Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Similar documents
Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

62DA,DB,DC,DD,DE,DF07-38

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

RHX. Product Specifications

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

PERFORMANCE, INNOVATION, RELIABILITY

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

RGE 13 A T - 1 A

DCG Commercial. Submittal Data Form

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

48KC Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

Product Data. Fig. 1 - Unit 50VR -A

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Advanced Product Data

13 GEP A L P - 1 A

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

582J GAS HEAT/ELECTRIC COOLING SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS. Product Data C (Shown with optional Louvered Hail Guard)

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

GUIDE SPECIFICATIONS 48LC**14-26

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

PERFORMANCE, INNOVATION, RELIABILITY

Product Data. 48LC Ultra High Efficiency Gas Heat/Electric Cooling Packaged Rooftop 3to5NominalTons. Carrier s Most Efficient Commercial Rooftop Ever!

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Input Cap. (Btuh) Stage 2

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

THE RIGHT SPEC. RIGHT NOW.

RHEEM PACKAGE GAS/ELECTRIC

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Submittal Summary Page

GUIDE SPECIFICATIONS - 48LC*004-06

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Ruud Commercial Achiever Series Package Gas Electric Unit

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Submittal Data Performance Data Electrical Data

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Input Cap. (Btuh) Stage 2

GREEN REFRIGERANT R-410A

WALL-MOUNT HEAT PUMPS - (60HZ)

Product Data RELIABILITY FEATURES

TECHNICAL SPECIFICATIONS

Installation Instructions

4YCC3048A3096A /3/ /

TECHNICAL SPECIFICATIONS

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Product Data. Fig. 1 - Unit 50EZ -A

PAR5. Product Specifications

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Product Data. Fig. 1 - Unit 50VG -A

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

High Heat COP. High/Low Stage

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

INSTALLATION INSTRUCTIONS R -410A Single Package Gas Heating / Electric Cooling

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

REPLACEMENT PARTS LIST

Roof Top Packaged Unit (RTU-1) Specification

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Model 581B Sizes to12 1 2Tons

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Advanced Product Data

Transcription:

WeatherExpert R Series Ultra High---Efficiency Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 07 --- 12 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS ECarrier Corporation 2016 Edition Date: 08/16 Printed in U.S.A. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: --- 7 --- 12 --- 05SB Replaces: --- 7 --- 12 --- 04SB

Job Data: Location: Buyer: Buyer P.O.#: Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: DESCRIPTION units are ultra high-efficiency, single-packaged electric cooling, gas heating units. Units utilize three stages of cooling capacity control with two-stage indoor fan motor speed control. All models are available with belt drive indoor fan motors with Variable Frequency Drive (VFD) speed controller and Direct Dive - ECM outdoor fan motor. Models use electro mechanical controls with Carrier s Comfort Control Logic and LED indicators. All units are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 340/360. Base Unit S Puron R (R-410A) HFC refrigerant S IEERsupto20.8withwithEERsupto13.5 S ASHRAE 90.1-2013 compliant S Rated in accordance with AHRI Standards 340/360 S Designed in accordance with Underwriters Laboratories Std 1995 S Listed by ETL S 3-stage cooling capacity control with crankcase heaters S Proven Multi Staged Scroll compressors with internal line-break overload protection S Single refrigerant circuit design with full face activated evaporator coil S Belt drive indoor fan and pulley system with Variable Frequency Drive (VFD) controller S High-efficiency ECM outdoor fan motor S Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain S Standard ambient cooling operation down to 40_F (4_C) with lower operation with integrated economizer. SystemVut controls allow operation down to 0_F (-18_C). All units operate up to 125_F (52_C). S Field convertible from vertical to horizontal airflow on all models. Size 08-12 models require an easy field-installed supply duct kit. S Two-inch disposable return air filters S Provisions for thru-the-bottom power entry capability as standard S Single point gas and electric connections S 24-volt control circuit protected with resettable circuit breaker S Permanently lubricated evaporator-fan motor S Totally enclosed condenser motors with permanently lubricated bearings STANDARD FEATURES S Low-pressure and high-pressure switch protection S Full perimeter base rail with built-in rigging adapters and fork truck slots S Sound levels as low as 82 db Cabinet S Innovative, easy starting, no-strip screw feature on unit access panels S Access panels with easy grip handles and tool-less filter access door S Pre -painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection S Fully insulated cabinet with foil faced insulation Refrigerant System S Precision sized TXV refrigerant metering devices S High capacity liquid line filter drier S High performance internally enhanced copper tube, aluminum fin coils with optional corrosion resistant coils Gas Heat S Exclusive IGC solid-state gas heat exchanger control for on-board diagnostics, anti -cycle protection, LED error code designation, burner control logic and energy saving indoor fan motor delay S Gas efficiencies up to 82% S Inducted draft gas heat combustion S Redundant gas valves with up to two stages of heating S Flame roll -out safety protector S Solid-state electronic direct spark ignition system Standard Limited Parts Warranty S 15-year gas heat exchanger parts - Stainless Steel S 10-year gas heat exchanger parts - Aluminized S 5-year compressor parts S 3-year SystemVut controller S 1-year parts 2

