LD-5010 OmniDeck with WashBar 5000 Series

Similar documents
FL-2H, FL-2L Frequency Lavatory System FL-Series

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

SS-3N Express Lavatory System SS-Series

AV60 Advocate Lavatory System AV-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

AV90 Advocate Lavatory System AV-Series

SS-1N Express Lavatory System SS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

LVQD3 Verge with WashBar Technology LVQ-Series

LVQD1 Verge with WashBar Technology LVQ-Series

SS-2N Express Lavatory System SS-Series

Express Lavatory System SS-Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

AV60 Advocate Lavatory System AV-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

LVSD2 Verge Wash Basin LVS-Series

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Express Lavatory System MG-Series

Express Lavatory System MG-Series

WF2613 Classic Corner Washfountain with 9" Deep Bowl

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

LVSD2 Verge Wash Basin LVS-Series

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

SN2003, SN2023, SN2004, SN2024

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

EXQUISITE. PERFORMANCE.

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Model Z Sundara Float Double Basin Hand Washing System

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Model Z Sundara Reef Triple Basin Hand Washing System

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Terreon Lav Decks WARNING

Corporate Interiors Ideabook Handwashing Fixtures, Washroom Accessories, Toilet Partition Cubicles

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Installation Instructions OBSOLETE

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

DUKE UNIVERSITY CONSTRUCTION STANDARDS

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

PAT BASIN MODEL 9121, 9131, & 9141

A. Section Joint Sealants: Seal fixtures to walls and floors.

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

O.D / 2" (444) 15 1 / 2 " (393) Maximum I.D / 4 " (336) 1 3 / 4 " (45) 1 1 / 4 " (32)

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

HL45, HL80 Thermostatic High-Low Valves

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

LA90 DISCONTINUED IMPORTANT!

LA45 DISCONTINUED IMPORTANT!

ADA guidelines. 48" min. 30" min. 8 min. 34 max. to top of lavatory rim. 27 min. knee space to bottom of bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

LA60 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Washfountain Application Guide

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

FAUCET PARTS - EXPLODED VIEW Model: K-59

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

MERIDIAN MODEL# 3793

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

S-8720-CA-E S-8721-CA-E S-8710-CA-E S-8711-CA-E S-8700-CA-E S-8701-CA-E. Sensorflo Battery Powered Lavatory Faucet MODELS: FEATURES: COMPLIANCE:

Stainless Steel Sink Workstations

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

Tube Clamp Submittal Information Revision A: July 25, 2013

COMMERCIAL VOLUME PLUMBING

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

Transcription:

