DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Similar documents
DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Pet Immune SAW PIR Motion Sensor

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

ShockLink. Important Product Information.

SZ-PIR04N ZigBee Motion Detector Installation Guide

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Extended Range DUAL TEC Motion Sensor

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Immunity. P/N: ver.b

Wireless Outdoor Air Reset Adaptor PN:

AVS Audio Verification System

NetworX NX-548E Receiver Installation Instructions

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Wireless High Bay Sensor (WHS100) Installation Instructions

1126 Series Ceiling Mount PIR Motion Detector

Installation Instructions

Wireless ShatterPro Acoustic Sensor Installation Instructions

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Model 17A00 Expansion Enclosure

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

180 Degree Ceiling Mounted Occupancy Sensors

BE1310 Visit Smart hub

1100X Wireless Receivers

GARAGE DOOR OPENER KIT

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

1100D Wireless Receiver

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Description. Optex Incorporated

Installation Instructions

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Door/Window Sensor Installation Instructions

English. Italiano. Português. Françias. Español

Wi-Fi DOOR/WINDOW SENSOR

Optima ZigBee Thermostat

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Smart Hub THERMOSTAT. Installation Manual

FTP-1000 Touchpad/Display Installation Manual

ADT. Pulse 2017ADT LLC

General Description. Industrial LuNAR DT AM Grade 3 Features

Wireless External Alarm

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Disclaimer. Trademarks. Copyright. Warranty

Wireless Weather Station

Case com Leitor 2D Honeywell Captuvo SL22

S541.RF 4G Product Guide

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Rev D 3/20/17

PET IMMUNE PIR MOTION DETECTOR

SP-1000X. Panic Device Power Controller Installation Guide. Rev

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

1125 PIR Motion Detector

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Badge Reader BR Installation Guidelines. Product Summary

TEC2100 Series Networked Thermostats

PRODUCT DIAGRAM PACKAGE CONTENTS

Concord 5 TouchScreen Installation Sheet

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

PRODUCT DIAGRAM PACKAGE CONTENTS

Automatic Dimming Mirror with HomeLink

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Motion Detectors for Larger Rooms and Areas

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

STANDARD FEATURES SPECIFICATIONS

Independent Zone Control (I.Z.C.)

Installer Guide smart connect

Performance Thermal Binder

Smart THERMOSTAT. Installation Manual

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Atomic Digital Office Clock

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Nest x Yale Lock Programming/Troubleshooting Guide

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

IPGSM-DPC Commercial Fire Communicator

Installer Guide smart connect

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Advanced DIGITAL Wired PIR Motion Detector

INSTALLATION GUIDE XTLN-WIFI PANEL

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Draft - develop and review

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

IDP-Zone-6 Six Zone Interface Module

Transcription:

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor Wiring Examples Walk Test the Sensor Detection Patterns Remote LED Enable Relay Operation Mask Condition Troubleshooting Sensor Specifications Accessories Approval Listings Mounting location guidelines: The optimal range is obtained at a mounting height of 7 6 (2.3m). Allow a clear line-of-sight to all areas to protect. Avoid mounting anything within 12 (30cm) in front of the sensor*. Do not directly face windows. Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. Not for use in applications with pets. 1. Turn the arrow to point to the Unlock symbol. 2. Press firmly on housing latch. 3. Gently separate the front and rear housing.

[A] = Wall mounting holes. [B] = Corner mounting holes. The rear tamper plate MUST be mounted to a stud, solid wood, or with a robust wall anchor. See wiring details and examples on page 3. - 2 -

WIRING DETAILS FOR INTERNAL EOL RESISTORS - Observe proper polarity. - Connect the sensor to the panel (see wiring diagrams below). - For Vista panels, set the Internal 2K EOL switch (factory default). Notes: - Consult the Control Panel manual to determine proper EOL selection. - The EOL setting must only have one switch. - If not using the internal EOL resistors, set all switches to OFF. Wiring Examples To connect all three outputs (sensor alarm, tamper and trouble/anti-mask) to one zone input: All alarm, tamper and trouble/anti-mask events are alarms when the system is armed or fault when disarmed. To connect the sensor alarm output to one zone input and the tamper and trouble/antimask outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble/anti-mask are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble/anti-mask conditions. To connect the sensor alarm, tamper and trouble/anti-mask outputs to three separate zone inputs: The alarm, tamper and trouble/antimask are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask conditions. - 3 -

LED Red Yellow Power Up Slow Blink OFF Walk Test Normal Trouble Anti-Mask Alarm Microwave Alarm Microwave Fast Blink OFF OFF Fast Blink Green OFF PIR PIR OFF OFF 1. Apply power to the sensor. Initialization is complete when the LED stops flashing slowly (about 30 seconds). 2. Turn the microwave sensitivity counterclockwise to reduce the microwave range (minimum = 16.4 / 5m) and close the sensor. 3. Walk through the detection area and observe the LED. 4. Adjust the microwave range as necessary to meet installation requirements. Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature: Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting. Flashlight Feature: 1. Use a flashlight with a bright light beam, and stand within 4 (1.2 m) of the sensor. 2. Swing the light beam past the sensor IR window 3-5 times, holding the beam on the window for 0.5 second each pass. The flashlight feature is only available for the first 24 hours after the first power up. Zones A 2 Look-down B 12 Lower C 10 Intermediate D 36 Long - 4 -

