Working towards a cleaner future. Andrews Water Heaters Product Guide. 9.5kW to 550kW

Similar documents
Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

FASTflo. Working towards a cleaner future

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

Sirius FS. Working towards a cleaner future

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Sirius WH. Working towards a cleaner future

This manual must be kept with the appliance

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Copper-Fin GAS-FIRED WATER HEATERS

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

LBF RANGE BALANCED FLUED WATER HEATERS

SOLAR HEATING SYSTEMS

Solar thermal domestic hot water system

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Light commercial products. High output boilers Cascade systems

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

GHP AWO 38 Technical overview

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

Residential Heating Boilers

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

the electric heating company ELECTRIC BOILER HANDBOOK

Stored Water District Heating Interface Units. Heat Interface Units

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

New Zealand Sales Hotline: Sales Fax:

1 VICTRIX ZEUS Superior kw I features

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Super high efficiency heating and hot water boilers for every type of home and commercial property.

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

ENERGY TOP. Condensing boiler solutions

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

Saving energy comes naturally to us.

Copper-Fin GAS-FIRED BOILERS

For latest prices and delivery to your door visit MyTub Ltd

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

Broag Pressurisation equipment

SGE Condensing Gas - Solar Water Heater

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

RAYPAK HOT WATER & HEATING

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Biomass. Biomass solid fuel boiler range

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

SPECIFICATIONS - NIKE

HOT WATER SYSTEMS.

Efficient heating that won t cost the earth

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

RAYPAK HOT WATER & HEATING

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Power X High Power Condensing Wall-Hung Boilers

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Pressurisation units & expansion vessels

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

BFC Cyclone Condensing Glass-Lined Water Heater

CP+ Gas & Oil Cabinet Heater Range

Compact HRE Boiler Range. The smart choice for heating and hot water

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

WOLF GAS CONDENSING BOILERS COMFORTLINE

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

maximise the sun s energy with warmflow solar Warmflow Solar

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Series 1000 & Storage Water Heaters

Worcester GB162 wall mounted gas-fired condensing boiler series

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

S-AF Floor Standing Condensing Boiler kW

DOMESTIC BOILER RANGE & ACCESSORIES.

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

Knight & Charger Water Heaters

Transcription:

Andrews Water Heaters Product Guide The UK s most comprehensive range of Direct Fired Water Heaters 9.5kW to 550kW MAXXflo NEOflo ECOflo CSC Balanced Flue RSC Balanced Flue RFF Fan Flued Standard Range HIflo Oil-Fired FASTflo Plus FASTflo WH42 & WH56 SUPAflo SOLARflo AMBIflo ST Water Storage Vessels Mini-Plate Heat Exchanger Working towards a cleaner future

Contents MAXXflo 4 NEOflo 5 ECOflo 6 CSC Balanced Flue 7 RSC Balanced Flue 8 RFF Fan Flued 9 Standard Range 10 HIflo 11 Oil-Fired 12 FASTflo Plus 13 FASTflo WH42 & WH56 14 SUPAflo 15 SOLARflo 16 AMBIflo 17 ST Water Storage Vessels 18 Mini-Plate Heat Exchanger 18

Why Andrews Water Heaters? 3 Andrews Water Heaters, part of Baxi Commercial Division, is the UK s market leader for the supply of high efficiency direct gas-fired commercial water heaters, having the broadest portfolio of products and the largest selection of models in the condensing water heating sector alone. Established in 1976, Andrews Water Heaters remains the No. 1 provider of cost effective water heating solutions in a wide variety of multiple large residential, commercial and industrial properties. The full range of water heaters comprises of twelve models with recovery rates from 178 litres per hour to 9,200 litres per hour, ranging from 9.5 kw to 550 kw. These models offer different types of water heater options, from standard atmospheric to fully premix condensing, with flue options such as open flue, fan assisted, balanced flue and room sealed available. The basic design principles of these units offer high energy efficient operation, which has been successfully exploited in a number of award winning energy conservation projects (please see the Andrews Water Heaters website for full details and numerous case studies). These principles have been further developed to meet changing environmental concerns and legislation. All models carry the European Standards EC mark and the Queen s Award winning MAXXflo is included in the Government s ECA scheme, as well as the NEOflo, ECOflo and SUPAflo. Full details of our Size IT Guide, please visit our website, www.andrewswaterheaters.co.uk. Andrews Water Heaters also offer a complete range of LZC solutions, including solar thermal packages and air source heat pumps, which can be utilised alongside high efficiency water heaters to minimise energy use and significantly reduce carbon emissions within commercial buildings. For further details on all Baxi Commercial Divisions low to zero carbon range please consult the LZC Technology Guide available from the website. Sales: 0845 070 1056 Technical: 0845 070 1057 www.andrewswaterheaters.co.uk

4 High Efficiency Condensing Stainless Steel Storage Water Heaters MAXXflo MAXXflo Condensing Range 30kW to 120kW (450l/h to 1920 l/h recovery rate therough 50ºC rise) Eight models, ranging from 30kW to 120kW heat input Integral 200 or 300 litre stainless steel tank Condensing, 98% gross, 109% net efficiency Pre-mix fully modulating gas burner(s) Inbuilt anti-legionella function Natural Gas or LPG Low NOx pre-mix power burner Ultra low noise level and emissions Concentric or conventional flue design BMS interface control Winner of the Queen s Award for Enterprise in Innovation, 2007 WRAS approved Energy Technology Listed (ECA) Full unvented mains feed kits for all models Additional HWST 200 and 300 litre stainless steel storage tanks Additional concentric flue components Model Reference CWH 30/200 60/200 90/200 120/200 30/300 60/300 90/300 120/300 Input gross Hs min/max kw 6.7 31.1 13.4 62.2 20.1 93.3 26.8-124.4 Input nett Hi min/max kw 6.0 28.0 12.0 56.0 18.0-84.0 24.0-112.0 Output (tank set point = 60 C) min/max kw 6.5 30.5 13.0 61.0 19.5-91.6 26.0-122.1 Natural Gas, G20 Gas Consumption m 3 /h 2.96 5.93 8.89 11.85 Minimum Dynamic Gas Supply Pressure mbar 20 20 20 20 Propane, G31 Gas Consumption kg/h 2.18 4.35 6.53 8.71 Minimum Dynamic Gas Supply Pressure mbar 37 37 37 37 Efficiency (gross) % 98 98 98 98 Efficiency (nett) % 109 109 109 109 Standby Heat Loss Mj per month 780 780 780 780 NOx level @ 0% O2 ppm 25 25 25 25 NOx level @ 0% O2 mg/kwh 44 44 44 44 Noise level dba 51 51 51 51 Ionisation current max µa 6.0 6.0 6.0 6.0 Ionisation current min µa 4.0 4.0 4.0 4.0 HSI resistance kω 1.0 1.4 1.0 1.4 1.0 1.4 1.0 1.4 Max recovery thru 50 C ltrs/h 480 960 1440 1920 Max recovery thru 56 C ltrs/h 429 856 1284 1712 Flue size (concentric) Internal/External mm 80/125 80/125 130/200 130/200 Flue Size (conventional) mm 80 80 130 130 Max flue run concentric m 14 12 14 14 Max flue run conventional m 50 20 50 40 Max flue static pressure Pa 140 140 140 140 Inlet/Outlet connections BSP 1½ 1½ 1½ 1½ Return connection BSP 1 1 1 1 Nominal operating water pressure bar 3.5 3.5 3.5 3.5 Maximum water pressure bar 6.0 6.0 6.0 6.0 Minimum water pressure bar 1.0 1.0 1.0 1.0 Gas connection (gas cock supplied) BSP ¾ ¾ ¾ ¾ Electrical supply V/Hz 230/50 230/50 230/50 230/50 Power consumption W 170 340 510 680 Depth mm 900 900 900 900 Width mm 602 602 602 602 Height (200 litre) mm 1528 1528 1528 1528 Height (300 litre) mm 1952 1952 1952 1952 Weight empty (200 litre) kg 155 170 185 200 Weight empty (300 litre) kg 165 180 195 210 Weight full (200 litre) kg 355 370 385 400 Weight full (300 litre) kg 465 480 495 513 Noise level measured at 2m from flue terminal Reduce flue length by 1.2m for 90 bend, 0.7m for 45 bend and 1.5m for condensate trap Reduce flue length by 4m for 90 bend, 2m for 45 bend and 4m for condensate trap

