RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

Similar documents
HE365A,B Powered Flow-Through Humidifier with

HE365A,B Powered Flow-ThroughHumidifier with

HE360A,B Powered Flow-Through Humidifier

HE360 Powered Flow-Through Humidifier

HE365A,B Powered Flow-ThroughHumidifier with JI

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

HE420A Steam Power Humidifier

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

HEALTHY CLIMATE HUMIDIFIER

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

Owner s Manual For Models 400, 500, 600 & 700

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

Owner s Manual. Humidifiers. For Models 350, 360, 400, 400M, 500, 500M, 600, 600M, 700 & 700M

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

MODEL HUM HUMIDIFIERS

Owner s Manual. For Models 350, 360, 400A, 500A, 500M, 600A, 600M, 700A & 700M. Includes Safety & Operating Instructions and Warranty Information

READ AND SAVE THESE INSTRUCTIONS AUTOMATIC HUMIDIFIER. The Best Cure For Dryness OWNER S MANUAL FOR MODELS 448, 558, 568, 600, & 700

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

HE220, HE260 Humidifier Installation Kit

HE360 Humidifier Installation Kit

Residential Steam Humidifier

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

FLOW-THROUGH FURNACE HUMIDIFIER

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

UNDER CABINET RANGE HOOD

user manual Model #: BLZ-WVH-42

Comfort, Energy & Health Solutions

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS. The Best Cure For Dryness OWNER S MANUAL

Steam Humidifier Fan Pack Installation & Maintenance Instructions

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Automatic Humidifiers

Must be installed by a trained, experienced technician

FLOW-THROUGH FURNACE HUMIDIFIER

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

e Bath Fan with Light User s Guide

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

ACCESSORY ITEMS FOSSIL FUEL KITS RXPF- SERIES. Model RXPF-F01 Model RXPF-F02

breeze easytm model # F100-1W

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

e Bath Fan with Light User s Guide

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Installation & Operating Guide

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Use, Care, and Installation Guide

Installation Instructions Owner s Manual

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Ultrasonic Humidifier

G-100ES Duct Mount Humidifier

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Wiring Instructions. High-Capacity Steam Humidifiers

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

energy-saving tips for all seasons

T8602C Chronotherm IV Deluxe Programmable Thermostats

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

EZ-Topper Tall, Single

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

G-100ES Duct Mount Humidifier

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Operator: Save these instructions for future use!

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

installation and operation manual for Hunter Ceiling Fans

OIL FURNACES PREMIUM CLASS UPFLOW OIL FURNACES. ROBF- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to kw]

Summer Breeze Heater Service Manual

EZ-Topper. Tall, Single. Tall, Twin. Thank You MODEL: EZT MODEL: EZT-S

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Installation Instructions

FRYMASTER TCF. Chicken Fryer

Transcription:

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers with Antimicrobial OWNER S GUIDE Place bar code here 69-2297-01

IMPORTANT Please read these instructions and keep them in your records. OPERATING YOUR HUMIDIFIER Humidifiers are controlled by the Convertible Humidity Control. The convertible humidity control is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on your humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing moisture condensation on your windows. The table below can also be used to adjust humidity control to the recommended setting. M29011 At Outside Temperature Recommended Control Setting At Outside Temperature Recommended Control Setting -20 F (-29 C) 15 +10 F (-12 C) 30-10 F (-23 C) 20 +20 F (-7 C) 35 0 F (-18 C) 25 Above 20 F (-7 C) 40 NOTE: As outside temperature drops, the recommended humidity control setting is lowered to adjust for effects of dewpoint. These settings should reduce accumulation of moisture and ice on your windows and other areas of your home. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on your windows. NOTE: If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. HOW YOUR HUMIDIFIER WORKS Your humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises. Your humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that dispenses water evenly over the antimicrobial humidifier pad. The warm dry air, from the furnace, passes over the humidifier pad and picks up the moist air to circulate it throughout your home. 69-2297 01 2

