HE365A,B Powered Flow-Through Humidifier

Similar documents
HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier with

HE360A,B Powered Flow-Through Humidifier

HE365A,B Powered Flow-ThroughHumidifier with

HE365A,B Powered Flow-ThroughHumidifier with JI

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

HE360 Powered Flow-Through Humidifier

HE360 Humidifier Installation Kit

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

F200E Charged-Media Air Cleaner

F150E Media Air Cleaner

HE420A Steam Power Humidifier

HE220, HE260 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit

T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

The T6140A,B Remote Bulb Temperature Controller

C554A Cadmium Sulfide Flame Detector

F25F Media Air Cleaner

H1008A,D Automatic Humidity Controls

T7079A,B Solid State Remote Temperature Controllers

Installation Instructions

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

IS Series Pressure Sensing Switches

Comfort, Energy & Health Solutions

T4398A,B Precision Electric Heating Thermostat

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

T6984F,G Electronic Floating Control Thermostats

Comfort, Energy & Health Solutions. Your family. Your home. Your comfort and peace of mind. Indoor Air Quality

CR7075 Two-Stage Lighting Controller

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Commercial/Industrial Combustion Control Level Three Announcement

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

CT500 Electronic Thermostat

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

C6097A,B Pressure Switches

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

T8011R Programmable Heat Pump Thermostat

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

F112A,C; F113A,C Portable Air Cleaners

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

T7984 A,B,C Electronic Modulating Control Thermostats

Installation Instructions Owner s Manual

UV100E Ultraviolet Air Treatment System

FLOW-THROUGH FURNACE HUMIDIFIER

L8151A Triple Aquastat Relay

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

T8602C Chronotherm IV Deluxe Programmable Thermostats

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

HEALTHY CLIMATE HUMIDIFIER

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

T8411R Electronic Heat Pump Thermostat

T834C Heating-Cooling Thermostat

T8600D Chronotherm IV Deluxe Programmable Thermostats

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

T874 Multistage Thermostat and Q674 Subbase

T8611M Deluxe Programmable Heat Pump Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

RA889A Switching Relay

Deluxe Programmable Thermostats

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

MODEL HUM HUMIDIFIERS

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

T8524 Deluxe Electronic Thermostat

C7232A,B Sensor and Controller

T6984 A,D,E Electronic Floating Control Thermostats

FLOW-THROUGH FURNACE HUMIDIFIER

Residential Steam Humidifier

F59A Console 3-Speed Electronic Air Cleaner

C7004B Flame Rod Holder

T7200D,E Series 2000 Commercial Microelectronic Thermostats

UV100A Ultraviolet System

Deluxe Programmable Heat Pump Thermostat T8611M

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Must be installed by a trained, experienced technician

G-100ES Duct Mount Humidifier

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

Must be installed by a trained, experienced technician

CT2800 Programmable Thermostat

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

M6063A Compact Rotary Mixing Valve Actuator

Heat Recovery Ventilation Systems OWNER S GUIDE

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

Instructions For A and Flame Simulators

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

CT2700 An Electronic Round Programmable Thermostat

G-100ES Duct Mount Humidifier

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

MagicStat CT3300 Programmable Thermostat

Duct Mount Atomizing Humidifier

Owner s Manual For Models 400, 500, 600 & 700

Transcription:

HE65A,B Powered Flow-Through Humidifier whole-house air quality system FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. Bold new look with blue and white styling. Capable of humidifying the largest area up to 400 sq ft (90 sq m) of any Honeywell flow-through humidifier. Includes the PerfectFlo water distribution tray for optimal efficiency and water usage. Narrower footprint than popular compatible model while maintaining a common humidifier pad and comparable humidification performance. Interior components designed for quick maintenance and service. APPLICATION The Enviacaire Elite HE65A,B Powered Flow-through Humidifiers use the warm air furnace blower to provide humidification for the whole house. HE65A Humidifier includes a convertible humidity control that mounts on the wall or duct for more flexibility. HE65B Humidifier includes the Automatic Humidity Control with HumidCalc+ that automatically adjusts humidity level and eliminates moisture build-up. Continuous flushing reduces the frequency of maintenance in a hard water installation. AIRWATCH Indicator can be installed to remind homeowner to change humidifier pad. Five-year warranty. U.S. Registered Trademark Copyright 000 Honeywell All Rights Reserved 68-04