NEOflo Condensing Range 25kW (430 l/hr recovery rate through 50ºC rise) Fully condensing 25kW heat input Fully insulated 200, 300 or 400 litre, stainless steel storage vessel Ultra low NOx and CO 2 emissions Pre-mix, non-modulating burner Factory fitted T/P valve Auto Ignition System Digital temperature display Integrated diagnostic history Suitable for vented or unvented system Suitable for low water pressure (0.2 bar) operation Supplied for Natural Gas Tank inspection hatch Low noise level (50d BA) Concentric or conventional flue design BMS interface control WRAS approved Energy Technology Listed (ECA) Full unvented mains feed kits for all models Additional water storage vessels Additional concentric components Model Reference SC25/200 SC25/300 SC25/400 Input gross Hs kw 26.3 26.3 26.3 Input net Hi kw 23.7 23.7 23.7 Nominal output kw 25 25 25 Natural Gas, G20 Gas consumption m 3 /h 2.4 2.4 2.4 Min. Dynamic Gas supply pressure mbar 20 20 20 Efficiency (gross) % 94 94 94 Efficiency (net) % 105 105 105 Maximum flue gas temperature ºC 75 75 75 Nominal flue temperature ºC 45 45 4 Max flue static pressure Pa 120 120 120 Flue Gas volume m 3 /h 37 37 37 CO 2 % 9.2 9.2 9.2 NOx level @ 0% 0 2 ppm 25 25 25 NOx level @ 0% 0 2 mg/kwh 44 44 44 NOx class 5 5 5 Noise level dba 50 50 50 Standby heat loss MJ per month 780 780 780 Ionisation current max µa 30 30 30 Ionisation current min µa 5 5 5 Max water temperature ºC 70 70 70 Max recovery thru 50ºC l/h 430 430 430 Max. recovery thru 56ºC rise l/h 380 380 380 Time to recover tank through 50ºC rise 29 44 59 Flue size (concentric) mm 80/125 80/125 80/125 Flue size (conventional) mm 80 80 80 Permitted flue system B23, C13 & C33 B23, C13 & C33 B23, C13 & C33 Air intake size mm 80 80 80 Max flue run (concentric) m 20 20 20 Max flue run (conventional) m 40 40 40 Inlet/outlet water connections G 3 4"M G 3 4"M G 3 4"M Secondary return & drain connection mm 22 22 22 Gas connection mm 22 22 22 Condensate connection mm 40 40 40 Condense rate l/h 2 2 2 Temperature & pressure valve size 3 4" Temperature & pressure relief valve rating 7 bar/95ºc 7 bar/95ºc 7 bar/95ºc Nominal operating water pressure bar 3.5 3.5 3.5 Maximum water pressure bar 6 6 6 Nominal operating water pressure on a U/V system bar 3.5 3.5 3.5 Minimum water pressure bar 0.2 0.2 0.2 Electrical supply V 230 230 230 Power consumption W 130 130 130 Fuse rate A 3 3 3 Protection rating IP20 IP20 IP20 Weight empty kg 105 137 153 Weight full kg 305 437 553 Heater depth mm 600 730 730 Heater width mm 600 730 730 Heater height mm 1570 1590 1900 Service clearance front mm 800 800 800 Service clearance side mm 100 100 100 Service clearance above mm 300 300 300 5 NEOflo High Efficiency Condensing Stainless Steel Storage Water Heaters