PERFORMANCE DATA Unit Operating Weight lb Heating Curb Weight lb Total Heating Capacity: Cooling Gross Total Capacity: Btuh INPUT Stage 1 Btuh at Condenser Air Temperature _F Stage 2 Btuh Gross Sensible Capacity: Btuh OUTPUT Compressor Power Input: kw Stage 1 kw Indoor Entering db _F wb _F Stage 2 kw Airflow CFM External Static Pressure in. wg Thermal Efficiency State % Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection Job Name Architect Engineer Contractor Unit Designation SUBMITTAL DATA Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 3

FACTORY-INSTALLED OPTIONS (FIOPs) j Economizer with DRY BULB sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with DRY BULB sensing and barometric ULTRA LOW LEAK Air Dampers requirements - plus 5-year limited parts warranty. EconoMi$er X. requirements - plus 5-year limited parts warranty. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric ULTRA LOW LEAK Air Dampers requirements - plus 5-year limited parts warranty. EconoMi$er X. requirements - plus 5-year limited parts warranty. EconoMi$er 2. j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Non-fused disconnect j HACR breaker j Powered 115-volt convenience outlet j Non-powered 115-volt convenience outlet j Return air smoke detector j Supply air smoke detector j CO 2 sensor j Condenser hail guard - louvered style j Special coating protection for evaporator and condenser coils j Hinged access panels j Patented Humidi-MiZer R adaptive dehumidification system (not available with SystemVut controls) j RTU Open multi -protocol controller communicates to LON, MODBUS*, BACnet { and Johnson N2 protocols. j SystemVut Controls: BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI. S Large full text - multi line display S Intuitive multi button navigation S USB Flash Port for data transfer S Built in i-vu R, CCN and BACnet S Refrigerant pressure from display S Quick LED Status - Run, Alert, Fault S Historical component runtime and starts S Conventional Stat or Sensor capabilities S Cooling Operation down to 0_F (-18_C) OPTIONAL EXTENDED WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start -Up and Optional Extended Warranty Price price pages for further information. * MODBUS is a registered trademark of Schneider Electric. { BACnet is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air---Conditioning Engineers). 4

FIELD-INSTALLED ACCESSORIES j Economizer with DRY BULB sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with DRY BULB sensing and barometric ULTRA LOW LEAK Air Dampers requirements. EconoMi$er X. requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric ULTRA LOW LEAK Air Dampers requirements. EconoMi$er X. requirements. EconoMi$er 2. j Display Kit for Variable Frequency Drive (VFD). Allows additional set up and diagnostics of the VFD controller. Kit includes display and cable. Kit can be used on size 07 thru 26 LC units. j Energy Demand System - wireless automated demand management and response controllers j Power exhaust - prop fan design j Roof curb - 14 inch (356 mm) tall j Roof curb - 24 inch (610 mm) tall j Thru-the -bottom connections-electrical only j Thru-the-bottom connections-electrical and gas j Condenser hail guard - louvered style j Flue shield (07 size only) j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Time Guard II compressor anti -cycle protection j Disconnect switch bracket, 08-12 only j Supply duct cover, 08-12 only j Thermostats and Sensors size 07-12 units require a three -stage cooling thermostat to perform at the listed operating efficiencies. Carrier offers a Honeywell branded T7350D 3 Cool/3 Heat Commercial Programmable Thermostat which provides the following features: S 7-day programmable S 365-day clock with holiday programming S Automatic Daylight Saving Time adjustment S Backlit display S Changeover selections: automatic or manual S Fan configurable: continuous or intermittent during occupied Economizer Sensors j Single dry bulb control j Single enthalpy control j Differential enthalpy control j CO 2 - wall mounted j CO 2 - duct mounted j CO 2 - unit mounted 5

