Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Similar documents
M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

M60 LED Recessed Wet Location

M100 My White LED Direct Tunable White

M100 LED Direct/Indirect

M36 My White LED Direct

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

BAS SFP22 Edge-lit LED Panel

lumenalpha downlight Specification Sheet

Grüv Flare Regressed. Recessed Linear LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Grüv Flare Regressed. Recessed Linear LED

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

Classix 6" 6" Round Lens Wall Wash

SURFACE Spec Guide. up to 105 lm/w performance

Performance Chart Electrical Data

Murro HP. 3.5" Round Surface Canopy Wall Wash

Fino. Asymmetric Wall Mount Indirect LED

RECESSED Spec Guide. up to 111 lm/w performance

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evoke Square Downlight

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Etch 2' x 2' Recessed LED

Hornet HP. Round Glass Downlight

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Performance Chart Electrical Data

Performance Chart Electrical Data

Essenza. Round Downlights

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

LHBXD LED Linear High Bay

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Linea 1.5. Linear Direct Wall Wash LED

Evoke Square Downlight

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Classix 6" 6" Round Lens Wall Wash

Dimensions (111mm) (111mm) 3 (76mm)

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

CERRA 10 LED Design2Ship

Classix 6" 6" Round Lens Wall Wash

LUX PENDANT DIRECT/INDIRECT

RECESSED - WITH StepLens OPTION

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

IHOL-6DR / IRD600 6 Gravity LED Downlight

Classix 6" 6" Round Lens Downlight

Essenza. Square Downlights

Alliance 4 - ALI4 LED 4 Linear High Bay

LUXCOMFO TM LED Flood Light Datasheet

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

RECESSED T-Bar & Drywall

Evoke Square Downlight

Recessed LED Wall/Slot SAE 202

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Evoke 2.9" HP. 2.9" Square Downlight

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Evoke Round Downlight

Performance Chart Electrical Data

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

FPLHB - Fidelux Premier Linear Highbay

Highbay Linear LED Series Flat Profile Design

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Claude Indirect Wall WALL

IHOL-4DR / IRD400 4 Gravity LED Downlight

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

OPTIONS. Mounting LUMEN OUTPUT. Flat. Round PERFORMANCE. Color Temperature. Lumen Maintenance Binning Tolerance Warranty + +

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

SYSTEM. field cuttable. lipleds 8200 Series

Evoke 2.9" HP. 2.9" Square Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Velato. Recessed Slot Adjustable Multiples

RLN Recessed LED luminaire

3.75 Gyro Shift Multiples Single Head

Truss Surface SURFACE

Product Specifications MaxLumen MRI LED Diffused Lighting

VESICA LINEAR SUSPENDED VES L

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

Product Specifications MaxLumen MRI LED Diffused Lighting

Performance Chart Electrical Data

BeveLED Cylinder LBRP6 Surface

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

Max 4 Flush Lens RECESSED

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

ArcLine Recessed LED luminaire

Transcription:

Date: Customer: Project: Type: Qty: Cerro LED Order Code: CERLR - - - - - - - - - CERLR Series CERLR Cerro LED Light Engine 1L105 3210lm/37.8W 1L90 1L70 1L50 2751lm/32.4W 2140lm/25.2W 1529lm/18.0W 1L35 1070lm/12.6W * Values based on opal glass diffuser and 4000K CCT option. CCT 27 2700K 30 3000K 35 3500K 40 4000K Shielding GD Opal Glass D i ff u s e r CL Collector Lens Mounting RC 1 Retention Clamps SH Suspension Clips TS 1 Threaded Stud 1 For vertical mounting, include VM option Finish WH Voltage 120 208 220 240 277 120 Volt 208 Volt 220 Volt 240 Volt 277 Volt 347 2 347 Volt 2 10% min. dimming. IL105, IL70, IL35 only. Dimming options not available Fixture Options DL Damp Location Rated VM 3 Vertical Mount PC Perforated Center 3 Only available with RC and TS mounting *See page 5 for full details and restrictions Dimming Options DM eldoled 0-10V (Linear) DML eldoled 0-10V (Logarithmic) DMD eldoled DALI DC2 5 Lutron 2-Wire DC3 Lutron 3-Wire *The standard (default) driver is 0-10v capable, please see page 4 for additional details. DCE Lutron Eco-System DC5 4,6 Lutron 5-Series 4 Not available for 1L90 5 120V only 6 Consult factory for lead time *See page 4 for full details and restrictions Emergency Options EC Emergency Circuit Wiring UL 924 *See page 5 for full details and restrictions Product Modifications Please list modification requirements for review by factory: Approvals 5YEAR LED WARRANTY Date: Page 1 of 6