Basin(s) and Deck are constructed of Terreon or Terreon RE Solid Surface Material Decks are Pre-fabricated; Shipped Complete to the Job Site Custom and Standard Sizes Available Optional Coved Backsplash and Integral Front Apron Eliate Caulk Lines Integral bowl option creates seamless look One piece plated stainless steel WashBar includes touch-free soap, water and dryer WashBar technology intuitively guides user and eliates simultaneous activations Basin and drain engineered to evacuate water and dissipate air flow Specifications The OmniDeck Model can accommodate one or more users. Model OmniDeck with WashBar features a Terreon solid surface deck with undermount basin. The OmniDeck with WashBar comes equipped with single piece All in One WashBar, allowing users to access soap, water and a hand dryer without leaving the hand washing station. Optional aprons, splashes, mounting brackets and single-station access panels are also available to round out the total package. Construction Deck Constructed of ½" thick Terreon, a densified solid surface material composed of bio-based resin or TerreonRE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by Home Innovation Lab to meet CSA B45.5/IAPMO Z124. Terreon and TerreonRE are GREENGUARD certified as low-emitting materials. Basin The basin model WB-TR1 has been designed to direct water to a trench drain and features a 300 series stainless steel drain cap. The basin and drain cap work together to evacuate water and dissipate airflow to prevent splashing on the user or floor. The basin is constructed of Terreon solid surface and is available in all Terreon colors. Internal basin dimensions are 11-1/2" x 21-5/8" x 8-1/8". Model -2 with optional backsplash WashBar All-in-One chrome-plated stainless steel WashBar includes touch-free soap, water and hand dryer. Load tested to 500 pounds, the WashBar is secured to the basin with two anti-rotational shanks. Blue LED lights help guide the user to the WashBar, indicating the three functions. The LED light will change from blue to green to signify that the function is in use. Each function is easily identified by the corresponding icon on the WashBar's top surface. To aid in a smooth, controlled hand-washing and drying operation, sensors are programmed to eliate simultaneous activations of nearby functions. WashBar sensors are not affected by varying skin tones or darkness. Smart technology allows the facility manager or maintenance staff to clean and configure with ease. Cleaning Mode WashBar has an activation feature to put the unit into cleaning mode to allow for easy cleaning of the WashBar and basin without activating the functions. Configuration Mode WashBar also has a configuration mode to identify how many cycles are on the soap, faucet and dryer. Mode also allows for dryer speed and sound adjustment at low, medium and high levels. Soap Dispenser The soap dispenser is located on the left side of the WashBar. This eliates any soap from dripping on counters or onto the floor, imizing slip hazards and allows for easy cleaning. Choose between a foam or a liquid soap dispenser, which are compatible with most bulk soaps. Soap system accommodates up to a 1 gallon container to reduce the number of soap replacements. When the LED light above the soap function turns to a solid red, simply check the level and replace the soap container with a full container if necessary. The soap system includes an adapter to fit many 1 gallon soap containers available on the market. Please visit https://www./maintenance/soap-dispeners for soap recommendations. Faucet Faucet is located in the center of the WashBar and has a spray angle of approximately 17 degrees off the vertical. Choose either a 0.5 gpm or 0.35 gpm PCA rubber tip aerator. Maximum run time is 30 seconds. The 0.5 gpm aerator option is the equivalent to 0.25 gpc and the 0.35 gpm aerator option is the equivalent to 0.18 gpc. Automatic 5 second purge within 24 hours of the last use. Recommended operating range is 20-80 psi. Page 1 of 11 7/13/2017

Dryer The hand dryer is located on the right side of the WashBar, allowing users to dry their hands immediately after washing. This virtually eliates excess water on the floor. The dryer motor provides warm air at three speeds, high-medium-low, which can be field adjusted by placing the WashBar into configuration mode. The single sided dryer will dry hands in approximately 15 seconds depending on user preference. The decibel range with hands in air stream is 76 db (high speed) to 64 db (low speed). The dryer motor located behind the access panel, is ccsaus listed. Electrical The WashBar is powered by one 12V DC adapter that plugs directly into the dryer or electrical outlet. The Washbar and dryer motor require a properly grounded dedicated 20 amp circuit, 110V outlet. One duplex outlet is required per station to power the WashBar and dryer. Strainer and Drain Assembly System Strainer and drain assembly system comes complete with 300 series stainless steel trench drain cap and tailpiece. Optional chrome plated p-trap available. Configured with individual drain tough-in connections. Access Panel Minimalistic panel is composed of 300 series stainless steel. Plumbing components, dryer motor, and soap tank are concealed within the panel. The swing down access panel is designed to ease the maintenance process by eliating tools and only requires one person for installation. Alternatively, customers can provide their own access panel. Mounting Options Designed to be mounted utilizing 12 gauge stainless steel mounting brackets (to allow for easy install and future removal of deck). A mounting frame or cleating by others can also be used in the field. Bracket quantity is dependent on deck length. 2" to 45" = 2 brackets, 45.25" to 75" = 3 brackets, 75.25" to 105" = 4 brackets and 105.25" to 120" = 5 brackets Seag Seag is required for OmniDecks with a total length over 120". Seag is the process of joining two or more solid surface components together with an inconspicuous seam. Optional adhesive seam kits, available from Bradley, are made to match any Terreon color. Code Compliance and Certifications Standards Terreon and TerreonRE are Home Innovation Lab Certified to meet CSA B45.5/IAPMO Z124. National and International Plumbing Approval OmniDecks are Uniform Plumbing Code (UPC), International Plumbing Code (IPC) and National Plumbing Code of Canada (NPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156, CSA B45 Series & ASME A112.18.1/CSA B125.1. Standard ADA Height Mounting To comply with ADA, the rim height of the OmniDeck, and at least one basin, must be 34" (864) maximum above the finished floor and must have proper reach, knee and toe clearances. Always review local codes for compliance. Juvenile Height Mounting The juvenile height hand washing stations are designed to be mounted at 31" (787) maximum rim height to comply with ADA/TAS reaches and clearances. Enhanced Reach Mounting Per 2009 International Building Code (IBC) under 1109.2.3, if there are 6 or more lavatories, at least one lavatory shall meet the 11" (279) maximum reach depth per IC A117.1 606.5. The with WashBar is compliant when the deck depth is maximum. OBC Height Mounting The Ontario Building Code hand washing stations are designed to be mounted at a 33-1/16" (840) maximum rim height to comply with OBC reaches and clearances. To meet OBC, imum deck depth must be 20-3/4" (527). CSA Height Mounting To comply with CSA, hand washing stations must be mounted at a 33-7/8" (860) rim height with a deck depth of 21" (533). BCBC Height Mounting The British Columbia Building Code hand washing stations are designed to be mounted at a 34-1/16" (865) maximum rim height. To comply, the deck depth must be a imum of 22-1/4" (565). QBC Height Mounting The Quebec Building Code hand washing stations are designed to be mounted at a 34-1/16" (865) rim height and deck depth of 23-1/2" (597). This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ ANSI 372 meeting the Lead-Free content requirement. Certified to NSF/ANSI 372 Page 2 of 11 7/13/2017