SPECIFICATIONS The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. TRADELINE Models Available: HE65A: Includes humidifier, antimicrobial humidifier pad, mounting template, self-piercing saddle valve and H8908B Convertible Humidity Control. HE65B: Includes humidifier, antimicrobial humidifier pad, mounting template, self-piercing saddle valve and H008A Automatic Humidity Control. Capacity: At 0 F (49 C) plenum temperature and 0.0 static pressure drop across supply and return: 8 gallons per day (gpd), 68 liters per day (lpd). Humidified Area: House Air Changes Area (Up To) Description Per Hour Sq ft Sq m Loose Two,900 75 Average One,700 48 Tight One-half 4,00 86 Electrical Ratings: 0 Vac, 60 Hz, 0.7A. Humidifier Pad Dimensions (height x width x depth): in. x 0 in. x -/ in. (0 mm x 54 mm x 8 mm). Plenum Opening Dimensions (height x width): 4-/6 in. x -/ in. (57 mm x 4 mm). Drain Connection: / in. ( mm) I.D. plastic hose connected directly to drain fitting on unit. Dimensions: Refer to Fig.. 0-/4 (60) 4 (56) Fig.. HE65A,B dimensions in in. (mm). Approvals: Underwriters Laboratories Inc.: Listing Pending. Canadian Underwriters laboratories Inc.: Listing Pending. Standards: Air Conditioning and Refrigeration Institute Tested: Standard 60. Accessories: C7089H Outdoor Temperature Sensor. H8908B Convertible Humidity Control. H008A Automatic Humidity Control. HC6E Humidifier Antimicrobial Pad. PC8900 Control. S688A Sail Switch. Current Sensing Relay part no. 00754-00. 5-/4 (87) M485 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Home and Building Control Sales Office (check white pages of your phone directory).. Home and Building Control Customer Relations Honeywell, 985 Douglas Drive North, MN0-46 Golden Valley, Minnesota 554-486 -800-468-50 In Canada Honeywell Limited/Honeywell Limitée, 5 Dynamic Drive, Scarbouorgh, Ontario MV 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-04

INSTALLATION When Installing this Product.... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. CAUTION Personal Injury or Equipment Hazard. Improper drilling can cause equipment damage or personal injury. Do not cut or drill into any air conditioning or electrical accessory. CAUTION Property or Equipment Hazard. Can cause property or equipment damage. Locate the humidifier where the ambient temperature is between F (0 C) and 60 F (7 C). Do not install where freezing temperatures could occur. Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 5 psi. Location and Mounting Mount the humidifier at least in. (76 mm) above the furnace jacket to allow adequate space for the drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. Do not install on a furnace jacket. RETURN RETURN Fig.. Typical humidifier installation locations. Fig.. HE65 Humidifier location in relation to air conditioning cooling coils. FEED TUBE NOZZLE WATER DISTRIBUTION TRAY PAD ASSEMBLY HORIZONTAL LOWBOY RETURN DOWN FLO M8A RETURN HIGHBOY M808A. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. and. Be sure the template is level before marking to assure optimal product performance.. Tape the template in position and trace around the template.. Remove the template and carefully cut the rectangular opening. 4. Loosen the thumbscrew on the bottom of the humidifier and remove the cover. 5. Remove the humidifier pad assembly by grasping the top of the tray and pulling the assembly out of the housing. See Fig. 4. 6. Position the securing clips as shown in Fig. 5. Do not completely seat them. THUMB SCREW COVER ASSEMBLY Fig. 4. Humidifier components. HOUSING M467 68-04