6 High Efficiency Condensing Storage Water Heaters ECOflo ECOflo Condensing Range 36kW to 118.7kW (600 l/hr to 1900 l/hr recovery rate through 50ºC rise) Eight models, ranging from 36kW to 118.7kW heat input 230 or 380 litre storage capacity available Fully condensing with efficiencies up to 98% Low NOx pre-mix power burner Vitraglas lined storage tank Factory installed Hydrojet Sediment Reduction System Natural Gas or LPG Approved for vented and unvented system applications Full Auto ignition Factory fitted Correx powered Anodes Vertical or horizontal flue kit and terminal available Inspection door fitted to all models Supplied with gas cock and drain cock WRAS approved Energy Technology Listed (ECA) Full unvented mains feed kit for all models Additional flue components available Additional ST storage vessels available, (ST66, ST100 and ST166) Conventional flue option (maximum 32 metres) Full BMS compatability standard issue Model reference Natural Gas EC230/600 EC230/700 EC230/960 EC380/740 EC380/980 EC380/1220 EC380/1400 EC380/1900 Heat input (gross, G20) kw 36.6 43.9 58.3 43.9 58.3 73.2 85 118.7 Heat output kw 35.1 41.3 54.2 43.0 57.1 71.0 79.1 117.2 Natural Gas, category I2H m 3 /h Gas consumption G20 3.41 4.09 5.43 4.09 5.43 6.82 7.92 11.33 Supply pressure mbar 20 20 20 20 20 20 20 20 Gross thermal efficiency % 96 94 93 98 98 97 93 94 Model reference Propane LEC230/600 LEC230/700 LEC230/960 LEC380/740 LEC380/980 LEC380/1220 LEC380/1400 LEC380/1900 Heat input (gross, G31) kw 36.6 43.9 58.3 43.9 58.3 73.2 85 117.2 Heat output kw 35.1 41.3 54.2 43.0 57.1 71.0 79.1 111.2 Propane Gas, category I3P m 3 /h Gas consumption G31 1.39 1.67 2.22 1.67 2.22 2.78 3.12 4.46 Supply pressure mbar 37 37 37 37 37 37 37 37 Gross thermal efficiency % 96 94 93 98 98 97 96 94 Technical details Natural Gas and Propane models N0x level ppm 25 25 25 25 25 25 25 25 mg/kwh 44 44 44 44 44 44 44 44 Noise level (a) dba 51 51 51 51 51 51 51 51 Standby heat loss Mj/month 626 626 626 626 793 793 793 817 Recovery rate/hour thru 50 C litres 600 700 960 740 980 1220 1400 1900 Storage recovery time @ 50 C rise mins 23 20 14 31 23 19 16 12 Flue size (concentric) mm 100/150 100/150 100/150 100/150 100/150 100/150 100/150 100/150 Maximum flue run (concentric (b) metres 16 16 16 16 16 16 16 16 Maximum flue run (conventional) 32 metres for all models Cold inlet water connection BSP 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" Hot outlet water connection BSP 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" 1 1 2" Drain port connection BSP 3 4" Secondary return connection BSP 3 4" Operating pressure (unvented) bar 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 Maximum working pressure (vented) bar 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 Maximum test pressure bar 20.7 20.7 20.7 20.7 20.7 20.7 20.7 20.7 Minimum water pressure bar 1 1 1 1 1 1 1 1 Gas connection dia. BSP 3 4"BSP 3 4" 1" Electrical supply 230v/50Hz 230v/50Hz 230v/50Hz 230v/50Hz 230v/50Hz 230v/50Hz 230v/50Hz 230v/50Hz Fuse amp 5 5 5 5 5 5 5 5 Power consumption W 120 120 120 120 120 120 120 120 Storage ltr 230 230 230 380 380 380 380 380 Shipping weight empty kg 259 259 259 408 408 408 408 408 Weight full kg 450 450 450 760 760 760 760 760 Shipping dimension depth mm 889 889 889 889 889 889 889 889 Shipping dimension width mm 819 819 819 819 819 819 819 819 Shipping dimension height mm 1664 1664 1664 2197 2197 2197 2197 2197 Height to lid mm 1448 1448 1448 1972 1972 1972 1972 1972 Plinth minimum mm 150 150 150 150 150 150 150 150 Diameter mm 718 718 718 718 718 718 718 718 Minimum headroom service clearance mm 450 450 450 450 450 450 450 450 (a) Noise level measured at 2m from flue terminal (b) Reduce flue length by 1.2m for 90º bend, 0.7m for 45º bend and 1.5m for condense trap

CSC Balanced Flue 44kW to 106kW (600 l/hr to 1445 l/hr recovery rate through 56ºC rise) Four models, ranging from 44kW to 106kW heat input Natural Gas or LPG Approved for vented and unvented system applications Fully auto ignition with BMS interface Honeywell control platform Vertical or horizontal flue kit and terminal available Inspection door fitted to all models Vitraglas lined storage tank Factory installed Hydrojet Sediment Reduction System Supplied with gas cock and drain cock Correx powered Anode Full unvented mains feed kit for all models Additional flue components available. Additional ST storage vessels available, (ST66, ST100 and ST166) 7 CSC Balanced Flue Andrews Model No. CSC 39 CSC 59* CSC 78* CSC 93* SI Metric SI Metric SI Metric SI Metric Storage Capacity litres 276 276 276 350 Recovery Rate/Hr @ 56ºC/100ºF Rise ltrs/hr 600 922 1213 1445 Heat Input kw 44.0 66.0 88.0 106.0 Flue Diameter mm 100/150 100/150 130/200 130/200 Cold Feed Connection Rp1 1 2 Rp1 1 2 Rp1 1 2 Rp1 1 2 Hot Water Connection Rp1 1 2 Rp1 1 2 Rp1 1 2 Rp1 1 2 Drain Port Size R 3 4 R 3 4 R 3 4 R 3 4 Gas Connection Rp 3 4 Rp 3 4 Rp 3 4 Rp 3 4 Electrical Supply 220/240V 50Hz, Fuse 5Amp, power consumption 236W Diameter mm 720 720 720 720 Height to Flue Centre* mm 2060 2060 1980 2217 Weight Empty kg 340 340 345 381 Weight Full kg 636 636 641 727 * Based on horizontal flue option

8 RSC Balanced Flue RSC Balanced Flue 9.5kW & 10.5kW (127 l/hr to 145 l/hr recovery rate through 56ºC rise*) Two models, ranging from 9.5kW to 10.5kW heat input Natural Gas only Vented and unvented system applications Vertical or horizontal flue kit and terminal available Factory installed Hydrojet Sediment Reduction System Vitraglas lined storage tank Supplied with gas cock and drain cock Correx powered Anode Full unvented mains feed kit for all models Additional flue components available. Additional ST storage vessels available, (ST66, ST100 and ST166) Automatic ignition BMS compatible Andrews Model No. RSC 150 RSC 190 SI Metric SI Metric Storage Capacity litres 150 190 Recovery Rate/Hr @ 56ºC/100ºF Rise ltrs/hr 127 145 Flue Diameter mm 80/125 80/125 Cold Feed Connection Rp 3 4 Rp 3 4P Hot Water Connection Rp 3 4 Rp 3 4 Drain Port Size Rp 3 4 Rp 3 4 Gas Connection Rp 1 2 Rp 1 2 Electrical Supply (Auto-Ignition option) 230V/5Amp 230V/5Amp Heat Input kw 9.5 10.5 Diameter mm 508 508 Height to Flue Centre* mm 2118 2398 Weight Empty kg 66 74 Weight Full kg 216 264 * Based on horizontal flue option

RFF Fan Flued 19.5kW & 23kW (232 l/hr to 272 l/hr recovery rate through 56ºC rise) Two models, ranging from 19.5kW to 23kW heat input Natural Gas only Factory fitted flue fan linked to main burner Horizontal or vertical flue kits (80mm diameter) included Supplied with draught diverter, gas cock and water drain valve Factory installed Hydrojet Sediment Reduction System Automatic ignition as standard Vitraglas lined storage tank Correx powered Anode Additional flue components available Full unvented mains feed kit for all models Additional ST storage vessel available, (ST66, ST100 and ST166) 9 RFF Fanned Flue Andrews Model No. RFF190 RFF280 SI Metric SI Metric Storage Capacity litres 190 280 Recovery Rate/Hr @ 56ºC/100ºF Rise ltrs/hr 232 272 Heat Input kw 19.5 23.0 Flue Diameter mm 80 80 Cold Feed Connection 3 4 in BSP 3 4 in BSP Hot Water Connection 3 4 in BSP 3 4 in BSP Drain Port Size 3 4 in BSP 3 4 in BSP Gas Connection 1 2 in BSP 1 2 in BSP Electricity Supply 220/240V 50 Hz, Fuse 5 Amp, power consumption 236 W Diameter mm 559 660 Height to Flue Centre* mm 1867 1943 Weight Empty kg 75 132 Weight Full kg `` 273 418 * Based on horizontal flue option Each water heater is specified with the following horizontal or vertical flue components. Horizontal Models Flue adaptor, 90º elbow, 2x1000mm lengths of flue and wall outlet complete with wallplates. Additional 90º, 45º bends and 1000mm flue lengths are available as optional extras (see price list) enabling maximum horizontal flue runs up to 7000mm (RFF190) and 4000mm (RFF280). Decrease the flue run by 1000mm for every 90º bend and 500mm for every 45º bend installed. Vertical Models Flue adaptor 1x1000mm and 2x500mm lengths of flue and a vertical terminal. Additional flue components are available as above with maximum vertical flue of 8000mm (RFF190) and 5000mm (RFF280). Decrease the flue height by 1000mm for every 90º bend and 500mm for every 45º bend installed. Before designing the installation contact the Andrews Water Heaters sales office for an installation manual, or see our website.

