The A-series Eletta Flow Monitor with local indication and analog output

Similar documents
Gas cylinder scale Model GCS-1

/8 DIN Level Indicator

Portable central unit for several parameters

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Low Temperature Zirconia Oxygen Analyzer

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Temperature Solutions Line Card

WIO200 Water In Oil measuring instrument

NT DUAL CHANNEL DISPLAY. User Guide

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Toroidal Conductivity Transmitters Series APT4000 Specifications

OPTISENS TUR 2000 Technical Datasheet

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Ultrasonic Point Level Switches

PT9420 (Extended Range)

UDC100 Universal Digital Controller Specifications

Model Q45P/R. ph/orp Monitor...

Figure 1 DirectLine DL423 Sensor. Description, continued

Software Version 2.01 LEVEL MONITOR MODEL 220

Model Q45P/R. ph/orp Monitor...

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

I/A Series 716C 1/16 DIN Temperature Controller

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

for relative humidity and temperature

Ultrasonic Switches. Features & Benefits

continuous emissions monitoring Combustion & Environmental Monitoring

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Inductive Conductivity

Electronic Flow Switches

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Enraf Servo Gauge 854 XTG

Model D12-IR. Digital Gas Transmitter...

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

MEAS CAL ALARM WASH CONF APT4000 TC

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Temperature Controllers

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

WH EN IGH T T C LO SED

SECTION Fluorescent Dissolved Oxygen Measuring System

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Druck DPI 705/DPI 705 IS Series

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

THERMODYNAMIC STEAM TRAP

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Process Instrumentation. Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens.

for relative humidity and temperature

PARTICULATE EMISSION MONITORING

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

The next generation thermometer from the global leader

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Dräger Polytron 7000 Fixed gas detector

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Level Measurement Continuous level measurement Ultrasonic transmitters

Automatic Isokinetic Sampler ST5

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

EC FX NH3. A new and improved approach to ammonia gas detection

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Enraf Servo Gauge 854 ATG

MultiFix Central unit

Beck. The differential pressure transmitter for air

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Allure EC-Smart-Air Series Communicating sensors

Commercial and Light Industrial Fire Alarm Control Panel

Sitron s CF Line of Flow Switch Monitors

Speed and Frequency Seite 1 von 7

Integrated Automation

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Comfort. Description. Applications

Dräger PointGard 2100 Detection of toxic gases and vapours

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Dissolved Oxygen Measurement liquisys M COM 223 / 253

METEOROLOGICAL INSTRUMENTS

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

SIHI Dry GD S Sizes S450, S650

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Continuous level measurement Ultrasonic transmitters

MODEL WIND TRACKER

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Transcription:

The A-series Eletta Flow Monitor with local indication and analog output

GL series FA series GSS series FSS series The Pipe Section is constructed of copper alloy and fitted with BSP/NPT threads from 15 mm to 40 mm ( 1 /2 1 1 /2 ). The Pipe Section has a flanged (wafer) process pipe connection and the material is bronze from 15 mm up to size 40 mm ( 1 /2 1 1 /2 ) and painted cast iron in sizes 50 mm to 400 mm (2 16 ). The Pipe Section is made from Stainless Steel and comes with BSP/NPT threads in size 15, 20 and 25 mm ( 1 /2, 3 /4 and 1 ). The Pipe Section comes in stainless steel and has the same fit between flanges (wafer) execution as the -FA series and process connections from 15 mm to 500 mm ( 1 /2 20 ). Benefits of the A-series The A-series Flow Monitor Modular design Rugged and sturdy design Uses proven differential pressure technique Economical alternative to more expensive flow meters Liquid and gases can be monitored Local alarm and indication of flow through 20 segments LED bar graph Remote alarms and remote reading of flow 4 20 ma Measures 1:2 and 1:5 flow range with +/- 5% F.S accuracy Important applications and product features Monitoring flows in cooling and lubricating circuits Can measure both liquids and gases Antifreeze protection of heat pump systems Low cost solution for difficult flow applications Dry out protection Interchangeable control units to fit all pipe sections The Eletta Flow Monitor s function is based on the proven and dependable differential pressure principle. This is perhaps the oldest and most widely used principle for flow metering, mainly because of its simplicity and its relatively low cost. The A-series takes advantage of the Eletta proprietary robust and sturdy design. It combines the long proven mechanical function with an electronic circuit board, which gives a 4-20 ma linear output signal and a local indication from a 20 segments LED bar graph. The A-series also has two integral adjustable alarm relays. Each of the adjustable relays can be adjusted to trip anywhere within the measuring range of the monitor for high/low alarm. The design gives a highly repeatable output signal that often excludes the need of more accurate flow meters. In all, this makes the A-series one of the most complete and versatile of our products. The A-series comes in two measuring ratios designated A2 and A5, which means that the A2 has a measuring span of 1:2 and the A5 has a span of 1:5. Like all Eletta Flow Monitors the A-series can monitor both liquids and gases. All the Eletta Flow Monitors including the A-series can be fitted to any of the various Eletta Flow Monitor Pipe Sections to suit your application. As the control unit is pre-calibrated before leaving our production facilities, you can change pipe sections to fit other dimensions and materials than originally ordered. The Instrument consists of two parts mainly, i.e. the Pipe Section and the Control Unit. The Pipe Section is the part that is to be mounted in the process pipe and the Control Unit is mounted directly (standard) or remote to the Pipe Section. The Control Unit contains the electrical circuit board which is giving you the Flow information through the analog outputs, 4-20 ma and the dual alarm relays. The Pipe Sections come in Copper alloy, Stainless Steel, painted Cast Iron and sizes from DN 15/PN16 (ANSI 1/2 /150 lbs) up to DN 500/PN16 (ANSI 20 /150 lbs). The A-series Control Unit can also be used to upgrade an already installed Eletta Flow Monitor such as the S-, V- or R-series. Starting and stopping pump motors Measurement not affected by static pressure