Standard Dimensions - 1-Person Top View 13-1/2" (343) 11" (279) 3-1/8" (79) 10-3/4" (273) 5" (127) 11-1/2" (292) 21-5/8" (549) Front View 5" (127) 5" (127) 19-1/8" (485) Page 3 of 11 7/13/2017 22-1/2" (571)

Dimensions (Side View) Surface mount brackets shown. Standard Height (ADA) 10-7/8" (275) 8" (203) Juvenile Height (ADA) 10-7/8" (275) 8" (203) 34" (864) 33-1/2" (851) 27" (686) 9" (229) 14-5/16" (363) 31" (787) 30-1/2" (775) 24" (610) 9" (229) 11-5/16" (363) 17" (432) Deck depth must be imum for ADA, Enhanced Reach depth is 17" (432) Deck depth must be imum for ADA, Enhanced Reach depth is Page 4 of 11 7/13/2017

Dimensions (Side View) Surface mount brackets shown. OBC Height 20-3/4" (527) 11-1/8" (282) 8-1/16" (205) BCBC Height 22-1/4" (565) 12-5/8" (320) 9-13/16" (250) 33-1/16" (840) 28-15/16" (735) 27" (685) 13-3/4" (350) 13-7/8" (352) 34-1/16" (865) 28-15/16" (735) 27" (685) 9-13/16" (250) 7-7/8" (200) 14-7/8" (378) 11-13/16" (300) 16-15/16" (432) 19-11/16" (500) Deck depth must be 20-3/4" (527) imum for OBC Deck depth must be 22-1/4" (565) imum for BCBC CSA Height 11-3/8" (288) 7-7/8" (200) 21" (533) QBC Height 13-7/8" (352) 11" (280) 23-1/2" (597) 33-7/8" (860) 29-15/16" (760) 28-3/8" (720) 9-1/16" (230) 7-7/8" (200) 14-11/16" (372) 34-1/16" (865) 26-15/16" (685) 9-1/16" (230) 7-7/8" (200) 14-7/8" (377) 16-15/16" (430) Deck depth must be 21" (533) imum for CSA Page 5 of 11 7/13/2017 16-15/16" (430) Deck depth must be 23-1/2" (597) imum for QBC