10 Standard Range Atmospheric Range Standard Range 12kW to 26kW (142 l/hr to 316 l/hr recovery through 56ºC rise) Five models, ranging from 12kW to 26kW heat input Natural Gas or LPG Vented and unvented system applications Permanent pilot with piezo ignition as standard Supplied with draught diverter, gas cock and water drain valve Inspection door fitted to 63/62 and 84/87 models Vitraglas lined storage tank Correx powered anodes Fully automatic ignition Exhausto flue fan available for Auto Ignition models (63/62 and 84/87 only) Pilot monitoring kit for PP models Full unvented mains feed kit for all models Additional ST storage vessel available, (ST66, ST100 and ST166) Andrews Model No. 24/39 32/40 40/61 63/62 84/87 SI Metric SI Metric SI Metric SI Metric SI Metric Storage Capacity litres 109 145 182 286 382 Recovery Rate/Hr @ 56ºC/100ºF Rise ltrs/hr 142 146 220 227 316 Heat Input kw 12.0 12.5 19 19 26.0 Flue Diameter mm 100 100 100 125 125 Cold Feed Connection R1 R1 R1 R1 R1 1 4 Hot Water Connection R1 R1 R1 R1 R1 1 4 Drain Port Size R 3 4 R 3 4 R 3 4 R 3 4 R 3 4 Gas Connection Rp 1 2 Rp 1 2 Rp 1 2 Rp 1 2 Rp 1 2 Diameter mm 457 508 508 622 718 Height to Flue mm 1276 1327 1589 1669 1788 Weight Empty kg 43 57 65 110 181 Weight Full kg 151 202 247 396 562

HIflo Atmospheric Range 42.8kW to 139kW (517 l/hr to 1598 l/hr recovery rate through 56ºC rise) Six models, ranging from 42.8kW to 139kW heat input Natural Gas or LPG Vented and unvented system applications Permanent pilot with piezo ignition as standard Supplied with draught diverter, gas cock and water drain valve Inspection door fitted to all models Factory installed Hydrojet Sediment Reduction System Vitraglas lined storage tank Correx powered Anode Available with Auto Ignition for Natural Gas only, with full BMS interface Additional flue damper kit available for Auto Ignition models Exhausto flue fan available for Auto Ignition models Pilot monitoring kit for PP models. Full unvented mains feed kit for all models. Additional ST storage vessels available, (ST66, ST100 and ST166) Switching kit Pilot monitoring kit 11 Hiflo Andrews Model No. 32/143 65/173 81/264 62/341 54/418 54/440 SI Metric SI Metric SI Metric SI Metric SI Metric SI Metric Storage Capacity litres 145 295 368 282 245 245 Recovery Rate/Hr @ 56ºC/100ºF Rise ltrs/hr 517 629 959 1239 1520 1598 Heat Input kw 42.8 50.0 80.0 102.0 128.0 139.0 Flue Diameter mm 150 m 150 200 200 250 250 Cold Feed Connection R1 1 2 R1 1 2 R1 1 2 R1 1 2 R1 1 2 R1 1 2 Hot Water Connection R1 1 2 R1 1 2 R1 1 2 R1 1 2 R1 1 2 R1 1 2 Drain Port Size R 3 4 R 3 4 R 3 4 R 3 4 R 3 4 R 3 4 Gas Connection Rp 3 4 Rp 3 4 Rp 3 4 Rp 3 4 Rp 3 4 Rp 3 4 Diameter mm 711 711 711 711 711 711 Height to Flue Spigot mm 1343 1937 2208 1968 1934 1934 Weight Empty kg 190 200 289 257 269 269 Weight Full kg 335 495 656 538 514 514

12 Oil Fired Oil Fired 30.8kW to 184.6kW (390 l/hr to 2516 l/hr recovery rate through 56ºC rise) Six models, ranging from 30.8kW to 184.6kW heat input Gas, Oil or Kerosene Vented and unvented system applications Supplied with draught stabilizer and water drain valve Factory installed Hydrojet Sediment Reduction System Vitraglas lined storage tank Correx powered Anode kit Exhausto flue fan Full unvented mains feed kit for all models Additional ST storage vessels available, (ST66, ST100 and ST166) Model OFS25 OFS29 OFS63 OFS90 OFS108 OFS163 SI Metric SI Metric SI Metric SI Metric SI Metric SI Metric Storage capacity litres 192 265 146 146 378 306 Recovery through 56ºC l/hr 390 443 975 1398 1677 2516 Heat input kw 30.8 34.9 71.8 102.6 123.1 184.6 Heat output kw 25.2 28.6 63 90.3 108.3 162.5 kw Gross efficiency % 82 82 88 88 88 88 Fuel BS2869 Kerosene Class C2 or Gas Oil Class D Burner type (1) EOGB BTL4 EOGB BTL4 EOGB BTL6 EOGB BTL10 EOGB BTL10 EOGB BTL14 Flue diameter mm 150 150 200 200 200 200 Electrical supply Fuel consumption (2) Kerosene 28 sec Class C Fuel consumption Gas Oil 35 sec Class D 230 Volt 1 ph 50 Hz ltrs/h 3.2 3.7 7.5 10.8 12.9 19.4 ltrs/h 3.1 3.5 7.2 10.3 12.4 18.6 Cold inlet top 3 4"BSP (22 mm) 1"BSP (28 mm) 1 1 2"BSP (42 mm) Cold inlet front (3) 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) Cold inlet rear 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) 2"BSP (54 mm) 2"BSP (54 mm) Hot outlet top 3 4"BSP (22 mm) 1"BSP (28 mm) 1 1 2"BSP (42 mm) Hot outlet front 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) 1 1 2"BSP (42 mm) Hot outlet rear 1 1 2 "BSP (42 mm) 1 1 2"BSP (42mm) 2"BSP (54 mm) 2"BSP (54 mm) Drain port 3 4"BSP (22 mm) 3 4"BSP (22 mm) 3 4"BSP (22 mm) 3 4"BSP (22 mm) 3 4"BSP (22 mm) 3 4"BSP (22 mm) Max working pressure 150 psi 10.3 bar 150 psi 10.3 bar 150 psi 10.3 bar 150 psi 10.3 bar 150 psi 10.3 bar 150 psi 10.3 bar Max test pressure 300 psi 20.6 bar 300 psi 20.6 bar 300 psi 20.6 bar 300 psi 20.6 bar 300 psi 20.6 bar 300 psi 20.6 bar Weight empty inc. burner kg 118.5 143.5 195 195 345 395 Weight full inc. burner kg 309 406 340 340 722 699 Height to lid mm 1575 1626 1299 1299 1867 1867 Height to flue spigot mm 1632 1695 1337 1337 1905 1905 Width mm 521 610 719 719 813 813 Height to draught stabilizer mm 1949 2000 1739 1739 2307 2307 (1) Price includes EOGB BTL on/off type oil burner, water draw off cock, draught stabiliser and comprehensive installation manual. (2) The burner is supplied with a kerosene nozzle and a gas oil nozzle, correct one to be fitted on site. (3) Refer to specification sheet for full dimensions and further technical data and to installation manual for installation instructions.

