WeatherExpert R Series Ultra High---Efficiency Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 07 --- 12 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS ECarrier Corporation 2016 Edition Date: 08/16 Printed in U.S.A. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: --- 7 --- 12 --- 05SB Replaces: --- 7 --- 12 --- 04SB
Job Data: Location: Buyer: Buyer P.O.#: Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: DESCRIPTION units are ultra high-efficiency, single-packaged electric cooling, gas heating units. Units utilize three stages of cooling capacity control with two-stage indoor fan motor speed control. All models are available with belt drive indoor fan motors with Variable Frequency Drive (VFD) speed controller and Direct Dive - ECM outdoor fan motor. Models use electro mechanical controls with Carrier s Comfort Control Logic and LED indicators. All units are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 340/360. Base Unit S Puron R (R-410A) HFC refrigerant S IEERsupto20.8withwithEERsupto13.5 S ASHRAE 90.1-2013 compliant S Rated in accordance with AHRI Standards 340/360 S Designed in accordance with Underwriters Laboratories Std 1995 S Listed by ETL S 3-stage cooling capacity control with crankcase heaters S Proven Multi Staged Scroll compressors with internal line-break overload protection S Single refrigerant circuit design with full face activated evaporator coil S Belt drive indoor fan and pulley system with Variable Frequency Drive (VFD) controller S High-efficiency ECM outdoor fan motor S Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain S Standard ambient cooling operation down to 40_F (4_C) with lower operation with integrated economizer. SystemVut controls allow operation down to 0_F (-18_C). All units operate up to 125_F (52_C). S Field convertible from vertical to horizontal airflow on all models. Size 08-12 models require an easy field-installed supply duct kit. S Two-inch disposable return air filters S Provisions for thru-the-bottom power entry capability as standard S Single point gas and electric connections S 24-volt control circuit protected with resettable circuit breaker S Permanently lubricated evaporator-fan motor S Totally enclosed condenser motors with permanently lubricated bearings STANDARD FEATURES S Low-pressure and high-pressure switch protection S Full perimeter base rail with built-in rigging adapters and fork truck slots S Sound levels as low as 82 db Cabinet S Innovative, easy starting, no-strip screw feature on unit access panels S Access panels with easy grip handles and tool-less filter access door S Pre -painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection S Fully insulated cabinet with foil faced insulation Refrigerant System S Precision sized TXV refrigerant metering devices S High capacity liquid line filter drier S High performance internally enhanced copper tube, aluminum fin coils with optional corrosion resistant coils Gas Heat S Exclusive IGC solid-state gas heat exchanger control for on-board diagnostics, anti -cycle protection, LED error code designation, burner control logic and energy saving indoor fan motor delay S Gas efficiencies up to 82% S Inducted draft gas heat combustion S Redundant gas valves with up to two stages of heating S Flame roll -out safety protector S Solid-state electronic direct spark ignition system Standard Limited Parts Warranty S 15-year gas heat exchanger parts - Stainless Steel S 10-year gas heat exchanger parts - Aluminized S 5-year compressor parts S 3-year SystemVut controller S 1-year parts 2
