Ref. No. RRSS/CH-18/ RIDF Dated : ii) Submission of e-tender: the tender shall be submitted on line within upto 6.00 pm.

Similar documents
INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25

Date of Start and downloading the tender 12 sep 2018

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

No.PRS/R39/2015 Date: 17 August 2015

Department of Biochemistry University of Lucknow Lucknow

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

NATIONAL BANKING GROUP WEST-1

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

INVITATION FOR QUOTATION. TEQIP-II/2014/CG1G02/Shopping/50

TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONE UNDER

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

NanoReady. Micro UV-Vis Spectrophotometer

LIFE INSURANCE CORPORATION OF INDIA DIVISIONAL OFFICE 16/275, CIVIL LINES, KANPUR

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

Purchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems

STAR HOUSE BANK OF INDIA NATIONAL BANKING GROUP NORTH-I H-2 CONNAUGHT CIRCUS Middle/Outer Circle, Phone No

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI


INDUSTRIAL EXTENSION BUREAU

REQUEST FOR PROPOSAL FOR SUPPLY & INSTALLATION OF Air Conditioners

Queries raised by the representatives. 4 Sl. No.( iv) 31 Refer Sl. No. 2 It should be Windows 10 professional as it is the latest one

incubator, the best in its class

Recirculating Coolers

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN KARNATAKA & ANDHRA PRADESH ZONE

The following are the terms and conditions for the firms for submission of bids:


TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

MANUFACTURERS OF: INSTRUMENTS & SERVICES. Page:01

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

Ravi Malik General Manager

: 1.5kw/AC220V.50Hz (AC110V 60Hz) : 340*200*30mm (3piece) 400*200*30mm (3 piece)

Incubators. with BioCote antimicrobial protection

OFFICE OF THE DEAN FACULTY OF AGRICULTURE:: AAU :: JORHAT NOTICE INVITING QUOTATION

TENDER FOR EMPANELMENT OF VENDORS

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

NOTICE INVITING TENDER

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Operation Manual. (Version 1.5.1)

TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.

Weighing Balances. Hot Plate. Laboratory Oven. Muffle Furnace. Loss On Heating Oven COMMERCIAL EQUIPMENTS. General / Special Purpose Equipment

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

FLX380-30x FlexTester OTDR

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

BlueSpin Magnetic Hotplate Stirrer

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

Refrigerated Incubators / Environmental Testing Chambers

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

UCO BANK INDEX S.N. PARTICULARS PAGE NO. 1 INVITATION FOR TENDER OFFERS INSTRUCTIONS TO BIDDERS AND GENERAL TERMS & CONDITIONS 4-5

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

BATHS STIRRERS HOTPLATES HEATING MANTLES HOTPLATES

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES HOTPLATES

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

NEW products for 2012

Controlled Environment Equipment Solutions for the Lab

Portable central unit for several parameters

Specification of (COC) Automatic Open Cup Flash Point Tester with accessories

Detail Notice Inviting Expression of Interest for Survey & Fire Safety Audit

Protect your research

BLOOD BANKING AIISHIL" BLOOD BANK FREEZERS :

EasyLog Data Logger Series

CO2 Incubators The Complete Line

TORREY PINES SCIENTIFIC, INC.

Popular Science Apparatus Workshops Private Limited

Relationship beyond banking

FPD - Flame Photometric Detector

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

s ter k Hea y Bloc Dr

KAIGA GENERATING STATION

Nexera-i Specifications Prominence-i Specifications

Process Gas Chromatograph

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00


AZTECA A LITRE STERILISER

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES LOCATED IN DISTRICTS OF MAHARASHTRA :

Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units)

TENDER DOCUMENT FOR RATE CONTRACT FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Tender Enquiry No: BCL/PUR/MNG-PD/Fire Extinguisher/CW/18 Dated: Due date : M/s

Dry Bath Heating Systems

Alpha Engineering Company

Thermostats designed

LYODEL FREEZE DRYING SYSTEMS

EasyLog Data Logger Series

Material Description Quantity UOM

Transcription:

Bidhan Chandra Krishi Viswavidyalaya Regional Research Sub-Station, Chakdaha Uttar Panchpota, P.O. : Chakdaha, Pin-74 222 Dist.: Nadia, West Bengal 905339686(M) E-mail : sukanta.agron@rediffmail.com Dr. Sukanta Pal Professor in Agronomy & In-Charge Ref. No. RRSS/CH-8/ RIDF Dated : 4.03.208 Ref. e- Tender ID: 208_BCKV_63644_ Notice Inviting e- Tender Principal Investigator, Promotion of improved technology...reference to High yielding and Hybrid Rice Project -- RIDF, is inviting e-tender from competent and bonafide vendors/ parties/ distributors/ dealers/agents/ manufacturers having registration of GST for supply of following item to University within 23.03.208 upto 6.00 pm as per specifications appended below. i) Preparation of bids: the tender should be submitted under two bid system (i.e. technical and financial bid) with validity for a period of 2 (two) months. ii) Submission of e-tender: the tender shall be submitted on line within 23.03.208 upto 6.00 pm. iii) Technical bids will be evaluated by the PI and the Co PIs of the project and the financial bids will be opened of those bidders who qualified for technical bids. iv) Price: The price Equipments should be quoted in INR & net per unit (including taxes and duties, etc). bidders must stipulates the delivery period of the same. v) EMD: Vendors are required to pay the requisite amount of Rs.5000 (Rupees five thousand) only as EMD draft as specified against their quotation. Scanned copy of the demand draft must be uploaded as supporting document during submission of e-tender. Without EMD quotations bids will not be considered for technical of financial comparison. Draft must be in favour of Bidhan Chandra Krishi Viswavidyalaya payable at Kalyani (IFSC: SBIN000082). EMD exemption certificate must be attached, if any. vi) Supporting documents: a) Bid papers should accompany authorization certificate from original manufacturer, trade license, GST registration, etc. b) Scanned copy (self attested) of the original supporting document in favour of the specification claim for each items must have to be uploaded separately c) User list along with certificate from reputed users also need to be uploaded d) Scanned copy of supporting document of assured after sale service in Eastern India needs to be uploaded e) Price bid of the vendors will be compared only if technical specificity as appended against the item is fulfilled. The Viswavidyalaya reserves the right to accept or reject any tender without showing reason. Prof. Sukanta Pal RIDF, RRSS Chakdaha, BCKV-74222

Specification of the Item S. No Instrument Specifications Quantity. BOD Incubator Capacity 200 l 2. Digital ph meter Range 0-4 ph within accuracy of ±0.05 ph, complete with combination electrode 3. Electronic Weighing balance Weighing capacity upto 0 gm and precision upto 4 digits 4. Seed germinator (Single 5-60 0 C, 70 x 550 x 875 mm (280 l) chamber) 6. Double Distillation unit BOROSIL made 2 l/ hr capacity 7. Portable Heat Sealer - 8. Vernier Caliper Digital Measurement: 0. mm to 0 cm, Weight less than 200g, data storage card system 9. Digital refracto meter Refractive index (nd) :.32422 to.58000 Brix : 0.000 to 00.000% (5-75 0 C ATC) 0. Digital pocket scale 500 g -0.0 g. Portable vacume emasculator for rice Portable/ stationary Vaccum operated rice emasculator 2. Magnetic Hotplate Stirrers LED display for precise monitoring of temperature t A wide speed range of 0 to 500rpm t Max. Heating plate temperature 550 C t External temperature control is possible by connecting the temperature sensor(pt 000) with accuracy at ±0.2 C t The HOT warning will flash when the work plate temperature is above 50 C even the hotplate is turned off 3. Photoelectric Colorimeter Wave length range: 400-700 nm with 8 optical filters Filters peak wavelength: 420 nm, 440 nm, 490 nm, 520 nm, 540 nm, 570 nm, 600 nm, 700 nm Measuring Mode: % T, Abs, Conc & K factor Photometric Resolution: 0. % T, 0.00 Abs up to.999 Abs (O.D.) Display: 2 line 6 character LCD K factor range: 0 to 999 Concentration: 0 to 2 times the absorbance Sample Volume: ml in 4 ml test tube

Source: White LED Detector: Hermetically sealed photodiode Printer port: Epson compatible 80 column D.M. Printer Accessories: Four test tubes, two glass cuvettes 4. Water Bath Temperature Range: -20 to 00 C Bath Volume: 5 Lit Heater Capacity: 2000 watts Cooling Capacity @ 20 o C: 300 watts Pump Type: force Flow Rate max: 2 Lit / min Pump Pressure: 300 mbar Bath opening ( w x d x h): 3 x 2 x 5 cms Overall dimensions ( w x d x h): 25 x 45 x 62.5 cms Supply voltage: 230 / 50 Volts / Hz Recommended bath liquid 5 to 40 C -- Distilled Water 20 to 40 C -- Water with Antifreeze In applications below 5 C the water has to be mixed with an antifreeze. In doing so, the amountof antifreeze added should cover a temperature range 5 C lower (but max 20 C) than theoperating temperature of the particular application. This will prevent the water from gelling(freezing) in the area of the evaporating coil the surface area of which is much colder than the working temperature. An excess of antifreeze deteriorates the temperature accuracy due to itshigh viscosity. Filling with heat transfer liquid: Filling level of the interior bath: max. up to 2.0 cm below the cover plate, When working with water or water with antifreeze or with oil below ambient temperature: The filling level should be 2 cm below the deck plate. 5. Cooling Centrifuge 6. Hand Held photosynthetic system Main Unit Main Unit: On board IRGA for CO2 Analysis, H 2 O Analysis with humidity sensor capacitor, Flow Control, Pump, Display and Key Board,