Humidified air feels warmer and more comfortable so you may be able to lower your thermostat heating setpoint, which saves money on your heating fuel bills. The end result is that your humidifier gives you a cleaner, more comfortable environment that is also energy efficient. MAINTAINING YOUR HUMIDIFIER A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home. Frequency of cleaning depends on the condition of your water. You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. For optimum performance, replace the antimicrobial pad once a year. Use the following procedure to clean your humidifier. WARNING Serious Personal Injury Hazard. Can cause electrical shock and injury from moving parts. Disconnect power and shut off water supply before removing cover. IMPORTANT: Never oil any part of the humidifier. Every 1 to 3 Months (Depending on Water Quality) 1. Disconnect power and turn off humidifier water supply. 2. Remove the humidifier cover by unplugging the connector and loosening the thumb screw. Grasp the cover near the bottom and pull toward you. 3. Remove humidifier pad assembly from humidifier by grasping top of tray and pulling it toward you. 4. Lift the tray off the pad. 5. Gently pinch water nozzle catches inward until you can lift water nozzle off tray. WATER DISTRIBUTION TRAY WATER FEED NOZZLE ANTIMICROBIAL HUMIDIFIER PAD ASSEMBLY HUMIDIFIER HOUSING WATER FEED TUBE SIDEWALL COVER BYPASS SIDEWALL M29012 3 69-2297 01

6. Carefully remove any mineral deposits from tray and frame. Be sure frame drain hole is not blocked. 7. Disconnect drain hose from drain fitting on the bottom of the humidifier housing. 8. Clean the drain fitting, if necessary. 9. Bend the drain hose to loosen any mineral deposits. 10. Flush the drain hose with pressurized water (a running tap) to clean the hose. 11. Reattach the drain hose to the drain fitting. 12. Snap the water nozzle back on the tray.763-954-4569 13. Be sure the marked end of the pad is facing up. Place the tray on the new pad. 14. Place humidifier pad assembly in humidifier housing. Be sure water feed tube is placed in guide slots. 15. Replace the humidifier cover. 16. See checking your humidifier operation on page 4. to verify operation. End of Humidification Season Clean the humidifier and shut it off at the end of the heating season. See Every 1 to 3 Months section, steps 1 through 15, to shut down for the season. IMPORTANT: Be sure humidifier power is off. VACATION The humidifier water supply and your humidity control can be turned off. Turn on humidifier water supply and reset your humidity control when you return. CHECKING YOUR HUMIDIFIER OPERATION After winter startup or servicing, check the humidifier operation: 1. Turn on the humidifier power and water supply. 2. Turn the Convertible Humidity Control to highest setting; set thermostat to 10 F (6 C) above room temperature. 3. Observe that water is flowing out of the drain hose. NOTE: The furnace blower must be on to activate the humidifier. 4. Reset thermostat and Control to comfortable setting. 69-2297 01 4

TROUBLESHOOTING YOUR HUMIDIFIER Problem What to Look for What to Do Low humidity High humidity Furnace blower not operating. Rapid air changes. Drafts (cold air is dry and is an added load to humidifier). Condensation on walls. Heavy condensation on windows. Reset circuit breaker or replace fuse. Check that the furnace power is on. Check all external wiring connections. Check humidity control setting. Call a heating contractor. Keep doors and windows closed. Close fireplace damper if not using. Minimize exhaust fan running time. Seal around doors and windows. Turn off humidity control and water until condensation is completely evaporated. Turn humidity control low enough to eliminate bath and cooking condensation moisture. If moisture persists, more ventilation is needed. 5 69-2297 01

LIMITED FIVE-YEAR WARRANTY 5 years from date of purchase (contact the Rheem Parts Distribution Center for more information). 69-2297 01 6

7 69-2297 01

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 In keeping with its policy of continuous progress and product improvements, Rheem reserves the right to make changes without notice. U.S. Registered Trademark 2008 69-2297 01 M.S. 12-08