PERFORMANCE DATA Unit Operating Weight lb Heating Curb Weight lb Total Heating Capacity: Cooling Gross Total Capacity: Btuh INPUT Stage 1 Btuh at Condenser Air Temperature _F Stage 2 Btuh Gross Sensible Capacity: Btuh OUTPUT Compressor Power Input: kw Stage 1 kw Indoor Entering db _F wb _F Stage 2 kw Airflow CFM External Static Pressure in. wg Thermal Efficiency State % Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection Job Name Architect Engineer Contractor Unit Designation SUBMITTAL DATA Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 3
FACTORY-INSTALLED OPTIONS (FIOPs) j Economizer with DRY BULB sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with DRY BULB sensing and barometric ULTRA LOW LEAK Air Dampers requirements - plus 5-year limited parts warranty. EconoMi$er X. requirements - plus 5-year limited parts warranty. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric ULTRA LOW LEAK Air Dampers requirements - plus 5-year limited parts warranty. EconoMi$er X. requirements - plus 5-year limited parts warranty. EconoMi$er 2. j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Non-fused disconnect j HACR breaker j Powered 115-volt convenience outlet j Non-powered 115-volt convenience outlet j Return air smoke detector j Supply air smoke detector j CO 2 sensor j Condenser hail guard - louvered style j Special coating protection for evaporator and condenser coils j Hinged access panels j Patented Humidi-MiZer R adaptive dehumidification system (not available with SystemVut controls) j RTU Open multi -protocol controller communicates to LON, MODBUS*, BACnet { and Johnson N2 protocols. j SystemVut Controls: BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI. S Large full text - multi line display S Intuitive multi button navigation S USB Flash Port for data transfer S Built in i-vu R, CCN and BACnet S Refrigerant pressure from display S Quick LED Status - Run, Alert, Fault S Historical component runtime and starts S Conventional Stat or Sensor capabilities S Cooling Operation down to 0_F (-18_C) OPTIONAL EXTENDED WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start -Up and Optional Extended Warranty Price price pages for further information. * MODBUS is a registered trademark of Schneider Electric. { BACnet is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air---Conditioning Engineers). 4
FIELD-INSTALLED ACCESSORIES j Economizer with DRY BULB sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric Standard Air Leak Dampers Diagnostic (FDD) requirements. EconoMi$er X. Diagnostic (FDD) requirements. EconoMi$er 2. j Economizer with DRY BULB sensing and barometric ULTRA LOW LEAK Air Dampers requirements. EconoMi$er X. requirements. EconoMi$er 2. j Economizer with ENTHALPY sensing and barometric ULTRA LOW LEAK Air Dampers requirements. EconoMi$er X. requirements. EconoMi$er 2. j Display Kit for Variable Frequency Drive (VFD). Allows additional set up and diagnostics of the VFD controller. Kit includes display and cable. Kit can be used on size 07 thru 26 LC units. j Energy Demand System - wireless automated demand management and response controllers j Power exhaust - prop fan design j Roof curb - 14 inch (356 mm) tall j Roof curb - 24 inch (610 mm) tall j Thru-the -bottom connections-electrical only j Thru-the-bottom connections-electrical and gas j Condenser hail guard - louvered style j Flue shield (07 size only) j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Time Guard II compressor anti -cycle protection j Disconnect switch bracket, 08-12 only j Supply duct cover, 08-12 only j Thermostats and Sensors size 07-12 units require a three -stage cooling thermostat to perform at the listed operating efficiencies. Carrier offers a Honeywell branded T7350D 3 Cool/3 Heat Commercial Programmable Thermostat which provides the following features: S 7-day programmable S 365-day clock with holiday programming S Automatic Daylight Saving Time adjustment S Backlit display S Changeover selections: automatic or manual S Fan configurable: continuous or intermittent during occupied Economizer Sensors j Single dry bulb control j Single enthalpy control j Differential enthalpy control j CO 2 - wall mounted j CO 2 - duct mounted j CO 2 - unit mounted 5