Retention Clamps (RC) Suspension Clips (SH) Threaded Stud (TS) 2 3 /4 (69mm) 14 1 /2 (368mm) 3 1 /2 (89mm) 14 3 /4 (375mm) 3 7 /16 (88mm) 14 3 /4 (375mm) Construction: Housing - Spun aluminum housing and reflector with diffuse white finish. Molded lens retention plate allows tool-less access to LED driver and holds secondary shielding securely in place. Shielding - All versions include a primary lens diffuser. Optional secondary shielding includes GD opal glass diffuser or CL polycarbonate collector lens. Mounting(s)- Choose from retention clips (RC) for installation after sheetrock, suspension clips (SH) for supporting luminaires independently from suspended ceiling, or threaded stud (TS) as an alternative method for independently supporting luminaire from ceiling. Luminaire may be installed in wall with RC and TS mounting as an option. Electrical/Performance: LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 84% at 60,000 hours per TM-21 report. LED Life - Calculated L70 greater than 100,000 hours and reported L70 greater than 60,000 hours @ 25 C per TM-21. CCT - Available in 2700K, 3000K, 3500K & 4000K, tolerance within a 3-step MacAdam ellipse. CRl - Min. 80 All s - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 5. s come standard with 2kV of surge protection. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of: 35 C (95 F); 30 C (86 F) for 347V. Minimum ambient temperature of: -20 C (-4 F) for the standard driver and optional DM, DML and DMD drivers. 0 C (32 F) for the optional DC2, DC3, DC5, and DCE drivers. Luminaire Finish: Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. Warranty: 5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the Cerro LED luminaire shall be free from defects in material and woriunanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see Selux Terms and Condition of Sale. Certifications and Compliance: NRTL - For Dry and Damp location only (I.E. culus; ccsaus) RoHS Compliant Page 2 of 6

Retension Clamps (RC) 17 3 /4 (451mm) 120 TYP Suspension Clips (SH) 4 15 /16 (125mm) 4 15 /16 (125mm) 5 11 /16 (144mm) (1) Hole 7 /8 (22mm) 2 13 /16 (72mm) (3) 1 /4 Mounting Holes Threaded Stud (TS) 2 3 /4 (70mm) (2) 1/4-20x1 Studs (1) Hole 7 /8 (22mm) Page 3 of 6

