NEW CHILLER SCHEDULE

Similar documents
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC N-407 Air-Cooled Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Call us today! (800)

MAC-120HE-03 Air-Cooled Chiller

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Call us today! (800)

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Call us today! (800)

Submittal Summary Page

MACH N-407 Heat Pump Air-Cooled Chiller

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

C13-Series Engineering Guide

PACKAGED AIR COOLED Product Data Catalog

RECORD SUBMITTAL COVER SHEET

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

VertiCool Aurora Engineering Guide

TECHNICAL SPECIFICATIONS

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

VariCool VAV Engineering Guide

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

CoolSpot Engineering Guide

CONTENTS. B. System Design and Performance Requirements

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

TECHNICAL SPECIFICATIONS

DESIGN STANDARDS SECTION 15600

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

.2 Section Waste Management and Disposal.

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Commercial High-Efficiency Condensing Units

SpaceKeeper Console (SKC)

Product Data. AquaSnap 30RAP Air-Cooled Chillers with Puron Refrigerant (R-410A) 50/60 Hz. 10 to 150 Nominal Tons (35 to 528 Nominal kw)

Advance Release September 2009

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Split System Condensing Units and Remote Chillers

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

SKYPAK II, 3 Ton Series, gives you a

GREEN REFRIGERANT R-410A

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

SECTION AIR COOLED WATER CHILLERS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

30GN FLOTRONIC II AIR-COOLED CHILLERS

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Owners Manual Refrigerated Air Dryer MHT SERIES

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

WALL-MOUNT HEAT PUMPS - (60HZ)

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Energy-Saving Industrial Water Chillers

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

JCseries EVAPORATIVE CONDENSER. engineering data

30GT FLOTRONIC AIR-COOLED CHILLERS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

SKYPAK II, 3 Ton Series, gives you a

TOSHIBA AIR CONDITIONING

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

FORM EG6 (513) Model YLAA Air-Cooled Scroll Chillers with Brazed Plate Heat Exchangers Style B TON kw 60 Hz R-410A

Air conditioning 23XRV

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

R4H4. Product Specifications

ATTACHMENT B SECTION SPECIAL CONDITIONS

Water-Cooled Self-Contained Units

Assessment Schedule - TS8

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

The ultimate fresh air solution.

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Transcription:

TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and supervision required to accomplish the following: General description The contractor shall replace the McQuay chiller Model Number: AGR095AS27, Serial Number: 58K8127201 located at building HP502. Detailed requirements and specifications The contractor shall remove and dispose of the existing 90 ton chiller and provide and install an air cooled chiller to the following specifications and installation requirements: NEW CHILLER SCHEDULE UNIT MARK 2 CAPACITY @ 95 F -2%,+10% 90 tons/175 GPM MIN. EFF. IPLV 13.2 P.D. FT. HD. E.W.T. 52 F L.W.T 42 F COMP. TYPE SCROLL OR SCREW REFRIGERANT CIRCUITS DUAL CAPACITY MODULATION VARIABLE CAPACITY MODULATION OVER ENTIRE OPERATING RANGE ELEC. 460V/3PH Additional Chiller Specifications: 1. Liquid, suction and discharge service valves. 2. Replaceable core filter drier on each refrigeration circuit. 3. Each compressor shall have individual service valves for isolating compressor from the refrigerant circuit. 4. Integral GFCI convenience outlet. 5. Machine controller default language shall be English. 6. Phase monitor to include: a. Phase imbalance b. Over/under voltage c. Phase loss d. Delay on break timer to delay automatic restarts e. Non-critical fault delay f. Programmable auto-manual restart g. Load and line side monitoring 7. Ambient controls for operation down to 35. F.