CERTIFIED DIMENSION 07 C150085 6
CERTIFIED DIMENSION 07 C150086 7
CERTIFIED DIMENSION 08 C14080 8
CERTIFIED DIMENSION 08 C14081 9
NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN [ ] ARE IN MILLIMETERS. 2. CENTER OF GRAVITY 3. DIRECTION OF FLOW CONDENSER COIL 4-5/8 [117] LEFT 63-3/8 [1609] ELECTRICAL DISCONNECT LOCATION 4-5/8 [119] B 26-1/4 [666] D F 19-1/4 [490] 4-3/8 [110] 13-3/4 22-3/4 [578] 3-3/4 [95] 7-3/4 [196] [350] 35-3/4 [908] CERTIFIED DIMENSION 09-12 UNITED P.O. BOX 4808 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SUBMISSION OF THESE DRAWINGS OR DOCUMENTS AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE TECHNOLOGIES SYRACUSE, NY DOES NOT CONSTITUTE PART PERFORMANCE OR CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT CARRIER CARRIER 13221 ACCEPTANCE OF CONTRACT. CORPORATION'S WRITTEN CONSENT. CONNECTION SIZES B 2 1/2" [64] DIA POWER SUPPLY HOLE D 7/8" [22] DIA FIELD CONTROL WIRING HOLE E 3/4"-14 NPT CONDENSATE DRAIN F 7/8" [22] DIA FIELD CONVENIENCE OUTLET HOLE G 3/4"-14 NPT GAS CONNECTION 1-3/8 [35] ACCESSORY NO. 11-7/8 [302] 005 006 007 Z THRU-THE-BASE CHART THESE HOLES REQUIRED FOR USE CRBTMPWR005A00,006A00,007A00 THREADED CONDUIT SIZE WIRE USE REQ'D HOLE SIZES (MAX.) W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 1 1/4" POWER 1 1/2" [38.1] 3/4" PIPE GAS 1 3/4" [44.5] W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 1 1/2" POWER 2" [50.8] Z 3/4" PIPE GAS 1 3/4" [44.5] W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y 2" POWER 2 1/2" [63.5] Z 3/4" PIPE GAS 1 3/4" [44.5] FOR "THRU-THE-BASEPAN" FACTORY OPTION, FITTINGS FOR X & Y ARE PROVIDED AS SPECIFIED ON "006". 4-3/8 [111] 57-3/8 [1456] OPTIONAL FACTORY INSTALLED DISCONNECT OR HACR OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET CONTROL BOX ACCESS PANEL INDOOR BLOWER ACCESS PANEL GAS HEAT ACCESS PANEL INDOOR BLOWER ACCESS PANEL HANDLE 14-5/8 [373] E STD. CONDENSATE DRAIN 31-3/4 [806] SUPPLY HORIZONTAL 46-1/8 [1172] FILTERS 34-1/2 [876] OUTSIDE 25-5/8 [650] RETURN HORIZONTAL FILTER/ECONOMIZER ACCESS PANEL (DISPOSABLE FILTERS) INDOOR COIL ACCESS PANEL PRESSURE GAUGE MANIFOLD ACCESS SLOT COMPRESSOR ACCESS PANEL CONDENSER COIL BACK HANDLE 61-1/8 [1552] 52-7/8 [1344] ECONOMIZER HOOD (VERTICAL) TWO-POSITION DAMPER HOOD (VERTICAL AND HORIZONTAL) (OPTIONAL) 29 [738] 22-1/2 [573] 20-1/2 [522] 18-1/8 [459] 15 [380] SEE THRU-THE-BASE CHART 44-1/4 [1124] W X Y Z 4 [100] RETURN VERTICAL FLUE HOOD 46-7/8 [1190] SUPPLY VERTICAL 26-3/4 [679] 34 [863] REMOVABLE PLATE E ALT. CONDENSATE DRAIN OPENING IN BASEPAN 26 [660] 4-7/8 [124] 5-3/4 [146] 41-1/2 [1055] 6-1/4 [159] 12-5/8 [321] 44-3/8 [1126] RETURN SUPPLY 2-5/8 TYP [67] BASE RAIL WIDTH 49-1/2 [1257] G 115-7/8 [2942] 7-7/8 [198] FRONT 6-1/8 [154] 6-5/8 6-7/8 [167] [175] 6-1/8 41-1/2 [1056] [154] SUPPLY RETURN RIGHT BAROMETRIC / POWER RELIEF EXHAUST FLOW SHEET 1 OF 2 DATE 05/08/13 SUPERCEDES - 09-12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 500390 REV A C13316 10