Minimum Dimensions for Custom Dimensions -1 Dimensions 10-3/4" (273) 15" (381) * 14-1/2" (368) ** -2 Dimensions 10-3/4" (273) 15" (381) * 14-1/2" (368) ** *with side apron **with side splash or no side apron Page 6 of 11 7/13/2017

Minimum Dimensions for Custom Dimensions -3 Dimensions 10-3/4" (273) 15" (381) * 14-1/2" (368) ** -4 Dimensions 10-3/4" (273) 15" (381) * 14-1/2" (368) ** *with side apron **with side splash or no side apron Page 7 of 11 7/13/2017

Standard Selections (Must select one from each category) All OmniDecks are non-cancelable and non-returnable. Submittal drawings not required for product configured to technical data options including custom length and depth selections, but available upon request. Configuration Type (Select One) NOTE: Changes to predetered dimensions require custom unit. STD.................. Standard CST.................. Custom Bowl Type (Select One) WB-TR1............ Rectangular Undermount w/ Stainless Steel Drain Cap Bowl Quantity (Select One) 1.................... One Bowl 2................. Two Bowls 3................. Three Bowls 4................ Four Bowls Deck Length (Select One) 30.00........... (Standard) 60.00.......... 60" (Standard) 90.00........... 90" (Standard) 120.00........ 120" (Standard) CST... Custom " (Length not to exceed 120") Deck Depth (Select One)* 20.5".................................................. Standard CST..........................................Custom " (must be between 20.5" and 24" in 0.5" increments) Bowl Placement (Left to Right) B1 (Bowl #1)............... 15" CST...Custom " Backsplash Type (Select One) (greater than 5" is shipped loose) BS.................Backsplash NBS............No Backsplash Front Apron Type (Select One) FA................ Front Apron Left Side Type LSS........... Left Side Splash LSA.............Left Side Apron Right Side Type RSS..........Right Side Splash RSA........... Right Side Apron NFA........... No Front Apron SEAM-L........... Side Seam NONE..... No Left Side Options SEAM-R........... Side Seam NONE.... No Right Side Options Splash Height (Select One) 3................. 3" Standard CST.... Custom (5" max) " Apron Height (Select One) 3................. 3" Standard CST...Custom (5" max) " NOTE: Aprons 5" are reinforced with gussets. Side splashes are shipped loose. B2 (Bowl #2)............... CST...Custom " B3 (Bowl #3)............... CST...Custom " B4 (Bowl #4)............... CST...Custom " *Mounting Height Deck Depth ADA/JUV... (521mm) to 24" (610mm) CSA...21" (533mm) to 24" (610mm) OBC...20-3/4" (527mm) to 24" (610mm) BCBC...22-1/4" (565mm) to 24" (610mm) QBC...23-1/2" (597mm) to 24" (610mm) Page 8 of 11 7/13/2017