Standard 0-10V linear dimming Fixtures supplied with drivers capability of either normal switched operation or 0-10V dimming for linear dimming curve. Fixtures ship with the dimming leads capped, for dimming operation un-cap the wires. Minimum dimming level down to 1% (10% for 347V). Max. inrush current per driver 30mA²s and 0-10V control current Max. 2mA per driver. Optional eldoled Dimming s: eldoled 0-10V linear dimming (DM) Luminaires supplied with solodrive 0-10V dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. Max. inrush current per driver 30mA 2 s and 0-10V control current max 2mA per driver. eldoled 0-10V logarithmic dimming (DML) Luminaires supplied with solodrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For a minimum dimming level down to 0.1%, please consult factory. Max. inrush current per driver 30mA 2 s and 0-10V control current max 2mA. eldoled DALI dimming (DMD) Luminaires supplied with solodrive DALI dimming driver. Minimum dimming level preset at factory to 1%. For a minimum dimming level down to 0.1 %, please consult Selux. Inrush current per driver 30mA 2 s. *For control recommendation for eldoled drivers, please contact eldoled. Optional LUTRON Dimming s: LUTRON 5-series (DC5) Luminaires supplied with 5-series Ecosystem (4-wire, digital link) dimming driver programmed for constant current reduction (CCR). Minimum dimming level down to 5%. Inrush current per driver < 2A. LUTRON 2-wire dimming (DC2) Luminaires supplied with A-series 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult Selux. Minimum dimming level down to 1%. Inrush current < 2A. LUTRON 3-wire dimming (DC3) Luminaires supplied with A-series 3-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult Selux. Minimum dimming level down to 1%. Inrush current < 2A. LUTRON EcoSystem dimming (DCE) Luminaires supplied with A-series EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult Selux. Minimum dimming level down to 1 %. Inrush current per driver < 2A. **For control recommendation and system layout for LUTRON drivers, please contact LUTRON. Wiring Diagrams Standard - 0-10V (Linear) dimming capable *Grey (-) *Purple (+) Optional Dimming - 0-10v Logarithmic (DML) DALI Logarithmic (DMD) Grey (-) Purple (+) Standard Wiring supplied for all drivers. DML & DMD DC3 DCE = Ground = Neutral = Hot -The following wire(s) are in addition to the std. above- 0-10V Dimming for Standard driver DM DC2 DC5 *Grey = (-) 0-10V Dimming control *Purple = (+) 0-10V Dimming control *Grey and Purple feed wires are capped at the factory for non-dimming operation. For 0-10v dimming operation remove the caps on the Grey and Purple wires. Grey = (-) Dali or 0-10V Dimming control Purple = (+) Dali or 0-10V Dimming control No additional wires Orange = 3-Wire Dimming control Violet = "E1" Digital Link Dimming control Violet / = "E2" Digital Link Dimming control Violet = "E1" Digital Link Dimming control Violet / = "E2" Digital Link Dimming control Optional Dimming - Lutron 2-Wire (DC2) Optional Dimming - Lutron 3-wire (DC3) Orange Optional Dimming - Lutron Eco System (DCE) - Lutron 5-series (DC5) Violet Violet / Page 4 of 6

Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs are free of coating to avoid hazing. Vertical Mount (VM) - Luminaire provided with internal lens shim to allow for mounting in a vertical position. Perforated Center (PC) - Luminaire to be supplied with perforated center plate (.045Ø holes on 0.88 centers) staggered hole pattern. Emergency Circuit (EC) - Luminaire to be operated on a separate EM circuit and operated separately by default to meet the required Life Safety Code (NFPA 101 ). If a different configuration is needed please consult the factory. Luminaires with EC option are compliant to UL 924. EC luminaires are intended to be wired to separate panels/breakers for emergency use. Transfer switch supplied by others. Maximum installation height is 40ft with EC option. Page 5 of 6

Photometry CL Optics / 37.8W LED / 4000K CCT Link to photometry (IES & PDF files) 1890 1418 945 Catalog #: CERL-1L105-40-CL-120 Report #: 843128 Delievered Lumens: 3050 Input Watts: 37.8W Efficacy: 81 Power Factor:.99 Total Harmonic Distortion: 6.06% CCT: 4000K CRI: >80 Max Candela: 1890 @ 0 from Vertical Spacing Criterion (0-180): 1.04 Spacing Criterion (90-270): 1.04 Spacing Criterion (Diagonal): 1.12 473 1 2 Maximum Candela = 1890.4 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (90-270) # 2 - Vertical Plane Through Horizontal Angles (0-180) GD Optics / 37.8W LED / 4000K CCT Link to photometry (IES & PDF files) 1591 1193 795 Catalog #: CERL-1L105-40-GD-120 Report #: 843129 Delievered Lumens: 3210 Input Watts: 37.8W Efficacy: 85 Power Factor:.99 Total Harmonic Distortion: 6.06% CCT: 4000K CRI: >80 Max Candela: 1591 @ 0 from Vertical Spacing Criterion (0-180): 1.12 Spacing Criterion (90-270): 1.12 Spacing Criterion (Diagonal): 1.18 398 1 2 Maximum Candela = 1590.8 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (90-270) # 2 - Vertical Plane Through Horizontal Angles (0-180) CCT Multiplier 4000K 1.000 3500K 0.968 3000K 0.987 2700K 0.939 CCT multipliers apply to the photometry, IES files, and lumen values listed on page one (light engine). Page 6 of 6