FASTflo Plus Condensing 13 54kW Output (15 l/min flow rate through 56ºC rise) Fully condensing with efficiency of 103% net Heat input of 54kW Only Natural Gas Internal room sealed models Vertical or horizontal flue options Wall hung Remote control and display panel Factory fitted frost protection Condensate trap fitted as standard Modulating burner Low NOx technology Model WHC56 Heat input net kw 54.0kw Heat output net kw 55.8kw Water Connection Gas Connection Additional flue components available Storage vessel available, (ST66, ST100 and ST166) Full unvented mains feed kit Quick connect cord kit System control kit 3 4"BSP 3 4"BSP Efficiency % 103 Flow rate @ 25 C rise ltrs/min 15 Min flow rate ltrs/min 3.5 Flue Size Concentric mm 100 Fuse A 5 Width mm 465 Height mm 615 Depth mm 240 Weight kg 29 FASTflo Continuous Flow Condensing Wall Hung Balanced Flue Water Heater Note: Although the heaters operate at low water pressure, maximum performance is not attained unless the incoming pressure is 2 bar or more. On pumped circulation systems a minimum flow of 8 litres/min through each heater is required for optimum performance.

14 FASTflo WH42 & WH56 Continuous Flow Wall Hung range Balanced Flue Water Heaters FASTflo 49kW to 62kW (10.8 l/min to 15 l/min flow rate through 56ºC rise) Three models, ranging from 49kW to 62kW heat input Natural Gas or LPG Internal room sealed or external models available Vertical or horizontal flue options Wall hung Remote control and display panel Factory fitted frost protection Modulating burner Low NOx technology Additional flue components available Storage vessel available, (ST66, ST100 and ST166) Full unvented mains feed kit Quick connect cord kit System control kit Model (Natural Gas) WH42 WH56 WHX56 Model* (Propane) LWH42 LWH56 Heat input net kw 49.0 62.3 62.3 Heat output net kw 42.0 55.8 55.8 Gas rate natural m 3 /hr 5.1 6.5 6.5 Gas rate propane m 3 /hr 1.9 2.5 2.5 NOx emissions ppm 52 52 N/A NOx emissions mg/kwh 92 92 N/A NOx emissions (propane) ppm N/A 72 N/A NOx emissions (propane) mg/kwh N/A 128 N/A Noise Level db(a) 49 49 49 Water connection 3 4"BSP 3 4"BSP 3 4"BSP Gas connection (gas cock supplied) 3 4"BSP 3 4"BSP 3 4"BSP Max water pressure bar 10.0 10.0 10.0 Min water pressure** bar 1.0 1.0 1.0 Electric supply V 230 230 230 Frequency Hz 50 50 50 Fuse A 5 5 5 Max flow rate @25ºC rise ltrs/min 24 32 32 Min flow rate ltrs/min 3.5 3.5 3.5 Flue Type Concentric Concentric External 100mm 100mm No Flue required Width mm 450 450 450 Height mm 615 615 615 Depth mm 240 240 240 Weight kg 29 29 30 * L prefix propane models must be specified when ordering. ** Note: Although the heaters operate at low water pressure, maximum performance is not attained unless the incoming pressure is 2 bar or more. On pumped circulation systems a minimum flow of 8 litres/min through each heater is required for optimum performance.

SUPAflo SF60 Condensing Range 15 145kW to 550kW (2430 l/hr to 9230 l/hr through 50ºC rise) Seven models, ranging from 145kW to 550kW heat input Natural Gas or LPG Vented and unvented systems application Low NOx high efficiency burner Fully condensing, pre-mix modulating burner Fully modulating between 20% and 100% load Stainless steel headers and heat exchangers Room sealed as standard UPS bronze primary pump supplied WRAS approved Energy Technology Listed (ECA) Full unvented mains feed kit for all models Stainless steel buffer vessel available, (SFB300 and SFB500) ST Buffer vessels available, (ST66, ST100 and ST166) SUPAflo Model SF61 SF62 SF63 SF64 SF65 SF66 SF67 Input (Gross) kw 145 194 242 291 388 485 550 Nominal Output kw 142 190 237 285 380 475 539 Water Volume ltrs/h 27 31 35 61 68 75 82 Minimum Supply Gas Pressure mbar 20 20 20 20 20 20 20 Efficiency (nett) % 103.9 103.9 103.9 103.9 103.9 103.9 103.9 Maximum/Minimum Flue Gas Temperature C 56/30 56/30 56/30 56/30 56/30 56/30 56/30 Electricity Supply V 240V 1 Phase 240V 1 Phase 240V 1 Phase 240V 1 Phase 240V 1 Phase 415V 3 Phase 415V 3 Phase Max Water Temperature C 80 80 80 80 80 80 80 Max recovery thru 50 C ltrs/h 2430 3250 4050 4880 6510 8130 9230 Max recovery thru 56 C ltrs/h 2160 2900 3620 4350 l/h 5810 7260 8240 Flue Size mm 150 150 200 200 250 250 250 Inlet/Outlet water connections 2" 2" 2" DN65/PN16 DN65/PN16 DN65/PN16 DN65/PN16 Gas Connection R 3 4" R1" R1" R1" R1½" R1½" R1½" Maximum Water Pressure bar 6 6 6 6 6 6 6 Minimum Water Pressure bar 1 1 1 1 1 1 1 Nominal operating water pressure bar 3.5 3.5 3.5 3.5 3.5 3.5 3.5 Weighty Empty bar 295 345 400 465 535 590 650 Heater Depth mm 1105 1260 1470 1220 1435 1585 1735 Heater Width mm 670 670 670 770 770 770 770 Heater Height mm 1440 1440 1440 1440 1440 1440 1440