Flow range: Wetted materials: Rubber parts: Max. pressure: Standards: Max temp. Control Unit: Max temp. Pipe Section: Enclosure: Process Connection: Power supply: Relay contacts: Outputs: 0,4 25 000 l/min (liquid) Specifications Copper alloy, painted cast iron. GSS: seaworthy stainless steel 904L, FSS: stainless steel, 316 Nitrile (HNBR), EPDM and Fluorinated rubber (FPM) 16 bar (232 PSI) DIN PN 16/ANSI 150 lbs 65 C (150 F) -GL and -FA: 120 C (248 F) -GSS, -FSS: 250 C (482 F) IP65 (NEMA4) DN 15-40, BSP/NPT thread DN 15-500 DIN/ANSI flange (wafer) 24 VDC+/-10% Max. <50 V AC/DC Min. 0,1VDC, 10 ma Max switching power: 1750 VA, 210 W Isolated analog current 4-20 ma, 1000 ohm, zero-based 51B1E10 Recommended cable: Shielded twisted pair min. 0,2 mm 2 (0,0031 inch 2 ) Accuracy: Repeatability: Current consumption: CE-approvals: < +/-5% F.S < 2% actual max 100 ma The Eletta Flow Monitors conforms with the EU directive for low voltage no: 72/23/EEC (EN 60 204-1, Part 1.) and Electromagnetic compatibility according to the directive 89/336/EEC (EN 50081-1 and 50082-2) Complies with applicable parts in PE-Directive 97/23/EG Eletta Flow Monitors The name Eletta has become synonymous with flow monitoring in many industries world wide where the Products are appreciated for their sturdy and robust design. Eletta Flow Monitors are of our own proprietary design and our manufacturing as well as the whole company is certified to ISO 9001 and ISO 14000 quality standards. We export our Products all over the world and we have Authorized Distributors in most European countries, Australia, South Africa, India, Japan and USA. Find out more In our technical leaflets and manuals you will find full details of the design, pressure drop graphs, measuring ranges and dimensional drawings. We welcome you to our at all time updated web site at www.eletta.com for the most recent and accurate information about Eletta and our Products. At this site you can find most of the documentation on down-loadable files. Whatever your request for information is, our e-mail address: info@eletta.com is the fastest way to get in contact with our Customer Support and technical department. Of course, your local Eletta Distributor, whose address you can find in our homepage, can assist you in most cases. Eletta Flow AB Box 5084, SE-141 05 Kungens Kurva, Sweden Tel. +46 8 603 07 70 Fax. + 46 8 646 10 40 info@eletta.com www.eletta.com

Measuring Ranges Eletta Flow Monitors D2, V1, S02, S2, R2 and A2 D5, V15, S05, S25, R5 and A5 MC = Measuring Constant It is possible to order a lower measuring range than indicated Eletta Flow AB Box 5084, SE-141 05 Kungens Kurva, Sweden Tel. +46 8 603 07 70 Fax. + 46 8 646 10 40 info@eletta.com www.eletta.com 130B3E12

and Dimensions D, R, V- GL D, R, V- FA D, R, V- GSS D, R, V- FSS A, S- GL A, S- FA A, S- GSS A, S- FSS 130B4E12 Width see table *Approximate weight