CERTIFIED DIMENSION 09-12 UNIT STD UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) C.G. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 09 1606 728 406 184 410 186 397 180 393 178 58 [1473] 32 [812] 20 5/8 [524] 12 1606 728 406 184 410 186 397 180 393 178 58 [1473] 32 [812] 20 5/8 [524] STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT & WITHOUT PACKAGING. FOR OPTIONS & ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. UNITED TECHNOLOGIES CARRIER P.O. BOX 4808 SYRACUSE, NY 13221 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT CARRIER CORPORATION'S WRITTEN CONSENT. 81-1/4 [2064.9] 32-3/4 [832.5] SUBMISSION OF THESE DRAWINGS OR DOCUMENTS DOES NOT CONSTITUTE PART PERFORMANCE OR ACCEPTANCE OF CONTRACT. CORNER A CORNER B HORIZONTAL ECONOMIZER HOOD (OPTIONAL) 23-1/4 [590.5] Y RETURN CORNER D X CORNER C SUPPLY TOP 51-1/8 [1298] 46-7/16 [1179] Z FRONT SUPPLY RETURN HORIZONTAL ECONOMIZER SHEET 2 OF 2 DATE 05/08/13 SUPERCEDES - 09-12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 500390 REV A C13317 11
ROOF CURB DETAILS SIZE 07 UNITS ROOF CURB ACCESSORY # CRRFCURB003A01 CRRFCURB004A01 6 3/64" [153.5] 26" [660.4] 4 3/16" [106.0] [76.2] 3" 15 13/16" [401.6] 1 3/4" [44.5] 1 3/4" [44.5] 1/4" [7.0] 4 9/16" [115.5] A 14" [356] 24" [610] NOTES: 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS: 25.4 [1"] THK. POLYURETHANE FOAM, 44.5 [1-3/4] # DENSITY. 3. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 4. ROOFCURB: 18 GAGE STEEL. 5. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB). 6. SERVICE CLEARANCE 4 FEET ON EACH SIDE. 7. DIRECTION OF FLOW. 8. CONNECTOR PACKAGE CRBTMPWR002A01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWR004A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. CONNECTOR PKG. ACC. GAS CONNECTION TYPE GAS FITTING CRBTMPWR002A01 THRU THE CURB CRBTMPWR004A01 THRU THE BOTTOM POWER WIRING FITTING 3/4" [19] NPT 1 1/4" [31.7] NPT CONTROL WIRING FITTING ACCESSORY CONVENIENCE OUTLET WIRING CONNECTOR 1/2" [12.7] NPT 1/2" [12.7] NPT 1 3/4" [44.5] 53 1/2" [1358.9] 11.42" [290.0] 14 3/4" [374.7] 2 1/4" [57.2] "A" 1.00" [25.4] 12-1/2" [317.5] WIDE INSULATED DECK PANELS 9-15/16" [252.4] WIDE INSULATED DECK PANEL 1 3/4" [44.4] 32 9/16" [827.1] 1 3/4" [44.4] 81 3/4" [2076.3] SECTION THRU SIDE GAS SERVICE PLATE THRU THE CURB DRILL HOLE 2" [50.8] @ ASSEMBLY (IF REQUIRED) (SEE NOTE #8) 20-3/4" [513] INSIDE 2-3/8" [61] SEE NOTE #2 40 3/16" [1020.8] SUPPLY OPENING RETURN OPENING 23 1/16" [585.8] VIEW "B" CORNER DETAIL SUPPLY RETURN 1-3/4" TYP [44.5] 31 17/32" [800.9] 15 15/32 [392.9] GASKET (SUPPLIED WITH CURB) DUCT (FIELD SUPPLIED) UNIT 7/16" [11] NAIL (FIELD SUPPLIED) TYPICAL (4) SIDES COUNTER FLASHING (FIELD SUPPLIED) "A" 4' 2" [1270.0] 6' 6-1/4" [1987.5] SUPPLY RETURN RIGID INSULATION (FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) CANT STRIP (FIELD SUPPLIED) ROOFING MATERIAL (FIELD SUPPLIED) SEE VIEW "B" CERTIFIED DRAWING DRAWING RELEASE LEVEL: PRODUCTION UNLESS OTHERWISE SPECIFIED THIRD ANGLE DIMENSIONS ARE IN INCHES PROJECTION TOLERANCES ON: THIS DOCUMENT AND THE INFORMATION CONTAINED THEREIN 1 DEC 2 DEC 3 DEC ANG IS PROPRIETARY TO CARRIER CORPORATION AND SHALL NOT BE USED OR DISCLOSED TO OTHERS, IN WHOLE OR IN PART, MATERIAL - - - - WITHOUT THE WRITTEN AUTHORIZATION OF CARRIER CORPORATION. AUTHORIZATION NUMBER TITLE 1029120 CURB ASY, ROOF ENGINEERING MANUFACTURING C REV 6' 61/4" WAS 6' 7 1/6", 4'2' WAS 4' 2 13/16"; 18 GA WAS 16 GA.; 15 13/16" WAS 15 15/16"; NAIL FIELD SUPPLIED WAS WITH CURB REVISION RECORD 4/22/13 DATE MMC BY CHK'D APP'D 1067898 ECN NO. ENGINEERING REQUIREMENTS - - - - SIZE DRAWING NUMBER REV T-005, Y-002 DRAFTER CHECKER D 50HJ405012 C WEIGHT: - MMC 12/16/09 - - SHEET 5 OF 5 SURFACE FINISH MODEL (INTERNAL SCALE DISTRIBUTION MFG/PURCH USE ONLY) NEXT DRAWING - PURCH - N/A - - - - - - C13311 12
ROOF CURB DETAILS SIZE 08-12 UNITS C10772B 13
14