Leaf Chamber attachment ports and Battery. Display: LCD 40 x 6 characters or 320 x 64 pixel Data Storage: 4 MB Internal FLASH RAM Data Output: USB Flow Rate: 00 ~ 000 cm2 / min Operating Temperature: 0-45 C Operating RH: 0-90% noncondensing Power Supply: 7.2 VDC, 4400 mah for 5 hours continuous use, extended hours of use with additional batteries. AC Adapter / Battery Charger supplied. Weight:.5 Kg (3 Lbs) with Battery Dimensions: 44 cm x 5.5 cm x 5 cm CO2 Analyzer Sensor: Low power Non-Dispersive Infrared Gas Analyzer Chopping Frequency: Hz Sensors Response Time: 35 seconds Source Life: 5,000 hours Measuring Range: 0 to 2000 ppm (Standard) - 0 to 3000 ppm (Optional) Resolution: 0.ppm Repeatability: ±0. ppm (short term) Accuracy: < ± 2% up to 2000 ppm Sample Cell: 00 mm x 0.2 mm (3.94 L x 0.40 Dia) H 2 O Analyzer Sensor Type: Humidity Sensitive Capacitor Stability: Stable Analyzer for accurate H20 measurements

Measuring Range: 0 to 00% Resolution: 0.% Accuracy: ±2% at 0% RH, ±3.5% at 95% RH PAR Measurement Sensor Type: Filtered GaAsP - Photodiode Measuring Range: 0 ~ 2500 µmol m-2s- Accuracy: ±5 µmol 0-2500 µmol / m2 / sec Chamber Measurement Temperature 7. Autoclave Vertical Fully Automatic Digital Sensor Type: Thermocouple Display: LCD 40x6 characters 320x64 pixel Measuring Range: -5 ~ 50 C Accuracy: ±0. C Leaf Temperature Measurement Sensor Type: Infrared Sensor Measuring Range: -0 ~ 50 C Accuracy: ±0.3 C Chamber Volume (L): 50 Temperature Sterilization Temp. ( C): 0 to 23 Temperature Melting Temp. ( C): 60 to 00 Pressure Sterilization at 2º (kg/cm2):. to.2 Pressure Gauge range in analog (Mpa): - 0. to 0.6 Load per baskets (Kg): 0 Basket dimension (O x H) (mm): 380 x 80 Pro programs: Standard modes (Decontamination, Solids Sterilization, Liquids Sterilization, Melting): Program modes Door delivery and warranty + Maintenance for 5yrs

Optional Local make, Chamber Volume (L): 50 Temperature Sterilization Temp. ( C): 0 to 23 Temperature Melting Temp. ( C): 60 to 00 Pressure Sterilization at 2º (kg/cm2):. to.2 Pressure Gauge range in analog (Mpa): - 0. to 0.6 Door delivery and warranty + Maintenance for 5yrs 8. Oven Hot air oven ( size: 4 x 4 x4 ) Temp: ambient + 5 to 250C, accuracy +/- C, double wall.outer MS power coated inner SS, 3 side heating element, solid door with lock. size: 4 x 4 x4 inch, capacity : 45L, with timer : 0 24 Hrs, digital temperature indicator and controller and micro presser based PID controller 9. Air Drier All internal parts S.S 304 quality; Drying Chamber: Doubled walled construction with insulation in between; Outside and inside body fully welded; heating and air circulation system; Control panel with digital temperature indicator 20. Microprocessor- based Flame Photometer cum controller starter. For measurement of Sodium, Potassium and Calcium. Sensitivity: Na: 2ppm,K: ppm, ca: 30 ppm Range: Na: -00ppm, K: -00ppm, Ca: 5-00ppm, Accuracy and reproducibility:=2% 2. Digital Balance Capacity 00 kg & 60 kg (2 No.); Max Sensitivity figure/ division: 00mg(platform type)