Potential Applications

Similar documents
HIH-4602-L Series Humidity Sensors

HIH-4000 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4030/31 Series Humidity Sensors

HIH-4010/4020/4021 Series Humidity Sensors


HIH-5030/5031 Series Low Voltage Humidity Sensors

HIH-4602 A & C Series.

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

FSS-SMT Series. Low Profile Force Sensor

HOA6480 Series Barcode Sensor Infrared Products

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

V-Basic Standard V15 Series

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

General Purpose Industrial VRS Magnetic Speed Sensors

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

High Temperature Industrial VRS Magnetic Speed Sensors

FEATURES AND BENEFITS

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Linear Current Sensors

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

WARNING MISUSE OF DOCUMENTATION

MICRO SWITCH GLL Series

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

MICRO SWITCH V15W Series Watertight Miniature Switches

Airflow Sensors Line Guide

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

MICRO SWITCH GSX Series

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

Airflow Sensors Line Guide

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Sensors in Ventilators

Installation Instructions for the 600 Series Optical Encoders

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

LCZ Series Hall-effect Zero Speed Sensors

Wireless Panel-Mount Monitor

Installation Instructions for the

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Installation Instructions for the

Interactive Catalog Replaces Catalog Pages

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Force Sensors Line Guide

MICRO SWITCH NT Series

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

MICRO SWITCH NT Series

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Intrinsically Safe Transmitters, Option Code 2n

MICRO SWITCH BX/BX2 Series

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Quadrature Speed and Direction Sensors

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

MICRO SWITCH BAF/DTF Series

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

TruStability Board Mount Pressure Sensors

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

AMR 4-Pin Quadrature Sensor Integrated Circuit

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Selecting Honeywell Board Mount Pressure Sensors

MICRO SWITCH E6/V6 Series

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Interactive Catalog Replaces Catalog Pages

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Transcription:

HIH-4602-L HIH-4602 Series monolithic IC humidity sensor with integral precision RTD in TO-39 Features Linear voltage output vs %RH Laser-trimmed interchangeability Chemically resistant Enhanced accuracy, fast response Stable, low drift performance Built-in static protection Potential Applications Refrigeration equipment Drying Meteorology Battery-powered systems OEM assemblies Description The HIH-4602-L Relative Humidity (RH) sensors deliver instrumentation-quality RH sensing performance in a rugged, low cost, slotted TO-39 housing that provides a quick response while still maintaining the robustness of an enclosed component. The lasertrimmed, thermoset polymer capacitive sensing elements have on-chip integrated signal conditioning. The HIH-4602-L-CP includes calibration and data printout. Product Specifications Package Type TO-39 can Operating Temperature Range -40 ºC to 85 ºC [-40 ºF to 185 ºF] Operating Humidity Range 0% RH to 100% RH Interchangeability 0% RH to 59% RH ±5%, 60% RH to 100% RH ±8% Accuracy (BFSL) ±3.5% Hysteresis Response Time Repeatability Settling Time Max. Supply Voltage 3% RH 5 s 1/e in slow moving air ±0.5% RH 70 ms max. 5.8 Vdc Max. Supply Current 500 µa Stability at 50% RH Output Signal Covered Device Moisture/Dust Filter Combined Humidity and Temperature Sensor ±1.2% RH Analog voltage Yes No No Calibration and Data Printout No

HIH-4602-A/C Series Humidity Sensors DESCRIPTION HIH-4602-A/C Series Relative Humidity (RH) sensors combine both relative humidity and temperature sensing in a TO-5 housing with a hydrophobic sintered stainless steel filter. The laser-trimmed, thermoset polymer capacitive sensing elements have on-chip integrated signal conditioning. The HIH-4602-A contains an integral thermistor, while the HIH- 4602-C contains an integral precision RTD. Factory calibration data supplied with each sensor allows individually matched downstream electronics and ±3.5 %RH total accuracy. The temperature sensor is thermally connected with the RH sensor making the HIH-4602-A/C often ideal for measuring dew point and other absolute moisture terms. FEATURES Near linear voltage output vs %RH Laser-trimmed interchangeability Enhanced accuracy, fast response Chemically resistant Stable, low drift performance Built-in static protection Often ideal for dew point and absolute moisture measurements TO-5 housing POTENTIAL APPLICATIONS Refrigeration Drying Meteorology Battery-powered systems OEM (Original Equipment Manufacturer) assemblies

