LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Similar documents
Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Excel-EN Conventional Fire Control Panel

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

5000 INSTALLATION GUIDE

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Installation and user manual for the BiWire / Conventional Repeater Panel

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Menvier Fire System MF9300

Intelligent Security & Fire Ltd

Control Panel Engineering and Commissioning Instructions

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

OPERATION AND INSTALLATION MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Surveyor Envoy-MINI 4

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Conventional Fire Alarm System 2014 V1.2

Fire Alarm Control Panel. System Maintenance and Log Book

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Operation and Maintenance Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Model 17A00 Expansion Enclosure

Intruder - Fire - Water Combined Alarm

System 800 Addressable Fire Detection & Alarm System

Door Release Power Supply

Application, Installation, Operation & Maintenance Manual

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

Installation and Operating Instructions

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

FEC400 Series. Installation Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

User Operation Manual

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

QA16 Addressable System

VSN PLUS VSN 4 PLUS ; VSN 8 PLUS ; VSN 12 PLUS

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

ORION Mini-Rep INSTALLATION MANUAL

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

GAS SUPRESSION CONTROL PANEL:

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

Unity DAU Voice Alarm System

SOLO Single Loop Addressable Fire Control Panel

Conventional Fire Control Panel

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

EVO192 v3.0 Fire and Burglary What s New

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Conventional Leaflets

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Control Panel User Guide

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Installation Instructions 4 Zone Fire Panel

Intelligent Security & Fire Ltd

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL & MAINTENANCE GUIDE OG OO

FEC403EN Installation Manual

4 wire conventional alarm system

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Deaf & Hearing Impaired RadioLINK Alarm System

MR-2602 Two Zone Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Control Panel User Guide (TO BE RETAINED BY THE USER)

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

ZSC100 Gas Detection and Alarm System Controller

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

SECURIT 700L PLUS ENGINEERING MANUAL

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

New Silent Alert Fire Safe System

Installation Manual Premier 412/816/832. Issue 10

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Transcription:

LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998 For Technical advice & Servicing contact - +44 (0) 1268 56 3256 This publication is issued to provide outline information only and is not deemed to form part of any offer or contract Our policy is one of continual improvement and we reserve the right to vary details without prior notice. 61640610 issue 5

INSTALLATION INFORMATION General Installation of this product must be carried out using the information given in this leaflet by a qualified electrician. BEFORE INSTALLATION ENSURE THE ELECTRICAL SUPPLY IS ISOLATED. Installation of this product must be carried out using the methods and equipment specified in BS5839 Pt1 and EN54. Consult the supplier if the equipment is to be installed in an environment where the ambient temperature regularly exceeds 30 ºC (86 ºF) Mounting location considerations The fire alarm control panel should be mounted near to a permanent, low fire risk, Entry / Exit, for easy access by the Emergency Services. The panel should not be mounted in direct sunlight, or in a place where the ambient temperature is above 30 o C (86 o F) Mains must not be capable of being accidentally disconnected and the isolating switch should clearly state : FIRE ALARM - DO NOT SWITCH OFF Anti static precautions should be taken when installing the panel BATTERY PCB TERMINAL BLOCKS CABLE ENTRY POINTS TOP & BOTTOM 2 CONNECTING THE MAINS & BATTERY 2.1 Connect mains wiring to terminal block in the back box as marked. Note: AN EARTH CONNECTION MUST BE MADE TO THE TERMINAL BLOCK AS MARKED. 2.2 With the mains supply isolated, replace the lower plastic cover assembly containing the PCB. Ensure the battery wires are routed to the top left-hand side of the back box and the transformer secondary wires are routed towards the right hand side. The PCB locating holes should engage on the metal mounting tabs shown in figure 2. 2.3 Reconnect the transformer secondary wires to the PCB terminals marked AC. Note: Polarisation of this connection is unimportant 2.4 Fit and tighten the two securing screws that hold the PCB moulding in place. Ensure that the moulding has properly engaged at the bottom of the metal back box. Do not over tighten two retaining screws. 2.5 Fit battery into left-hand side of the back box and connect battery using leads supplied. Ensure correct polarity is always observed. The panel is now active and will indicate a POWER FAULT and GENERAL FAULT until the mains supply is re-instated, and the panel RESET. 2.6 Instate the mains supply, enter access code then press the RESET button. 2.7 Check panel is operating normally. The panel should only show the green POWER ON indicator. TOP COVER FIXING POINTS BOTTOM COVER FIXING POINTS METALWORK HOUSING SECONDARY TRANSFORMER WIRES 2.8 You have now proved that the panel is free of faults. 3 EXTERNAL WIRING - DETECTOR ZONE CONNECTION This fire alarm control panel is supplied with End Of Line Resistor/s for the zone circuit/s. This is for use with just manual call points (Break Glass) units, however if removable smoke/heat detectors are used the End Of Line Resistor/s must be replaced with Active End Of Line Device/s (ZF19). Please note these units are polarised. 3.1 DISCONNECT MAINS SUPPLY & BATTERY. FIGURE 1 - Top cover removed for clarity 1 MOUNTING INSTRUCTIONS 1.1 In order to minimise the installation time, it is strongly recommended, that the following procedure is followed. 1.2 Remove plastic fascia by removing the two screws from the top plastic cover. 1.3 Disconnect the two secondary transformer wires from the terminals marked AC~ on the PCB. These are located on the right-hand side of the fire panel. 1.4 Remove the two screws that hold the bottom plastic cover in place, then lift away from fire panel housing. Store cover assembly in a safe place to prevent damage during initial installation. Note: DO NOT REMOVE THE PCB FROM THE PLASTIC MOULDING. 1.5 Using the back box as a Drill template, mark through fixing positions, prepare the fixing holes, and fit onto wall using an appropriate mounting system. Ensure the back box is not contaminated with drilling debris, e.g. brick dust, as this can adversely affect the electronic circuitry. 3.2 Connect the zone wiring, one zone at a time, transferring either the End Of Line Resistor or Active End Of Line Device (ZF19), if removable smoke/heat detectors are being employed. The ZF19 devices are polarised and should be connected with Red/Orange wire to the +ve and Black to the ve. See Figure 3 & 6 for typical application. 3.3 Repeat the above procedure until all the required circuits are connected. 3.4 Connect the sounder wiring one circuit at a time, transferring the end of line resistor to the last sounder on that circuit. 3.5 Repeat the above procedure until all the required sounder circuits are connected. 3.6 ReInstate the mains supply, enter access code then press the RESET button. 3.7 Refit plastic fascia. Do not over tighten two retaining screws. 1.6 Prepare cable entries via the 20mm knockouts provided in the top and rear of back box using appropriate glanding system. 1.7 Remove any debris from the back box.