16 SOLARflo Solar Thermal Solutions Solar Thermal Solutions Glazed Flat Plate, Heat Pipes & Evacuated Tube Collectors SOLARflo Features Solar Collectors (Glazed flat plate) Glazed flat plate aluminium tray solar collector 2.55m 2 gross collector area 2.16m 2 collector absorber area High transmission efficiency (91%) High absorption efficiency (95%) Low emission loss (5%) Solar Key Mark Approved Solar Collectors (Evacuated Tubes) Direct Flow Evacuated Tube Technology 2.83m 2 (20 tube) and 4.25m 2 (30 tube) gross collector areas 2m 2 (20 tubes) and 3.02m 2 (30 tubes) collector absorber area High absorption efficiency (95%) Low emission loss (5%) Solar Key Mark Approved Solar Collectors (Heat Pipes) Dry Pocket Evacuated Tube Technology 2.84m 2 (20 tube) and 4.26m 2 (30 tube) gross collector areas 2m 2 (20 tubes) and 3.02m 2 (30 tubes) collector absorber area Inbuilt temperature limitation safety device Collector specifications High absorption efficiency (95%) Low emission loss (5%) Solar Key Mark Approved Cylinders 450 to 3000 litre single cylinder capacities Twin-coil and single coil pre-heat unvented hot water cylinders Non-corrosive duplex stainless steel water chamber for longer life Stainless steel indirect coil(s) Destratification and anti-legionella functionality as standard Pump Station Solar pump station c/w temperature gauges and pressure gauge, flushing and filling device and deaerator Control Unit Differential temperature control Variable set points to enable system optimisation Primary heating appliance control Anti-Legionella functionality Other equipment included Solar collector mounting accessories for pitched roof, flat roofs and fascia capability Cold water expansion kit Solar heat transfer expansion vessel with membrane temperature rating of 100 C Primary heating appliance (direct-fired water heater or commercial boiler) as an option Evacuated Tubes Evacuated Tubes Heat Pipes Heat Pipes Glazed Flat Plate Glazed Flat Plate DF100 2m 2 DF100 3m 2 HP200 2m 2 HP200 3m 2 SOL 250 SOL 250H Number of Tubes 20 30 20 30 Gross Area m 2 2.83 4.25 2.843 4.265 2.51 2.51 Absorber Area m 2 2 3.02 2.01 3.021 2.354 2.354 Aperture Area m 2 2.15 3.23 2.16 3.23 2.373 2.373 Collector fluid content litres 3.8 5.6 1.2 1.7 3.4 3.5 Absorption Efficiency % 95 95 95 95 95 95 Emission % 5 5 5 5 5 5 Collector efficiency at ambient temperature (0) (based on absorber area) 83 83.2 79.2 77.8 82.1 81.9 First order heat loss coefficient (a1) (W/m 2 K) (based on absorber area) 1.53 1.14 1.25 0.91 3.67 3.671 Second order heat loss coefficient (a2) (W/m 2 K) (based on absorber area) 0.0063 0.0144 0.0088 0.01 0.009 0.0129 Incident angle modifier (K50 longitudinal) 0.92 0.92 0.92 0.92 0.93 0.94 Stagnation temperature C 286 286 217 217 221 221 Anti stagnation feature operation temperature C NO NO 95 95 NO NO Maximum operating pressure bar 8 8 8 8 10 10 MCS approval number MCS BBA 0077 MCS BBA 0078 Peak kw output per collector (RHI purposes) 1.98 2.5 1.592 2.349 1.93 1.93 Minimum collector inclination 0 0 20 20 20 20 Maximum No of Collectors in Series 7 5 6 4 10 10 Height (portrait) mm 1996 1996 2005 2005 2.187 1.147 Width mm 1418 2127 1418 2127 1.147 2.187 Depth mm 97 97 97 97 87 87 Collector Weight (dry) kg 54.8 81.4 50 76 48 49

AMBIflo Air Source Heat Pump 16kW or 20kW Output 16kW or 20kW air source (air-to-water) heat pump 450 litre unvented, duplex stainless steel, indirect, single coil pre-heat cylinder (hot water applications) complete with cold feed kit including expansion vessel 450 litre buffer tank for space heating applications Single, fully contained, air source heat pump Weatherproof enclosure suitable for outdoor installations R407C is used as the refrigerant within a pre-charged sealed circuit Anti-vibration mountings included Siemens controls platform with Building Energy Management System (BEMS) interface Left hand or right hand hydraulic connections Multi unit installations possible with up to six heat pumps operating in cascade 17 AMBIflo Air Source Heat Pump Specification 16kW 20kW model model Output (A7, W35) kw 18.7 22.7 Output (A2, W35) kw 15.1 19.9 CoP(A7,W35 BSEN14511) 4.6 3.6 CoP(A2,W35 BSEN14511) 3.9 3.2 Maximum Power Input A 14.0 17.0 Starting current with Soft Starter A 36.0 40.0 Motor Current locked rotor A 74.0 99.0 Power Supply V-p-Hz 400-3-50 400-3-50 Protection A 20.0 20.0 Hot Water Exchanger Chrome Steel AISI 316, 1.4401 Hydraulic Connections Ø 1" 1 1 4" Nominal Water Flow l/h 1,461 1,754 Hydraulic Resistance kpa 5.5 3.7 Air Flow Rate m 3 /h 5,000 6,300 Refrigerant R407C R407C Noise Level at 10 metres db(a) 40.3 44.1 Height mm 1,675 1,695 Width mm 1,195 1,195 Depth mm 750 880 Weight of Refrigerant kg 3.7 5.4 Weight of Heat Pump kg 277 337

18 ST Water Storage Vessels ST Water Storage Vessels These ST storage vessels are of similar construction to the other storage water heaters but without a burner and heat exchanger. The ST storage vessels are to compliment the water heaters where extra storage is required to satisfy heavy peak demands. These are available in three sizes, ST66, ST100 and ST166. Technical Data Model ST66 ST100 ST166 SI Metric SI Metric SI Metric Storage Capacity litres 300 455 755 Flow Connection Rc2 Rc2 Rc2½ Inlet Connection Rc2 Rc2 Rc2½ Return Connection Rc2 Rc2 Rc2½ Thermostat Connection Rc¾ Rc¾ Rc¾ Weight Empty kg 95.2 141 245 Weight Full kg 395 594 998 Maximum Working Pressure bar 10.3 10.3 10.3 Maximum test Pressure bar 20.6 20.6 20.6 Height mm 1492 1588 1956 Diameter mm 610 mm 711 813 Magnesium anodes supplied as standard Correx Anode option available Mini-Plate Heat Exchanger Mini Plate Heat Exchanger When the heating demand is small but high volume hot water is required, the combination of an Andrews Mini-Plate and an Andrews water heater provides the complete solution. A plate heat exchanger, pumps and electrical control assembly neatly packaged inside a compact enclosure provide an add-on space heating function for Andrews water heaters. Specification Maximum capacity of heat exchanger* kw 23 Water connection heating side mm 22 Water connection, domestic side mm 15 Electrical supply Electrical load, pumps W 104 Electrical load, control panel W 20 *Dependant upon water temperatures 230V 1ph 50Hz TYPICAL SYSTEM LAYOUT 1. Cold feed (See Installation Manual) 2. Non return valve 3. Bronze domestic water pump 4. Plate heat exchanger 5. Heating pump 6. Expansion tank