CLIP CLIP. Connect only the two yellow wires to the humidity control (red wire connections are not used for mechanical humidity control). See the typical wiring diagrams in Fig. 6 through 8. Fig. 5. Position securing clips. M8 7. Position the humidifier housing in the hole (be sure it is level), so the locking tabs are in place on the upper and lower sheet metal edges of the hole. 8. Push in the securing clips until completely seated. 9. Drill holes and install the three sheet metal screws at the top of the humidifier housing. Secure the housing with the three remaining screws at the bottom of the housing. 0. Reinstall the humidifier pad assembly in the humidifier housing. For additional mounting and wiring information, refer to the humidity control installation instructions. For H008 Automatic Humidity Control Wiring Connections: Current sensing relay or sail switch is not needed with the Automatic Humidity Control.. Connect the two red and two yellow wires to the electronic humidity control as shown in Fig. 9. For additional mounting and wiring information, refer to the humidity control installation instructions. For proper operation, be sure the mark on the end of the humidifier pad is facing up. Check that the water feed tube is placed in the guide slots of the humidifier housing.. Hook the top of the cover to the housing and secure with the thumbscrew located at the bottom of the cover. MECHANICAL HUMIDISTAT YELLOW WIRES 0 VAC TO BLOWER MOTOR IGNITION BOX WIRING WARNING Serious Personal Injury or Equipment Hazard. Moving parts can cause electrical shock and injury. Disconnect power supply before installation or servicing. This device contains a moving fan blade; do not operate the humidifier without the cover securely attached. All wiring must comply with applicable local codes, ordinances and regulations. For H8908B Convertible Humidity Control Wiring Connections: Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed. If not using a current sensing relay or sail switch, the 0V humidifier plug must be energized during blower motor cycles for proper operation.. Wire the current sensing relay or sail switch. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 4V WIRING. MECHANICAL HUMIDISTAT CURRENT SENSING RELAY BLOWER MOTOR C LO HI YELLOW WIRES M686 Fig. 6. Typical wiring diagram for humidifier using fan control to cycle blower motor fan and humidifier simultaneously. 0 VAC POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 4V WIRING. M684 Fig. 7. Typical wiring diagram of current sensing relay with humidifier. 68-04 4

MECHANICAL HUMIDISTAT 0 VAC SAIL SWITCH YELLOW WIRES POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 4V WIRING. M685 Fig. 8. Typical wiring diagram of sail switch with humidifier. ROOM THERMOSTAT DEHUM OUT G W R DEHUM OUT 0 VAC HUM HUM HOT COM 4VAC BLACK AUTOMATIC HUMIDITY CONTROL BLACK CONNECTOR SOLENOID POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 4V WIRING. G CG CW W FROST FACTOR SETPOINT DIAL FAN RELAY HEAT ONLY APPLICATIOIN SHOWN. SIMILAR WIRING REQUIRED IN HEAT AND COOL SYSTEM WITH ONE OR TWO TRANSFORMERS. HEAT RELAY FURNACE TRANSFORMER L (HOT) L M80B Fig. 9. Typical wiring diagram for humidifier using H008 Automatic Humidity Control. For PC8900/W8900 Wiring Connections: Connect only the two yellow wires to the W8900 (red wire connections are not used). See the typical wiring diagram in Fig. 0. PC8900 W8900B OPTIONAL OUTDOOR AIR SENSOR Plumbing Saddle Valve Hot or cold water, either hard or softened, can be used in the humidifier. 4. Use the self-piercing saddle valve included to tap into the water supply line at an appropriate location. CAUTION Equipment Hazard. Improper installation can cause equipment damage. Do not use any line connected to an air conditioner. 0 VAC HE65 RED RED YELLOW YELLOW POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. OPTIMAL CONTROL ACHIEVED WHEN USING OUTDOOR AIR SENSOR. RED WIRES ARE NOT USED IN THIS APPLICATION. M486 Fig. 0. Typical wiring diagram for humidifier using PC8900/W8900. 5 68-04