REMOTE LED ENABLE (LED INPUT)* The LED input terminal allows the LED to be remotely enabled. To use this feature, the LED DIP switch (switch 2) must be OFF, allowing the LED to operate based on the voltage level connected to the LED Input (see Wiring Details). Switch 2 LED Input LED Operation OFF High ( +12 V) Enabled OFF Low (0 V) Disabled Low (0 V) or High (+12 V) Enabled RELAY OPERATI SENSOR STATUS Normal Intrusion Trouble 1 Mask 2 Alarm Relay Closed Open Closed Open Trouble Relay 3 Closed Closed Open Open 1 For information on Trouble conditions, see the Troubleshooting section. 2 In a Mask condition, the Alarm and Trouble relays will activate simultaneously, and remain open until the condition has been cleared. 3 In a Trouble condition, the Trouble relay will latch open until the Trouble condition has been cleared. MASK CDITI Normal Anti-Mask Condition The sensor uses Active Infrared (AIR) technology to detect masking. The sensor signals a mask condition when a variety of materials and reflective objects are placed within 2 inches (50mm) in front of the sensor. To avoid false mask alarms, follow the mounting guidelines shown in Step 1. Clearing an Anti-Mask Condition When most masking materials or objects are removed, the anti-mask condition will be cleared after several seconds. When the cause of the anti-mask condition is any type of spray or paint coating applied to the window, the window must be replaced before the anti-mask condition can be cleared. After replacing the window, perform a walk test on the sensor. TROUBLESHOOTING TROUBLE* NORMAL Mask 1 Low Self-Test Voltage 2 Failure 3 Alarm Relay Closed Open Closed Closed Trouble Relay Closed Open Open Open Red LED Off Off Off Flashing Yellow LED Off Flashing Off Off *TROUBLE CDITIS: 1 Mask condition: Sensor IR window is blocked or masked. 2 Low Voltage: The sensor is disabled. [Note: If voltage drops below 7.9V, the Trouble relay will open.] 3 Self-Test Failure conditions: Microwave supervision failure: The sensor is operating in PIR mode only. PIR self-test failure: The sensor is disabled. Temperature compensation failure: The temperature compensation is disabled. Depending on the Trouble condition, take the following corrective actions: Verify the sensor is not blocked or masked. Verify the power supply is sufficient (at least 9V at the sensor). Cycle power to the sensor. Walk test the sensor. If the Trouble condition does not clear, replace the sensor. SPECIFICATIS Range: 53 x 72 / 16 m x 22 m Wall Mounting Height: 6 9-8 9 (2.1 m - 2.7 m); Optimal 7 6 (2.3 m) Power: 9.0-15 VDC (UL: 9.5-15 VDC); 15 ma typical, 18 ma maximum; AC Ripple: 3 V peak-to-peak at nominal 12 VDC Alarm Relay: Energized Form A; 30 ma, 25 VDC, 22 Ohms resistance maximum. Alarm Relay Duration: 3 seconds Trouble Relay: Energized Form B; (NC) 30 ma, 25 VDC; 22 Ohms resistance maximum Tampers: Cover & Wall; (NC with cover installed) Form A; 30 ma, 25 VDC Microwave Frequencies: 10.525 GHz RFI Immunity: 20V/m 10-1000MHz, 15V/m 1000-2700MHz PIR White Light Immunity: 6,500 Lux typical Fluorescent light filter: 50 Hz / 60 Hz. Operating Temperature: 14 to 131 F / -10 to 55 C Relative Humidity: 5 to 93% (UL tested at 93%); non-condensing Temperature Compensation: Advanced Dual Slope Dimensions: 4.57 H x 2.76 W x 1.69 D / 11.6 cm H x 7.0 cm W x 4.3 cm D Weight: 5 oz / 142 g (net weight) ACCESSORIES SMB-10* Swivel Mount Bracket (P/N 0-000-110-01) SMB-10C* Swivel Mount Ceiling Bracket (P/N 0-000-111-01) SMB-10T* Swivel Mount Bracket w/tamper (P/N 0-000-155-01) DT8-G3 IR Window Kit Replacement IR Window Kit (P/N DT8G3IRW5PK) 5 Pack Cable* (P/N 1103) General purpose, Solid 22 AWG, 4 conductor Cable* (P/N 1104) General purpose, Stranded 22 AWG, 4 conductor Cable* (P/N 1106) General purpose, Solid 22 AWG, 6 conductor Cable* (P/N 1107) General purpose, Stranded 22 AWG, 6 conductor * Not evaluated by UL. APPROVAL LISTINGS FCC part 15, Class B verified IC ICES-003, Class B verified UL 639 ULC S306-03 SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. Product must be tested at least once each year. All wiring must be in accordance with: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (where applicable); UL681, Standard for Installation and Classification of Burglar and Holdup Alarm Systems; ULC-S302, Standard for Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC-S310, Standard for Installation and Classification of Residential Burglar Alarm Systems; local codes and the authorities having jurisdiction. The products are intended to be powered by a power-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC-S318 power-limited power supply that provides 4 hours of standby power. The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anchor. UL Notes: All interconnecting devices must be UL Listed. The antimask feature has not been evaluated by UL. - 5 -

FEDERAL COMMUNICATIS COMMISSI STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient the receiving antenna until interference is reduced or eliminated. Move the radio or television receiver away from the receiver/control. Move the antenna leads away from any wire runs to the receiver/control. Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. Consult the dealer or an experienced radio/tv technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/mywebtech/ For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security P/N 800-15666 03/14 Rev B