ANDREWS LARGEST SOLAR THERMAL WATER HEATING SYSTEM In Andrews Water Heaters largest SOLARflo water heating installation, the Travelodge in Fulham has been equipped with 33 solar panels, three single coil pre-heat tanks and two ECOflo water heaters, which supply domestic hot water to the 74 rooms, each of which has an en suite bath or shower room. Developed by Lombard Asset Management (Bahamas) Limited, the four storey building includes ground floor retail accommodation, with the Travelodge located on three floors above. Renewable energy was a preheated by the solar solar controls, pump station, requirement of planning consent collectors, which are positioned expansion vessels, first fill of which would not have been to optimise their solar gain and heat transfer fluid and collector granted without a contribution of heat is transferred to the three mounting accessories. Matched 37,000 kw of energy produced 1250 litre single coil cylinders. equipment from a single source, from a solar DHW system. Since These in turn supply pre-heated together with the availability of at least 85-90% of the hotel s water to the two ECOflo technical advice throughout the rooms have been occupied 380/1400 water heaters, installation, is a particular benefit every night since it opened, an thereby considerably reducing of the Andrews Water Heaters efficient, reliable and costeffective source of hot water The ECOflo models installed service. the consumption of natural gas. product range and after sales was essential. each have a capacity of 380 The ECOflo high efficiency, The solar panels are located litres and a fast recovery rate gas-fired condensing water on the roof, whilst the water through 50ºC of 1400 litres heaters feature a low NOx premix power burner that is quiet in heaters, cylinders and other per hour. solar equipment are housed in a The SOLARflo water heating operation, and a high net mezzanine plant room above the package and ECOflo water efficiency of 109%. The units retail store on the ground floor. heaters were installed by MITIE incorporate Vitraglas silica Each of the 33 glazed flat plate Engineering Limited, who glass lined tanks which provide collectors has an area of 2.55 selected the SOLARflo and protection against the corrosive square metres, giving a total ECOflo equipment to meet both effect of hot water, guaranteeing collector area of 84.15 square end user requirements and metres. These solar collectors space availability in the plant provide 90.8% transmission room. In addition to the glazed maintenance free powered efficiency, 95% absorption flat plate solar collectors and anodes, which substantially efficiency and a low emission non-corrosive, stainless steel reduce service time and costs. loss of only 5%. Water is solar cylinders, the complete The option for these SOLARflo package also includes appliances to be flued either vertically or horizontally as room sealed balanced flue appliances greatly increases siting and installation flexibility. As with all Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Tel: Sales 0845 070 1056 Technical 0845 070 1057 Email: baxicommercial@baxigroup.com www.baxicommercial.co.uk Andrews water heaters, heat input and flow are carefully regulated to produce a closely controlled water temperature and a high temperature antilegionella program is incorporated as standard, essential for hotel hot water installations. Andrews Water Heaters is part of Baxi Commercial Division. 37,000kW of energy from renewable resources Compact appliances to fit in plant room Safe, reliable and costeffective hot water Fast recovery rate Two ECOflo 380/1400 gas-fired condensing storage water heaters SOLARflo solar thermal water heating system including: 33 glazed flat plate solar collectors Three single-coil pre-heat cylinders Solar controls unit, pump station, expansion vessels, first fill of heat transfer fluid and collector mounting accessories Brochure gallery 19 This page displays the latest printed and digital information to help you select the best high efficiency products and low carbon solutions when designing commercial heating projects. Available to you is an entire knowledge bank, just a click or telephone call away. So whatever your requirements, please telephone 0845 070 1055 to receive copies in the post or download from our website. Baxi Commercial Division Low /Zero Carbon Technology Guide The UK s most comprehensive range of low energy solutions Baxi Commercial Division Driving the Future Whether driven by environmental concern, legislative demands, reducing cost or conserving fuel supplies, the actions we need to take and the results we need to achieve are the same. The issue is sustainability, for the environment and for the industry. And the time for change is now. Paul Hardy, Managing Director, Baxi Commercial Division Potterton Commercial Commercial Boiler Guide 27 to 4000kW Condensing cast aluminium/silicon 30 to 300kW Condensing stainless steel 50 to 160kW Modular and prefabricated solutions 60 to 1150kW Heat Pumps 21.3 to 41.2kW Atmospheric cast iron 50 to 348kW Pressure jet steel 290 to 4000kW Heatboxes Heating and domestic hotwater interface units Pressure jet cast iron 27 to 729kW CONTENTS: Condensing oil 98 and 131kW Working towards a cleaner future 35 YEARS OF INNOVATION p2 THE JOURNEY TO A ONE STOP, HIGH EFFICIENCY SOLUTION p2 ONE STOP FOR LZC SOLUTIONS p4 BRINGING PARTIES TOGETHER p5 GRADUATE WINNER S AMERICAN EXPERIENCE p5 ROUND TABLE DISCUSSION p6 RAISING STANDARDS p6 THE FUTURE OF THE INDUSTRY IS IN THEIR HANDS p8 IS THE INDUSTRY READY? p9 A SHARED VISION p10 Working towards a cleaner future heating specialists NEW! Baxi Commercial Division Legislation Guide Andrews Water Heaters Product Guide The UK s most comprehensive range of Direct Fired Water Heaters 9.5kW to 550kW Solar SizeIt Available! Working towards a cleaner future Working towards a cleaner future SPRING 2013 Hot Topics New Training Facility New Products at Ecobuild Applying Technology Supplement including Biomass Community Challenge Oakham School Project B A X I C O M M E R C I A L D I V I S I O N www.baxicommercial.co.uk Wina mini ipad seepage14 Baxi Commercial Division, Wood Lane, Erdington, Birmingham B24 9QP Tel: 0845 070 1055 Fax: 0845 070 1059 Sales:0845 070 1056 Technical: 0845 070 1057 Service: 0845 070 1058 Baxi Commercial Division Case Study Fulham Travelodge a longer working life. Also standard are Correx Project Requirements: Solutions: Case Study Baxi Commercial Division FOCUS ON HOTELS Beacon Centre for the Blind, Wolverhampton HIGH EFFICIENCY SOLAR THERMAL SOLUTION FROM ANDREWS Andrews Water Heaters, part of Baxi Commercial Division, has supplied two SOLARflo water heating systems, along with Queen s Award winning MAXXflo condensing water heaters, for the new Beacon Centre for the Blind in Wolverhampton. The Centre, for people with sight loss, brings together services which were previously housed in eight separate buildings on the seven acre site. The new state-of-the-art facility comprises athree storey office block and a separate support area tothe residential block, which have both been designed to achieve an energy efficient solution which minimises CO 2 emissions. The whole building concept scheme with the twosolarflo systems wasspecified by Rediger Ltd., who are CIBSE registered LowCarbon Consultants. Aspokesman commented, We haveused the equipment in the pastand Andrewshave a good reputation in thisrespect. The system