HIH-4602-A/C Series TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note Interchangeability (first order curve) 0% RH to 59% RH -5 5 % RH 60% RH to 100% RH -8 8 % RH Accuracy (best fit straight line) -3.5 +3.5 % RH 1 Hysterisis 3 % RH Repeatability ±0.5 % RH Settling time 70 ms Response time (1/e in slow moving air) 50 s Stability (at 50% RH in one year) ±1.2 % RH Voltage supply 4 5.8 Vdc Current supply 200 500 µa Output voltage temp. coefficient at 50% RH, 5 V -4 mv/ºc Voltage output (1st order curve fit) V OUT =(V SUPPLY )(0.0062(sensor RH) + 0.16), typical at 25 ºC Temperature compensation True RH = (sensor RH)/(1.0546-0.00216T), T in ºC Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF] Operating humidity 0 See Figure 1. 100 % RH 2 Storage temperature -50[-58] 125[257] ºC[ºF] Storage humidity See Figure 2. % RH 2 Specific Notes: 1. Device is calibrated at 5 Vdc and 25 ºC. 2. Non-condensing environment. General Notes: Sensor is ratiometric to supply voltage. Extended exposure to >90% RH causes a reversible shift of 3% RH. Sensor is light sensitive. For best performance, shield sensor from bright light. FACTORY CALIBRATION DATA HIH-4602 Sensors are supplied with a calibration and data printout. See Table 2. TABLE 2. EXAMPLE DATA PRINTOUT Model HIH-4602-C Channel 92 Wafer 030996M MRP 337313 Calculated values at 5 V V OUT at 0% RH V OUT at 75.3% RH 0.826 V 3.198 V Linear output for 3.5% RH accuracy at 25 C Zero offset Slope RH 0.826 V 31.483 mv/%rh (V OUT - zero offset)/slope (V OUT - 0.826)/0.0315 Ratiometric response for 0% RH to 100% RH V OUT V SUPPLY (0.1652 to 0.7952) TABLE 3. HIH-4602-A NTC THERMISTOR TEMPERATURE SPECIFICTIONS Rb = 100 kohm ±5% at 25 ºC Beta = 4250, 25 ºC to 85 ºC 1/T = a + b(ln R) + c(ln R) ^ 3, T in degrees K Low Mid High a = 0.000828083 b = 0.000208691 c = 8.0812E-08 Temp. ºC 0 50 100 Resistance 351000 33590 5569 TABLE 4. HIH-4602-C RTD TEMPERATURE SENSOR SPECIFICATIONS Thin film platinum RTD Class 2B (Ro: ±0.25%) DIN EN 60571 (PER IEC 751) TCR = 3750 ppm/ºc 1000 Ohm at 0 ºC [32 ºF] 2 www.honeywell.com/sensing

Humidity Sensors FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.) FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment.) Honeywell Sensing and Control 3

HIH-4602-A/C Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 3 Output Voltage (Vdc) 2.5 2 Sensor Response Sensor Response Best Linear Fit 1.5 1 0.5 0 20 40 60 80 100 Relative Humidity (%RH) FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 Output Voltage (Vdc) 3 2.5 2 1.5 0 C 70 C 1 0.5 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%) 4 www.honeywell.com/sensing

Humidity Sensors FIGURE 5. HIH-4602-A/C 1MOUNTING DIMENSIONS (For reference only. mm/[in]) 1. Case ground 2. Vdc out 3. (-) Power or ground 4. (+) Vdc supply 5., 6. HIH-4602-A thermistor for temperature compensation 5., 6. HIH-4602-C RTD for temperature compensation FIGURE 6. RH SENSOR CONSTRUCTION Sensor construction consists of a planar capacitor with a second polymer layer to protect against dirt, dust, oils and other hazards. Honeywell Sensing and Control 5

HIH-4602-A/C Series FIGURE 7. TYPICAL APPLICATION CIRCUIT ORDER GUIDE Catalog Listing HIH-4602-A HIH-4602-C Description Monolithic IC humidity sensor with integral thermistor in TO-5 can Monolithic IC humidity sensor with integral precision RTD in TO-5 can FURTHER HUMIDITY SENSOR INFORMATION See the following associated literature at www.honeywell.com/sensing: Product installation instructions Application sheets: Humidity Sensor Performance Characteristics Humidity Sensor Theory and Behavior Humidity Sensor Moisture and Psychrometrics Thermoset Polymer-based Capacitive Sensors 6 www.honeywell.com/sensing

Humidity Sensors THIS PAGE INTENTIONALLY LEFT BLANK.. Honeywell Sensing and Control 7

WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 009022-1-EN IL50 GLO Printed in USA January 2007 2007 Honeywell International Inc. All rights reserved.