CERTIFIED DIMENSION 07 C150085 6

CERTIFIED DIMENSION 07 C150086 7

CERTIFIED DIMENSION 08 C14080 8

CERTIFIED DIMENSION 08 C14081 9

NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN [ ] ARE IN MILLIMETERS. 2. CENTER OF GRAVITY 3. DIRECTION OF FLOW CONDENSER COIL 4-5/8 [117] LEFT 63-3/8 [1609] ELECTRICAL DISCONNECT LOCATION 4-5/8 [119] B 26-1/4 [666] D F 19-1/4 [490] 4-3/8 [110] 13-3/4 22-3/4 [578] 3-3/4 [95] 7-3/4 [196] [350] 35-3/4 [908] CERTIFIED DIMENSION 09-12 UNITED P.O. BOX 4808 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SUBMISSION OF THESE DRAWINGS OR DOCUMENTS AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE TECHNOLOGIES SYRACUSE, NY DOES NOT CONSTITUTE PART PERFORMANCE OR CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT CARRIER CARRIER 13221 ACCEPTANCE OF CONTRACT. CORPORATION'S WRITTEN CONSENT. CONNECTION SIZES B 2 1/2" [64] DIA POWER SUPPLY HOLE D 7/8" [22] DIA FIELD CONTROL WIRING HOLE E 3/4"-14 NPT CONDENSATE DRAIN F 7/8" [22] DIA FIELD CONVENIENCE OUTLET HOLE G 3/4"-14 NPT GAS CONNECTION 1-3/8 [35] ACCESSORY NO. 11-7/8 [302] 005 006 007 Z THRU-THE-BASE CHART THESE HOLES REQUIRED FOR USE CRBTMPWR005A00,006A00,007A00 THREADED CONDUIT SIZE WIRE USE REQ'D HOLE SIZES (MAX.) W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 1 1/4" POWER 1 1/2" [38.1] 3/4" PIPE GAS 1 3/4" [44.5] W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 1 1/2" POWER 2" [50.8] Z 3/4" PIPE GAS 1 3/4" [44.5] W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 2" POWER 2 1/2" [63.5] Z 3/4" PIPE GAS 1 3/4" [44.5] FOR "THRU-THE-BASEPAN" FACTORY OPTION, FITTINGS FOR X & Y ARE PROVIDED AS SPECIFIED ON "006". 4-3/8 [111] 57-3/8 [1456] OPTIONAL FACTORY INSTALLED DISCONNECT OR HACR OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET CONTROL BOX ACCESS PANEL INDOOR BLOWER ACCESS PANEL GAS HEAT ACCESS PANEL INDOOR BLOWER ACCESS PANEL HANDLE 14-5/8 [373] E STD. CONDENSATE DRAIN 31-3/4 [806] SUPPLY HORIZONTAL 46-1/8 [1172] FILTERS 34-1/2 [876] OUTSIDE 25-5/8 [650] RETURN HORIZONTAL FILTER/ECONOMIZER ACCESS PANEL (DISPOSABLE FILTERS) INDOOR COIL ACCESS PANEL PRESSURE GAUGE MANIFOLD ACCESS SLOT COMPRESSOR ACCESS PANEL CONDENSER COIL BACK HANDLE 61-1/8 [1552] 52-7/8 [1344] ECONOMIZER HOOD (VERTICAL) TWO-POSITION DAMPER HOOD (VERTICAL AND HORIZONTAL) (OPTIONAL) 29 [738] 22-1/2 [573] 20-1/2 [522] 18-1/8 [459] 15 [380] SEE THRU-THE-BASE CHART 44-1/4 [1124] W X Y Z 4 [100] RETURN VERTICAL FLUE HOOD 46-7/8 [1190] SUPPLY VERTICAL 26-3/4 [679] 34 [863] REMOVABLE PLATE E ALT. CONDENSATE DRAIN OPENING IN BASEPAN 26 [660] 4-7/8 [124] 5-3/4 [146] 41-1/2 [1055] 6-1/4 [159] 12-5/8 [321] 44-3/8 [1126] RETURN SUPPLY 2-5/8 TYP [67] BASE RAIL WIDTH 49-1/2 [1257] G 115-7/8 [2942] 7-7/8 [198] FRONT 6-1/8 [154] 6-5/8 6-7/8 [167] [175] 6-1/8 41-1/2 [1056] [154] SUPPLY RETURN RIGHT BAROMETRIC / POWER RELIEF EXHAUST FLOW SHEET 1 OF 2 DATE 05/08/13 SUPERCEDES - 09-12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 500390 REV A C13316 10

CERTIFIED DIMENSION 09-12 UNIT STD UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) C.G. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 09 1606 728 406 184 410 186 397 180 393 178 58 [1473] 32 [812] 20 5/8 [524] 12 1606 728 406 184 410 186 397 180 393 178 58 [1473] 32 [812] 20 5/8 [524] STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT & WITHOUT PACKAGING. FOR OPTIONS & ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. UNITED TECHNOLOGIES CARRIER P.O. BOX 4808 SYRACUSE, NY 13221 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT CARRIER CORPORATION'S WRITTEN CONSENT. 81-1/4 [2064.9] 32-3/4 [832.5] SUBMISSION OF THESE DRAWINGS OR DOCUMENTS DOES NOT CONSTITUTE PART PERFORMANCE OR ACCEPTANCE OF CONTRACT. CORNER A CORNER B HORIZONTAL ECONOMIZER HOOD (OPTIONAL) 23-1/4 [590.5] Y RETURN CORNER D X CORNER C SUPPLY TOP 51-1/8 [1298] 46-7/16 [1179] Z FRONT SUPPLY RETURN HORIZONTAL ECONOMIZER SHEET 2 OF 2 DATE 05/08/13 SUPERCEDES - 09-12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 500390 REV A C13317 11