8. Factory installed Louvered coil guards. 9. Compressor access guard(s). 10. Condenser coil shall be treated with factory/field applied protective coating meeting ASTM B-117 3000 standard. (American Society for Testing and Materials (ASTM) B 117 (neutral salt fog) for 3000 hours). 11. Heat tracer protection for piping and evaporator/chiller barrel freeze protection. 12. Control panel shall have access to micro processor (controller) for viewing or setup, without interrupting machine operation. Hinged control panels are desired. 13. Control power transformer. 14. Single point power connection. 15. Factory start-up w/report. Start up data to be added with permanent marker to inside chiller control panel. 16. First year compressor labor warranty. 17. Five year compressor warranty (parts). 18. Replace unit service electrical safety disconnect switch with blade type, fused, and sized to accommodate specifications of new chiller. Construction Notes 1. Demo and dispose of existing McQuay chiller, S# 58K8127201. The chiller shall become the property of the contractor and disposed of at the contractor s discretion. 2. Provide and install new air cooled chiller to provided specifications. 3. Chiller shall be mounted on vibration isolators with level adjustment. 4. Welding is not permitted on chillers. Water connections shall be by grooved fitting or flange. Provide Y type strainer on chill water inlet. Mesh size for strainer shall be determined by manufacturer. Generally, plate and frame, 40 mesh unless otherwise specified. 5. Re-insulate supply and return chilled water piping from isolation valves to chiller connections. 2 polyisocyanurate or cellular glass equivalent insulation w/metal jacket on all exposed piping. 6. Mechanical flow switch (paddle type) in chilled water discharge (outlet) water line shall be in series with safeties/controls whether onboard electronic factory installed flow switch is provided or not. Flow switch shall be rain tight or vapor proof and shall be set for minimum chill water flow. Existing flow switch may be re-used. 7. Strict adherence to manufacturer s installation instruction manual shall be followed with special attention to references to evaporator chilled water pump s necessity to be controlled by the chiller output (if required). 8. If building automation controls are in place on demo ed chiller, they shall be reinstalled on the new chiller and made operable. 9. Provide ¼ P/T ports on supply and return water pipe lines. Replace Chiller at HP-502 2

GENERAL REQUIREMENTS: SUBMITTALS: 1. Provide installation, start up and maintenance manuals for new equipment. 2. Complete and submit a MAXIMO Equipment up-date form for each piece of newly installed equipment. 3. Provide manufacturer specifications for proposed chiller with quote. 4. Provide material lead time with bid proposal. 5. Provide Factory start-up report. SPECIAL SCHEDULING AND ACCESS: None identified. SPECIAL CONDITIONS: None Identified HAZARDOUS MATERIALS: None Identified ENVIRONMENTAL: 1. All EPA regulations concerning ozone depleting refrigerants shall be followed in the performance of this contract. Replace Chiller at HP-502 3

MAXIMO Equipment Update Form Data Collector: Phone: Date: / / Bldg: Specific Location: * AC, Computer Room * Heat Pump, Package * AC, Package * Heat Pump, Package Terminal * AC, Package Terminal * Pump, Chilled Water Assembly, Trap line * Pump, Circulating, Domestic Water * Backflow Preventer * Pump, Circulating, Dual Temp Water * Chiller, Air Cooled Recip * Pump, Circulating, Heating Water * Chiller, Air Cooled Screw * Pump, Condensate * Chiller, Air Cooled Scroll * Pump, Condenser * Chiller, Water Cooled Recip * Pump, Sump * Chiller, Water Cooled Screw * Regulator, Temperature * Compressor, Control Air * Tank, Hot Water Storage * Compressor, Industrial Air * Tower, Cooling * Dryer, Refrigerated Air * Unit, Air Handling * Exchanger, Heat * Unit, AC Condensing * Evaporator, Freezer * Unit, Freezer Condensing * Evaporator, Refrigerator * Unit, Refrigerator Condensing * Fan, Exhaust * Unit, Fan Coil * Furnace, Oil Unit, TAB (Attach Room No. List) Heater, Space Unit, VAV (Attach Room No. List) * Heat Pump, Geo-Thermal Valve, Pressure Reducing * Heat Pump, Indoor Unit Valve, Steam Pilot * Heat Pump, Outdoor Unit * Water Heater Other Demolished/Removed Equipment Maximo no: N/A Ser no: N/A New/Replacement Equipment Manufacturer: Model no: Ser no: Type: Elec Oil LP Gas Nat Gas Steam Hot Water Motor Data: HP Volts Phase RLA RPM Frame Tons No. of Motors no. of Belts Belt size(s) CFM KW Refrig type Refrig Qty Filter Size(s)