Auxiliary 24V Supply This is specifically not for fire protection devices. 50mA maximum. Nominal Voltage 25.3V (+2.7V / -1V) Fuse rating - F125mA Auxiliary Relay Volt free change over contacts rated at 1A 30VDC Fuse Rating 1A Note, the Auxiliary relay is configured as a fault relay, as standard (EN54 requirement), however the relay can be configured as an auxiliary fire relay, by moving a jumper link from the fault position to the fire position on the back of the PCB. FIGURE 2a - TERMINAL ARRANGEMENT AUXILIARY RELAY 1 2 3 FAULT NC C NO FIRE NO C NC The N/C and N/O contacts change position, when the jumper is moved to the fire position. Class Change Activated by using volt free N/O contacts between the -ve of AUX 24V output and the CLASS CHANGE output. See Figure 5 for typical application. FIGURE 2b - FAULT / FIRE AUXILIARY RELAY GENERAL DESCRIPTION Options included that are covered by EN54 Test Condition (10.0) Fire Alarm Devices (7.8) Ancillary functions provided but not required by EN54 Class change Repeater Accessories: The panel is designed for use with CHLORIDE BARDIC ZF range of fire accessories. TECHNICAL SPECIFICATIONS Power Supply requirements 230Vac +10-15% 50Hz Maximum Power consumption 50VA Fuse rating - T125mA The mains supply should be carefully wired using flat twin and earth of not less than 1mm 2 between the mains connector block and an externally mounted secure switched fused spur outlet with contact separation of at least 3mm. The switched spur unit should be fused with a 2A fuse. Battery 24 Hour standby 1 x 12 V 2.6 Ah (minimum) Fuse rating - F1.6A Weight 4.2 Kg (including 2.6 Ah battery & carton) approx. Detection Circuits No more than 30 devices of any type per zone. 20 smoke or heat detectors maximum per zone. 30 Call Points maximum per zone. Alarm Sounder Circuits 300mA total through 2 circuits. Nominal Voltage 25.3V (+2.7V / -1V) Fuse rating - F315mA Cabling Unless otherwise recommended, and taking into account voltage drop, not less than 1mm 2 is recommended. Sounder circuits should use cable that is fire proof. All cabling should be earthed to the metal back box via the cable gland. Conductors carrying fire alarm power signals should be separated from conductors used for carrying other systems. OPERATING INSTRUCTIONS Access to SUPERVISOR MODE for panel operation:- To operate this fire alarm control panel, it is necessary to gain access to the Supervisor Mode, to do this enter the four digit security password code, on the yellow push buttons. This security code should have been given to the responsible person on system hand over. After entering the correct code the Supervisor Mode LED will illuminate. The panel will time out of Supervisor Mode if the RESET button is pressed or 20 seconds have elapsed since the last button was pressed. The following functions can all be employed in the Supervisor Mode. SOUNDERS ON/OFF If the sounders are silent, because either the panel is in alarm and the sounders have been Silenced, or if there is no alarm, the sounders will be activated by pressing this button. If the sounders are on, and they are to be switched off, then press the SOUNDERS ON/OFF push button to silence the alarm. RESET This will cause all faults and fires conditions to be cancelled, if a fault still exists then it will re-appear within 10 seconds of this reset. MUTE PANEL To silence the panel s internal buzzer press MUTE PANEL push button. The panel will continue to beep at a reduced rate until the condition causing the buzzer to sound is rectified or reset. LAMP TEST Hold down SELECT / LAMP TEST push button for a minimum of two seconds. Release once the test is complete.

