Increases usable space in the building Eliminates one set of service clearances Can eliminate one set of pumps Superior Unloading Unique thermal expansion valves optimize refrigerant flow Moveable discharge geometry reduces the surge point for greater stability Unit unloading to 5% prevents compressor cycling Quiet Compressor Design Unique refrigerant injection system absorbs sound energy Movable discharge geometry increases stability at low loads Reduced sound levels at part load Single Refrigerant Circuit Superior part load efficiency Improved capacity - up to 60% of unit capacity with one compressor operating Unique motor cooling system prevents circuit contamination Extended five-year motor protection warranty (contact representative for details) Reduced footprint saves installed costs

Efficient R-134a Refrigerant Designed for Sustainability With McQuay s positive pressure design utilizing R-134a refrigerant, performance is sustainable for the chiller s life. In positive pressure designs all components operate above atmospheric pressure. In contrast, negative pressure designs using refrigerants such as R-123 have some components that operate in a vacuum. This vacuum allows air and moisture to seep into the refrigeration cycle, which can significantly hurt performance. Removing air and moisture from a negative pressure chiller requires a purge system consisting of a small compressor, condenser and storage tank. This purge system can add substantial maintenance costs to a chiller system. McQuay's dual compressor centrifugal chiller gives you the following benefits The chiller does not require a purge system, lowering your maintenance costs, increasing reliability and lowering operating costs. The positive pressure design eliminates leakage of moisture or air into the chiller providing efficient performance that is sustainable for the life of the chiller. It uses environmentally friendly R-134a refrigerant which has no scheduled phase-out date, which can lower your costs because of the longer availability compared to R-123 refrigerant. It does not require "off cycle" heating equipment, which eliminates power consumption when your unit is off, saving operating costs. It does not require annual oil or filter changes, lowering your maintenance costs. A McQuay dual compressor centrifugal chiller provides quiet operation and energy cost savings for Harbor Point Condominiums in Chicago. R-134a has an A1 safety rating (lower toxicity) in ASHRAE Standard 34 compared to a B1 rating (higher toxicity) for R-123 chillers. R-134a is safer and less toxic. DesignTools ENERGY ANALYZER Version 3.0 2002 McQuay International, www.mcquay.com An Impressive Payback Over the life of the chiller system, one McQuay dual compressor chiller can provide impressive energy cost savings compared to two single compressor chillers. Look at the example of a four-story high school located in Phoenix, Arizona which has a fan-coil system with make-up air. Based on the total utility cost savings over a 25-year life cycle, the McQuay dual compressor chiller would have a simple payback of four years. How much money would you save? The McQuay Energy Analyzer software program can compare life cycle costs of one dual compressor chiller versus a single compressor chiller. Call your McQuay representative for an energy analysis and see what your payback would be.

Dual Compressor Centrifugal Chillers Flexible Solutions Efficiency. The McQuay dual compressor centrifugal chiller leads the industry in part load efficiency. Installed Cost Savings. A dual compressor chiller can mean installed cost savings of up to 35% compared to installing two separate single compressor chillers. Reliability. These chillers provide more system backup in nearly half the space. And you have all critical components times two! Environmentally Friendly. McQuay dual compressor chillers use R-134a, the ozone-safe, operator safe, refrigerant. Controls Flexibility. MicroTech II controls with our Protocol Selectability feature allow easy integration to your building automation system of choice using open, standard protocols such as LonTalk, BACnet or Modbus. Less Maintenance. No purge system, no annual oil change or filter replacement. McQuay International delivers engineered, flexible solutions for commercial, industrial and institutional HVAC requirements with reliable products, knowledgeable applications expertise and responsive support. McQuay products and services are provided through a worldwide network of dedicated sales and service offices. McQuay is your source for value-added HVAC systems including Centrifugal, Screw and Scroll Compressor Water Chillers (10-2700 tons), Evaporative Cooled Chillers (60-240 tons), Packaged Chiller Plants, Applied Rooftop Systems and Rooftop Air Handlers (15-135 tons), Skyline Outdoor Air Handlers (900-25,000 cfm), Vision Customized Air Handlers (900-50,000 cfm), Vertical Self-Contained Floor-by-Floor Units (15-125 tons) Unit Ventilators, Fan Coils, Water Source Heat Pumps and Packaged Terminal Air Conditioners. For more information or the name of your local McQuay representative, call 1-800-432-1342 or visit www.mcquay.com. 2003 McQuay International (800) 432-1342 www.mcquay.com A/SP WDC (04/03)