ROOF CURB DETAILS SIZE 07 UNITS ROOF CURB ACCESSORY # CRRFCURB003A01 CRRFCURB004A01 6 3/64" [153.5] 26" [660.4] 4 3/16" [106.0] [76.2] 3" 15 13/16" [401.6] 1 3/4" [44.5] 1 3/4" [44.5] 1/4" [7.0] 4 9/16" [115.5] A 14" [356] 24" [610] NOTES: 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS: 25.4 [1"] THK. POLYURETHANE FOAM, 44.5 [1-3/4] # DENSITY. 3. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 4. ROOFCURB: 18 GAGE STEEL. 5. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB). 6. SERVICE CLEARANCE 4 FEET ON EACH SIDE. 7. DIRECTION OF FLOW. 8. CONNECTOR PACKAGE CRBTMPWR002A01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWR004A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. CONNECTOR PKG. ACC. GAS CONNECTION TYPE GAS FITTING CRBTMPWR002A01 THRU THE CURB CRBTMPWR004A01 THRU THE BOTTOM POWER WIRING FITTING 3/4" [19] NPT 1 1/4" [31.7] NPT CONTROL WIRING FITTING ACCESSORY CONVENIENCE OUTLET WIRING CONNECTOR 1/2" [12.7] NPT 1/2" [12.7] NPT 1 3/4" [44.5] 53 1/2" [1358.9] 11.42" [290.0] 14 3/4" [374.7] 2 1/4" [57.2] "A" 1.00" [25.4] 12-1/2" [317.5] WIDE INSULATED DECK PANELS 9-15/16" [252.4] WIDE INSULATED DECK PANEL 1 3/4" [44.4] 32 9/16" [827.1] 1 3/4" [44.4] 81 3/4" [2076.3] SECTION THRU SIDE GAS SERVICE PLATE THRU THE CURB DRILL HOLE 2" [50.8] @ ASSEMBLY (IF REQUIRED) (SEE NOTE #8) 20-3/4" [513] INSIDE 2-3/8" [61] SEE NOTE #2 40 3/16" [1020.8] SUPPLY OPENING RETURN OPENING 23 1/16" [585.8] VIEW "B" CORNER DETAIL SUPPLY RETURN 1-3/4" TYP [44.5] 31 17/32" [800.9] 15 15/32 [392.9] GASKET (SUPPLIED WITH CURB) DUCT (FIELD SUPPLIED) UNIT 7/16" [11] NAIL (FIELD SUPPLIED) TYPICAL (4) SIDES COUNTER FLASHING (FIELD SUPPLIED) "A" 4' 2" [1270.0] 6' 6-1/4" [1987.5] SUPPLY RETURN RIGID INSULATION (FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) CANT STRIP (FIELD SUPPLIED) ROOFING MATERIAL (FIELD SUPPLIED) SEE VIEW "B" CERTIFIED DRAWING DRAWING RELEASE LEVEL: PRODUCTION UNLESS OTHERWISE SPECIFIED THIRD ANGLE DIMENSIONS ARE IN INCHES PROJECTION TOLERANCES ON: THIS DOCUMENT AND THE INFORMATION CONTAINED THEREIN 1 DEC 2 DEC 3 DEC ANG IS PROPRIETARY TO CARRIER CORPORATION AND SHALL NOT BE USED OR DISCLOSED TO OTHERS, IN WHOLE OR IN PART, MATERIAL - - - - WITHOUT THE WRITTEN AUTHORIZATION OF CARRIER CORPORATION. AUTHORIZATION NUMBER TITLE 1029120 CURB ASY, ROOF ENGINEERING MANUFACTURING C REV 6' 61/4" WAS 6' 7 1/6", 4'2' WAS 4' 2 13/16"; 18 GA WAS 16 GA.; 15 13/16" WAS 15 15/16"; NAIL FIELD SUPPLIED WAS WITH CURB REVISION RECORD 4/22/13 DATE MMC BY CHK'D APP'D 1067898 ECN NO. ENGINEERING REQUIREMENTS - - - - SIZE DRAWING NUMBER REV T-005, Y-002 DRAFTER CHECKER D 50HJ405012 C WEIGHT: - MMC 12/16/09 - - SHEET 5 OF 5 SURFACE FINISH MODEL (INTERNAL SCALE DISTRIBUTION MFG/PURCH USE ONLY) NEXT DRAWING - PURCH - N/A - - - - - - C13311 12

ROOF CURB DETAILS SIZE 08-12 UNITS C10772B 13

14