The saddle valve is not designed to regulate water flow; the valve is either open or closed. Be sure to install the saddle valve handle pointing toward the ceiling to prevent debris from clogging the solenoid in-line filter. NOTE: Lightly clean the copper tubing ends with fine sandpaper before making any connections.. Use /4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. a. Place the brass compression nut over the copper tubing. b. Slide the brass ferrule over the tubing. NOTE: Do not over-tighten the compression nut. Moderate tightness prevents leaking. c. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut..connect a / in. hose to the humidifier drain fitting and run it to a suitable drain. NOTE: Slope the hose downward for correct drainage. CHECKING INSTALLATION. Open the saddle valve. NOTE: The furnace blower must be operating for the humidifier to work.. Set the thermostat setpoint 0 F ( C) above the room temperature.. Set the humidity control to a high humidity setting, or place the humidity control in the test position. 4. Observe the water running out of the drain line to be sure the humidifier is working correctly. 5. Check for leaks. 6. Reset the thermostat and humidity control to comfortable settings. OPERATING The Enviracaire Elite HE65A Humidifier is controlled by the H8908B Convertible Humidity Control. The convertible humidity control is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/ outdoor temperature setting scale on the humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level to reduce the moisture condensation on your windows. The table below can also be used to adjust the humidity control to the recommended setting. NOTE: As outside temperature drops, the recommended humidity control setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows. If this condition persists for more than a few hours, set the humidistat to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate the house to remove the moisture. The Enviracaire Elite HE65B Humidifier is controlled by the Honeywell H008 Automatic Humidity Control with HumidCalc+. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidCalc+_software inside the automatic humidity control is designed to measure or infer the outdoor temperature and automatically adjust the humidity based on the frost factor. The frost factor is set by the homeowner and allows for variances in furnace size, window type and insulation. The Automatic Humidity Control with HumidCalc+ requires initial adjustment when first installing the HE65B. Set the frost factor dial to 5 and use Table to adjust the frost factor, one setting at a time, increasing the dial setting for more humidity, or reducing the setting if moisture starts to build up on the inside of your windows. Allow two days between adjustments to determine if further adjustment is necessary. Once the frost factor has been set, no further adjustment is needed. OPERATION The HE65A,B Humidifiers use the principle that vapor (evaporated water) is created when warm dry air blows over a water-soaked area. As the vapor circulates, the relative humidity rises. The humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that disburses water over a humidifier pad. The warm dry air from the furnace passes over the humidifier pad, collects moisture, and circulates it through the house. Since humidified air feels warmer and more comfortable, the homeowner may decide to lower the thermostat setpoint, thus saving money on heating bills. The end result is that the humidifier provides a more comfortable environment that is also energy efficient. 68-04 6

Table. Recommended Humidity Control Settings. Outside Temperature Recommended Setting Outside Temperature Recommended Setting -0 F (-9 C) 5 +0 F (- C) 0-0 F (- C) 0 +0 F (-7 C) 5 0 F (-8 C) 5 +0 F (-7 C) 40 Table. Recommended Frost Factor Adjustment. Humidity Level Insufficient humidity Condensation on windows Recommended Setting Increase the frost factor dial be one setting Reduce the frost factor dial by one setting. MAINTENANCE A regular maintenance program prolongs the life of the humidifier and provides a more comfortable environment. Frequency of cleanings depends on water conditions. Either hard or soft water can be used in the humidifier, but hard water mineral deposits are more difficult to clean then soft water deposits. Use the following procedure to clean the humidifier. CAUTION Personal Injury or Equipment Hazard. Power Supply can cause electrical shock or equipment damage. Disconnect power supply before performing humidifier maintenance. Never oil any part of the humidifier. Every To Months (Depending on Water Quality). Disconnect the power and turn off the humidifier water supply.. Remove the humidifier cover. See Fig.. FEED TUBE NOZZLE WATER DISTRIBUTION TRAY PAD ASSEMBLY. Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward you. 4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame. 5. Gently pinch the water nozzle catches inward until the water nozzle can be lifted off the tray. 6. Slide the humidifier pad out of the frame. 7. Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain hole has nothing blocking it. 8. Check the humidifier pad and if excessive mineral deposits are present, replace with a new HC6E Antimicrobial Pad. 9. Disconnect the drain hose from the drain fitting on the bottom of the humidifier housing. 0. Clean the drain fitting, if necessary.. Bend the drain hose to loosen any mineral deposits.. Flush the drain hose with pressurized water (a running tap) to clean the hose.. Reattach the drain hose to the drain fitting. 4. Slide the humidifier pad back into the frame. I To maintain the antimicrobial properties of the humidifier, use only a Honeywell HC6E Antimicrobial Pad. Be sure the marked side of the antimicrobial humidifier pad is facing up for proper performance. 5. Reattach the tray to the frame. 6. Snap the water nozzle back on the tray. 7. Place the antimicrobial humidifier pad assembly in the humidifier housing and press until the assembly is seated. 8. Be sure the water feed tube is placed in the guide slots of the humidifier housing. 9. Replace the humidifier cover. 0. Verify the humidifier operation by following the steps in the Checkout Procedure section. THUMB SCREW COVER ASSEMBLY HOUSING M467 End of Humidification Season The humidifier needs to be cleaned and shut off at the end of the heating season. Follow steps through 9 from the Every To Months section. Be sure the humidifier power is off. Fig.. Location of humidifier parts. 7 68-04