comes asacomplete package and the inbuiltcontrols provide all thatisnecessary for efficient operation. In addition, there were no problems tying in with the BMS. The SOLARflosystem serving the officeblock provides domestichot water to washroomfacilities and kitchenetteson each of three floors,atotal of24 wash hand basinsand fivesinks.inthe residential support building, the systemservesakitchen with four outlets, a bar with two sinks,ahairdresser swith four basins and two toiletareaswith a totalof eight wash hand basins. Both systems were designed and installed by WilliamDavis Ltd. and a spokesman commented, Everything went well from initial concept tocompletion of the project. The officeblock system comprises sixroof-mounted, Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Tel: Sales 0845070 1056 Technical08450701057 Email: baxicommercial@baxigroup.com www.baxicommercial.co.uk glazed flat platesolar collectors with atotal area of 15.6 square metres, a 900 litre twin-coil stainless steel cylinder and a MAXXfloCWH120/300 condensing storagewater heater. The MAXXflo, cylinder and other components of the solar packageare installed in the ground floor plant room, where the water heater isinstalled with a horizontal, balanced flue. The residentialsupport block has seven roof mounted solar collectorswith a total area of 18.5square metres. A700litre twin-coil cylinder, amaxxflo CWH60/300water heater, with vertical balanced flue, and the remainder of the solar package are also installed in aground floor plant room. Water ispreheated by the glazed flatplatesolar collectors, which have atransmission efficiency of 90.8%,an absorption efficiency of 95% and a lowemission lossof only 5%. Heatistransferred tothe twotwin coil cylinderswhich in turn pre-heat the supply to the MAXXflowater heaters, thereby considerably reducing consumption of natural gas. Offering an impressive operationalefficiency of109%, the MAXXfloisideal for buildings with a high demand for hot water. The fast recovery rate of thesewater heaters and their innovative design means that carbon footprint, NOx levels and runningcostsare kepttoa minimum. Heat inputand flow are carefully regulated to produce aclosely controlled water temperatureand ahigh temperature anti-legionella program isincorporated as standard. Project Requirements: Safe and reliable hot water High energy efficiency and low running costs Easy integration witha BMS Excellent recovery rates Solutions: One MAXXflo CWH120/300 direct-fired condensing storage water heater One MAXXflo CWH 60/300 direct-firedcondensing storage waterheater Two SOLARflo solar thermalwater heating systems including: 13 glazed flat plate solar collectors Two twin-coil pre-heat cylinders Two solar control units, pumpstation, expansion vessels, first fill of heat transfer fluid and collector mounting accessories SUPPORTING DISABILITY Case Study FOCUS ON Baxi Commercial Division WoodLane,Erdington,BirminghamB24 9QP Tel: Sales0845 0701056 Technical0845 070 1057 Email:baxicommercial@baxigroup.com www.baxicommercial.co.uk Baxi Commercial Division Blackburn Cathedral, Lancashire GREEN CATHEDRAL OPTS FOR MINI-CHP A mini-chp unit, generating 12.5kW of heat and 5.5kW of electrical power, is at the heart of a wide-ranging project to reduce the carbon footprint of Blackburn Cathedral Lancashire s largest place of worship. The Baxi-SenerTec UK G 5.5 Dachs unit is part ofthe 210,000 first phase of an energy reduction strategy for the 180-year-old Cathedral. Engineersdismantled the generate electricity thisseemed existing boiler plant and to make both economic and domestichotwater generation green sense. The systemis equipment, which had reached working very well. the end ofits useful life, and Mr Egerton added, We brought in new, high efficiency selectedthe Baxi-SenerTecUK condensing boilerslinked to the systembecause the Dachsisa mini-chp plant all under the proven and reliabletechnology. control of a BuildingEnergy We were particularly impressed Management System. bythe excellent product Graham Egerton, National information and technical Projects Manager at mechanical supportthroughout the design contractor Thermatic who and installation phase together carried out the work, said, The with a robust aftersales/ Cathedralisa live environment customercare service. so the M&Ebuildingservices It is anticipated that the works had to be carefully coordinated with the Cathedral s reduced by almost 30% Cathedral s energy use will be services. We alsohad to equatingto a saving in the contend with a challenging time region of 15,000 per year. frame,carryingout the works Built in 1826, Blackburn before the start ofthe heating Cathedral seats up to 1,250 season. people. The Cathedral site has The Dachspackaged mini- been home to a church for over CHPunit isdesigned for a thousandyearsand the first continuous running with a stone church was built design life ofaround 80,000 there in Norman times. runninghours. The reliable Baxi-SenerTecUK internalcombustion engine is part ofbaxi drives a low maintenance threephase electrical generator, and Commercial Division. the heat generated bythe engineiscapturedand transferred to the building s heatingsystem. It offers an overall fuel efficiency between 79% and 92% and includes an integratedmodem for off-site monitoringand control. Up to ten Dachs can be installed in a multi-module arrangement. Canon Andrew Hindley said, We fitted the Dachs system becausewe believe the stewardshipofgod s resources is paramount and that ifwe could use some ofour heat to Project Requirements: LZC (Low to Zero Carbon) appliances specified as part of anenergy reduction strategy Excellentcustomer service andproduct information required for complex heating, hot water and electricity system design Reliable heating and electricity all year round withminimal running costs Quick andstraightforward installationthat could be fittedaround the Cathedral s services Solutions: Baxi-SenerTec UK G 5.5 Dachs unit HISTORIC BUILDINGS FOCUS ON

Commercial Sales Technical & Service Enquiries Tel: 0845 070 1055 Fax: 0845 070 1059 Sales hotline: 0845 070 1056 Technical helpline: 0845 070 1057 Service hotline: 0845 070 1058 Spares Spares are available nationwide through the interpart network of approved stockists.alternatively please contact:- Interpart, Brooks House, Coventry Road Warwick CV34 4LL Tel: 0844 871 1540 web: www.interpartspares.co.uk Applications & Installations Our experienced technical support team are available to offer advice on any aspect of heating system design and boiler installation. Please contact: 0845 070 1057 Service and Maintenance Our service organisation, heateam Commercial Service covers the whole of the UK to look after your needs for all Baxi Commercial Division products. Our service office offers a wide range of specialised services including: Burner commissioning for all fuels Boiler service contracts Breakdown and repair services Burner and boiler replacement Oil/gas conversions Water treatment and descaling Packaged units For more information, or to talk to an advisor, call 0845 070 1058 All descriptions and illustrations contained within this brochure have been carefully prepared, but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information in this document. Publication Date: 0912 Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Sales: 0845 070 1056 Technical: 0845 070 1057 Email: andrews@baxicommercialdivision.com www.andrewswaterheaters.co.uk