Standard Selections (Must select one from each category) All OmniDecks are non-cancelable and non-returnable. Submittal drawings not required for product configured to technical data options but available upon request. Activation Type (Select One) WB1.................................... Chrome-Plated WashBar with Infrared Aerator Type (Select One) A35........................................ 0.35 gpm PCA Rubber Tip Aerator A50........................................ 0.50 gpm PCA Rubber Tip Aerator Soap Type (Select One) FSD.....................Foam Soap Dispenser - 1 Gallon Soap Container By Others LSD.................... Liquid Soap Dispenser - 1 Gallon Soap Container By Others Hand Dryer (Select One) HD1........................................... AC Motor 120V/60Hz, 20 Amp Color of Terreon Deck (Select One): Standard Colors ALP-WHT AVALANCHE BONE CHAR COBBLE DRIFT DS-WHT DUNE E-GRAY GLACIER GRAPH LANNON Alpine White Avalanche Mesa Bone Charcoal Gray Cobblestone Driftwood Designer White Sand Dune Empire Gray Glacier Graphite Lannonstone LONDON MOONSTONE O-TAUPE PEBBLE PEP-WHT POLAR SAND S-CREEK S-MIST WHT-SAND Designer Colors (available at an additional charge) ARC-CHIP...............Arctic Chip RIVER.................. Riverstone TerreonRE Colors (available at an additional charge) BIRCH-BARK............ Birch Bark DUSK....................... Dusk Water Supply Type London Gray Moonstone Organic Taupe Pebble Beach Peppered White Polar Ice Sandtrap Stone Creek Silver Mist White Sand COFFEE............. Coffee Bean MOONDUST.......... Moondust OAT........................ Oat TMA...Navigator Thermostatic Mixing Assembly w/ Stops and Hot and Cold Supply Hoses TL.............Single Tempered Line Assembly (Supply Hoses and Shut-Offs Included) Color of Terreon Bowl ALP-WHT............ Alpine White BONE.................Mesa Bone DS-WHT........... Designer White LONDON............. London Gray O-TAUPE........... Organic Taupe SAME........................... Same as Deck (Requires Tempered Water) Edge Style Type EE.......................................................... Ease Edge RO................................................ 3 8" Radius Roundover NOTE: Sidesplashes sit lower than the backsplash when RO option is selected. If wall is to be tiled after deck installation, EE option is recommended. Mounting Type (Select One) BRKT........................................ Stainless Steel Bracket(s)* NONE........................................ Customer-Supplied Mounting Access Panel Type (Select One) STAIN........................................ Swing Down Stainless Steel** NONE.................................................. No Access Panel Waste Assembly Type (Select One) S-CHROME................................... Single Chrome-Plated P-Trap S-POLY........................................ Single Polypropylene P-Trap NONE....................................................... No P-trap Seag Kit Type (180 Day Shelf Life - Each kit will accommodate a seam) AS-K................... Seam Kit NONE............... No Seam Kit * Bracket quantity is dependent on deck length. 2" to 45" = 2 brackets, 45.25" to 75" = 3 brackets, 75.25" to 105" = 4 brackets and 105.25" to 120" = 5 brackets **Recommended for easy soap maintenance This color contains large, randomly distributed chips. Page 9 of 11 7/13/2017

Structural Rough-Ins for 13-1/4" (337) C L 13-1/4" (337) Typical OmniDeck roughins for single WB-TR1 bowl are shown. Other multiplebowl rough-ins are similar. A A S S 5" (127) 3-1/2" (89) 9" (229) 13" (330) A C C S1 10-3/8" (264) 5-1/2" (140) S1 3-1/4" (83) 10-3/8" (264) C C A 3/4" (19) 21-3/4" (552) 33-1/2" (851) Deck Height 15-9/16" (394) 15-5/8" (396) Finished Floor CODE DESCRIPTION QTY. A 3/8" wall anchors with a imum pull-out force of 1,000 lbs. per local codes 2 per bracket C Install wall anchor with a imum pull-out force of 100 lbs. per local codes at locations shown 4 S #10 Wall Anchors for Soap Control Box Bracket 4 S1 #10 Wall Anchors for Soap Tank Bracket (100 lb pull out force) 4 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FIXTURE STYLE 34" No Adjustment Standard Height, ADA, TAS 31 Subtract 3" Juvenile, ADA and TAS 33-1/16" Subtract 15/16" OBC 34-1/16" Add 1/16" BCBC and QBC 33-7/8" Subtract 1/8" CSA Page 10 of 11 7/13/2017

Plumbing and Electrical Rough-Ins for Mounting for Standard, ADA and TAS height shown. Typical OmniDeck rough-ins for single WB-TR1 bowl are shown. Other multiple-bowl rough-ins are similar. C L 9" (229) 1" (25) E W 23-3/4" (603) H C 33-1/2" (851) Deck Height Tempered Supply 1" (25) 2-1/4" (57) 17-1/2" (444) 23-3/4" (603) Finished Floor CODE DESCRIPTION QTY. A 1½" NPT Drain, Stub-out 2" from wall 1 H,C ½" Noal (⁵ ₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 1 E 110V GFI protected electrical outlet (20 amp circuit) 2 Page 11 of 11 7/13/2017