Beginning of Humidification Season Refer to the Checkout Procedure section for complete humidifier startup instructions. Vacation Turn off the humidifier water supply and the humidity control while on vacation. When you return, turn on the humidifier water supply and reset the humidity control to restart the humidifier. CHECKOUT PROCEDURE After winter startup or servicing, use the following steps to check the humidifier operation.. Turn on the humidifier power and water supply.. Turn the humidity control to its highest setting and set the thermostat to 0 F ( C) above the room temperature.. Observe that water is flowing out of the drain hose. NOTE: The furnace blower must be operating for the humidifier to work. TROUBLESHOOTING Refer to Table for troubleshooting procedures. 4. Reset the thermostat and humidity control to a comfortable setting for automatic operation. Table. Troubleshooting Procedures. Problem What To Look For What To Do Low humidity Furnace blower not operating. Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier). Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. High humidity Condensation on walls. Turn off humidity control and water until condensation is completely evaporated. Heavy condensation on windows. Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 68-04 8

REPLACEMENT PARTS Refer to Fig. and Table 4 when ordering replacement parts. Table 4. List of HE65 Replacement Parts. Feed Tube Nozzle 000408-00 Water Distribution Tray 0060-00 Solenoid Valve Assembly (Includes water feed tube) 00876-00 4 Antimicrobial Humidifier Pad HC6E004 5 PWB Assembly 00676-00 6 Frame 006-00 7 Base/Insert Assembly 00660-00 8 Fan Blade 00049-00 9 Motor Mount 00670-00 0 Fan Shroud 00664-00 Fan Motor 00046-00 Bag Assembly, Saddle Valve 0066-00 Convertible Humidity Control H8908B00 4 Automatic Humidity Control H008A008 5 Relay 00754-00 6 Cover/Screw Assembly 0066-00 7 Power Cord 0004-00 8 Drain Fitting 0065-00 Not shown Hardware Kit for Solenoid Assembly (same as Solenoid Valve Assembly without the solenoid valve) 0075-00 9 68-04

7 4 6 4 5 8 0 40 0 0 50 OFF ON 60 0 8 9 7 6 5 THE HE65A INCLUDES THE H8908B CONVERTIBLE HUMIDITY CONTROL. THE HE65B INCLUDES THE H008A AUTOMATIC HUMIDITY CONTROL. M487 68-04 0

68-04

IMPROVE YOUR INDOOR AIR WITH A COMPLETE whole-house air quality system ULTRAVIOLET AIR TREATMENT SYSTEM ZAP airborne germs. Kill most germs before they recycle through your home. Prevent mold spores from growing on your system cooling coils. F00E ELECTRONIC AIR CLEANER TRAP airborne particles. Up to 99% efficient at capturing airborne particles. Effectively REDUCES fungi, bacteria, mold antigen, cat antigen and ragweed pollen antigen that pass through system. ENVIRACAIRE ELITE S Moisturize parched air. Help maintain proper humidity to minimize adverse health effects. Features special antimicrobial agent to prevent surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. Honeywell offers one of the broadest families of home solutions in the industry - ranging from thermostats, zoning, ventilation, air cleaning, humidification to internet-enabled home control and wireless WebPAD devices for web surfing and more!! Check out our offerings on-line at www.honeywell.com/yourhome/... only from Honeywell. M4757 Home and Building Control Honeywell 985 Douglas Drive North Golden Valley, MN 554 Home and Building Control Honeywell Limited-Honeywell Limitée 5 Dynamic Drive Scarborough, Ontario MV 4Z9 Printed in U.S.A. on recycled 68-04 G.H. -00 paper containing at least 0% post-consumer paper fibers. www.honeywell.com/yourhome/