DISABLEMENT AND TEST FUNCTIONS: - Test Zone This feature allows one person to check the detectors and sounders without having to return to the panel during the testing routine. When the appropriate zone is in test mode and a detector is activated, the sounder circuit/s will operate for a few seconds and then automatically reset. Access SUPERVISOR MODE" Hold down ADVANCE push button for at least 2 seconds. The Test LED will light and the Zone 1 Fault LED will flash at a fast rate (faster than the fault warning flash rate). If you do not wish to test this zone then press ADVANCE to move to the second zone. To put the zone into Test press SELECT / LAMP TEST. If the zone is in Test, the LED is constant, and if it is to be deselected then press SELECT / LAMP TEST again. Press RESET button at any stage to accept settings and revert to normal operating mode. Disable Zone Repeat the above process until the Test LED goes out and the Disabled LED illuminates. Use the ADVANCE and SELECT / LAMP TEST keys as previously described to select/deselect zones that are to be disabled. Press RESET button at any stage to accept settings and revert to normal operating mode. Disable Sounders After progressing through all the Test & Disable zones functions the Sounder Fault / Disable LED will illuminate. If the sounders are to be disabled/enabled use SELECT / LAMP TEST push button. Press RESET button at any stage to accept settings and revert to normal operating mode or press ADVANCE once more to exit the panel from this test/disable loop. MAINTENANCE INFORMATION All the components of this panel have been selected for the intended purpose, and are expected to operate within their specification when the environmental conditions outside the panel comply with class 3k5 of IEC 721-3-3. The battery has a manufacturers recommended life expectancy of 3-5 years.

7<3,&$/),5(3$1(/$33/,&$7,216 * See note below Figure 3 - DETECTOR CIRCUIT Figure 4 - SOUNDER CIRCUIT * See note below Figure 5 - CLASS CHANGE Figure 6 - CALL POINT * If removable Detectors are used on the Zone Circuit, the End of Line Resistor MUST be replaced with an active End Of Line Module ZF19.

&$86($1'())(&7&+$57 Sounder General Fire General Fault Zone Fire Zone Fault / Disable/ Test Sounder Fault / Disable System Fault Power Power Fault Disabled Test Supervisor Mode Code Entry Mode Buzzer Notes Normal condition. System operating correctly in standby mode. Fire condition. Detector or call point operated. Detector zone circuit fault. A detector has been removed or circuit wiring open or short-circuited. Alarm sounder circuit fault. Alarm circuit has open or short circuited or its protection fuse has ruptured. Disabled zone. Zone circuit has been disabled by Engineer for maintenance or test purposes. Disabled sounder circuits. Contacts have been disabled by engineer for maintenance or test purposes. Watchdog tripped. ROM/RAM failure. Test mode. Selected zone is being tested. Total power failure. Partial power failure. a) Battery flat / failed / disconnected or rupture of battery cable or fuse (Fast flashing). b) Mains supply faulty or charger fault. c) 24V supply voltage faulty - used for detector and alarm zones. Auxiliary 24V supply voltage faulty or rupture fuse. System Failure. Supervisor Mode (Resets after 20 seconds after last button pressed) = OFF = ON = Pulsed on/off with equal duty cycle = Pulsed intermittently every 8 seconds when alarm or fault indication has been silenced; or for Test Mode this state occurs 10 minutes after last triggered zone under test, as a reminder that the panel is still in Test Mode.

SITE NAME... SITE ADDRESS... ),5(3$1(//2*%22. PERSON RESPONSIBLE... SYSTEM INSTALLED BY... DATE INSTALLED... DATE TELEPHONE DATE COMMISSIONED MAINTAINED UNDER CONTRACT BY SERVICE CONTRACT No. UNTIL TYPE & QTY LOCATION No DETECTOR CALL POINT SOUNDER QTY ZONE 1 ZONE 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 For Technical advice & Servicing contact - +44 (0) 1268 56 3256

DATE W K L Y Q T L Y LAMP TEST ),5(3$1(/(9(175(*,67(5 ZONE EVENT ACTION REQUIRED COMPLETED NAME