MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

Similar documents
Outdoor Mall Elmira Maple Syrup Festival 24 Church Street West Elmira, ON. N3B 2Z6

MOBILE FOOD VENDING Food Trucks & Trailers

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

FIRE DEPARTMENT PERMIT GUIDELINES

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Dear Concessionaire,

WARNING SYMBOLS CHECKLIST (CRAFT)

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Fuels Safety Program. Gaseous Fuels Code Adoption Document Amendment

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

CBO-750 HYBRID-R OVEN Instructions Manual

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OFFICE of the FIRE COMMISSIONER. Recreational Vehicles Life Safety Requirements

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

Note: The event coordinator is responsible for compliance of all regulations.

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Jacqueline Wilmot Fire Protection Engineer NFPA. Road Map for Mobile Food Truck Regulation

Note: The event coordinator is responsible for compliance of all regulations.

OPERATING INSTRUCTIONS AND OWNER S MANUAL

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Repeat procedures for other side.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

CYLINDER NOT INCLUDED

EXCELSIOR FIRE DISTRICT

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

OUTLINE FOR FIRE PREVENTION ACTIVITY

OPERATING INSTRUCTIONS AND OWNER S MANUAL

BUILT IN UNIT INSTRUCTION GUIDE

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Using it in an enclosed space can kill you.

DESIGN CLASS FUNCTION

WARNING. SPECIFICATIONS: Completely Self-contained Rain Protected Wind Resistant No Electrical Required WARNING FOR OUTDOOR USE ONLY!

gas Understanding Gas Appliance Conversions READ ALL INSTRUCTIONS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

DESIGN CLASS FUNCTION

EVALUATION SUBJECT: FIREPLACES DIVISION: SPECIALTIES SECTION: FIREPLACES AND STOVES. Report Holder:

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

A. Product Data: Include rated capacities, furnished specialties and accessories.

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

FOOD PREPARATION WITHIN EXHIBITS

PORTABLE PROPANE HEATER

South Elgin & Countryside Fire Protection District

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

Direct Fired Heater Model AD Specification

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

CASUAL FIRESIDE TM A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Table Top Patio Heater

GAS COOKTOP INSTALLATION INSTRUCTIONS

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

ADF/ADFH 300 and 500

TAMUCC Fire Safety Training

PAULIN PRODUCTS INDOOR HEATER

Department of Public Safety

Owner s Guide Installation & Operation

USE AND CARE GUIDE PEDESTAL FIREBOWL

Wok Cookers Instruction Manual

MODEL: CGG-306 Chef s Style Portable Tabletop Grill ASSEMBLY AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

Viking Installation Guide

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

INSTALLATION GUIDE Dual Fuel Ranges

Saturday, September 9 th 2017 ***** NO PETS ALLOWED

Service Parts, Kits and Accessories

FEATURES AND BENEFITS

ASSEMBLY INSTRUCTIONS

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

Gas Cooktop Installation, User and Service Instructions GMS 955.1

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

GAS APPLIANCE LISTING PROGRAM

LENTEK WARRANTY. Directions For Use

Transcription:

Page: 1 of 5 The following will outline the information and material required to process the Field Approval of Mobile Food Service Equipment (MFSE). 1. Type of MFSE. See Page 2. 2. Equipment Identification Number such as a licence plate number, V.I.N. or a unique model or serial number assigned to the equipment. See page 2. 3. A list of all gas fired appliances installed. (Note: The appliances must bear the certification mark from a recognized certification body or they will require a separate Field Approval.) Provide the Manufacturer, Model Number, Appliance Type, Serial Number and Input Rating. You may use the table on page 2 to record this information. 4. A list of the propane components used from the propane cylinders to the appliances Provide details of the Manufacturer and Model Number of components such as regulator, gas hose assemblies, automatic valves and manual valves. You may use the table on page 3 to record this information. 5. A sample of the Danger labels to be used as required by Section 10 of the Engineering Review Requirements for MFSE. See attached sample on page 4. 6. A drawing or sample of the General Rating Plate as required by Section 11 of the Work Instructions for MFSE. See attached sample on page 5. 7. A floor plan or overall assembly drawing showing the general layout of the equipment and the location of the appliances and propane cylinders or tank. 8. If used, details of the exhaust fan and interlocking air flow proving switch and automatic gas shut-off valve and a simple diagram showing the wiring connections. Note: A mechanical exhaust system interlocked with the fuel supply line is required if fuel burning equipment is operated within an enclosed space of an MFSE. 9. If possible, please provide some photos of the equipment to illustrate the basic design, piping, propane supply and appliances. 10. Details of the size and location of combustion air supply and make-up air supply for the vehicle. 11. For any MFSE with electrical features rated at greater than 30 volts, please ensure that the required approval under the Electrical Code has been obtained before our inspection. The only evidence of such approval acceptable to TSSA will be a label attached to the appliance. The label must be issued by a field evaluation agency recognized under the Ontario Electrical Safety Code and Ontario Regulation 438/07. The inspection must be for the control panel(s), and the wiring to and from the panel(s). If the ESA performs the inspection, then the label must have a serial number starting with a letter S. For further details please contact the Electrical Safety Authority at 1-800-ESA-SAFE.

Page: 2 of 5 Please complete the following information and return with the Application for Field Approval. 1. Type of MFSE Self-Propelled Vehicle Trailer Portable Cart Other Specify 2. Equipment Identification Number This may be a licence plate number, V.I.N. or a unique model or serial number assigned to the equipment. 3. Please record information for all gas fired appliances used. Manufacturer Type Model Number Serial Number Input

Page: 3 of 5 4. Please record information on the components used. Propane Gas Components - 100 # Cylinders COMPONENT MAKE MODEL NUMBER Regulator Gas Hose Assembly CSA or cul Certified Assembly Fire Suppression Automatic Valve Air Flow Interlock Automatic Valve Manual Valves Appliance Connectors Air flow Proving Switch Exhaust Fan Propane Gas Components 420# Cylinder COMPONENT MAKE MODEL NUMBER Regulator Gas Hose Assembly CSA or cul Certified Assembly Fire Suppression Automatic Valve Air Flow Interlock Automatic Valve Manual Valves Appliance Connectors Air flow Proving Switch Exhaust Fan

Page: 4 of 5 SAMPLE DANGER LABELS The following danger labels shall be affixed to all MFSE, be readily visible and located adjacent to the propane container with the following wording: DANGER Cooking appliances shall not be used for space heating. When the propane appliance is not in use or the vehicle is stored, shut off the supply of propane to the appliance (at the propane tank). BEFORE TURNING ON PROPANE Make certain all propane connections are tight, all appliance valves have been turned off and any unconnected outlets are capped If an open door is used for ventilation/combustion air, ensure the door is open before turning on propane AFTER TURNING ON THE PROPANE Light all pilots of appliances to be used. Each connection, including those at appliances, regulators, and cylinders, shall be leak tested initially and periodically with soapy water by the operator. Never use a lighted match or other flame when checking for leaks. Do not leave a system turned on or containers connected until the system has been proven to be leak (propane) tight. When the containers are disconnected, the propane supply line shall be capped or plugged. For all MFSE that are part of a Self-propelled Vehicle, the following additional danger label shall be affixed at the vehicle s fuelling point and inside the driver s compartment with the following wording: DANGER All pilot lights shall be extinguished and the supply of propane shut off before refueling this vehicle. For Carts with Self-Contained Propane Supply System the following additional statement shall appear on the label. For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors The word DANGER shall be a minimum of ¼-inch (6.4 mm) in height. All other words on the label shall be a minimum 1/8-inch (3.2 mm) in height.

Page: 5 of 5 SAMPLE RATING PLATE General Rating Plate Applicant s Name Address Mobile Food Service Equipment Identification Number (V.I.N., Model No., Serial No., or Licence Plate) Appliances Manufacturer Type Model Number Serial Number Input For Use with Propane Gas Manifold Pressure: in. w.c. Electrical Rating: Design Standard: Volts, 60 Hz, amps TSSA-FA-2012